A Comparison of Noise Level by Noise Measuring Methods (소음측정방법에 따른 평가소음도 비교)

  • Shim, Chur Goo;Roh, Jae hoon;Park, Jung Gyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.128-136
    • /
    • 1995
  • The purpose of this study is to evaluate the difference of noise level according to noise measuring methods in the noisy working environments. Sound pressure level(SPL), equivalence sound level(Leq) and personal noise exposure dose(Dose) in the fifty-nine unit workplaces of the twenty-eight industries were measured and relating factors which were affected noise level were investigated. The results were as follows ; 1. The noise levels were $88.70{\pm}5.68dB(A)$ by SPL, $89.07{\pm}5.41dB(A)$ by Leq and $89.07{\pm}5.69$ by Dose. The differences of noise levels by three measuring methods were statistically significant(P<0.001) by repeated measure ANOV A. 2. Comparing with noise levels by general classes of noise exposure, noise levels of continuous noise were $89.14{\pm}5.19dB(A)$ by SPL, $89.45{\pm}4.65dB(A)$ by Leq and $90.04{\pm}5.09$ by Dose. Noise levels of intermittent noise were $87.90{\pm}6.52dB(A)$ by SPL, $88.40{\pm}6.63dB(A)$ by Leq and $90.10{\pm}6.80$ by Dose. The differences noise level of noise measuring methods by general classese of noise exposure were statistically not significant by repeated measure ANOV A. 3. Interaction between general classese of noise exposure and noise measuring methods for noise level was not statistically significant by repeated measure ANOVA. And the noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001) 4. Comparing with noise levels by unit workplace size, noise levels of large unit workplace were $90.73{\pm}5.87dB(A)$ by SPL, $91.32{\pm}5.50dB(A)$ by Leq and $91.82{\pm}6.06$ by Dose and noise levels of middle unit workplace were $88.31{\pm}5.26dB(A)$ by SPL, $88.41{\pm}4.83dB(A)$ by Leq and $89.69{\pm}5.05$ by Dose. And noise levels of small unit workplace were $94.89{\pm}4.10dB(A)$ by SPL, $85.35{\pm}4.11dB(A)$ by Leq and $86.87{\pm}4.98$ by Dose. The noise level differences of noise measuring methods by unit workplace size were statistically significant by repeated measure ANOV A(P<.05). 5. The noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001). But Interaction between workplace size and noise level measuring methods for noise level was not statistically significant by repeated measure ANOVA. According to the above results, there was a difference of the noise level among the three measuring methods. Therefore we must use the personal noise exposure dose using by noise dose meter, possible, to prvent occupational hearing loss in noisy working environment.

  • PDF

The effect of process parameters on copper powder particle size and shape produced by electrolysis method

  • Boz, Mustafa;Hasheminiasari, Masood
    • Steel and Composite Structures
    • /
    • v.15 no.2
    • /
    • pp.151-162
    • /
    • 2013
  • In this study, an electrolyzing device for the production of metal powders was designed and fabricated. The production of copper powders was performed using a variety of current densities, anode-cathode distances and power removal times. The effect of these parameters on powder particle size and shape was determined. Particle size was measured using a laser diffraction unit while the powder shape was determined by SEM. Experimental results show that an increase in current density leads to a decrease in powder particle size. In addition particle shape changed from globular dendritic to acicular dendritic with increasing the current density. Distance between the cathode and anode also showed a similar influence on powder particle size and shape. An increase in time of powder removal led to an increase in powder particle size, as the shape changed from acicular dendritic to globular dendritic.

Unit Root Test for Temporally Aggregated Autoregressive Process

  • Shin, Dong-Wan;Kim, Sung-Chul
    • Journal of the Korean Statistical Society
    • /
    • v.22 no.2
    • /
    • pp.271-282
    • /
    • 1993
  • Unit root test for temporally aggregated first order autoregressive process is considered. The temporal aggregate of fist order autoregression is an autoregressive moving average of order (1,1) with moving average parameter being function of the autoregressive parameter. One-step Gauss-Newton estimators are proposed and are shown to have the same limiting distribution as the ordinary least squares estimator for unit root when complete observations are available. A Monte-Carlo simulation shows that the temporal aggregation have no effect on the size. The power of the suggested test are nearly the same as the powers of the test based on complete observations.

  • PDF

A Study on the Design of Apartment Housing Units Based on the Regional Characteristics (지역성을 반영한 공동주거 평면디자인 개발을 위한 연구 -POE를 이용한 거주자 평가를 기초로 -)

  • 오찬옥
    • Korean Institute of Interior Design Journal
    • /
    • no.40
    • /
    • pp.76-85
    • /
    • 2003
  • This study was intended to suggest the design alternatives of housing units which were developed on the basis of POE. The POE of the New Apartment Complex in Gimhae was carried out and on the basis of the results of this POE, the design alternatives of housing units were developed. The subjects were 372 housewives who live in the apartment houses sized 60m2 to 85m2 in Gimhae. They answered about the living characteristics related to house, the degree of saisfaction with their housing unit plans, and the needs for housing unit plan. The major problems in current housing unit were the lack of storage space and the small size of living room and children's bedrooms. Many residents wanted to live in the housing unit which have three bedrooms and some of them wanted two bedrooms. Also, they wanted to enlarge living room and instead of that, to reduce master bedroom. In addition to these, the residents had diverse housing needs. On the basis of these results, housing alternatives which are flexible and optionable were suggested.

LCD backlighting system with high luminance and good uniformity (LCD backlight unit의 고분자 산란형 도광판에 관한 연구)

  • Jung, Il-Yong;Park, Woo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.173-176
    • /
    • 2000
  • we analyzed multiple ray tracing in the highly scattering optical transmission(HSOT) polymer plate by means of the Monte carlo simulation. Light transmission behavior in the light guide was simulated by a 3-dimensional ray tracing program considering scattering angle given by the Mie theory and mean free path. To improve the uniformity of the conventional HSOT backlight unit, We employed additionally dot patterns. For the proposed structure, we calculated the light transmission behavior and obtained a bright and uniform backlight unit for a large size LCD panel of more than 12 inch.

  • PDF

A Study on Unit Plan of the New Trend Apartment Housing (공동주거유형의 다양화에 관한 사례조사 연구)

  • 권철범;김용성
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2000.11b
    • /
    • pp.85-89
    • /
    • 2000
  • After 1980's, the progress in quantities of apartments were made by the housing construction expediting policies. But, the qualities of apartments were neglected and the plan of apartments were uniformed by the economical aspects. Apartment unit plans were designed standardized by the reasons of economical efficiency, structural methods and sales. Therefore apartments could not deal effectively with increasing demands for qualities of the residents. Absence of aesthetical values and fixed unit plans on regardless of the residents family compositions and the size of the apartments were occurred. So the new types of the apartment plans are needed to suit the changes and diversities of living. The purpose of this study is to extract the design factors for future apartment by analyzing the unit plans of apartment housings today.

  • PDF

A Design of an Automotive Wheel Bearing Unit for Long Life (자동차 휠 베어링 유닛의 장수명 설계)

  • Yun, Gi-Chan;Choe, Dong-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.319-328
    • /
    • 2000
  • This paper presents a new design method of the 1 generation wheel bearing unit using a numerical optimization technique in order to increase bearing fatigue life. For calculating the fatigue life, a method of load analysis is studied on the automotive wheel bearing system. The design variables selected are ball size, initial contact angle, number of balls, pitch diameter, pre-load, and distance between ball centers. The method of feasible directions in ADS (Automated Design Synthesis) is utilized to automatically find the optimum design variables. To validate the design method, a computer program is developed and applied to a practical passenger car model. The optimum design results demonstrated the effectiveness of the proposed design method showing that the system life of the optimally designed wheel bearing unit is enhanced in comparison with that of the initial ones within the given available design space.

Engineering Model Design and Implementation of Telemetry-Command Unit for STSAT-2 (과학기술위성 2호 원격검침-명령 유닛 시험모델 설계 및 구현)

  • Oh, Dae-Soo;Ryu, Chang-Wan;Nam, Myeong-Ryong;Hwang, Dong-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.5
    • /
    • pp.93-98
    • /
    • 2005
  • An Engineering Model(EM) of the Telemetry-Command Unit(TCU) for STSAT-2 was developed. The TCU of STSAT-2 has some improved features compared with that of STSAT-1. To reduce weight and size of TCU all logics are implemented in FPGA without CPU. EM I&T(Integration and Test) was successfully performed with no errors.

Design of CVT Composed of a K-H-V type Differential Gear Unit and a V-Belt Drive (K-H-V형 차동기어장치와 V-벨트식 기구를 결합한 무단변속기의 설계)

  • 김연수;박재민;정찬길;최상훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.799-802
    • /
    • 2002
  • Continuously variable transmission(CVT) mechanisms considered here combine the functions of a K-H-V type differential gear unit and a V-belt type continuously variable unit(CVU). As combining the functions of a K-H-V type differential gear unit and a V-belt type CVU, 24 different mechanisms are presented. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed. These mechanisms have many advantages which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral.

  • PDF

An Analysis of the Preferential Unit Planning Components of High-rise Residential Buildings Across Family Life Cycle Stages (가족생활주기별 아파트 단위주호 계획요소 선호분석)

  • Lee Yeunsook;Lee Hyunjeong;Lee Jeeyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.2 s.49
    • /
    • pp.120-127
    • /
    • 2005
  • The purpose of this study was to examine preferential unit planning components of high-rise residential buildings across family life cycle stages. The questionnaire survey was adopted in this study, and 110 cases were used for data analysis. Based on the age of the oldest child, the family life cycles used in the study were divided into four stages: early childhood, elementary school, adolescence, and adulthood. The findings showed that the preference of the unit planning components across the stages was distinct; families in the stage of early childhood and adolescence had the growing needs for spatial features, and regarded living-related features as important. Families in the stage of adulthood tended to have larger spaces. It was noticed that unit planning components needed to be more differential when the combined effect of both family life cycle stages and housing size was considered.