• Title/Summary/Keyword: up-and-down motion

Search Result 193, Processing Time 0.026 seconds

Kinematical Analysis of Up-Down Motion in Ski Simulator (스키 시뮬레이터 업-다운 동작의 운동학적 분석)

  • Nam, Chang-Hyun;Woo, Byung-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.41-49
    • /
    • 2007
  • This study was to investigate the kinematical analysis using ski simulator. Twelve people(six skilled, six unskilled) participated in the experiment. Each phase of motion time was slight differences between the skilled group and the unskilled group but not significant difference in statistics. In displacement of vertical on COG(Center of Gravity), left and right down motion showed significant difference between group. In velocity of horizontal on COG, both left and right down motion showed significant difference between group, and up motion of between down motion showed significant difference. In displacement of angle on ankle, knee, hip joint almost showed significant difference between group. Almost in body position was lower skilled group than unskilled group.

EFFECT OF ANTICURVATURE FILING METHOD ON PREPARATION OF THE CURVED ROOT CANAL USING PROFILE (PROFILE을 이용한 근관형성 시 ANTICURVATURE FILING방법의 영향)

  • Song, Hyun-Ji;Chang, Ju-Hea;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.327-334
    • /
    • 2005
  • This study investigated the effect of anticurvature filing method on preparation of the curved root canal using ProFile. Thirty six resin blocks were divided equally into three groups by instrumentation motions: anticurvature filing motion. circumferential filing motion and straight up-and-down motion. Each resin block was sectioned at 8mm level from the apex and at the greatest curvature of the canal and reassembled in metal mold by a modified Bramante technique. All groups were instrumented with the ProFile system. At each levels. image of sectioned surface were taken using CCD camera under a stereomicroscope at $\times40$ magnification and stored. Distances of transportation at the inner and outer area of curvature and the centering ratio were determined and compared by statistical analysis. along with the assessment of the increase of root canal cross-sectional area. The results were as follows; 1. In all groups. there was no statistical difference in the mean increase of root canal cross-sectional area. the centering ratio. and the mean distances of transportation at the inner area of curvature at each level. 2. At 8mm level from the apex. the mean distances of transportation at the outer area of curvature decreases in following order anticurvature filing motion. circumferential filing motion. straight up-and­down motion but. no significant difference at the greatest curvature of the canal among three groups. Effect of anticurvature filing motion using ProFile does not seem to be different from other instrumentation motions at the inner area of curvature in curved root canal.

Wave energy conversion utilizing vertical motion of water in the array of water chambers aligned in the direction of wave propagation

  • Hadano, Kesayoshi;Lee, Ki Yeol;Moon, Byung Young
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.3
    • /
    • pp.239-245
    • /
    • 2017
  • As a new technical approach, wave energy converter by using vertical motion of water in the multiple water chambers were developed to realize actual wave power generation as eco-environmental renewable energy. And practical use of wave energy converter was actually to require the following conditions: (1) setting up of the relevant device and its application to wave power generation in case that severe wave loading is avoided; (2) workability in installation and maintenance operations; (3) high energy conversion potential; and (4) low cost. In this system, neither the wall(s) of the chambers nor the energy conversion device(s) are exposed to the impulsive load due to water wave. Also since this system is profitable when set along the jetty or along a long floating body, installation and maintenance are done without difficulty and the cost is reduced. In this paper, we describe the system which consists of a float, a shaft connected with another shaft, a rack and pinion arrangement, a ratchet mechanism, and rotary type generator(s). Then, we present the dynamics model for evaluating the output electric power, and the results of numerical calculation including the effect of the phase shift of up/down motion of the water in the array of water chambers aligned along the direction of wave propagation.

Pricing Outside Barrier Options

  • Lee Hangsuck
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.165-170
    • /
    • 2004
  • This paper will derive explicit unified pricing formulas for eight types of outside barrier options, respectively. The monitoring periods of these options start at an arbitrary date and end at another arbitrary date before maturity. The eight types of barrier options are up-and-in, up-and-out, down-and-in and down-and-out call (or put) options.

  • PDF

Biomechanical Assessment of Lifting Chair with Hip-up Function (힙업기능이 적용된 기립보조의자의 생체역학적 평가)

  • Bae, Ju-Hwan;Moon, In-Huyk
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.191-197
    • /
    • 2011
  • Lifting chair is a typical assistive product to aid for standing up and sitting down for persons with disability. It is particularly useful for the elderly persons whose muscular system is weakened by degenerative joint disease. This paper describes biomechanical assessments of lifting chair with hip-up function. In experiments we measured 3D motion and electromyographic(EMG) signal on the femoral muscle when subject performs the standing motion on the predetermined seat height. Based on assessment of the standing motion, we select the hip-up angle as 15 degrees to cover the relative femoral angle when EMG peak value is appeared. Using an implemented prototype lifting chair with hip-up function we perform standing experiments with five subjects. The experimental results show that the lifting and hip-up functions are effective to assist for standing up motion with less muscle force.

Steering Control Algorithm of an Up and Down Motion Robot Using a Quaternion with Spherical Cubic Interpolation (쿼터니언의 Spherical Cubic Interpolation 을 이용한 상하이송 로봇의 조향 방법에 관한 연구)

  • Chung W.J.;Kim K.J.;Kim S.H.;Kim H.G.;Seo Y.K.;Lee K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1832-1835
    • /
    • 2005
  • This paper presents the steering control algorithm of an up and down motion robot using a quaternion. The up and down motion robot is to be moved on an irregular floor that can inevitably result in the errors of both position and orientation. Especially the orientation error should be compensated every work in order to adjust the misaligned values of current orientation to those commanded values. In this paper, we propose a new steering control algorithm between the two values by using a quaternion with spherical cubic interpolation. The proposed algorithm is shown to be effective in terms of vibration when compared to a conventional simple compensation without interpolation, by using $MATLAB^{(R)}$ and $VisualNastran4D^{(R)}$

  • PDF

A Development of Single Action Press Robot (프레스 단동로봇의 개발)

  • 허성창;황병복
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.261-264
    • /
    • 1997
  • A single action press robot, which consists of a driving unit, rotator, up-down feed base and feed bar, is developed and applied for the press automation. The driving unit is made up with a face cam and blade cam, which have a phase angle. The feeding system consists of a double speed-up apparatus and linear motion guides, and has a fast motion characteristics. A horizontal feeding speed of the feed bar is increased twice by the double speed-up apparatus. The driving mechanism could be simplified due to the speed-up of the feeding unit.

  • PDF

Molecular Dynamics Simulation Studies of Zeolite A. Ⅵ. Vibrational Motion of Non-Rigid Zeolite-A Framework

  • 이송희;최상구
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.4
    • /
    • pp.422-428
    • /
    • 1998
  • In the present paper, we report a molecular dynamics (MD) simulation of non-rigid zeolite-A framework only as the base case for a consistent study of the role of intraframework interaction on several zeolite-A systems using the same technique in our previous studies of rigid zeolite-A frameworks. Usual bond stretching, bond angle bending, torsional rotational, and non-bonded Lennard-Jones and electrostatic interactions are considered as intraframework interaction potentials. The comparison of experimental and calculated structural parameters confirms the validity of our MD simulation for zeolite-A framework. The radial distribution functions of non-rigid zeolite-A framework atoms characterize the vibrational motion of the framework atoms. Mean square displacements are all periodic with a short period of 0.08 ps and a slow change in the amplitude of the vibration with a long period of 0.53 ps. The displacement auto-correlation (DAC) and neighbor-correlation (DNC) functions describe the up-and-down motion of the framework atoms from the center of α-cage and the back-and-forth motion on each ring window from the center of each window. The DAC and DNC functions of the framework atoms from the center of α-cage at the 8-ring windows have the same period of the up-and-down motion, but those functions from the center of 8-ring window at the 8-ring windows are of different periods of the back-and-forth motion.

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone (네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력)

  • Choi, Seok-Dong;Jin, Myoung-Uk;Kim, Ki-Ok;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.446-453
    • /
    • 2004
  • The aim of this study was to evaluate the shaping abilities of four different rotary nickel-titanium instruments with anticurvature motion to prepare root canal at danger zone by measuring the change of dentin thickness in order to have techniques of safe preparation of canals with nickel-titanium files. Mesiobuccal and mesiolingual canals of forty mesial roots of extracted human lower molars were instrumented using the crown-down technique with ProFile, $GT^{TM}$ Rotary file, Quantec file and $ProTaper^{TM}$. In each root, one canal was prepared with a straight up-and-down motion and the other canal was with an anticurvature motion. Canals were instrumented until apical foramens were up to size of 30 by one operator. The muffle system was used to evaluate the root canal preparation. After superimposing the pre- and post-instrumentation canal. change in root dentin thickness was measured at the inner and outer sides of the canal at 1. 3, and 5 mm levels from the furcation. Data were analyzed using two-way ANOVA. Root dentin thickness at danger zone was significantly thinner than that at safe zone at all levels (p < 0.05). There was no significant difference in the change of root dentin thickness between the straight up-and-down and the anticurvature motions at both danger and safe zones in all groups (p > 0.05). ProTaper removed significantly more dentin than other files especially at furcal 3 mm level of danger and safe zones (p < 0.05) Therefore, it was concluded that anticurvature motion with nickel-titanium rotary instruments does not seem to be effective in danger zone of lower molars.

Fatigue Life Prediction of Medical Lift Column utilizing Finite Element Analysis (유한요소해석을 통한 의료용 리프트 칼럼의 피로수명 예측)

  • Cheon, Hee-Jun;Cho, Jin-Rae;Yang, Hee-Jun;Lee, Shi-Bok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.337-342
    • /
    • 2011
  • Medical lift column controlling the vertical position while supporting heavy eccentric load should have the high fatigue strength as well as the extremely low structural deflection and vibration in order to maintain the positioning accuracy. The lift column driven by a induction motor is generally in a three-step sliding boom structure and exhibits the time-varying stress distribution according to the up-and-down motion. This study is concerned with the numerical prediction of the fatigue strength of the lift column subject to the time-varying stress caused by the up-and-down motion. The stress variation during a motion cycle is obtained by finite element analysis and the fatigue life is predicted making use of Palmgren-miner's rule and S-N curves. In order to secure the numerical analysis reliability, a 3-D FEM, model in which the detailed lift column structure and the fitting parts are fully considered, is generated and the interfaces between lift column and pads are treated by the contact condition.