• 제목/요약/키워드: upper differential pressure

검색결과 20건 처리시간 0.029초

초고층 건축물에서 급기가압제연이 연돌효과에 미치는 영향 (The Influence on the Stack effect that Pressure differential system to smoke control in High-rise buildings)

  • 임채현;박용환
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.235-238
    • /
    • 2008
  • High-rise buildings with stack effect caused by the foreclosure, which significantly delayed the spread of a fire in effects of these stack effect driving force said. In this research on the stack effect of the lobby if the pressurization of the stairwell analysis of the pressure distribution of the CONTAMW. Overall, the pressurization of the lobby makes it stairwell amount of pressure(+) to the zone in pressure designed to prevent the spread of smoke control performance and found that, the way a normal state and sub-pressurization in the stairwell with stack effect of the turbulence Such as the formation of the upper flow, but, in the upper atmosphere with pressurization was formed by the underlying trend.

  • PDF

곡률 반경이 큰 환상관 간극에서 CCFL에 대한 실험 연구 (An Experimental Study on the CCFL in Narrow Annular Gaps with Large Diameter)

  • 이승진;정지환;박래준;김상백;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.795-800
    • /
    • 2000
  • A CCFL(Counter Current Flow Limit) test have been performed in narrow annular gaps with large diameter, because it has been confirmed that the CCFL phenomena affected the critical power in hemispherical narrow gap geometries from the SONATA(Simulation Of Naturally Arrested Thermal Attack)-IV (In-Vessel)/VISU(Visualization)-II experiments. The objectives of the CCFL experiments are to investigate the small gap sizes(1, 2mm) effect on CCFL under the large diameter condition and to confirm the findings of the VISU-II study that global dryout in hemispherical narrow gaps was induced by the CCFL. The test section was made of acrylic resin to allow visual observation on the two-phase flow behaviors inside annular gaps. It was observed from visualization that a part of water supplied was accumulated in the upper plenum and a significant increase in the differential pressure across the gap was occurred, which was the definition of the CCFL occurrence in this experimental study. From the experimental results in annular gap with large diameter it can be known that an increase in the differential pressure was not big at small air flow-rates. When the CCFL was occurred, the differential pressure across gaps was increased significantly and a water accumulated in the upper plenum. The occurrence of CCFL was correlated using the Wallis parameter.

  • PDF

원자력발전소의 증기발생기 수위계측 오차 원인분석 (Cause Analysis of Level Measurement Error in Steam Generator of Nuclear Power Plant)

  • 이광대;오응세;양승옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.591-593
    • /
    • 2006
  • The differential pressure method has been used in the level measurement of steam generator in nuclear power plant. Two sensing lines from a steam generator to a pressure transmitter are needed to measure the high pressure and low pressure. The fluid conditions in the sensing line require the uniform phase with no bubbles and the slope of sensing line should be installed with forward slope. The expansion of the bubble volume according to the upper pressure and the reverse slope of sensing lines explain how the level errors took place.

  • PDF

연돌효과가 급기가압 제연시스템에 미치는 영향에 대한 현장실험 (Field Experiment on Influence of Stack Effect to Pressure Differential System for Smoke Control)

  • 김정엽
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.194-200
    • /
    • 2008
  • 고층건물에서 급기가압 제연시스템과 같이 연기제어를 위해 제연구역에서의 압력차를 이용하는 제연시스템을 성공적으로 설계하고 운영하기 위해서는 건물내 압력형성에 영향을 미치는 건축적 요인들을 검토해야 하며 그중 큰 영향을 발휘하는 요인이 연돌효과이다. 본 연구에서는 고충건물의 피난환경과 제연시스템에 대해 연돌효과가 미치는 영향을 검토하기 위해서 여름과 겨울철에 각각국내 고층건물을 대상으로 급기가압 제연시스템을 가동하면서 피난계단, 부속실 및 거실에서의 압력변화를 측정하고 분석하였다. 연돌효과의 영향이 커지는 겨울철의 경우 급기가압 제연시스템이 가동되면 부속실에서 계단쪽으로의 누기현상과 연돌효과가 합쳐지면서 고층부의 계단실내 압력이 크게 상승하여 재실자가 대피를 위해 피난문을 열고자 할 때 문제가 발생할 수 있다.

Maxwell nanofluid flow through a heated vertical channel with peristalsis and magnetic field

  • Gharsseldien, Z.M.;Awaad, A.S.
    • Advances in nano research
    • /
    • 제13권1호
    • /
    • pp.77-86
    • /
    • 2022
  • This paper studied the peristaltic transport of upper convected Maxwell nanofluid through a porous medium in a heated (isothermal) symmetric vertical channel. The nanofluid is assumed to be electrically conducting in the presence of a uniform magnetic field. These phenomena are modeled mathematically by a differential equations system by taking low Reynolds number and long-wavelength approximation, the yield differential equations have solved analytically. A suggested new technique to display and discuss the trapping phenomenon is presented. We discussed and analyzed the pumping characteristics, heat function, flow velocity and trapping phenomena which were illustrated graphically through a set of figures for various values of parameters of the problem. The numerical results show that, there are remarkable effects on the vertical velocity, pressure gradient and trapping phenomena with the thermal change of the walls.

순환유동층 보일러에서 무연탄-유연탄의 혼합연소 특성 (Co-combustion Characteristics of Mixed Coal with Anthracite and Bituminous in a Circulating Fluidized Bed Boiler)

  • 정의대;문승재
    • 플랜트 저널
    • /
    • 제6권2호
    • /
    • pp.70-77
    • /
    • 2010
  • This study investigated the characteristics of co-combustion of mixed anthracite (domestic and Vietnam) and bituminous coal (Sonoma, Australia) at circulating fluidized bed boiler in Donghae thermal power plant when mixing ratio of bituminous coal is variable. Co-combustion of bituminous coal contributes to improvement in general combustion characteristics such as moderately retaining temperature of furnace and recycle loop, reducing unburned carbon powder, and reducing discharge concentration of NOx and limestone supply owing to improvement in anthracite combustibility as the mixing ratio was increased. However, bed materials were needed to be added externally when the mixing ratio exceeded 40% because of reduction in generating bed materials based on reduction in ash production. When co-combustion was conducted in the section of 40 to 60% in the mixing ratio while the supplied particles of bituminous coal was increased from 6 mm to 10 mm, continuous operation was shown to be possible with upper differential pressure of 100 mmH2O (0.98 kPa) and more without addition of bed materials for the co-combustion of mixed anthracite and bituminous coal (to 50% or less of the ratio) and that of domestic coal and bituminous coal (to 60% of the ratio).

  • PDF

소아의 구토에 대한 방사선학적 진단 (Radiological Diagnosis of vomitting in infant and children)

  • 김인원
    • 한국건강관리협회지
    • /
    • 제1권1호
    • /
    • pp.21-25
    • /
    • 2003
  • Vomiting in pediatric patient is frequently encountered problem in emergency room or outpatient clinic. In differential diagnosis, age of the patient or accompanying symptoms should be considered in the differential diagnosis. Accurate diagnosis is very important because surgical treatment is necessary in some of the conditions. Imaging diagnosis of conservative modality such as upper gastrointestinal series or colon study is still important radiological examination in the initial differential diagnosis, but recently ultrasonography offers accurate diagnosis in many situations. The cause of vomiting in pediatric are diverse according to the age group :neonatal sepsis, necrotizing enterocolitis, or hypertrophic pyloric stenosis in neonates : gastroesophageal reflux, viral enteritis, or intussusception in infant: midgut volvulus, appendicitis, metabolic disorders, or increased intracranial pressure also an be the cause. knowledge of radiological findings of normal gastrointestinal tract is important to recognize abnormalities. A discussion of radiological findings in variable surgical conditions to present as vomiting in pediatric patients is offered.

  • PDF

특별피난계단 부속실 제연설비의 방연풍속 기류특성에 관한 실험적 연구 (Experimental Study on Features of Air Egress Velocity in Vestibule Pressurization System)

  • 류성호;이수경;홍대화;윤명오;최금란;박재현
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.79-86
    • /
    • 2010
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템의 방연 풍속 기류 가화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 거실 방향으로 정상적으로 형성되지 않고 부속실 내부로 역류되는 현상을 개선하기위해 실 모형실험을 통해 출입구 상부로 역류하지 않는 조건을 개발하였다. 부속실 바닥 면적이 $2m^2$$4m^2$인 두개의 실물 모형을 제작하여 실험을 실시한 결과, 방연풍속의 기류 특성은 바닥 면적이 $2m^2$인 경우 심하게 출입문 상부로 기류가 역류되었다. 다만, 급기댐퍼의 설치위치가 출입문 맞은편의 경우 날개각도가 45도 상향인 경우는 출입문 상부로는 역 기류 현상은 없었지만 하부로는 일부 역류 되었다. 부속실 면적이 $4m^2$ 인 경우는 출입문에서 거실방향으로 정상적인 기류 분포를 보였다. 부속실 바닥 면적이 작게 설계될 경우에는 성능위주 설계가 될 수 있도록 하여야 한다.

수직관에서 2상선회유동이 보이드분포와 압력강하에 미치는 영향 (The Effects of Two - Phase Swirling Flow on Void Distribution and Pressure Drop in a Vertical Tube)

  • 김인석;손병진;신현동;곽기태
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.190-201
    • /
    • 1989
  • This experimental investigation has been conducted to determine the effects of swirling angle and flow patterns on distributions of void fraction, bubble velocity and two-phase pressure drop in a vertical straight tube. Swirling angles of $0^{\circ}$ (non swirling), $30^{\circ}$, and $45^{\circ}$ were tested with air-water two components over a range of superficial air velocities. A transparent lucite tube of 38mm in internal diameter was used for the test section. The void fraction and bubble velocities were measured by means of a optical fiber probe at the upper part of the swirler in the test section. Pressure drops which seem to be closely related with flow patterns and swirling angle were measured by a differential pressure transducer. It is shown that the probability density functions of pressure drop demonstrate peculiar features for both swirling angles and flow patterns, whereas the distributions of void fraction and bubble velocities are parabolic and flat shape in the vicinity of tube center, respectively except bubbly flow in any swirling angle cases, and the void fraction increases with increasing swirling angle around the center of tube.

  • PDF

대심도 준설 매립지반에서의 층별침하 계측관리에 관한 사례 연구 (Instrumentation Management of Differential Settlement of the Deep Soft Ground with Dredged Clay Reclaimed in the Upper)

  • 김태형;강승찬;장지건;허성훈
    • 한국지반신소재학회논문집
    • /
    • 제22권1호
    • /
    • pp.87-96
    • /
    • 2023
  • 상부에 준설매립점토층이 존재하고 점토층이 두껍게 분포되어 있는 부산항 신항만에서 측정된 지표침하 값과 층별침하 값은 많은 차이가 있다. 이런 결과의 원인과 해결방안을 찾기 위하여 연약지반 개량에 사용된 층별침하계의 실태, 층별침하계 형식별 특성, 설치방법, 계측 빈도, 계측데이터 관리방안, 결과의 정리 및 분석 등에 대해 고찰해 보았다. 대변형이 발생하는 대심도 연약지반 개량공사에서 스크류타입의 층별침하계의 경우 휨 변형이 다른 형식의 계측기에 비해 적어 망실의 우려도 적고 각 지층별로 천공하여 계측기를 설치하므로 데이터의 신뢰도도 상대적으로 높다. 정도 높은 침하계측 자료의 양이 많을수록 침하분석 정밀도는 높아지므로 표준시방서에서 제시한 계측빈도보다 기준을 강화하여 관리가 필요하다. 층별침하계 계측데이터의 관리는 측점별 지표침하량, 층별침하량, 간극수압계 침하량과 같이 해당 구간의 침하량과 성토고의 경시 그래프 작성하여 관리하는 것이 바람직하다. 침하분석은 압축특성이 다른 다층지반일 경우 층별침하 데이터를 이용하여 각 지층별 압밀특성을 각각 산정하여 침하분석이 이루어지는 게 더 타당하다.