• Title/Summary/Keyword: unit quantity of water

Search Result 100, Processing Time 0.036 seconds

Efficient Unit-Water Management Method for Stabilizing the Quality of Ready-mixed Concrete (레미콘 품질 안정화를 위한 효율적인 단위수량 관리 방안)

  • Choi, Sung-Woo;Ryu, Deug-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.327-328
    • /
    • 2021
  • In the manufacturing process of ready-mixed concrete, quantity management directly affects the workability and strength of concrete. Therefore, water quantity is the most important management factor for water quality control of ready-mixed concrete. It can be said that the number of unit water in the mix design, the water quantity due to the surface water contained in the aggregate used, and the water quantity taking into account the concentration of sludge contained in the recycling water when using the recycling water are factors that affect the quantity management of ready-mixed concrete. In this study, as a stable quality control method of ready-mixed concrete, a quantity management method by aggregate surface water and a sludge concentration management method according to the use of recycling water were proposed. Thus, we tried to suggest an efficient quantity management method for stabilizing the quality of ready-mixed concrete.

  • PDF

An Experimental Study on the Accuracy of Concrete Unit-Water Content Using High-frequency Water Fraction Sensors (고주파수분센서를 이용한 콘크리트 단위수량 평가 정확도에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.61-62
    • /
    • 2022
  • The unit quantity is an important factor influencing the durability, workability, and quality of concrete. Methods for measuring the unit quantity include a high frequency heating method, a unit volume mass method, a capacitance method, and a microwave method. However, these methods have disadvantages of poor measurement method, time required, and accuracy, and a relatively experimental method compensating for these disadvantages was used to measure the unit quantity using a high frequency main sensor (FDR) capable of simple and fast measurement. In addition, the unit quantity was evaluated by analyzing the measurement data through deep learning.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content Acoording to Concrete Aggregate Variables through FDR Sensor (FDR 센서를 통한 콘크리트 골재 변수에 따른 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.70-71
    • /
    • 2021
  • The unit quantity that affects the workability, shrinkage cracking, and durability of concrete is an important factor. Methods for measuring the unit quantity include a high frequency heating method, a capacitance method, a unit volume mass method, and a simple method. However, these methods have the disadvantage of poor measurement method, time required, and precision. To solve this problem, a relatively simple and fast measurement method was adopted to compensate for the shortcomings through a Frequency Domain Reflection (FDR) sensor, and the unit quantity was used. In addition, the measurement data was analyzed by deep learning to evaluate the unit quantity of concrete.

  • PDF

A Stochastic Analysis of the Water Quality on the Basin of Soyang River with Discharge Variation (유량변동에 따른 소양강유역 수질의 통계학적 해석)

  • Choi, Han-Kyu;Baek, Kyung-Won;Choi, Yong-Mook;Choi, Jin-Woo
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.233-240
    • /
    • 2001
  • This research was conducted with the aim of efficiently managing large scale of rivers such like Songyang-river through predicting water quality change with analyzing the characteristics of the flowing in nutrients and pollutants. The main result will be used as basic data for effectively operating reservoirs through controling water quality and quantity. The relationship between quantity of flow and water quality was analyzed and pollution loading into the basin was estimated. Three areas of Soyang-river upstream and one area of Suip-cheon in Yanggu-gun were selected as research sites. Flow and water quality were measured simultaneously. The relation between quantity of discharge and pollution concentration and between quantity of discharge and pollution loading were analyzed by statistical method, respectively. We provided a rating curve through measuring quantity of discharge(collecting quantity of discharge) and pollutograph and pollution loading curve through water quality data. Also, we analyzed the correlation between quantity of discharge per unit area and pollution loading per unit area in each basin. As resurt of this research, Buk-cheon spot revealed an excellent first grade water quality for the items including $BOD_5$, DO, and SS. The correlation coefficient between Buk-cheon spot's quantity of discharge and pollution loading was 0.896~0.996, showing the validity of analysis applying correlation curve formula of quantity of discharge and pollution loading in the same spot. Also, pollution loading per unit area of the items including $BOD_5$, COD, DO, SS, T-N, T-P increased as the area of basins get increased following the sequence of Buk-cheon, Suip-cheon, Naelin-cheon spots.

  • PDF

A Study on the status of unit water content control of the Ready-Mixed Concrete plants in the country (국내 레미콘 플랜트의 단위수량관리 현황 검토에 관한 연구)

  • Jung, Yang-Hee;Kim, Yong-Ro;Choi, Il-Ho;Lee, Do-Bum;Hong, Kyung-Seon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.606-609
    • /
    • 2006
  • In this study, it was selected that in order to make an investigation into the status of the unit water content control of the ready-mixed concrete plants in the country, Capacitance Measurement Method out of various methods which are able to gauge the amount of unit water content in fresh concrete. Then, it were estimated that the quantity of unit water in fresh concrete and the technical standard of every mixture design of the six ready-mixed concrete plants chosen at random in the country. Finally, based on this study, it was proposed as fundamental data to utilize measurement techniques of the quantity of unit water for the quality control of the ready-mixed concrete in construction field.

  • PDF

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

Effects of the Water Reducing Agent on the Concrete (減水劑가 콘크리트에 미치는 影響)

  • Kim, Jong-Cheon;Doh, Duk-Hyun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 1982
  • A study on the effect of water reducing agent on the various characteristics of concrete has been conducted. The experimental results of the study are summarized as follows. 1. Slump test for the concrete added water reducing setretarding agent in proper quantity have been conducted. According to the test results, the decreasing rate of slump value become bigger than plain concrete with increase of the unit weight of cement and elapse of time 2. In case the proper quantity content of maximum compressive strength in Fig. 5 of water reducing set retarding agent is added, unit weight of water is decreased about 15% or so as compared with plain concrete. with the increase of water reducing set accelerating agent content unit weight of water is decreased much more, And other hand, amount of air entraining shows the increasing tendency with the increase of water reducing agent content. 3. The adding rate of water reducing agent which produce maximum strength shows that WR-CH and WR-SA which is water reducing set-starding agent is 0.2% and WR-CO is 0.5% and that WS-PO which is water reducing set accelerating agent is 0.5 4. compressive strength jof the concrete made of sulfate resistant cement shows less than the strength of normal portland cement at initial strength but the strength of both cement shows almost same at curing age of 28 days. 5. when proper quantity of water reducing set retarding agent is used, boned strength is increased about 15% at curing age of 28days. 6. According to the result of durability test, dynamic young's mudulus of elasticity at plain concrete is decreased about 50% as compared with initial step at 300 cycle of freezing and thawing after curing age of days. on the contarary the concrete used water reducing agent is decreased less than 7%.

  • PDF

An Effect on the Properties of Antiwashout Underwater Concrete by mixing time and mixing quantity (배합시간과 배합량이 수중불분리성 콘크리트의 특성에 미치는 영향)

  • 박세인;김동명;김종수;김명식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.345-350
    • /
    • 2000
  • The objective of this study makes investigation into the effect on the properties of underwater antiwashout concrete. which is followed by mixing time and mixing quantity. There is an tendency that (the compressive strength of underwater antiwashout concrete made and cured in fresh water or sea water) is increase when dry mixing time, mixing quantity, total mixing time is increase as unit weight grows. The difference of compressive strength (in case of no dry mixing time and 60 second) is averagely 46.8kgf/㎠ in the fresh water and 35.6kgf/㎠ in sea water. it's considered that dry mixing is dispersed by underwater antiwashout admixture.

  • PDF

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

Basic and Strength Properties of aggregates from Various locations in sud-Korea (국내 남부지역의 골재원 변화에 따른 보통콘크리트의 기초 및 강도특성)

  • Jo, Man-Ki;Song, Yuan-Lou;Park, Young-Jun;Lee, Hong-Kyu;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.145-146
    • /
    • 2015
  • When using non KS aggregate muck pile in general, compared to when using KS aggregate, when obtaining an identical slump a high unit quantity of water was confirmed, and when designing the concrete mix the compressive strength of concrete decreased due to an increase in W/B. Therefore because the use of non KS aggregate decreases the liquidity, strength and durability etc. qualities of concrete from an overall performance point of view, there is a need for the used of KS aggregate and when using aggregate that does not adhere to KS standards, it is determined there is a need for appropriate concrete mix design and care.

  • PDF