• Title/Summary/Keyword: urethane

Search Result 634, Processing Time 0.029 seconds

Preparation of Fe4[Fe(CN)6]3 Coated on Mica or TiO2/Mica for Infrared Reflective Blue Pigments and Isolation-heat Properties of These Paints (Fe4[Fe(CN)6]3가 코팅된 Mica 또는 TiO2/Mica 적외선 반사용 청색안료 제조 및 이 도료의 차열 특성 평가)

  • Jung, Ha-Young;Kim, Dae Sung;Lee, Hyun-Jin;Lee, Seung-Ho;Lim, Hyung Mi;Choi, Byung-Ki;Kang, Kwang-Jung;Choi, Jin-Sub
    • Korean Journal of Materials Research
    • /
    • v.23 no.12
    • /
    • pp.672-679
    • /
    • 2013
  • $Fe_4[Fe(CN)_6]_3$ coated on a mica or $TiO_2$/mica surface as infrared reflective blue pigment was prepared by a hydrothermal method. $Fe_4[Fe(CN)_6]_3$, used as coloring agent, was uniformly coated on mica or $TiO_2$/mica under the optimized condition of a 1.2 : 1 weight ratio between iron(III) chloride hexahydrate and potassium ferrocyanidetrihydrate at the initial pH level of 4.5 at $70^{\circ}C$. The infrared (IR)-reflective pigments were characterized by SEM, Zeta-potenial, FT-IR, and UV-VIS NIR spectrophotometry. Especially the CIE color coordinate and total solar reflectance(TSR) properties of the pigments were investigated in relation to variation of the coating and coated substrate thicknesses. Isolation-heat paint was prepared with 20 wt% blue pigments fully dispersed in acryl-urethane resin and several additives to coat the film uniformly. The films were also measured with CIE color coordinate, TSR, and the surface temperature was recorded by an isolation-heat measuring system. The pigments and films of $Fe_4[Fe(CN)_6]_3$ coated on mica and $TiO_2$/mica showed high TSR values compared with the TSR value of $Fe_4[Fe(CN)_6]_3$ itself. According to the increase of TSR value, the property of isolation-heat is effective. To realize the optimal blue color, we applied the the pigment to $TiO_2$ coated mica(TM(b)) which has blueish interference color. The pigment of $Fe_4[Fe(CN)_6]_3$ coated on TM(b) shows a strong blue color compared with that of $Fe_4[Fe(CN)_6]_3$ coated on $TiO_2$/Mmca(TM(w)), which has a whitish interference color.

Genetic Toxicity Test of o-Nitrotoluene by Ames, Micronucleus, Comet Assays and Microarray Analysis

  • Lee, Eun-Mi;Lee, So-Youn;Lee, Woo-Sun;Kang, Jin-Seok;Han, Eui-Sik;Go, Seo-Youn;Sheen, Yhun-Yong;Kim, Seung-Hee;Park, Sue-Nie
    • Molecular & Cellular Toxicology
    • /
    • v.3 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • o-Nitrotoluene is used to synthesize artificial dyes and raw materials of urethane resin. In this study, we have carried out in vitro genetic toxicity tests and microarray analysis to understand the underlying mechanisms and the mode of action of toxicity of onitrotoluene. TA1535 and TA98 cells were treated with o-nitrotoluene to test its toxicity by basic genetic toxicity test. Ames and two new in vitro micronucleus and COMET assays were applied using CHO cells and L5178Y cells, respectively. In addition, microarray analysis of differentially expressed genes in L5178Y cells in response to o-nitrotoluene was analyzed using Affymatrix genechip. The result of Ames test was that o-nitrotoluene treatment did not increase the mutations both in base substitution strain TA1535 and in frame shift TA98. o-Nitrotoluene has not increased micronuclei in CHO cells. But onitrotoluene increased DNA damage in L5178Y cell. Two-hundred two genes were initially selected as differentially expressed genes in response to o-nitrotoluene by microarray analysis and forty four genes among them were over 2 times of log fold changed. These forty four genes could be candidate biomarkers of genetic toxic action of o-nitrotoluene related to induction of mutation and/or induction of micronuclei and DNA damage. Further confirmation of these candidate markers related to the DNA damage will be useful to understand the detailed mechanism of action of o-nitrotoluene.

Effects of DMTU, SOD and Ischemic Preconditioning on the Ultrastructural Changes of the Rectus Femoris Muscles in Rats after Ischemia and Reperfusion (SOD, DMTU및 허혈양상화 처치가 허혈 및 재관류에 의한 흰쥐 넙다리곧은근의 미세구조 변화에 미치는 영향)

  • Paik, Doo-Jin;Lim, Jae-Hyun;Chung, Ho-Sam
    • Applied Microscopy
    • /
    • v.27 no.3
    • /
    • pp.333-346
    • /
    • 1997
  • The ischemia and reperfusion injury of the skeletal muscles is caused by generation of reactive oxygen during ischemia and reperfusion. It is well known that over 4 hours of ischemia injures the skeletal muscles irreversibly. The author has demonstrated the effects of SOD (superoxide dismutase), DMTU (dimethyl thiourea) and ischemic preconditioning on ultrastructural changes of the muscle fibers in the rectus femoris muscles after 4 hours of ischemia and 1 day and 3 days of reperfusion. A total of 72 healthy Sprague-Dawley rats weighing from 200 gm to 250 gm were used as experimental animals. Under urethane(1.15 g/kg, IP, 2 times) anesthesia, lower abdominal incision was done and the left common iliac artery was occluded by using vascular clamp for 4 hours. The left rectus femoris muscles were obtained at 1 and 3 days after the removal of vascular clamp. The SOD (15,000 unit/kg) or DMTU (500 mg/kg) were administered intraperitoneally at 1 hour before induction of ischemia. The ischemic preconditioned group underwent three episodes of 5 minutes occlusion and 5 minutes reperfusion followed by 4 hours of ischemia and 1 day and 3 days of reperfusion. The specimens were sliced into $1mm^3$ and prepared by routine methods for electron microscopic observation. All specimens were stained with uranyl acetate and lead citrate and then observed with Hitachi-600 transmission electron microscope. The results were as follows: 1. SOD or DMTU alone did not affect the ultrastructure of muscle fibers in the rectus femoris muscles. The electron density of mitochondrial matrix was decreased by ischemic preconditioning. 2. Dilated cisternae of sarcoplasmic reticulum, triad, mitochondria and the loss of myofilament in the sarcomere were observed in the 4 hours ischemia and 1 day reperfused rectus femoris muscles. Markedly changed sarcoplasmic reticulum, triad, disordered or loss of myofilament, indistinct A-band and I-band, and irregular electron lucent M -line and Z-line are seen in the 4 hours ischemia and 3 days reperfused rectus femoris muscles. 3. SOD reduced the changes of organelles in the muscle fibers of the 4 hours ischemia and 1 day reperfused rectus femoris muscles of the rats, but SOD did not affect the changes of muscle fibers in the 4 hours ischemia and 3 days reperfused muscles. On the other hand, DMTU markedly attenuated considerably the ultrastructural change of the 4 hours ischemia and 1 day or 3 days reperfused rectus femoris muscles. 4. By the ischemic preconditioning, the change was attenuated remarkably in the 4 hours ischemia and 1 day reperfused rectus femoris muscles. As the ischemic reperfused changes of muscle fibers were regenerated or recovered by ischemic preconditioning, the ultrastructures of them were similar to those of normal control in the 4 hours ischemia and 3 days reperfused rectus formoris muscles. Consequently, it is suggested that DMTU is stronger inhibitor to ischemic reperfused change than SOD. The ischemia and reperfusion-induced muscular damage is remarkably inhibited by ischemic preconditioning.

  • PDF

The Reactivity of Different Polyols for Paint to Polyisocyanate (도료용 폴리올 종류에 따른 폴리이소시아네이트와의 반응성)

  • Seo, Seok-Hwan;Suh, Cha-Soo;Park, Jin-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.388-396
    • /
    • 2008
  • 2 Components polyurethane coatings are widely used for the industrial coating in general because of its excellent film performance and the workability which were brought by the 3 dimensional cross linked chain structures being formed after the reaction between polyol and polyisocyanate. 2 components polyurethane can be classified into alkyd polyol, polyester polyol, acrylic polyol and polyester modified acrylic polyol depending on where it is used. This research was conducted under the conditions below; different chemical compositions of resin for paint, set the same conditions of viscosity, thinner and acid value, set alternative polyols, OH values and catalysts, set alternative polyisocyanate hardeners of the paint, measure the reaction rates and dynamic mechanical characteristics using RPT-3000, Rotation Rheometer, DMA and FTIR. The research found that the reactivity between polyol and isocyanate influences the film performance and workability depending on the catalysts, OH values and chemical compositions. We find out that different reaction rate of acrylic polyol and polyester modified acrylic polyol with poly-isocyanate is not influenced on temperature and catalyst. In addition, reaction speed of high hydroxyl content polyol is faster than low hydroxyl equivalent. These results can improve difficult working condition to apply urethane coating.

A Study on the Durability Improvement by Controlling the Deterioration of Underground Concrete Structures (지하 콘크리트구조물의 열화 억제에 의한 내구성 증진에 관한 연구)

  • 천병식;최춘식;정원우
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.23-31
    • /
    • 2004
  • Normally, coating is used for protecting reinforced concrete. For this purpose, both organic and inorganic coatings are used. The advantages of inorganic coatings are lower absorption of UV, non-burning etc. On the other hand, organic coatings have the advantage of low permeability of $CO_2, SO_2$ and water. Organic coatings provide better protection for reinforced concrete. However, organic coatings such as epoxy, urethane and acryl reduce long-term adhesive strength by the difference of their thermal expansion coefficients and elastic modules from those of concrete, and the formed coating cover of these is blistered by poor breathing. Also, when organic coatings are applied to the wet surface of concrete, they have a problem with adhesion. In this study, a new coating material for protecting concrete was hybridized with polymer and ceramics. And tests were carried out on its physical and durable characteristics, and safety characteristic on elution. All results were compared with organic coating materials and epoxies and showed that the performance of the developed coating material was not inferior to that of other organic coatings in protecting concrete. On the other hand, safety characteristic on elution was superior to epoxies which were used in this study. So, the developed coating material was considered as a suitable protecting coating material which have advantages of inorganic and organic coatings for protecting underground concrete structures, especially in contact with water.

EFFECTS OF ELECTROACUPUNCTURE AND NALOXONE ON MOUTH OPENING REFLEX (전기침과 Naloxone이 개구반사에 미치는 영향)

  • Park, Min-Gap;Seo, Young-Ah;Song, Hyung-Geun;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.467-475
    • /
    • 1998
  • 악안면 영역에 동통이 가하여지면 회피반사의 일종인 개구반사가 유발되며, 개구반사의 크기는 뇌간의 중추에 전달된 동통의 크기에 비례한다. 따라서 동통의 정도를 악이복근의 근전도를 이용하여 정량화 할 수 있고 동통의 지표로 이용할 수 있다. 본 실험은 악안면동통에 의하여 유발된 개구반사의 크기가 침점(족삼리) 전기자극으로 감소되는지와 이러한 전기침의 효과가 나타나는데 opioid 물질이 관여하는지에 대하여 연구하고자 하였다. 8주 이상, 150g이상의 Sprague-Dawley계 쥐 34 마리를 암수 구별없이 이용하여 실험하였다. 복강 내 Urethane용액(1.5g/kg)을 주입 전신마취하고 악이복근을 노출시켜 근전도 기록을 위한 한쌍의 선전극을 삽입하였다. 동통유발을 위하여 구강내 하악 이공주변에 0.1mm의 선전극을 한쌍 삽입하고 전기자극기에 연결하였다. 유해자극 조건은 duration $100{\mu}sec$, interval 5sec의 pulse로 정하고 자극의 크기는 개구반사를 일으키는 역치의 2배 크기로 하며 매 측정시마다 동일 자극을 10회식 가하여 평균하였다. 침점의 전기자극을 위하여 침점의 하나인 족삼리(Zusanli)에 표면전극(넓이 $0.4cm^2$ 정도)을 부착하고 자극부위가 약한 근수축을 일으키는 강도인 $100{\mu}sec$, 5V, 2Hz의 자극을 20분간 가하였다. 악이복근의 근전도는 교류증폭기 (Dam80, WPI, USA) 에서 1000배 증폭하여 유해자극이 가해진 순간 oscilloscope 에서 관찰하여 그 크기를 측정하였다. 침점의 전기자극으로 나타나는 진통효과가 opioid의 분비와 관련있는지 알아보기 위하여 opioid 의 길항제인 naloxone(0.2mg/kg)을 복강 내로 투여하였다. 실험군을 4군(group I - IV)으로 분류하였고 각 군에서 근전도를 측정한 단계는 다음과 같다. group I : control 침점에 전기자극 20 분간 가한후(EA), 20분후(EA20) group II : control 침점에 전기자극 20분간 가한후(EA), naloxone 투여 20분후(NX) group III : control naloxone 투여 5분후 침점에 전기자극 20분 가한후(NxEA20) group IV : control naloxone 투여 20분후(NX20) 구강내에 가해진 유해자극에 의하여 발생하는 악이복근 근전도는 족삼리 침점의 전기자극으로 그 크기가 감소하였고 이러한 침점자극의 효과는 naloxone의 투여로 인하여 억제되었다. 이와 같은 결과는 침점자극으로 진통작용이 나타나는데에 opioid 물질이 관여하고 있음을 시사한다.

  • PDF

The Effect of Finger Joint Location on Bending Strength Properties (핑거접합부의 위치가 휨강도성능에 미치는 영향)

  • Won, Kyung-Rok;Hong, Nam-Euy;Ryu, Hyun-Soo;Park, Han-Min;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.318-326
    • /
    • 2013
  • The effect of finger joint location and distance from joint to joint one another on 3 point mid-concentration bending strength properties was investigated in this experiment. Resorcinol-phenol formaldehyde (RPF) and aqueous vinyl urethane (AVU) was used to domestic Pinus densiflora Sieb. et Zucc and imported Picea sitchensis Carr. that have been cut to different width of 0.15 mm between finger tip and root width and the distance from loading point to finger joint was 0, 30, 40, 50, 60 mm. The effect was not found on the location and distance of finger joint for bending modulus of elasticity, while the efficiency of bending strength property increased proportionally as the location of finger joint from the load point and the distance between finger joint increased. No influence was shown by finger joint location and distance beyond 3 times of specimen thickness, since similar values were shown between the solid wood and no destruction occurred materials.

Buckling Behavior of Sandwich Composite Columns by Varying Hole Size and Hole Position (원공 크기 및 원공 위치에 따른 샌드위치 복합재 기둥의 좌굴 거동)

  • Lee, Sang-Jin;Yoon, Sung-Ho
    • Composites Research
    • /
    • v.25 no.1
    • /
    • pp.19-25
    • /
    • 2012
  • The study investigated the buckling behavior of sandwich composite columns with different hole sizes and hole positions when they were applied to a compressive load. The columns consisted of 1.7mm thick faces of glass fabric/epoxy and 23mm, 37mm, 48mm, and 61mm thick cores of urethane-foam. Different hole sizes with the diameter of 25mm and 38mm were considered in this experiment. To evaluate the effect of hole position on the buckling behavior, we considered three types of hole position: 25mm diameter hole located at the center, 25mm diameter hole at 1/4 position from the center to the end of the column, and 25mm diameter hole at 1/2 position from the center to the end of the column. According to the results, buckling and maximum loads of the column having 25mm diameter hole were lower by 10% compared to those of the column without hole, whereas the loads for the column having 38mm diameter hole were 30% less than those of the column without hole. Hole position appeared to have no effect on buckling and maximum loads. Major failure modes were observed as follows: the core shear failure for the thin columns having 23mm and 37mm thick cores, and the face-core debonding for the thick columns having 48mm and 61mm thick cores.

A Study on Property with Ratio of Water Mixture in Hydroponic Polyurethane Waterproofing Materials (수경화성 폴리우레탄 도막 방수재의 물 혼합비에 따른 물성변화연구)

  • Park, Jin-Sang;Park, Wan-Goo;Kim, Dong-Bum;Lee, Min-Kyu;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.4
    • /
    • pp.348-354
    • /
    • 2015
  • Urethane waterproofing materials which currently being used most commonly in the Korean domestic market have high applicability and construct layers without forming any joints, but under the influence of low temperature and low humidity, as well as the thickness of the applied layer, the curing time of this material may become extended in construction sites. To resolve these issues, a proposed method of using water-hardening type of polyurethane waterproofing materials are being developed. However, there currently lacks any standards or evaluation methods on determining an optimal mixture ratio of water for the water-hardening polyurethane waterproofing materials. Therefore, workers and construction workers are relying on their hands-on-skills and experience to determine this ratio and are not able to obtain a consistent performance quality out of these materials. Therefore, for the establishment of a board applicability of the water-hardening polyurethane waterproofing methods in construction sites, this study objectively analyzes the changes in the performance of these materials depending on the changes of the water mixture ratio and attempts to procure the optimal ratio on the basis of forming a provisionary standard. The study prepares mixtures of varying ratio(no water added, 5, 10, 15, 20, 25, 30, 40 and 50) and conducts comparative analysis respective mixtures' performances and their changes in the physical properties in an objective manner and proposes a provisional optimal value that can serve as a data base that can be used as a reference for future studies.

Effect of Coating Materials for Steel on the Threshold of Corrosive Amount of Airborne Chlorides and the Evaluation of Their Corrosion Speeds (강재마감별 부식개시 임계 비래염분량 및 부식속도 평가)

  • Cho, Gyu-Hwan;Lim, Myung-Hyun;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.143-151
    • /
    • 2015
  • Many studies have investigated the airborne chlorides that can weaken the overall durability of the concrete structures due to the corrosion of steel materials, but most of the studies have aimed to examine weathering by exposing various construction materials to the actual oceanic environment. However, with the exposure test, it was difficult to find the threshold of precise corrosive amount of airborne chlorides due to diverse deteriorating environmental factors such as ultraviolet ray, acid rain, floating material from industrial pollution as well as airborne chlorides. Therefore, in this study, an airborne chloride simulator was set up, in oder to conduct a corrosion accelerating test for steels coated by five different finishing materials. As results, it was found that the corrosion began to be observed at $0.58{\sim}0.73mg/dm^2$ for no-coated steel, at $7.89{\sim}8.46mg/dm^2$for urethane-coated steel, at $57.95{\sim}69.48mg/dm^2$ for red lead-coated steel, and at $80.73{\sim}89.35mg/dm^2$ for stainless-coated steel, respectively. Hence, these specific data can be considered as the threshold ranges of corrosion for each coating material for steel.