• Title/Summary/Keyword: unit-regular

Search Result 312, Processing Time 0.026 seconds

Trend Changes of Spatial Configuration in Housing Units of Korean Apartments in the 2000s (2000년대 한국 아파트 단위세대의 공간구성 동향 변화)

  • Park, Joon Young;Jeong, Sang Kyu;Cheong, So Yi;Park, Woo Jang
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.21-27
    • /
    • 2012
  • This study aims at finding the trend changes of spatial configuration in housing units of Korean apartments in the 2000s. Among the housing units in the apartments built by large construction companies, we have selected ones with small and regular sizes, $59m^2$ and $84m^2$ respectively, and investigated the number of bays, the location of wet zone and the spatial flexibility in the housing units selected for analysis. In conclusion, the number of bays in the housing unit has gradually increased, after allowing for the structural change of the balcony in the legal. It is estimated that the trend has came from the intent to increase the numbers of the externally exposed surfaces of the balcony, ensure a good view, lighting, ventilation and spatial flexibility. The location of wet zone, water-needed space such as a bathroom or a kitchen, has changed in the direction to facilitate the expansion and modification of space. Variable range of space has gradually expanded by using the balcony and wet zone as much as possible. In order to configure more effectively spaces in housing environments, the future study should be implemented to develop tools for realizing sustainable housing environment at the levels of not only the housing unit. but also the entire building, housing site, and city.

Analysis of concrete characteristic depending on chemical admixtures changing component content ratio (화학혼화제의 성분함유율 변화에 따른 콘크리트의 특성분석)

  • Ryu, Hyun-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.2
    • /
    • pp.85-91
    • /
    • 2009
  • W/C and unit volume, which significantly affect quality of concrete related to strength and durability, are regulated at below $185kg/m^3$ for regular concrete generally used in standard specification for constructions. The aim of this research is to develop chemical admixture and find out its potential use by identifying characteristics of admixtures added to soft concrete and hardening concrete, of which content ratio of component for each type of admixtures is subject to change in accordance with unit volume within KS' allowable range. Sodium gluconate, polyoxyethylene nonylphenyl ether, poly carboxylic copolymer in slump, which is characteristic of soft concrete, are deemed highly sensitive while there is no air entrainment except for $10\sim70%$ in WE, WR component content ratio and NP. In hardening concrete, strength in general showed higher action in compressive strength and tensile strength than in plain strength. Use of proper AE agent and AE water reducing agent at the same time is deemed to be used as chemical admixtures capable of manufacturing high-quality, high-quantity concrete.

Novel Maritime Wireless Communication based on Mobile Technology for the Safety of Navigation: LTE-Maritime focusing on the Cell Planning and its Verification

  • Shim, Woo-Seong;Kim, Bu-Young;Park, Chan-Yong;Lee, Byeong-Hyeok
    • Journal of Navigation and Port Research
    • /
    • v.45 no.5
    • /
    • pp.231-237
    • /
    • 2021
  • Enhancing the performance of maritime wireless communication has been highlighted by the issue of cell planning in the sea area because of lack of an appropriate Propagation Loss Model (PLM). To resolve the cell planning issue in vast sea areas, it was essential to develop the (PLM) matching the intended sea area. However, there were considerable gaps between the prediction of legacy PLMs and field measurement in propagation loss and there was a need to develop the adjusted PLM (A-PLM). Therefore, cell planning was performed on this adjusted model, including modification of the base station's location, altitude, and antenna azimuth to meet the quality objectives. Furthermore, in order to verify the availability of the cell planning, Communication Service Quality Monitoring System (CS-QMS) was developed in the LTE-Maritime project to collect LTE signal quality information from the onboard equipment at regular intervals and to ensure that the service quality was high enough to satisfy the goals in each designated grid. As a result of verification, the success rate of RSRP was 95.7% for the intensive management zone (IMZ) and 96.4% for the interested zone (IZ), respectively.

Reasons, Incidences, and Influencing Factors of Work Interruptions in Intensive Care Unit Nurses (중환자실 간호사에게 발생하는 업무 흐름 중단 이유와 발생빈도 및 영향요인)

  • You, Jung Eun;Lee, Eun Nam
    • Journal of muscle and joint health
    • /
    • v.27 no.3
    • /
    • pp.247-254
    • /
    • 2020
  • Purpose: This was a descriptive observational study examining the reasons for, frequency of, and factors affecting work interruption among intensive care unit (ICU) nurses. Methods: Convenience sampling was used to recruit 46 regular nurses who had been working in an ICU at D tertiary hospital in B metropolitan city for at least six months. To measure the degree of work interruption, this study revised a tool used by Brixey et al. (2007) for analyzing the type of work interruption. Results: A total of 1,787 work interruptions occurred during 368 hours of observation, i.e., at an average of 4.85 times per hour. Communication-related factors caused work interruption most frequently, followed by environmental, work-related, and personal factors. As for the work-related characteristics of nurses, participants experienced work interruption more frequently while working on weekdays, when the medical staff were stationed, than on weekends. Conclusion: ICU nurses experienced work interruption frequently. With the health care system expected to become more complicated in the future, efforts should be made to reduce unnecessary work interruptions to improve the operation efficiency of ICUs.

Differences in the perceptions of partnership between nurses and mothers of children in a pediatric intensive care unit in South Korea: a qualitative study

  • Park, Bobae;Oh, Won-Oak
    • Child Health Nursing Research
    • /
    • v.28 no.3
    • /
    • pp.197-207
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate how pediatric intensive care unit (PICU) nurses and the mothers of hospitalized children perceived their partnership and identify the detailed differences in the common domains of partnership between them. Methods: A qualitative descriptive design with semi-structured and open-ended interviews was used. Interviews with mothers of hospitalized children and nurses in the PICU were conducted at a national university hospital in South Korea. Results: Five integrated categories were identified concerning nurses' and mothers' perceptions of partnership. Five common domains were derived by merging the partnership categories perceived by each PICU mother and nurse: expectation of trust, sharing and communication, participation in care, equality in the relationship, and coordination of opinion However, there were significant differences in the composition of the categories of these common domains. Conclusion: These results may facilitate more effective partnerships between parents and PICU nurses. Efforts should be taken to promote the formation of trust between nurses and parents and create an environment that is conductive to regular open communication in particular, steps should be taken to reduce gaps in awareness concerning this partnership and information sharing, nursing methods, and decision-making.

RFID Based Indoor Localization and Effective Tag Arrangement Method (RFID를 기반으로 한 실내 위치 파악 및 효율적 Tag 배치)

  • Yoon, Chang-Sun;Yoon, Dong-Min;Kwon, Young-Chan;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8760-8766
    • /
    • 2015
  • In this paper a technology which gives directions to people and also localization of the robotic vacuum cleaners inside some spacious buildings is developed. For this purpose, it is confirmed that which pattern has a small error in dealing with the indoor localization with various RFID tag arrangements attached on the ground. This experiment was conducted by using MT92(900MHz range Antenna) and ALR 9900+(Reader). As a result, the square arrangement has the least error, 21.19cm, among other patterns which are diamond, rectangle and regular hexagon. However, it is necessary to consider the number of tags in the unit area, from this point of view the regular hexagon arrangement is the most efficient arrangement among other patterns because it needs only 6 tags in the unit area.

Mining Frequent Itemsets using Time Unit Grouping (시간 단위 그룹핑을 이용한 빈발 아이템셋 마이닝)

  • Hwang, Jeong Hee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.647-653
    • /
    • 2022
  • Data mining is a technique that explores knowledge such as relationships and patterns between data by exploring and analyzing data. Data that occurs in the real world includes a temporal attribute. Temporal data mining research to find useful knowledge from data with temporal properties can be effectively utilized for predictive judgment that can predict the future. In this paper, we propose an algorithm using time-unit grouping to classify the database into regular time period units and discover frequent pattern itemsets in time units. The proposed algorithm organizes the transaction and items included in the time unit into a matrix, and discovers frequent items in the time unit through grouping. In the experimental results for the performance evaluation, it was found that the execution time was 1.2 times that of the existing algorithm, but more than twice the frequent pattern itemsets were discovered.

Reflection of Plane Shock Wave over Concave and Convex Walls (오목, 볼록면에서 평면충격파의 반사)

  • JEON, Heung-Kyun;KWON, Jin-Kyung;KWON, Soon-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1473-1480
    • /
    • 1999
  • In the case of Impingement of plane moving shock wave over concave or convex double wedges (pseudo-stationary flow) and cylindrical walls (truly non-stationary flow), it Is expected that there are transitions from regular reflection to Mach reflection or vice versa In shock wave reflections. In these connections, it is necessary to verify the various of reflection process and transition angle for the reflection problems In double wedges, and to verify the transition angle, effects of curvature radius and initial wall angle on it for the reflection problems In cylindrical walls. Especially, we focused our attention to confirm the existence of hysteresis phenomenon induced by the different transition processes, and Neumann paradox, which is a small discrepancy between theoretical and experimental transition angles. Experiments were carried out by using the shock tube of $6{\times}6cm^2$, and high speed photographic technique consisted of delay unit, triggering system, light source of Xe lamp and so on was used for flow visualization.

A Comparative Study on the Laws regulating Multi-family Housing Amenities for Single or 2 resident Household in Korea, Japan and UK (1-2인 가구를 위한 공동주택의 공용공간 규정에 관한 한국·일본·영국의 건축법규 비교 연구)

  • Lee, Eunjoo;Lee, Sang Ho
    • Journal of the Korean housing association
    • /
    • v.26 no.5
    • /
    • pp.105-112
    • /
    • 2015
  • This research was aimed at finding clues of improving residential quality of the Urbanistic Housing which was introduced for the small household of 1-2 residents. It was the laws on communal amenity in multi-family housing that this research concentrated on. Looking into the multi-family housing standards for small household of Korea, Japan and UK, Japanese One-room housing Ordinance of Tokyo-do laid stress on avoiding conflict among residents and getting people mixed together. And UK's concentrated on every individual rooms inside HMO and suggested certain level of qualified life through the careful standards. On the other hand, Korea's just suggested minimum housing with unit households and nearly no amenity except for parking lots. There should be more than a physical space with some area which satisfies basic physiological needs in a residence. To become a quality residence filled with relationship, it is necessary that Urbanistic Housing are also required to provide communal amenities, not as much as regular housing for regular household but much more than Quasi-housing, the minimum residence. And it should be ensured by the legal system to make it more effective.

Efficient Prediction in the Semi-parametric Non-linear Mixed effect Model

  • So, Beong-Soo
    • Journal of the Korean Statistical Society
    • /
    • v.28 no.2
    • /
    • pp.225-234
    • /
    • 1999
  • We consider the following semi-parametric non-linear mixed effect regression model : y\ulcorner=f($\chi$\ulcorner;$\beta$)+$\sigma$$\mu$($\chi$\ulcorner)+$\sigma$$\varepsilon$\ulcorner,i=1,…,n,y*=f($\chi$;$\beta$)+$\sigma$$\mu$($\chi$) where y'=(y\ulcorner,…,y\ulcorner) is a vector of n observations, y* is an unobserved new random variable of interest, f($\chi$;$\beta$) represents fixed effect of known functional form containing unknown parameter vector $\beta$\ulcorner=($\beta$$_1$,…,$\beta$\ulcorner), $\mu$($\chi$) is a random function of mean zero and the known covariance function r(.,.), $\varepsilon$'=($\varepsilon$$_1$,…,$\varepsilon$\ulcorner) is the set of uncorrelated measurement errors with zero mean and unit variance and $\sigma$ is an unknown dispersion(scale) parameter. On the basis of finite-sample, small-dispersion asymptotic framework, we derive an absolute lower bound for the asymptotic mean squared errors of prediction(AMSEP) of the regular-consistent non-linear predictors of the new random variable of interest y*. Then we construct an optimal predictor of y* which attains the lower bound irrespective of types of distributions of random effect $\mu$(.) and measurement errors $\varepsilon$.

  • PDF