• 제목/요약/키워드: uplift capacity

검색결과 104건 처리시간 0.023초

Simple Evaluation Method of Uplift Resistance for Frictional Shallow Anchors in Rock

  • Kim, Daehong;Lee, Seungho
    • 한국지반환경공학회 논문집
    • /
    • 제23권1호
    • /
    • pp.15-23
    • /
    • 2022
  • This paper presents the results of full-scale load tests performed frictional anchors to various lengths at several sites in Korea. Various rock types were tested, ranging from highly weathered shale to sound gneiss. In many tests, rock failure was reached and the ultimate loads were recorded along with observations of the shape and extent of the failure surface. Laboratory tests were also conducted to investigate the influence of the corrosion protection sheath on the bond strength. Based on test results, the main parameters governing the uplift capacity of the rock anchor system were determined. By evaluation of the ultimate uplift capacity of anchor foundations in a wide range of in situ rock masses, rock classification suitable for structural foundation was developed. Finally, a very simple and economical design procedure is proposed for rock anchor foundations subjected to uplift tensile loads.

매입기초와 토질에 따른 인발저항력 특성 (Characteristics of Uplift Capacity of a Embedded Foundation and Soil Type)

  • 임성윤;김유용;유석철;김명환
    • 한국농공학회논문집
    • /
    • 제61권3호
    • /
    • pp.23-30
    • /
    • 2019
  • In this study, we evaluated the applicability of proper embedded depth of fillings by examining the uplift resistance using spiral foundation and top base foundation. As a result of the model test, the maximum uplift resistance increased with the embedded depth. The maximum uplift resistance of each region was found to be 50cm depth. The spiral foundation was 335.14N of Sancheong, 312.32N of Seongju, 403.94N of Wanju, and the top base foundation was 745.06N of Sancheong, 1028.82N of Seongju and 950.76N of Wanju. The yield point after the elastic section in the stress-displacement graph of the top base foundation was calculated as the maximum uplift resistance. For this reason, farmers do not actually use top bases foundation. Therefore, it was considered that the additional load increase due to slip connector will not occur. Model test results show that the maximum uplift resistance increases with the purlinss installed under the ground. Therefore, additional comparative studies through purlins installation will be needed.

Study on uplift performance of stud connector in steel-concrete composite structures

  • Ju, Xiaochen;Zeng, Zhibin
    • Steel and Composite Structures
    • /
    • 제18권5호
    • /
    • pp.1279-1290
    • /
    • 2015
  • The main role of studs, which act as connectors of the steel-concrete composite structures, is to ensure that the steel and the concrete work together as a whole. The studs in steel-concrete composite structures bear the shearing force in the majority of cases, but in certain locations, such as the mid-span of a simply supported composite beam, the studs bear axial uplift force. The previous studies mainly focused on the shearing performance of the stud by some experimental and theoretical effort. However, rare studies involved the uplift performance of studs. In this paper, the single stud uplift test on 10 composite specimens was performed. Meanwhile, based on the test, numerical analysis was introduced to simulate the concrete damage process due to the stud uplifted from concrete. The static ultimate bearing capacity, under which the stud connector was pulled out from the damaged reinforced concrete, is much larger than the cyclic ultimate bearing capacity, under which the weld joint between stud and steel plate fractured. According to the fatigue test results of 7 specimens, the fatigue S-N curve of the construction detail after minus 2 times standard deviation is $logN=24.011-9.171\;log{\Delta}{\sigma}$, the fatigue strength corresponding to $2{\times}10^6$ cycles is 85.33 MPa.

Ultimate Uplift Capacity of Circular Anchors in Layered Soil

  • Shin, Eun-Chul;Das, Braja-M
    • 한국지반공학회지:지반
    • /
    • 제14권3호
    • /
    • pp.63-72
    • /
    • 1998
  • 단단한 모래층 하부에 위치한 연약점토층에 설치된 수평 원형 앵커들의 극한 상향 인발력에 대한 실내모형실험 결과들을 제시하였다. 점토층의 한계매립비에 대한 효과를 평가하였다. 순극한상향인발력을 도출할 수 있는 단순화한 방법을 제시하였다.

  • PDF

모래 지반에 위치한 말뚝의 인발 저항력 (Determination of Uplift Capacity of Pile in Sand)

  • 이용훈;권오균;김명모
    • 대한토목학회논문집
    • /
    • 제13권2호
    • /
    • pp.229-235
    • /
    • 1993
  • 본 연구에서는 모래 지반에 위치한 말뚝의 인발저항력을 산정하는 기존의 방법들을 검토한 다음, 각 방법의 한계점을 분석하였다. 그리고, 보다 정확한 인발저항력을 산정하는 방법을 제시하였다. 기존의 실험 결과들과 이론적 방법들에 의한 결과들을 비교한 결과, Meyerhof 방법은 조밀한 모래 지반에서 인발저항력을 과소 평가하지만, 중간 정도나 느슨한 모래 지반에서 인발저항력을 과대 평가하는 경향을 나타내고 있다. Chattopadhyay & Pise 등이 제안한 방법은 기존의 방법들에 비하여 정확성이 있었으나, 느슨한 사질토 지반의 경우에, 아직도 상당한 차이를 나타내었다. 이에 본 연구에서는 기존의 실험 결과에 보다 가까운 계산 결과를 얻을 수 있도록 Chattopadhyay와 Pise가 제안한 방법을 수정 제안하였다.

  • PDF

Numerical analysis of an innovative expanding pile under static and dynamic loading

  • Abdullah Cheraghi;Amir K. Ghorbani-Tanha
    • Geomechanics and Engineering
    • /
    • 제32권4호
    • /
    • pp.453-462
    • /
    • 2023
  • Designing pile foundations subjected to the uplift forces such as buildings, oil platforms, and anchors is becoming increasingly concerned. In this paper, the conceptual design of a new type of driven piles called expanding pile is presented and assessed. Some grooves have been created in the shaft of the novel pile, and some moveable arms have been designed at the pile tip. At first, static analyses using the finite element method were performed to evaluate the effectiveness of the innovative pile on the axial bearing capacity. Then its effect on seismic behavior of moment frame is considered. Results show that the expanding arms were provided an ideal anchorage system because of the soil's noticeable locking-up effect increasing uplift bearing capacity. For example at the end of the static tensile loading procedure, displacement decrement up to 55 percent is observed. In addition, comparing the uplift bearing capacity of the usual and new pile with different lengths in sand and clay layers shows noticeable effect and sharp increase up to about two times especially in longer piles. Besides, a sensible reduction in the seismic response and the stresses in the beam-column connection between 23-36 percent are achieved that ensures better seismic behavior of the structures.

조밀한 사질토지반에서 경사로 설치된 그룹 마이크로파일의 인발지지력 평가방법 (Evaluation Method for Uplift Load-carrying Capacity of Inclined Group Micropiles in Dense Sand)

  • 경두현;김가람;김인철;이준환
    • 한국지반공학회논문집
    • /
    • 제33권1호
    • /
    • pp.67-77
    • /
    • 2017
  • 본 연구에서는 단일 마이크로파일의 인발재하시험과 그룹 마이크로파일 인발재하시험 결과를 토대로 마이크로파일의 설치각도와 설치간격에 따른 인발지지특성을 확인하였다. 또한 FHWA(2005)의 방법과 Madhav(1987)의 방법을 토대로 지지력평가방법을 제안하고, 시험결과와 비교하여 그 적정성을 검토하였다. 시험결과, 단일 및 그룹마이크로파일의 인발지지력이 설치각도 30도까지 증가하는 것으로 나타났으며, 설치간격이 증가함에 따라 그 값이 다소 증가되는 것으로 나타났다. 제안된 FHWA(2005)의 방법의 경우, 수정된 방법을 통한 예측 값이 설치각도 15도의 5D조건까지 유사한 것으로 나타났다. 반면, 제안된 Madhav(1987)의 방법의 경우에는 모든 설치조건에서의 측정값과 수정된 방법을 통한 예측 값이 비교적 유사한 것으로 나타났다.

점토 지반에서 인발속도에 따른 판앵커의 극한 인발저항력 분석 (Analysis of Ultimate Capacity of Plate Anchor on Loading Rate Capacity in Clay)

  • 서영교;유동만
    • 한국해양공학회지
    • /
    • 제27권3호
    • /
    • pp.15-21
    • /
    • 2013
  • Anchors are primarily designed and constructed to resist outwardly directed loads imposed on the foundation of a structure. These outwardly directed loads are transmitted to the soil at a greater depth by the anchors. Buried anchors have been used for thousands of years to stabilize structures. Various types of earth anchors are now used for the uplift resistance of transmission towers, utility poles, submerged pipelines, and tunnels. Anchors are also used for the tieback resistance of earth-retaining structures, waterfront structures, at bends in pressure pipelines, and when it is necessary to control thermal stress. In this research, we analyzed the uplift behavior of plate anchors in clay using a laboratory experiment to estimate the uplift behavior of plate anchors under various conditions. To achieve the research purpose, the uplift resistance and displacement characteristics of plate anchors caused by the embedment ratio, plate diameter, and loading rate were studied, compared, and analyzed for various cases.

기초형식 및 지반조건에 따른 하우스파이프기초의 인발저항력 특성 (Characteristics of Uplift Capacity of House Pipe Foundation according to Foundation Types and Soil Conditions)

  • 송창섭;장웅희;최득호;김정철
    • 한국농공학회논문집
    • /
    • 제62권1호
    • /
    • pp.117-126
    • /
    • 2020
  • The area of facility horticulture in Korea is increasing rapidly, the single-span pipe house which uses galvanized steel pipe as the main rafters occupies 78.7% of the facility area. Lightweight structures such as the single-span pipe house are vulnerable to meteorological disasters such as strong winds, economic losses of the state, local governments and farmers are continuing as construction does not meet the design standards. In order to minimize economic losses in the horticultural specialty facilities sector, the Rural Development Administration has been operating the horticultural disaster resilient standard for horticultural specialty facilities since April 2007. The only standard for the pipe connector is the disaster resilient standard, there is no standard for the uplift capacity of the house pipe foundation and the research on it is also insufficient. The purpose of this study is to investigate the characteristics of uplift capacity according to the foundation type, compaction ratio and embedded depth through soil box test. The results of the maximum uplift capacity according to the type, compaction ratio and embedded depth can be used as the basic data for the basic design of the pipe house conforming to the disaster resilient standard. Due to the limitation of soil box test, it may be different from the behavior of pipe house installed on site. In the future, the field test and the actual pipe house should be made and supplemented by comparing this result with the field test values.

인발력을 받는 Kaolinite 지반의 장기변위 특성에 관한 연구 (A Study on the Characteristics of Creep in Kaolinite Soil Subjected to Uplift Capacity)

  • 이준대;최기봉
    • 한국안전학회지
    • /
    • 제14권2호
    • /
    • pp.116-121
    • /
    • 1999
  • When plate anchors are embedded in soft clay, they may undergo a deformation under the pressure of sustained load. The critical depth at which the transition from a shallow to a deep anchor takes place depends on the properties of soil. Laboratory model tests were performed for the short-term net ultimate uplift capacity of a circular anchors with respect to various embedment depths and moisture content in saturated kaolinite. The tests have been conducted with the anchor at two different moisture contents. Based on the model test results, empirical relationships between the net load, rate of strain, and time have been developed. In creep tests of kaolinite for load versus ultimate uplift capacity, the displacement of plate anchors rapidly increases during the primary stage but thereafter becomes constant over a period of time.

  • PDF