• Title/Summary/Keyword: university laboratory safety

Search Result 1,640, Processing Time 0.028 seconds

Evaluation of Nutrients Removal using Pyrolyzed Oyster Shells (소성온도에 따른 굴 패각의 영양염 제거 성능 평가)

  • Jeong, Ilwon;Woo, Hee-eun;Lee, In-Cheol;Kim, Jinsoo;Kim, Kyunghoi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.906-913
    • /
    • 2019
  • To evaluate the removal performance of PO4-P and NH3-N, laboratory experiments were conducted by filling a container with oyster shells, pyrolyzed at 100℃ (POS100), 600℃ (POS600) and 800℃ (POS800), and passing artificial wastewaters through the container. The pH in the ef luent was found to increase due to CaO eluted from oyster shell. Removal amounts of PO4-P of ~23.1 mg/kg, 16.1 mg/kg, and 15.9 mg/kg were obtained when POS100, POS600, and POS800, respectively, were used; therefore, the highest PO4-P removal amount was obtained when POS100 was used. It is considered that Ca and dolomite in the oyster shells adsorbed and precipitated PO4-P. Removal amounts of NH3-N were of ~3.56 mg/kg, 5.72 mg/kg, and 3.97 mg/kg were obtained when POS100, POS600, and POS800, respectively, were used The low removal rate for NH3-N is probably due to unstable nitrification, use of sealed containers, and the effect of NH3-N being converted to NH4+ upon increasing pH. Based on these results, pyrolyzed oyster shell is expected to promote changes in PO4-P and NH3-N concentrations through chemical reactions. These results can also be used for basic research in the development of wastewater treatment.

Assessment of dust exposure and personal protective equipment among dental technicians (치과기공사의 분진노출 수준 및 개인보호구 착용 실태 - 대구지역을 중심으로 -)

  • Park, Soo-Chul;Jeon, Man-Joong;SaKong, Joon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.93-102
    • /
    • 2011
  • Purpose: The study aimed to evaluate working environment for dental technician by measuring dust level, ventilation conditions and the use of personal protective equipment and to provide basic information required to improve working environment and develop health education programs for dental technician. Methods: A total of 240 dental technician who are registered with the Daegu Association of Dental technician and working at 34 dental laboratories participated in the study. And the dust level was measured at 21 different spots in 16 dental laboratories out of 34. Results: Of 34 dental laboratories, 31 (91.2%) were equipped with a ventilator, but the remaining 3 (8.8%) did not have a ventilator. By the number of ventilator, 1 to 3 ventilators were found in 22 dental laboratories (71.0%), 4 to 6 ventilators were in 7 laboratories (22.5%) and more than 7 ventilators in 2 laboratories(6.5%). According to the frequence of changing filters in dust collector, 20 dental laboratories (58.9%) changed filters every four weeks, 10 laboratories (29.4%) changed them every six weeks and 4 laboratories (11.7%) changed them every eight weeks. Of total respondents, 114 (61.3%) said they wore a mask all the time while working, 56 (29.6%) said they frequently wore a mask, 19 (10.1%) said they did not wear a mask. As for the type of masks, 159 (84.1%) used a disposable mask, 25 (13.2%) used a cotton mask and 5 (2.7%) used an anti-dust mask. For dust sat on their outfits while working, 102 (54.0%) shook their uniforms inside workplace to keep dust off the uniforms, 64 (33.9%) did not anything until they wash their uniforms and 23 (12.1%) shook their uniforms outside workplace to keep dust off the uniforms. Of total respondents, 182 (96.3%) had a particle in their eyes while carrying out grinding work. Based on the measurement of floating dust at workplace, 3 dental laboratories showed dust concentration exceeding the minimum level of 10 mg/$m^3$ allowed under the permit for environment. Of those, 1 laboratory had the dust concentration that was more than 1.5 times higher than the minimum level. Dust concentration was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Dust comprised of nickel (more than 70%), chrome (9%) and others. The mean chrome concentration was more than twice higher than the minimum permissible level of 0.5 mg/$m^3$. There were two laboratories that showed chrome concentration exceeding the level of 0.4 mg/$m^3$. Like dust concentration, chrome level was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. There were six laboratories that had nickel concentration exceeding the minimum permissible level of 1 mg/$m^3$. Of those, one laboratory had nickel concentration that was more than three times higher than the minimum permissible level. Nickel concentration was also higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Conclusion: It is not likely that heavy metal concentrations found in the study constitute respiratory dust. It is however necessary for health of dental technician to apply the Industrial Safety and Healthy Law to dental laboratories and make recommendations for the use of personal protective equipment, installation of a proper number of ventilators, more frequent change of filters in dust collector and improved ventilation for polishing work. At the same time, dental technician need education on how to use personal protective equipment and how to efficiently remove dust from their uniforms.

A Study on Bio-Monitoring Systems using Shell Valve Movements of Pacific Oysters (Crassostrea gigas) in response to Abnormal High Water Temperature (이상 고수온에 반응하는 이매패류 참굴(Crassostrea gigas)의 패각운동을 활용한 생물모니터링시스템 연구)

  • Moon, Suyeon;Kim, Dae Hyun;Yoon, Yang Ho;Oh, Seok Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.91-97
    • /
    • 2017
  • This study contains research on a bio-monitoring system (BMS) capable of detecting abnormal high water temperatures, the shell valve movements (SVMs) of Pacific oysters (Crassostrea gigas), which were measured at four different temperature (5, 10, 20 and $30^{\circ}C$) under laboratory conditions. All the Pacific oysters were kept under fasting conditions for 3 days to prevent the influence of food and excretions before the onset of the experiments. SVMs did not detect at $5^{\circ}C$. However, SVMs increased with an increase in temperature (at $10^{\circ}C$ : $6.31{\pm}2.18times/hr$ and at $20^{\circ}C$: $22.0{\pm}10.0times/hr$). At $30^{\circ}C$, SVMs were divided into two groups: those with no SVMs as at $5^{\circ}C$ and those with SVMs similar to conditions at $20^{\circ}C$($23.9{\pm}9.35times/hr$). This indicates oyster shells maintain a closed condition due to a decrease in metabolism at $30^{\circ}C$, although some Pacific oysters had active SVMs due to an increase in metabolism. If a BMS using the SVM status of Pacific oysters was installed to monitor abnormal high water around oyster farms, early warning levels and serious alerts might be made available more rapidly for SVMs of more than ca. 30 times/hr and closing conditions in a matter of hours, respectively. Therefore, a BMS using the SVMs of Pacific oysters might be an effective early warning system for abnormal high water temperatures.

Application of Prefabricated Retaining Walls with Steel Lagging (강재 요소를 적용한 조립식 흙막이 벽체에 관한 연구)

  • Hong, Jong woo;Choi, Jae Soon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.1277-1285
    • /
    • 2015
  • It has been known that the conventional retaining wall system with timber lagging and H pile has several problems such as the irregular gap between H-piles, cutting or adding to standard timber, back fill over first step excavation, and especially break-down accident at the disjoint of wall system. In the practical excavation, these problems may lead to worker's accident and the inefficiency of construction economy. To solve the above problems, a new method using prefabricated retaining wall was proposed and verified. The characteristics of the new method is to replace timber wall as free-sliding steel-lagging and connector. To check its verification and application, laboratory tests such as bending strength, tensile strength, and fatigue strength were carried out. Also, a pilot test in the field and numerical simulations under various ground conditions were performed. From the researches, it is found that the prefabricated retaining wall plate can be superior to the conventional timber lagging plate in the strength. It is also found that the proposed methods can be effective in the reuse of retaining wall plate and safe in the disjoint of wall system. Finally, it is desired that the proposed method will be effective in the reduction of the imported timbers and helpful in the safety of retaining wall construction.

An Experimental Study on the Optimum Mix Design and Site Application Case of Soil Mixing Wall for Trench Stability (구벽안정성을 위한 SMW 최적배합비 및 현장적용 사례에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.419-426
    • /
    • 2015
  • The purpose of this study is to investigate experimentally the optimum mix design and site application case of soil mixing wall (SMW) method which is cost-effective technique for construction of walls for cutoff wall and excavation support as well as for ground improvement before constructing LNG storage tank typed under-ground. Considering native soil condition in site, main materials are selected ordinary portland cement, bentonite as a binder slurry and also it is applied $1,833kg/m^3$ as an unit volume weight of native soil, Variations for soil mixing wall are as followings ; (1) water-cement ratio 4cases (2) mixing velocity (rpm) 3levels (3) bleeding capacity and ratio, compressive strength in laboratory and site application test. As test results, bleeding capacity and ratio are decreased in case of decreasing water-cement ratio and increasing mixing velocity. Required compressive strength (1.5 MPa) considering safety factors in site is satisfied with the range of water-cement ratio 150% below, and test results of core strength are higher than those of specimen strength in the range of 8~23% by actual application of element members including outside and inside in site construction work. Therefore, optimum mix design of soil mixing wall is proposed in the range of unit cement $280kg/m^3$, unit bentonite $10kg/m^3$, water-cement ratio 150% and mixing velocity 90rpm and test results of site application case are satisfied with the required properties.

A Study on Optical Properties of Red Tide Algal Species (적조 원격탐사 기술 개발을 위한 적조생물의 광특성 연구)

  • Lee, Nu-Ri;Moon, Jeong-Eon;Ahn, Yu-Hwan;Yang, Chan-Su;Yoon, Hong-Joo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.187-191
    • /
    • 2006
  • This research is about the optical characteristics of algae which is collected from Nam-Hae for basic research of red tide remote sensing technique development 21 kinds of red tide organisms were cultivated to investigate optical characteristics of them in the level of laboratory, and chlorophyll specific absorption coefficient $(a^*)$ and backscattering coefficient $(b_b^*)$ are estimated by using spectrophotometer. Absorption spectrums according to species appeared to range from 0.005 to 0.06 $(m^2/mg)$, and the shapes of spectrums were also different. The range of $b_b^*$ appeared to be $10^{-2}\sim10^{-4}m^2/mg$, which had about 100 times differences between species, and the shape of spectrum have significant difference between species. These results will input as an ocean color model input parameter from ocean color.

  • PDF

Dissipation Pattern of Fungicides Boscalid and Pyraclostrobin in Jujube (대추 중 살균제 boscalid와 pyraclostrobin의 잔류 소실 특성)

  • Jo, Hyeong-Wook;Sohn, Sang-Hyun;Kim, Kyoung-Jin;Hwang, Gi-Jun;Jo, Beom-Haeng;Gil, Seok-Ju;Kwon, Chan-Hyeok;Moon, Joon-Kwan
    • The Korean Journal of Pesticide Science
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 2017
  • Dissipation pattern and biological half-lives of fungicides boscalid and pyraclostrobin were calculated on jujube. The pesticides were sprayed on jujube in two different field at the standard rate, respectively. The raw agricultural commodities were harvested at 0 (2 hr), 1, 3, 5, 7, 10 and 14 days after treatment, and analyzed by HPLC/DAD. The method limit of quantification (MLOQ) was $0.02mg\;kg^{-1}$ for boscalid and pyraclostrobin. The recovery ranged 101.8~109.3% with below 5% of CV (Coefficient of variation) for boscalid and 104.2~115.4% with below 5% of CV for pyraclostrobin. An average initial deposit at field 1 and field 2 samples were observed 0.40 and $0.48mg\;kg^{-1}$ for boscalid and, 0.76 and $0.57mg\;kg^{-1}$ for pyraclostrobin, respectively. The biological half-lives of field 1 and field 2 were 11.0 and 13.2 day for boscalid, and 6.1 and 12.7 days for pyraclostrobin.

Studies on the Cultural and Serological Tests of Mycoplasma Pulmonis in Laboratory Animal. (실험동물에 Mycoplasma Pulmonis의 배양 및 혈청학적 시험)

  • Kim Jae Yeon;Lee Yong Hee
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.69-79
    • /
    • 1986
  • This studies were carried out to investigate the high infection sites from various specimens, cultural isolation on the susceptible media and specific antibody titres of M. pulmonis in experimental 310 mice and 330 rats obtained from two breeding facilities. Efficiency of complement faxation test (CF test) for detection of M. pulmonis antibody in mice and rats were compared directly with the diagnostic cultural isolation method. 1. Isolation rates of M. pulmonis among infection sites were about 30% from the oral cavities and $40\%$ from the middle ear of mice. The rates were $100\%$from the nasal cavaties and $90\%$ from the oral cavities of rats. 2. The infection rates were $12\%$ to A group and $16\%$ to B group of mice. The rates in the rats were $55\%$ to A group and $70\%$ to B group. 3. The M. pulmonis antibody titres by CF test were $73\%$ of total 100 mice in serum dilution below 1:5 (< 1:5), and $24\%$ of total samples in antibody titres above 1:5 (> 1:5), but 3 samples were not showed anticomplementary activities. The antibody titres in rats were $35\%$ of 120 rats in below 1:5 (< 1:5), and $61\%$ of total samples in above 1:5 (> 1:5), but the remained were not showed anticomplementary activities.

  • PDF

Experimental analysis of the sedimentation processes in the movable weir by changing the channel slope considering weir operation (가동보 운영 및 하상경사 변화에 의한 보 상류 퇴사과정의 실험적 분석)

  • Lee, Kyung Su;Jang, Chang-Lae
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.8
    • /
    • pp.729-737
    • /
    • 2018
  • This study investigates the sediment processes the Improved-pneumatic-movable weir through laboratory experiments considering changing channel slopes. Experimental results show that the delta migrates towards the weir and the delta height increases as time passes. Moreover, as the delta approaches the weir, the delta migration speed decreases. As the dimensionless delta location increases, the effective height of dimensionless delta and the dimensionless reservoir capacity increases. Therefore, under the same slope conditions, the sediment deposition volume of the delta is small as the channel slope is mild. This means that the channel slope affects the development of the delta in the upstream of the Improved-pneumatic-movable weir. At the beginning of the experiment, the foreset slope is mild. However, the foreset slope of the delta increases with water depth as the delta migrates downstream. Moreover, as the slope is mild, the ratio of delta front length to delta height is close to 1, and the dimensionless delta height and the dimensionless delta migration speed decrease. As the delta height increases, the water depth, the velocity approaching to the weir and the delta migration speed decrease.

Numerical Investigation of the Density and Inlet Velocity Effects on Fiber Orientation Inside Fresh SFRSCC (SFRSCC의 섬유 방향성에 미치는 입구 속도와 점성의 영향성에 대한 수치해석)

  • Azad, Ali;Lee, Jong-Jae;Lee, Jong-Han;Lee, Gun-Jun;An, Yun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.16-20
    • /
    • 2018
  • Steel Fiber reinforced self-compacting concrete (SFRSCC) has been widely used in a number of structures, such as ordinary civil infrastructures, sky scrapers, nuclear power plants, hospitals, dams, channels and etc. Thanks to its short and discrete reinforcing fibers, its performance, including tensile strength, ductility, toughness and flexural strength gets much better in comparison with ordinary self-compacting concrete (SCC) without any reinforcing fibers. Despite all these aforementioned advantages of SFRSCC, its performance highly depends on fiber's orientation. In case of short discrete fibers, the orientation of fibers is completely random and cannot be controlled during pumping process. If fibers distribution inside hardened state concrete are randomly distributed, it leads to less resistance potential of concrete element, especially in terms of flexural and tensile strength. The maximum expected strength may not be achieved. Therefore, fiber alignment has been considered as one of the important factors in SFRSCC. To address this issue, this study investigates the effects of concrete matrix's density and inlet velocity on fiber alignment during the pumping process using a finite element method.