• Title/Summary/Keyword: unpaved road

Search Result 39, Processing Time 0.034 seconds

Estimating Unsaturated Shear Strength and Yield Load of Compacted Aggregate Sub-base Materials (다져진 보조기층 재료의 불포화 전단강도 및 항복하중 평가)

  • Jeon, Hye-Ji;Park, Seong-Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4D
    • /
    • pp.571-576
    • /
    • 2011
  • In general, conventional road pavements are designed under the assumption that the shear strength of geomaterials are under saturated state. In reality, however, most of the pavement geomaterials exists under the unsaturated state. To deal with this gap between saturated and unsaturated conditions, in this paper, unsaturated shear strength was estimated using the results from the triaxial compression test and soil-water characteristics curves. Then, yield loads were assessed using 2-Dimensional finite element method with the selected nonlinear elastic model and the Mohr-Coulomb yield criteria. In addition, various unsaturated condition and surface layer effects on the yield load of granular materials were identified. Therefore, the results demonstrated would provide a possibility to estimate bearing capacity of paved or unpaved roads using unsaturated soil mechanics.

Study on the Convergent Life Evaluation due to the Bumper Configuration of Multipurpose Vehicle (다목적차량의 범퍼형상에 따른 융합적 수명평가에 관한 연구)

  • Lee, Jung-Ho;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.85-90
    • /
    • 2015
  • In this study, the life evaluation due to the structural configuration of bumper attached at the front side of ATV vehicle is studied on the basis of fatigue analysis. As the purpose of this study, the characteristic of bumper exposed on the repetitive loading condition like the vibration is understood. The position of crack happened at the fatigue situation is grasped in advance and complemented in advance. It is considered that the multipurpose vehicle is designed to not be driven on the paved general road but the rough road like the unpaved load. And the weak part of bumper is understood through the study of life evaluation on this driving environment. The durability can be improved by doing the safe design of automotive bumper on the basis of the analysis result. And it is possible to be grafted onto the convergence technique at design and show the esthetic sense.

A Method of Generating Trafficability Analysis Map for UGV Navigation (지상무인로봇의 경로계획을 위한 가동맵 생성 방법)

  • Chang, Hye Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.79-85
    • /
    • 2014
  • For the successful operation of unmanned ground vehicles(UGVs), optimal path planning should be considered with trafficability analysis, threat analysis, and so on. From among these, trafficability analysis is immensely important for safeness of UGVs especially in the case of driving the off-road such as unpaved road, grassland, and open fields. Geographical information has a pivotal role in extracting data and measuring cost for specified regions of interest. In this paper, we review possibilities to apply Land Cover Map(LCM) as a new, fundamental source and propose a new generation method of trafficability analysis map for optimal path planning of UGV. The simulation results show that the proposed method significantly improve the previous method by applying LCM either alone or in combination with the other GIS.

Verification of Reliable Blood Pressure Monitor in a Moving Ambulance during an Emergency (응급상황시 이송중인 구급차에서 신뢰할 수 있는 혈압계 검증)

  • Jeon, Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.91-97
    • /
    • 2022
  • The purpose of this study was to analyze the measurements of blood pressure and time using manual and automatic blood pressure monitors in various road conditions to verify reliable blood pressure monitor in a moving ambulance. First, the manual blood pressure monitor palpation on unpaved roads showed a systolic pressure deviation of 5 mmHg. However, the automatic blood pressure monitor showed two measurement failures, one reading failure, and the measured systolic pressure deviation was 35 mmHg. The measurement time was 102 seconds faster on average than the automatic blood pressure monitor. Second, the palpation of the manual blood pressure monitor while going over speed bumps remained constant at 130 mmHg. However, the automatic blood pressure monitor had a systolic pressure deviation of 52 mmHg. The measurement time was 61 seconds faster on average than the automatic blood pressure monitor. Finally, the manual blood pressure monitor palpation on the sharp curve road showed a systolic pressure deviation of 5 mmHg. The automatic blood pressure monitor had one reading failure and the measured systolic pressure deviation was 21 mmHg. The measurement time showed that the manual blood pressure monitor was 101 seconds faster than the automatic blood pressure monitor. As a result, in a moving ambulance during an emergency, the manual blood pressure monitor showed high reliability because the blood pressure measurement was constant and the measurement time was short.

Convergence study on the intravenous access of paramedics in ambulances (구급차 내에서 수행한 구급대원의 정맥로 확보에 관한 융합연구)

  • Kim, Jin-Hyeon;Shim, Gyu-Sik
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.177-182
    • /
    • 2017
  • The purpose of the study is to investigate the intravenous access of paramedics in ambulance. The study consisted of confidence change in pre and post intravenous access by driving condition and speed of the vehicle. The research subjects were 30 119 paramedics (20 level 1 emergency medical technicians, 10 nurses), and 6 ambulance driving conditions were established in order to measure the number of attempts at intravenous access. The data was collected for 9 days from May 18 through May 27, 2017. The results show no disparities in number of attempts in terms of stop conditions and flat section driving conditions(p=.161) although there were significant disparities in unpaved road(p=.003), speed bump(p=.005), curve(p=.022), and slope(p=.003) section driving conditions. Confidence appeared to significantly rise(p=.000) after the experiment. In conclusion, it is recommended that swift intravenous access inside an ambulance while driving is attempted when the vehicle has come to a stop or a flat section and paramedics should maintain their confidence in intravenous access through continued training.

Dipole-Dipole Resistivity Survey on the Side of Han River near Nanjido Landfill (난지도에 인접한 한강변에서의 쌍극자-쌍극자 전기탐사)

  • Lee, Kiehwa;Kwon, Byung-Doo;Oh, Seok-Hoon;Kim, Cha-Seop
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.335-343
    • /
    • 1996
  • The dipole-dipol electrical resistivity survey was conducted to investigate the probable contamination of the Han river by leachate from the near-by Nanjido Landfill. The survey line of 3 km was set along the unpaved road toward the Han river. For the convenience of the field work, the survey line was divided into four segments. The complete two-dimensional resistivity section was constructed by connecting the inversion result of each segment. Gravity survey was also carried out along the profile parallel to the resistivity line. Near surface resistivity generally appeared to be of very low value in most part of the survey area and the boundary between the alluvium layer and underlying basement rocks is well discriminated on the resistivity section. These results agree well with those of the preceding Schlumberger depth sounding made at adjacent area by Lee and fun (1995). The variation of thickness of the alluvium layer delineated by gravity anomaly profile also correlates well with the result of the resistivity survey on the qualitative basis. The problem of contamination by leachate from the Nanjido Landfill, where various waste materials have been dumped without any proper treatment facilities, has been remains unsolved yet. Therefore, we present the most probable passages of leachate flow based on the survey results and have briefly discussed about measure for contamination control. Considering the thickness of alluvium and the possible existence of fractured zone, the middle point between 1st and 2nd landfill and the midst of 1st landfill are the most hazardous regions to make leachates flow into the Han river. Since large amounts of leachates are observed from the test wells located on the lines extending from the border between the 1st and 2nd landfill and the middle of the lst landfill, contamination protection barriers are strongly recommended near these regions.

  • PDF

Application of Chemical Dust Suppressants for Control of Fugitive Dust in Ash pond of Thermal Power Plant (화력발전소의 회처리장 내 비산먼지 저감을 위한 화학적 먼지억제제 적용 연구)

  • Choi, Yu-Lim;Choi, Jong-Soo;Yang, Jae-Kyu;Park, Sun-Hwan;Joo, Hyun Soo;Chang, Yoon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.6
    • /
    • pp.82-89
    • /
    • 2018
  • The objective of this study is to evaluate efficiencies of chemical suppressants for control of fugitive dust in ash pond of thermal power plant. In this study, $MgCl_2$, PAM (polyacrylamide), and PVA (poly vinyl alcohol) that are generally applied to suppression of fugitive dust generated from unpaved road, coal mining, storage piles and etc, were employed as chemical dust suppressants. The coal ash (coal combustion residuals) were sampled from the ash pond of Yeongheung power division in Incheon, South Korea. The characterization of the sample including particle size distribution, pH, $pH_{PZC}$ and pore volume as well as XRF analysis were carried out. The suppressant treated-samples were investigated with the wind tunnel experiments to estimate and compare the effect of suppressants on stabilization of the surface of coal ash samples. According to the results, the stability of suppressant-treated samples were significantly improved compared to water-treated samples. Among the three kinds of suppressants, PAM and PVA showed higher efficiencies and cost saving than $MgCl_2$.

Measurement and Analysis of Physical Environmental Load during Handling and Distribution of Domestic Fruits -Focused on Seongju Korean Melon

  • Jongmin Park;Donghyun Kim;Wontae Seo;Hyunmo Jung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.2
    • /
    • pp.129-138
    • /
    • 2023
  • The proportion of agricultural products handled through the Agricultural Products Processing Center (APC) is also steadily increasing every year, and in the case of Seongju Korean melon, a total of 10 APCs of Nonghyup and farming association corporations are in operation, and the distribution ratio is about 60% based on total production. In this study, Seongju Korean melon was selected as a target to analyze the environment load during carrying (production farm ~ APC) in the production area and the transport environment load during distribution of domestic fruits, and to analyze the environmental load for handling at APC. The vertical average vibration intensity (overall Grms of 1~250 Hz) of truck transport measured at three transport routes from Seongju Korean melon producer ~ APC, Seongju ~ Seoul and Seongju ~ Jeju was about three times larger than that in the lateral direction and 4.5 times larger than that in the longitudinal direction, respectively. The frequency of occurrence of high-amplitude events (G) in the vertical direction compared to the measuring time was deeply related to pavement conditions in the order of unpaved farm-roads, concretepaved farm-roads, and asphalt-paved main-roads, but overall Grms for the entire frequency band is believed to have a greater impact on vehicle traveling speed than road conditions. On the other hand, the difference in the size and direction of the vibration intensity measured by the forklift truck's main-body and the attachment (fork carrier) during handling at Seongju Korean melon APC was clear, and the vibration intensity of the forklift truck's main-body was largely affected by the stiffness of the fork and the mast according to the handling weight. Based on the field-data of the transport environment during domestic distribution measured through this study, it is believed that it is possible to develop a lab-based simulation protocol for appropriate packaging design.

Studies on the Processing and Management Forms of Filatures (우리나라 제사공장의 공정 관리실태에 관한 조사연구)

  • 송기언;이인전
    • Journal of Sericultural and Entomological Science
    • /
    • no.12
    • /
    • pp.37-45
    • /
    • 1970
  • The processing management forms of our country's filature factories in 1969 are summarized as follows. (1) About 80% of total cocoon collection is made within 5 days involving peak day, and 10% of cocoon collection is finished until 3 days before and after the peak day, (2) About 92% of alive cocoons transported on unpaved road, and about 40% of the cocoons purchased by all factories are loaded on trucks from common selling station which is far beyond 40km, therefore a new packing system of alive cocoons to drop the damage of cocoon qualities, should be taken. (3) 22% of all factories in our. country have only low-temperature cocoon drying machine. Therefore the installment of hot-air cocoon drying machine is required urgently. (4) In view of cocoon qualities in our country, the grouping method of cocoon for reeling. taken by about 50% of the factories at percent, which classify cocoons for reeling as high group (1,2,3,4 grades) and low group(5,6 grades), will have to be replaced by the method tat classify them high group (1,2 grades) middle group (3,4 grades), low group (5,6 grades). (5) The .ratio of cocoon assorting stood about 10% in multi-ends reeling, about 15% in automatic reeling, conclusively, the ratio of cocoon assorting for automatic reeling was higher tan that for multi-ends reeling. One person's ability for a day in cocoon assorting reaches to about 80-100kg. (6) Cocoon cooking condition requires the increase of the cooking time, the pressure and temperature used to be prolonged as much as the qualities of cocoons are material cocoon ior automatic and double cocoon machines are treated uncompletely. (7) Automatic silk reeling is being performed at 1-2$^{\circ}C$ lower in reeling water temperature and operated at about twice velocity. (8) The temperature and humidity of rereeling room stood at 25$^{\circ}C$, 67.2% R.H and 32.3$^{\circ}C$, 51.9% R.H of rereeling machine are showed, Average rereeling velocity is 233m/min and large reefs charged for one person are 7.5 reels and form of skein used in all factories is double skein. (9) About 73% of water sources for filature used under-earth water. About 48% of all filature factories in our country have not yet water purifying equipments. Installation of the equipment for these factories seems to be urgent, (10) Denier .balance, sizing reel, seriplane, are being used in most factories as self-inspection apparatus. (11) More than 90% of the factories use the vacum tank in rereeling process and about 20% of them use it in cocoon cooing process (12) Only 21% of the factories use chemicals in filature process. About all them use "Seracol 100" in cocoon cooking process and "Seracol 500" in rereeling process, (13) Above survey results explain each all factories show large difference in the processing management. Therefore, it is believed that intercommunication through seminar or technical exchange will contribute to the production evaluation of cocoon in our filature industry.

  • PDF