• Title/Summary/Keyword: unit water test

Search Result 396, Processing Time 0.031 seconds

Development and Performance of Self-Propelled Vehicles for Repairing Concrete Sewage Pipes (콘크리트 하수관로 결함부 보수를 위한 자주차 개발 및 성능평가)

  • Park, Ji-Hun;Jung, Hoe-Won;Park, Hee-Woong;Yang, In-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.3
    • /
    • pp.372-378
    • /
    • 2020
  • In this study, an experiment was conducted on the development and performance of self-propelled vehicles to repair defects in concrete sewage pipes. The self-propelled vehicle for a non-excavation repair for the sewage pipe defects was developed in consideration of the performance of the driving system, the feasibility of the repair unit, and the transportation of repair materials. In order to evaluate the performance of the developed self-propelled vehicle, a repair test was performed by simulating a defect at a connection between the main pipe and extruded one. The main sewage pipe was meade of concrete and its diameter was 500mm. Thereafter, watertightness performance was evaluated on the leakage at the repaired part. For watertightness performance, both ends of concrete sewage pipe and connected one was inserted by plugs, and then water was injected. The amount of leakage water measurement was 0.07L/㎡, indicating a value less than 0.2L/㎡ of the allowable leakage amount. Therefore, test results indicated that the self-propelled vehicle developed in this study exhibited excellent maintenance performance for repairing the sewage pipes.

Effect of Low-Plastic Fine Content on the Engineering Properties of Kaolinite-Sand Mixture (저소성 세립분 함량이 카올리나이트-모래 혼합토의 공학적 특성에 미치는 영향)

  • Kaothon, Panyabot;Lee, Su-Hyung;Choi, Yeong-Tae;Yune, Chan-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.7
    • /
    • pp.35-42
    • /
    • 2021
  • An experimental study was carried out on kaolinite-sand mixtures with various proportions of kaolinite content. To investigate physical behaviour of mixtures, index properties and compaction test results were analysed in various aspects. Moreover, to clearly see the interaction between kaolinite and sand particles, the observational analysis through microscopic image analysis device was conducted. The test results showed that an increase in the amount of kaolinite could create a strong bonding structure which resulted in higher specific surface available for activities of kaolinite particles. Also, an increase in the amount of the kaolinite resulted in an increase in the percentage of water sorption. Then it could accelerate the occupation rate of water which tended to take up the space that would have been occupied by solid particles, and accordingly, resulted in the decreased maximum dry unit weight and increased initial void ratio. Based on the microscopic image analysis, the samples were individually classified into three types of mixture such as sand dominant, intermediate fine content, and fine dominant. In addition, the fine and coarse grains seem to interact well in the mixtures with the fine content ranging from 25 to 40%.

Estimation of Appropriate Infiltration Rate and the Effects of the Flowerbed Type Infiltration System (화단형 침투시설의 단위설계침투량 산정 및 효과분석)

  • Han, Young-Hae;Lee, Tae-Goo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.140-147
    • /
    • 2012
  • This study developed a flowerbed type infiltration system that could control the amount of runoff discharge under a certain level estimated its proper design infiltration rate, and analyzed the effects of its implementation. Analyzing the performance of infiltration system is the one of the essential processes that should be under review to predict its effects after implementation when a rainwater infiltration system is included in a district-based plan. To estimate the unit design infiltration rate of this system, the runoff decrease effect was analyzed by varying the unit infiltration rate of the system applied to the parking lot adjacent to the Korea Institute of Construction Technology laboratory building by using a water balance analysis program. After varying the unit design infiltration to $0.1{\sim}3m^3/m^2.day$ to analyze the variation in the rate of runoff, 80% of the runoff was infiltrated at $1.0m^3/m^2.day$, and the unit infiltration design rate at the time was 0.0416(m3/m2.hr). It was also found that the unit design infiltration rate obtained from a field infiltration test of the developed system was about $0.045m^3/hr$. Based on this study, it was possible that infiltration rate is estimated to consider the economic scale and environmental effect. It is significant to apply the spatial plan of rainwater infiltration system as green infrastructure.

A Study on Shear Behavior of High Strength Reinforced Concrete Beams (고강도 철근콘크리트 보의 전단거동에 관한 연구)

  • Kwak, Kae-Hwan;Park, Jong-Gun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.5
    • /
    • pp.68-79
    • /
    • 1998
  • In the years, the concern about high-strength concrete which is new material has been heightened as a result of active research and development. Recently, as the building structure has been being bigger, higher, longer and more specialized, the demand of material with high-strength concrete for building has been increasing. The demand of high -strength concrete is expected to increase with expansion of usage about the complex concrete structures such as bridge structure as well as nuclear plants, underground structures, hydraulic structures and arctic area sturctures. In this research, silica-fume was used as an admixture in order to get a high-strength concrete. Water/binder ration was limited no more than 18 percent and the amount of unit cement was increased. In this study, a number of trial in concrete mix was carried out to get optimal mix design, and the target slump with $10{\pm}2cm$ was set for in-situ construction. High-strength concrete with cylinder strength of 1,200kgf/$cm^2$ in the 28-days was produced and tested. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns, fracture modes. The load versus strain and load versus deflection relations were obtained form the static test. The test results were compared with the shear strengths predicted by the equations of ACI code 318-89 and orther researchers. Based on the test results, shear strength equation of reinforced concrete beam using high strength concrete was proposed. Form an evaluation of the results of this experimental investigation, it was concluded that shear strength after diagonal tention cracking diminished with the increase in compressive strength for beams.

  • PDF

Model Test for Towing Stability and Seakeeping of a Multi-Purpose Mobile Base (해상풍력 일괄설치시스템 예인 안정성 및 내항성능 평가를 위한 모형시험)

  • Cho, Dong-Ho;Lee, Jun-Shin;Ryu, Moo-Sung;Jung, Min-Uk;Lee, Ho-Yeop;Han, Kwan-Woo;Kim, Seung-Han
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.163-171
    • /
    • 2020
  • A model test for assessment of towing stability and seakeeping of a multi-purpose mobile base (MMB) was performed in calm water and wave conditions. Scale ratio of the MMB was 1/48. Tension of the towing line was measured during tests to estimate effective power to tow the full scale MMB. The tests were repeated with towing speed. In addition, an inertial measurement unit was used to measure six DOF motion of the model. Seakeeping performance was assessed through the captive model test.

Effect of Air Void System of High Strength Concrete on Freezing and Thawing Resistance (고강도콘크리트의 동결융해저항에 미치는 기포조직의 영향)

  • 김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.1
    • /
    • pp.89-96
    • /
    • 1992
  • It is generally known that the frost-resistance of concrete is much affected by the air content in concrete and by the air void system or air distribution. And also the frost-resistance is believed to vary with the stre¬ngth of concrete. This article is prepared to describe, based on experiment, the effect of the air content and the air void system, particularly the effect of the spacing factor, on the freeze-thaw resistance of the high strength conc¬rete. For this purpose, I first worked on Non-AE concrete to make its compressive strength set about 400 to 500 kg/em'. However, the freeze-thaw test on the Non-AE concrete resulted in low durability factor, I.e., 10-2~0%. Thus to enhance the durability, another supplementary step was needed. I used AE admixture. which enhanced durability by changing the air content from 2% to 12%. The frost-thaw test was then performed 500 cycles on the 20 kind of concrete mixtures which differ in unit cement content and in water-cement ratio. Keywords : frost -resistance, air content, air void system, air distribution, spacing factor, freeze-thaw test, dur ability factor. capillary cavity, Linear Traverse Method.

A study on the capability of edge shape milling tool with the operatio parameters of equipment (장비운영요소변화에 따른 석재측면 성형공구의 성능시험 연구)

  • 선우춘
    • Tunnel and Underground Space
    • /
    • v.8 no.4
    • /
    • pp.332-341
    • /
    • 1998
  • Conventional polishing of stone panel edges has been done by hand. While this has changed somewhat with the advent of automatic machines, it is still very much a hand finishing technology. For the development of edge shape milling tool, the primary test on characteristics of edge shape milling tool was carried out. This paper presents the results of tests focused upon the milling capability that was varied by the variables of operation parameters. Author tried to confirm the effect of six operation parameters of equipment such as rotation speed, advance speed, applied load, water flow rate and rotational direction. The result from test was described in term of shape milling capability that was defined as cutting volume of rock by unit weight of tool wear. The variance of the results could indicate the optimum level of each operating parameters. The test was also carried out to determine the abrasion resistance varied according to the abrasive flow rate. The abrasion resistance was increased with the abrasive flow rate, but over some rate it was not changed.

  • PDF

Groundwater Investigation in Northwestern Part of Saudi Arabia (Saudi Arabia 북서부의 지하수조사)

  • 한정상;정수웅
    • Water for future
    • /
    • v.8 no.2
    • /
    • pp.30-40
    • /
    • 1975
  • Hydrogeological survey and geophysical prospecting have been carried out in Saudi Arabia for the purpose of finding groundwater in the soil and rock at the request of General trading company in Jeddah, Saudi Arabia. The surveyed area is located on $38^{\circ}-39^{\circ}$ 30' in longitude and $26^{\circ}-26^{\circ}$ 30' in latitude. The topography of this area is dominated by northwest southeast mountain range composed mostly of precambrian rocks and basalt of tertiary period. Geology is mainly composed of greenstone, granite, andesite, diorite rhyolite of pre-cambrian era and sandstone of cambrian period which are underlained by basalt and andesite of tertiary period and alluvium of quaternary unconformably. The instruments used in this investigation are TR-18B2 radioactivity unit which isjapanese patented and A.C. Terrameter, a resistivity meter manufactured by ABEM of Stockholm, Sweden. Radioactivity method has been conducted along the Alula-Khaybar road, totally 164Km by the car-borne. As a result of the above survey 16 places have been selected and these anomalies show 1.2N-1.6N compared to background of each area in intensity with width of 10-50m. Resistivity vertical profiling which made use of Schlumberger configuration method has been made over selected areas by radioactivity method to provide hydrogeological information for a water resources survey. The result of resistivity shows that good aquifers are located in the western part of surveyed area where sedimentary rock is distributed. The strata showing 10-50, ${\Omega}-m$ in resistivity are thought to be waterbearing layer. The variations in aquifer resistivity found, are thought to be due to verying clay content, which could be related to aquifer yield. It has proved impossible to detect small salinity variation in the buried aquifer by geophysics. As a result of resistivity prospecting 10 places are recommended to be drilled at the anomalies as shown attached map. yields from the proposed holes have been estimated approximately from $20m^3$ to $200m^3$ per day. Prior to drilling for groundwater, test boring using ${\c}4"$ should be drilled in order to obtain more reliable hydrogeological information for the construction of perfect wells.ells.

  • PDF

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

The Effects of Taurine and $\beta$-alanine on Blood Glucose and Blood Lipid Concentrations in Insulin-treated Diabetic Rats (실험적 당뇨쥐의 인슐린 치료시 타우린과 베타알라닌이 혈당 및 혈중 지질대사에 미치는 영향)

  • 장경자
    • Korean Journal of Community Nutrition
    • /
    • v.4 no.1
    • /
    • pp.103-110
    • /
    • 1999
  • The purpose of this study was to determine the effects of taurine supplementation and taurine depletion on blood glucose and blood lipid concentrations in insulin-treated diabetic rats. Four groups of Sprague-Dawley male rats were fed the purified diet for 3 weeks ; nontaurine-supplemented diabetic rats(E0), nontaurine-supplemented diabetic rats with insulin treatment(E0+I), 1% taurine-supplemented diabetic rats with insulin treatment(E1+I) and taurine-depleted diabetic rats with insulin treatment(EA+I). Diabetes was induced by streptozotocin injection(50mg/kg B.W.). Isophane insulin was given subcutaneously into the abdominal wall of the diabetic rats(4 unit/rat/day). E1+I were supplemented with 1% taurine in drinking water. To induce taurine depletion, EA+I were treated with 5% $\beta$-alanine in drinking water. E1+I had significantly higher body weight compared to that of E0. The food intakes of E1+I and E0+I were significantly decreased compared to that of E0. There was no sigfniciant difference in food intake between E1+I and E0+I. The water intake of rats was significantly different among the groups ; E0>E0+I>E1+I>EA+I. The urine volume of E0 was significantly increased compared to those of insulin-treated goups. The blood glucose concentration of E0 was significantly increased compared to those of insulin-treated groups. In the oral glucose tolerance test(OGTT), E0+I and E1+I had significantly lower blood blucose concentrations compared to E0 after 30 min. Also EA+I had significantly lower bloodglucose concentrtion compared to E0 and E0+I. The plasma total cholesterol and LDL-cholesterol concentratons of EA+I were significantly incrased compared to those of other groups. Therefore, it may be suggested that tuarine supplementation is useful for insulin-dependent diabetes in order to prevent diabetic complications suchas cardiac vascular diseases.

  • PDF