• Title/Summary/Keyword: use

Search Result 110,875, Processing Time 0.122 seconds

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control (핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용)

  • Jung, Heung-Soo;Bae, Jin-Soo;Shin, Yong-Hwan;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.115-118
    • /
    • 2012
  • Purpose: The Levey-Jennings chart controlled measurement values that deviated from the tolerance value (mean ${\pm}2SD$ or ${\pm}3SD$). On the other hand, the upgraded Westgard Multi-Rules are actively recommended as a more efficient, specialized form of hospital certification in relation to Internal Quality Control. To apply Westgard Multi-Rules in quality control, credible quality control substance and target value are required. However, as physical examinations commonly use quality control substances provided within the test kit, there are many difficulties presented in the calculation of target value in relation to frequent changes in concentration value and insufficient credibility of quality control substance. This study attempts to improve the professionalism and credibility of quality control by applying Westgard Multi-Rules and calculating credible target value by using a commercialized quality control substance. Materials and Methods : This study used Immunoassay Plus Control Level 1, 2, 3 of Company B as the quality control substance of Total T3, which is the thyroid test implemented at the relevant hospital. Target value was established as the mean value of 295 cases collected for 1 month, excluding values that deviated from ${\pm}2SD$. The hospital quality control calculation program was used to enter target value. 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T of Westgard Multi-Rules were applied in the Total T3 experiment, which was conducted 194 times for 20 days in August. Based on the applied rules, this study classified data into random error and systemic error for analysis. Results: Quality control substances 1, 2, and 3 were each established as 84.2 ng/$dl$, 156.7 ng/$dl$, 242.4 ng/$dl$ for target values of Total T3, with the standard deviation established as 11.22 ng/$dl$, 14.52 ng/$dl$, 14.52 ng/$dl$ respectively. According to error type analysis achieved after applying Westgard Multi-Rules based on established target values, the following results were obtained for Random error, 12s was analyzed 48 times, 13s was analyzed 13 times, R4s was analyzed 6 times, for Systemic error, 22s was analyzed 10 times, 41s was analyzed 11 times, 2 of 32s was analyzed 17 times, $10\bar{x}$ was analyzed 10 times, and 7T was not applied. For uncontrollable Random error types, the entire experimental process was rechecked and greater emphasis was placed on re-testing. For controllable Systemic error types, this study searched the cause of error, recorded the relevant cause in the action form and reported the information to the Internal Quality Control committee if necessary. Conclusions : This study applied Westgard Multi-Rules by using commercialized substance as quality control substance and establishing target values. In result, precise analysis of Random error and Systemic error was achieved through the analysis of 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T rules. Furthermore, ideal quality control was achieved through analysis conducted on all data presented within the range of ${\pm}3SD$. In this regard, it can be said that the quality control method formed based on the systematic application of Westgard Multi-Rules is more effective than the Levey-Jennings chart and can maximize error detection.

  • PDF

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

Environmental Management of Marine Cage Fish Farms using Numerical Modelling (수치모델을 이용한 해상어류가두리양식장의 환경관리 방안)

  • Kwon, Jung-No;Jung, Rae-Hong;Kang, Yang-Soon;An, Kyoung-Ho;Lee, Won-Chan
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.10 no.4
    • /
    • pp.181-195
    • /
    • 2005
  • To study the effects of aquaculture activity of marine cage fish farms on marine environment, field researches including hydrography, sediment, benthos and trap experiment at the marine cage fish farms(Site A) around estuaries of Tongyeong city were carried out during June $26\~27$, 2003. A simulation using numerical model-DEPOMOD was conducted to predict the solid deposition from fish cage and to assess the probable solid deposition, and the efficiency of environmental management of marine cage fish farms was studied. The marine cage fish farms cultured mainly common sea bass (Lateolabrax japonicus), red seabream (Pagrus major), striped breakperch (Oplegnathus fasciatus) and black rockfish(Sebastes schlegeli), and total amount of cultured fish of the Site A were 23.1MT. The amount of husbandry fish by unit area(and volume) of the fish cage was $43.0kg\;m^{-2}(6.1kg\;m^{-3})$. The daily mean amounts of food fed by unit biomass and cage area were $30.8g\;kg^{-1}day^{-1},\;1.32kg\;m^{-2}day^{-1},$ respectively, at the Site A. The concentration of ORP of the sediment below the center at the Site A was -334.6 mV and the concentrations of AVS, COD, Carbon and Nitrogen were $0.43mg\;g^{-1}dry,\;17.75mg\;g^{-1}dry,\;10.19mg\;g^{-1}dry\;and\;3.49mg\;g^{-1}dry$, respectively. Capitella capitata was dominant benthic species which occupied $57.8\%$ of total species, and the Infaunal Trophical Index(ITI) was marked below 20 within 20 m distance from the edge of the Site A. The result of trap experiment, the solid deposition from the Site A was $34,485g\;m^{-2}yr^{-1}$ at 0 m from the center of the cage and $18,915g\;m^{-2}yr^{-1}$ at 42 m. From a model simulation, it was estimated that using a model simulation, the proportion of unfed food was $40\%$ at the Site A and the annual total amount of solid deposition was 63,401 accounting for $24.4\%$ of the annual total food fed at the Site A. The area solid deposition settled was estimated to be $8,450m^2$, which was about 16 times of the total area of fish cage at the Site A. And concerning ITI and abundance of benthos, the model predicted that sustainable solid flux at the Site A was below $10,000gm^{-2}yr^{-1}$. The percentage of food wasted was main element of solid deposition at the marine cage fish farms, and for minimizing solid deposition it is necessary to increase the efficiency of the food uptake. Based on the result of the model simulation, if the percentage of food wasted decreases to $10\%$ from the current $40\%$, then the solid deposition could decrease to a half. In addition, it was predicted that if farmers use EP pellets as food fed instead of MP and fish trash, solid deposition could decrease by $57\%$. Also this study proposes that the cage facility ratio of the licensed area be decreased to less than $5\%$ to minimize the sediment pollution.

Preparation of Pure CO2 Standard Gas from Calcium Carbonate for Stable Isotope Analysis (탄산칼슘을 이용한 이산화탄소 안정동위원소 표준시료 제작에 대한 연구)

  • Park, Mi-Kyung;Park, Sunyoung;Kang, Dong-Jin;Li, Shanlan;Kim, Jae-Yeon;Jo, Chun Ok;Kim, Jooil;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • The isotope ratios of $^{13}C/^{12}C$ and $^{18}O/^{16}O$ for a sample in a mass spectrometer are measured relative to those of a pure $CO_2$ reference gas (i.e., laboratory working standard). Thus, the calibration of a laboratory working standard gas to the international isotope scales (Pee Dee Belemnite (PDB) for ${\delta}^{13}C$ and Vienna Standard Mean Ocean Water (V-SMOW) for ${\delta}^{18}O$) is essential for comparisons between data sets obtained by other groups on other mass spectrometers. However, one often finds difficulties in getting well-calibrated standard gases, because of their production time and high price. Additional difficulty is that fractionation processes can occur inside the gas cylinder most likely due to pressure drop in long-term use. Therefore, studies on laboratory production of pure $CO_2$ isotope standard gas from stable solid calcium carbonate standard materials, have been performed. For this study, we propose a method to extract pure $CO_2$ gas without isotope fractionation from a solid calcium carbonate material. The method is similar to that suggested by Coplen et al., (1983), but is better optimized particularly to make a large amount of pure $CO_2$ gas from calcium carbonate material. The $CaCO_3$ releases $CO_2$ in reaction with 100% pure phosphoric acid at $25^{\circ}C$ in a custom designed, evacuated reaction vessel. Here we introduce optimal procedure, reaction conditions, and samples/reactants size for calcium carbonate-phosphoric acid reaction and also provide the details for extracting, purifying and collecting $CO_2$ gas out of the reaction vessel. The measurements for ${\delta}^{18}O$ and ${\delta}^{13}C$ of $CO_2$ were performed at Seoul National University using a stable isotope ratio mass spectrometer (VG Isotech, SIRA Series II) operated in dual-inlet mode. The entire analysis precisions for ${\delta}^{18}O$ and ${\delta}^{13}C$ were evaluated based on the standard deviations of multiple measurements on 15 separate samples of purified $CO_2$. The pure $CO_2$ samples were taken from 100-mg aliquots of a solid calcium carbonate (Solenhofen-ori $CaCO_3$) during 8-day experimental period. The multiple measurements yielded the $1{\sigma}$ precisions of ${\pm}0.01$‰ for ${\delta}^{13}C$ and ${\pm}0.05$‰ for ${\delta}^{18}O$, comparable to the internal instrumental precisions of SIRA. Therefore, we conclude the method proposed in this study can serve as a way to produce an accurate secondary and/or laboratory $CO_2$ standard gas. We hope this study helps resolve difficulties in placing a laboratory working standard onto the international isotope scales and does make accurate comparisons with other data sets from other groups.

Incidence of Chronic Pathologic Nephrotoxicity of Cyclosporine A in Pediatric Nephrotic Syndrome (소아 신증후군에서 Cyclosporine A에 의한 만성 조직학적 신독성의 발현빈도에 대한 연구)

  • Kim Ji-Hong;Jeong Hyun-Ju;Choi In-Jun;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.130-144
    • /
    • 1999
  • Purpose : Long-term use of Cyclosporine(CsA) reduce renal blood flow by afferent arteriolar vasoconstriction and lead to chronic pathologic changes of CsA nephrotoxicity - 1) interstitial nephritis(IN); tubular atrophy (TA) and/or interstitial fibrosis(IF),2) arteriolopathy(AP). The Object of this study is to estimate the incidence of chronic pathologic CsA nephrotoxicity by duration of treatment and type of renal disease, relationship between histologic and clinical nephrotoxicity, and optimal duration of CsA therapy. Methods : 102 children with steroid resistant or dependent nephrotic syndrome confirmed by renal biopsy and treated with CsA from 1986 to 1997 were enrolled in this study(58 MCNS, 10 FSGS, 10 MGN, 15 $Henoch-Sch\"{o}nlein$ purpura nephritis with nephrotic syndrome (HSPN) and 9 IgA nephropathy with nephrotic syndrome(IgAN)). CsA was administered for 1yr, 1.5yr, 2yr in 24, 12, 22 MCNS patients and 2, 2, 6 FSGS patients respectively, 1yr, 2yr in MGN and 1yr in HSPN and IgAN. Sequential biopsies were done in all 102 patients after CsA treatment for evaluation of pathologic nephrotoxicity. Results : Complete remission rate was 92.2% (100% in MCNS and MGN, 80% in FSGS, 86.6% in HSPN and 55.5% in IgAN). Incidence of relapse during 6months after CsA treatment was significantly decreased compaed with relapsing spisodes during 6months before CsA treatment in MCNS(P<0.0001) and FSGS(P<0.0001). According to pathologic changes, 71 patients(69.6%) showed no pathological change, 24 patients(23.5%) showed IN and 7 patients(6.8%) showed AP. IN was 16.6%, 33.3%, 27.2% in 1, 1.5, 2 year of CsA treatment group in MCNS. AP was 0%, 16.6%, 9% in 1, 1.5, 2 year of CsA treatment group in MCNS. 14 out of 58 MCNS(24.1%) showed IN and 4 out of 58 MCNS(6.8%) showed AP. Incidence of pathologic change was significantly lower in CsA therapy of <1yr than >1yr(P=0.03). There were no significant difference of incidence of pathologic change in original renal disease, age and sex. Conclusion : Duration of CsA treatment was significant risk factor for nephrotoxicity and optimal duration seemed to be 1 year. Pathologic change due to nephrotoxicity did not correlate with deterioration of renal function and only detectable by renal biopsy.

  • PDF

Kinemetic analysis of a thumping security motion with an expandable barton (경호원의 삼단봉 머리치기 동작의 운동학적 분석)

  • Kim, Yong-Hak;Kim, Sin-Hye;Jung, Sung-Bae
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.93-109
    • /
    • 2013
  • This research is mainly based on the experimental result due to seek different outcomes whena certain security motion with a paticular gear is applied in a plausible confrontational situation. For the purpose of this research an Expandable Baton, which is one of the most commonsecurity equipments, was chosen to be applied in a situation of hitting a person's head. Alsothe results will be studied in the view of Kinematic theory. To demonstrate, 10 students who were majeored in Escort Crane studies at 'H' university werechosen as testees. The participants were grouped into two-one is practiced with the 'expanadable baton use program' and the other is pre-practiced. In this report two groups abovewill be reffered as 'group A' and 'group B' for conveniency. There were a number of differences and changes between two groups. Group B took more timethan the other group did. Group A spent about 0.428sec in section 'e2' and 0.230sec in section'e3' while Group B took 0.435sec, 0.232sec in each sections.To add on, more distinctive results were out when it was more focused on physical movements. Two gropus presented considerable changes- in an 'left-right' moving displacement-Group A;$2.16{\pm}0.9cm$ (left side), $3.78{\pm}1.42cm$ (right side), total $5.94{\pm}2.03cm$. Group B; $2.97{\pm}1.01cm$ (left side),$4.56{\pm}1.57cm$ (right side), total $7.53{\pm}2.13cm$.Continuously, different outcomeswere shown between two groups in a 'back and forth' moving displacement-Group A;$32.48{\pm}3.86cm$, $35.21{\pm}4.64cm$, total $69.36{\pm}5.72$. Group B; $34.50{\pm}6.12cm$, $37.04{\pm}3.70cm$, total $71.46{\pm}7.17cm$. Furthermore, changes in an 'up and down' moving displacement were - GroupA; $5.62{\pm}2.41cm$, $4.54{\pm}1.87cm$, total $10.11{\pm}1.57cm$. Group B; $6.33{\pm}1.78cm$, $4.86{\pm}1.85cm$,total $10.68{\pm}1.81cm$. To continue, there were few modifications of degree on participants' joints, espcially on 'Wristjoint', 'Elbow joint' and 'Shoulder joint', depend on different sections -Wrist joint;Group A; e1 $114.62{\pm}7.13$, e2 $68.27{\pm}6.37$, e3 $131.64{\pm}6.27$. Group B; e1 $112.62{\pm}6.13$, e2 $66.28{\pm}7.38$, e3$137.42{\pm}4.28$ and Elbow joint ; Group A e1 $132.31{\pm}6.55$, e2 $117.92{\pm}8.42$, e3 $144.41{\pm}6.32$. Group B; e1 $133.58{\pm}8.56$, e2 $114.45{\pm}8.21$, e3 $139.89{\pm}4.38$. Lastly, degree changes ofshoulder joint were; Group A; e1 $13.55{\pm}3.85$, e2 $131.42{\pm}11.24$, e3 $78.32{\pm}6.28$. Group B; e1$9.45{\pm}1.23$, e2 $136.74{\pm}13.21$, e3 $79.75{\pm}4.24$.

  • PDF

Studies on absorption of ammonium, nitrate-and urea-N by Jinheung and Tongil rice using labelled nitrogen (중질소(重窒素)를 이용(利用)한 진흥(振興)과 통일(統一)벼의 암모니움, 질산(窒酸) 및 요소태(尿素態) 질소(窒素)의 흡수특성(吸收特性) 연구(硏究))

  • Park, Hoon;Seok, Sun Jong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.10 no.4
    • /
    • pp.225-233
    • /
    • 1978
  • Uptake and distribution of labelled urea, $NH{_4}^+$, and $NO{_3}^-$ by Tongil and Jinheung rice grown with each nitrogen source until ear formation stage under water culture system were as follows. 1. When the previous nitrogen source was same as one tested the uptake rate ($mg^{15}N/g$ d.w. root 2hrs, at $28^{\circ}C$ light) was great in the order of $NH_4$ >urea> $NO_3$ and higher (especially $NH_4$) in Tongil than in Jinheung. Rate limiting step (slowest) seems to be exist at R (root)${\rightarrow}$LS(leaf sheath) for urea, LS${\rightarrow}$LB(leaf blade) for $NH_4$ and M(medium)${\rightarrow}$R for $NO_3$. The fast step of translocation appeare to be at M${\rightarrow}$R for urea R${\rightarrow}$LS for $NH_4$ and LS${\rightarrow}$LB for $NO_3$. 2. The uptake rate of $NH_4$ by the urea-fed plant increased almost linearly from $18^{\circ}C$ via $28^{\circ}C$ to $38^{\circ}C$ in Tongil ($Q_{10}$=1.21 and 1.32 respectively) while no change in Jinheung ($Q_{10}$=0.99 and 1.00 respectively). It decreased by 12% in Jinheung under dark but uo change in Tongil. 3. The uptake rate of nitrogen source by different source-fed plant was great in the order of $NH_4{\rightarrow}^{15}NO_3$ $NO_3{\rightarrow}^{15}NH_4$, $urea{\rightarrow}^{15}NO_3$ and higher (especially $NH_4{\rightarrow}^{15}NO_3$) in Tongil. In the case of $urea{\rightarrow}^{15}NH_4$ it was same in $NH_4{\rightarrow}^{15}NO_3$ for Tongil and slightly lower than that in $NO_3{\rightarrow}^{15}NH_4$ for Jinheung. It was lower (especially Tongil) in $NH_4{\rightarrow}^{15}NO_3$ than in $NH_4{\rightarrow}^{15}NH_4 $ 4. The uptake rate (in $NH_4{\rightarrow}^{15}NO_3$) was higher during 15 minutes than during 2 hours and always higher in Tongil. 5. $^{15}N$ excess % and content in each part, and uptake rate of root seems to have their own significance relatling with metabolism and translocation respectively. The change of nitrogen nutritional environment and source preference of varieties were discussed in relation to field condition and efficient use of nitrogen fertilizer.

  • PDF