• Title/Summary/Keyword: unit testing

Search Result 621, Processing Time 0.024 seconds

Isolation and Characterization of a Crude oil-Degrading Strain, Nocardia sp. H 17-1 (원유 분해균주 Nocardis sp. Hl7-1의 분리 및 특성)

  • 이창호;권기석
    • KSBB Journal
    • /
    • v.11 no.6
    • /
    • pp.654-662
    • /
    • 1996
  • Bacterial strains which degrade crude oil were isolated by liquid culture from oil-spilled soil, and four isolates were selected among them. The strain Hl7-1 was finally selected after testing emulsifying activity and oil conversion rate. The strain Hl7-1 was identified as a Nocardia sp. based on the test for morphological, biochemical and physiological characteristics. It appears to be highly specialized for growth on crude oil in minimal salts medium since it showed preference for oil or degradation products as substrates for growth. It was found that it could grow on at least fifteen different hydrocarbons. The optimum cultural and environmental conditions were seeked. Cell growth and emulsification activity as a function of time were also determined. Crude oil degradation and the reduction of product peak was identified by the analysis of remnant oil by gas chromatography after 3 days of cultivation. Approximately 83% of oil were converted into a form no longer extractable by organic solvents.

  • PDF

Testing of CMOS Operational Amplifier Using Offset Voltage (오프셋 전압을 이용한 CMOS 연산증폭기의 테스팅)

  • Song, Geun-Ho;Kim, Gang-Cheol;Han, Seok-Bung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.1
    • /
    • pp.44-54
    • /
    • 2001
  • In this paper, a novel test method is proposed to detect the hard and soft fault in analog circuits. The proposed test method makes use of the offset voltage, which is one of the op-amps characteristics. During the test mode, CUT is modified to unit gain op-amps with feedback loop. When the input of the op-amp is grounded, a good circuit has a small offset voltage, but a faulty circuit has a large offset voltage. Faults in the op-amp which cause the offset voltage exceeding predefined range of tolerance can be detected. In the proposed method, no test vector is required to be applied. Therefore the test vector generation problem is eliminated and the test time and cost is reduced. In this note, the validity of the proposed test method has been verified through the example of the dual slope A/D converter. The HSPICE simulations results affirm that the presented method assures a high fault coverage.

  • PDF

Facial Expression Recognition using Face Alignment and AdaBoost (얼굴정렬과 AdaBoost를 이용한 얼굴 표정 인식)

  • Jeong, Kyungjoong;Choi, Jaesik;Jang, Gil-Jin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.193-201
    • /
    • 2014
  • This paper suggests a facial expression recognition system using face detection, face alignment, facial unit extraction, and training and testing algorithms based on AdaBoost classifiers. First, we find face region by a face detector. From the results, face alignment algorithm extracts feature points. The facial units are from a subset of action units generated by combining the obtained feature points. The facial units are generally more effective for smaller-sized databases, and are able to represent the facial expressions more efficiently and reduce the computation time, and hence can be applied to real-time scenarios. Experimental results in real scenarios showed that the proposed system has an excellent performance over 90% recognition rates.

Design of Stack Monitoring System with Improved Performance (성능이 향상된 Stack Monitoring System의 설계)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seong-Won;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.299-302
    • /
    • 2016
  • In this paper, we designed the stack monitoring system with improved performance. To block the incoming pulse noise to the amplifier, shield and the power supply impedance are reduced and the power circuit is isolated. The control unit is developed with variable high voltage, adaptive gain, offset and threshold in order to match the scintillation detector characteristic to the apparatus. 300-1500V variable high voltage power circuit is configured applicable to various scintillation detector. Stack monitoring system with improved performance guarantee the efficiency and the reliability by considering the characteristic of various scintillation detector. Developed stack monitoring system is evaluated with certified testing equipment and shows excellent performance with respect to the uncertainty of the sensor test results.

Quantification of 3D Pore Structure in Glass Bead Using Micro X-ray CT (Micro X-ray CT를 이용한 글라스 비드의 3차원 간극 구조 정량화)

  • Jung, Yeon-Jong;Yun, Tae-Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.11
    • /
    • pp.83-92
    • /
    • 2011
  • The random and heterogeneous pore structure is a significant factor that dominates physical and mechanical behaviors of soils such as fluid flow and geomechanical responses driven by loading. The characterization method using non-destructive testing such as micro X-ray CT technique which has a high resolution with micrometer unit allows to observe internal structure of soils. However, the application has been limited to qualitatively observe 2D and 3D CT images and to obtain the void ratio at macro-scale although the CT images contain enormous information of materials of interests. In this study, we constructed the 3D particle and pore structures based on sequentially taken 2D images of glass beads and quantitatively defined complex pore structure with void cell and void channel. This approach was enabled by implementing image processing techniques that include coordinate transformation, binarization, Delaunay Triangulation, and Euclidean Distance Transform. It was confirmed that the suggested algorithm allows to quantitatively evaluate the distribution of void cells and their connectivity of heterogeneous pore structures for glass beads.

Life Estimation of Elevator Wire Ropes Using Accelerated Degradation Test Data (가속열화시험 데이터를 활용한 엘리베이터 와이어로프 수명 예측)

  • Kim, Seung Ho;Kim, Sang Boo;Kim, Sung Ho;Ham, Sung Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.10
    • /
    • pp.997-1004
    • /
    • 2017
  • The life of elevator wire ropes is one of the most important characteristics of an elevator, which is closely related to the safety of users and its maintenance policy. It is not cost effective to measure the lifetime of elevator wire ropes during their use. In this study, the life estimation of elevator wire ropes (8x19W-IWRC) is considered using accelerated degradation test data. A bending fatigue tester is used to perform the accelerated degradation tests, incorporating the acceleration factor of tensile force. Assuming that the life of wire ropes is log-normally distributed, two life estimation methods are suggested and their results are compared. The first method estimates the life of wire ropes utilizing the accelerated life model with pseudo lives obtained from a linear regression model. The second method estimates the life using a logistic model based on failure probability.

EFFECT OF TWO OPAQUING TECHNIQUES ON METAL-CERAMIC BOND STRENGTH (Opaque 도재의 도포 방법이 치과용 합금과 도재간의 결합 강도에 미치는 영향)

  • Jang, Il-Seong;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.475-488
    • /
    • 1996
  • The opaque porcelain layer of porcelain-fused-to-metal(PFM) restoration is critical for the success of PFM restoration because it is the first layer placed over the treated alloy. But, the methods of opaquing technique have not been confirmed. Usually, the one layer method and two layer method have been used for the application of opaque porcelain. In the past, alloys with porcelain veneers which have been used successfully have contained various precious metals. Recent increase in the cost of precious metals stimulates considerable interest in nonprecious alloys. Although nickel-chromium alloys and nickel-chromium-beryllium alloys have been widely used, the use of cobalt-chromium alloys would be gradually increased with elimination of any potential risk of nickel-related allergic responses and/or beryllium-related toxic responses. This investigation examined one- and two-layer opaque porcelain applications to determine the effect on the bond strength of titanium added cobalt-chromium metal ceramic alloy. Bond strength of Ceramco II porcelain to titanium added cobalt-chromium alloy(2Dentitan) and gold-platinum-palladium alloy(Degudent H) were evaluated by direct shear bond strength test with Instron universal testing machine. The results were as follows; 1. When the mean shear bond strength of each experimental group were compared in $0.25cm^2$ unit area, the titanium added cobalt-chromium alloy/two layer method exhibited the greatest strength(79.7kg), followed by titanium added cobalt-chromium alloy/one layer method(76.2kg), gold-platinum-palladium alloy/two layer method(71.4kg), gold-platinum-palladium alloy/one layer method(64.2kg). 2. No significant differences in bond strength were recorded between the two opaquing techniques for gold-platinum-palladium alloy and titanium added cobalt-chromium alloy. 3. No significant differences in bond strength were recorded between the gold-platinum-palladium alloy and the titanium added cobalt-chromium alloy.

  • PDF

Recurrent ST segment elevations in a patient with asymptomatic early repolarization during head and neck surgery: implications of vasospastic angina

  • Park, Se-Ung;Kim, Sung-Hoon;Kwon, Hye-Mee;Koh, Gi-Ho;Nam, Gi-Byoung;Karm, Myong-Hwan;Kim, Wook-Jong;Ku, Seung-Woo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.3
    • /
    • pp.189-193
    • /
    • 2018
  • A 57-year-old woman scheduled for cochlear implant removal exhibited preoperative electrocardiographic findings of early repolarization (ER). Four episodes of transient ST segment elevations during surgery raised suspicion for vasospastic angina (VA). In the post-anesthetic care unit, the patient complained of chest discomfort and received sublingual nitroglycerin with uncertain effect. The patient refused to proceed with postoperative invasive coronary angiography, resulting in inconclusive diagnosis. Intraoperative circumstances limit the diagnosis of VA, which emphasizes the need for further testing to confirm the diagnosis. When VA is suspected in patients with underlying ER, it is reasonable to consider invasive examination to establish the diagnosis and prevent recurrence of VA. If ST changes are observed during surgery in patients with preoperative ER, careful monitoring is recommended. Due to general anesthesia, the absence of patient symptoms limits the definitive diagnosis of those with suspected VA. Therefore, additional postoperative surveillance is recommended.

Development of Nondestructive Detecting System for Elevator Wire Ropes using Hall-effect Sensors (Hall 센서를 이용한 엘리베이터 와이어 로프의 비파괴 검출시스템의 개발)

  • Kim, Sung-Duck
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.33-41
    • /
    • 2001
  • Wire ropes have been widely used in industrial applications, wherever heavy weight should be carried safely or mechanical energy should be transmitted fast. Especially, wire rope failures in operating elevator may lead to extensive property damage and serious injury to nearby personnel. Hence, it is very important to inspect wire rope periodically. Failure defection of wire rope requires fundamental knowledge of wire rope construction, rope behavior, properties of fault, sensing and signal processing method. In this research, the development of a new fault detecting system incorporating Hall-effect sensors to detect flaws such as abrasion, broken wire, corrosion and deformation for aged wire ropes in elevator, is described. For using a detector as a portable instrument, several performances for implementing sensing part with Hall-effect sensor, analog signal processing unit and programs are described. Experiments and field testing results for the implemented detecting system are also given. As a result, it is verified that the detecting system has good efficiency for inspecting faults of aged wire ropes in service.

  • PDF

Changes of Afferent Transmission to the SI Cortex by Transient Co-Stimulation of Receptive Field Center and Outside in Anesthetized Rats

  • Yang, Yu-Mi;Lim, Sa-Bina;Won, Chung-Kil;Shin, Hyung-Cheul
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • We have characterized the aftereffects of impulse activities on the transmission of afferent sensory to the primary somatosensory (SI) cortex of the anesthetized rats (n=22). Following conditioning stimulation (CS, 10 sec, either 5 Hz or 200 Hz) to the receptive field (RF), quantitative determination of the changes of afferent sensory transmission was done by generating post-stimulus time histogram of unit response to the testing stimulation (TS, at 0.5 Hz) to the RF center (RFC) for 60 min. In one group of experiments, CS was delivered to the RF center (RFC). In another group of experiments, CSs were simultaneously given to both RFC and RF outside (RFO, either forepaw or hindpaw). CS of 5 Hz to RFC exerted irreversible facilitation of sensory transmissions evoked by TS. Simultaneous CSs of 5 Hz to RFC and hindpaw RFO exerted reversible suppression of afferent transmission. However, CSs of 5 Hz to RFC and forepaw RFO did not significantly altered afferent sensory transmission to SI cortex neurons. CS of 200 Hz to RFC exerted irreversible suppression of sensory transmissions up to 60 min of experimental period. Simultaneous CSs of 200 Hz to RFC and RFO did not significantly altered afferent sensory transmission to SI cortex neurons. The profiles of CS-induced modulation of afferent sensory transmission were significantly different between two CS conditions. Thus, this study suggests that activity-dependent modulation of afferent transmission from a RF center to the SI cortex may be significantly altered when remote body part was simultaneously activated.

  • PDF