This paper presents a new type of hydraulic servo chllinder which is characterized by its simple construction and an ubtegrated feedback mechanism. Piston position of the cylinder is controlled by eletrical input and mechamical feedback deduced from its own structure. Hydraulic pressure in each cylinder room is controlled by a poppet valve. The poppet is activated by a solenoid and is linked to the piston. Solenoid input current pulls up the poppet, which results in pressure drop and thus piston motion. The piston motion generates pull down force on the poppet by the linkage and the motion stops at equilibrium. In that way the piston position is controlled by an expernal input current. Characteristics of the servo cylinder is verified by stability analysis, tranient vehavior and steady state positing for step input. Design parameter analyses have been executed by derivation of analytical approximate solutions and by computer simulations. A prototype hydraulic servo cylinder is developed and tested. The experimental results show successful function of the servo cylinder and consistency with the theoritical results.
This paper describes the results of a study on the unmanned maintenance robot that simultaneously performs the cleaning and inspection of the photovoltaic panels. The robot has a special adsorptive device, an infrared sensor, a vacuum level sensor and a camera. The robot uses two SSC (Sliding Suction Cup) adsorptive devices to move up and down the slope. First, the forces generated when the robot moves up the slope are mechanically analyzed, and the required design and control of the adsorption system are suggested. The robot was designed and manufactured to operate stably by using the presented results. Next, the normal force between the panel and the wheel was measured to confirm that the robot was manufactured and operated as intended, and the robot motion was tested on the inclined panel. It has been proven that robots are well designed and built to clean and inspect sloped panels.
본 논문에서는 표면 근전도 신호를 사용하여 손목 움직임의 동작을 분류하기 위해 인공 신경 회로망(ANN : Artificial Neural Network)기반의 동작 분류 알고리즘을 제안한다. 손목 움직임에 무리가 없는 20~30대 성인 26명을 대상으로 척측 수근 굴근과 척측 수근 신근에 부착한 2채널의 전극으로부터 표면 근전도 신호를 취득하고, 취득한 근전도로부터 손목의 굴곡, 신전, 내전, 외전, 휴식 다섯 동작을 인식한다. 빠른 처리 속도를 위해 획득한 신호로부터 시간 영역에서의 특징점을 추출하고 ANN을 이용한 동작 분류에 사용된다. 특징점으로 DAMV, DASDV, MAV, RMS를 사용하였으며, ANN 기반의 동작 분류의 인식율은 DAMV는 98.03%, DASDV는 97.97%, MAV는 96.95%, 그리고 RMS는 96.82%의 정확도를 나타낸다.
This paper describes the results of a study on the unmanned cleaning robot that performs the cleaning of the floating photovoltaic panels. The robot uses two SSC (Sliding Suction Cup) adsorptive devices to move up and down the slope. First, the forces generated when the robot moves up the slope are mechanically analyzed. The robot was designed and manufactured to operate stably by using the presented results. Next, the robot motion was tested on the inclined panel. It has been proven that robots are well designed and built to clean sloped panels.
In this paper, an assistive device for a knee joint to help a disabled person to stand up by supporting power is presented. The device is designed and controlled by using damping characteristics of the MR (Magneto-Rheological) damper. The MR damper helps the person to sit slowly and safely. A DC motor supports muscle power in the case of standing motion. Thus the device helps the disabled person to sit down and stand up. Through the experiments, it is feasible that an assistive device can help the disabled person to standup according to the foot pressure change.
본 논문에서는 안드로이드 플랫폼 기반의 GRS칩 구동 JNI 코드 응용 SW 설계 안드로이드 플랫폼 기반 동작 제스처 프레임 모듈 설계 제작하였다. 안드로이드 기반 모듈 설계, 안드로이드 기반 모듈 구현, 안드로이드 기반 기능 모듈 구현 설계로 응용애플리케이션 기반 네트워크 지원 API 기술 제안한 직렬 데이터 수신 모듈 설계를 하였다. 안드로이드 OS의 애플리케이션을 통해 무선 통신 디바이스로부터 데이터를 수신하기 위한 직렬 통신 드라이버, 라이브러리, 프레임워크의 클래스와 같은 안드로이드 애플리케이션을 통해 센서의 데이터 정보를 확인할 수 있었다. 또한 안드로이드에서의 어플리케이션들은 자바를 이용하여 좌우상하 4방향의 동작 제스처를 판단할 수 있는 응용 SW를 구현하였다.
연구 목적: 본 연구에서는 수술가이드를 이용한 무피판 임플란트 술식에서 임플란트 드릴링이 열발생에 미치는 효과를 측정하였으며 드릴링 방법에 따른 온도 차이를 측정하고자 하였다. 연구 재료 및 방법: 하악 양측 제 1 대구치와 제 2 대구치가 없는 실험 모델에서 피판을 거상하는 임플란트 수술(실험A군)과 수술가이드를 이용한 무피판 임플란트 수술(실험B군), 그리고 핸드피스의 상하 수직 움직임을 제한한 후 수술가이드를 이용하여 무피판 임플란트 수술(실험C군)을 각각 진행하여 온도 측정을 하였다. 임플란트 드릴링 시 온도 측정은 thermocouple과 열전식 온도 기록계(Yokogawa, Tokyo, Japan)를 이용하여 측정하였다. 온도 측정 위치는 최종 임플란트 드릴(직경 3.8 mm)의 경계부에서 0.5 mm 떨어진 곳에서 3 mm 깊이(설측)와 6 mm 깊이(협측)로 하였다. 측정된 온도 값을 이용하여 종속변수인 온도가 정규분포 하는지를 검정하기 위해 Kolmogorov-Smirnov test를 거쳐 확인한 후 세 수술 방법 간의 평균 온도 차이를 검정하기 위해 independent t-test로 분석하였다. 결과: 피판을 거상하고 드릴링을 한 수술군(실험A군)에서 평균 온도는 $27.2^{\circ}C$($SD{\pm}2.1^{\circ}C$)를 보였고 피판을 거상하지 않고 드릴링을 한 수술군(실험B군)에서 평균 $27.5^{\circ}C$($SD{\pm}2.3^{\circ}C$)를 나타냈다. 이들 두 수술 방법 간 온도비교에서는 통계학적으로 유의한 차이를 보이지 않았다. 수술가이드를 이용하여 무피판 수술 시 상하 수직 움직임(upand-down pumping motion)이 없이 드릴링을 시행한 수술군(실험C군)에서 평균온도는 $37.0^{\circ}C$($SD{\pm}3.4^{\circ}C$)을 보였다. 이를 상하 수직 움직임으로 드릴링을 한 무피판 임플란트 수술군(실험B군)과 비교 시 통계학적으로 유의한 온도 차이를 보였다. 결론: 수술가이드를 이용하여 무피판 임플란트 수술 시 핸드피스를 상하 수직 움직임으로 드릴링을 시행하면 피판을 거상하여 수술할 때와 온도차이가 발생하지 않으나, 상하 수직 움직임 없이 드릴링을 시행하면 드릴링 시 높은 온도 상승을 보인다.
Journal of Advanced Marine Engineering and Technology
/
제39권8호
/
pp.821-827
/
2015
This study concentrates on a wave energy converter with floaters that extracts the ocean's energy by moving up and down with the wave motion. The floater is connected to an arm structure, including a hydraulic cylinder that drives a hydraulic generator. This study focuses on a structural analysis of the floater unit, including arm and cylinder components, platform and jack-up system, along with spud columns. Previous studies have been conducted for miniature models for experimentation, but this study focuses on the full-scale model structural analysis. Static structural analysis is conducted using fine numerical grids. Due to the complexity of the whole model, it is analyzed in separate pieces. The floater unit, with arm and cylinder, are combined into one system. The platform is analyzed separately as a single system. There are four jack-up systems for each spud column; only one jack-up system is analyzed, as uniform loads are assumed on each system. There are several load cases for each system, all of which are analyzed thoroughly for stress (von Mises, shear, and normal) and deformation. Acceptable results were obtained for most of the components; unsafe components were redesigned.
본 논문에서는 교류전압 인가시 모의 GIS내에 존재하는 금속이물의 거동현상에 대해 연구하였다. 평행평판 전극을 내장한 가스챔버를 설계·제작하고, 전국내 선형 및 구형의 금속이물에 대해 부상전압을 계산 및 측정하였다. 또한 각각의 금속이물에 대전되는 전하량을 계산하였다. 고속카메라를 이용하여 금속이물의 종류 및 인가전압에 따른 거동양상과 부상시간, 부상높이 등의 거동특성을 분석하였다. 전계인가시 금속이물의 대전 전하량은 금속이물의 크기에 따라 증가하며, 부상전압은 서형 및 구형 금속이물의 직경에 큰 양형을 받는 것으로 나타났다. 금속이물의 부상이후 부상전압 부근의 전압에서의 선형 금속이물은 후 전극과 거의 수직인 상태로 상하 왕복운동을 하며, 거의 수직상태로 움직이는 거동 형태를 나타내었다. 절연파괴전압에 가까운 전압에서는 금속이물은 부상 중에 수회 수직회전을 반복하며, 장시간 부유하였다.
PURPOSE: This study was conducted to examine the effects of motion taping on the effects of lumbar stabilization exercise. METHODS: The subjects of this study were 24 normal males with no problem in their nervous systems or musculoskeletal systems. The subjects were randomly assigned to a control group of 12 subjects and an experimental group of 12 subjects. The control group was applied with lumbar stabilization exercise while the experimental group was applied with lumbar stabilization exercise after being attached with tapes. The intervention period was four weeks in total and the subject underwent the exercises three times per week. The exercise time per session was set to one hour in principle consisting of warm-up exercise and cool-down exercise for 10 minutes each and main exercise for 40 minutes. Lumbar muscle strength was measured as a factor to examine the effects of lumbar stabilization exercises. RESULTS: The control group showed an increase in lumbar muscle strength from $111{\pm}6.30kg$ to $113{\pm}6.23kg$ and the experimental group showed an increase in lumbar muscle strength from $108{\pm}6.46kg$ to $116{\pm}5.21kg$. The increases shown by both groups were statistically significant and the experimental group that was applied with motion taping showed a larger increase in lumbar muscle strength compared to the control group. CONCLUSION: Lumbar stabilization exercise is considered to be good for lumbar stability and muscle strengthening and lumbar stabilization exercise applied with motion taping is considered to show larger effects for muscle strengthening and the improvement of lumbar functions.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.