• 제목/요약/키워드: unit pulse

검색결과 330건 처리시간 0.024초

재생골재와 산업부산물을 사용한 콘크리트의 물리.역학적 특성 (Physical and Mechanical Properties of Concrete Using Recycled Aggregate and Industrial By-Products)

  • 성찬용;김영익
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.128-135
    • /
    • 2003
  • This study is performed to examine the physical and mechanical properties of concrete using recycled aggregate and industrial by-products. The test results show that the unit weight, compressive and flexural strength, ultrasonic pulse velocity and dynamic modulus of elasticity are decreased with increasing the content of recycled aggregate. But, the absorption ratio is increased with increasing the content of recycled aggregate. The unit weight is 2,237∼2,307 kg/$\textrm{m}^3$, the absorption ratio is 2.96∼4.12%, the compressive strength is 415∼532 kgf/$\textrm{cm}^2$, the flexural strength is 75∼96 kgf/$\textrm{cm}^2$, the ultrasonic pulse velocity is 4,350∼4,949 m/s and the dynamic modulus of elasticity is $390\times10^3\;∼\;465\times10^3$ kg f/$\textrm{cm}^2$, respectively These recycled aggregate concrete can be used for high strength concrete.

Study on Timing Characteristics of High-Voltage Pulse Generation with Different Charging Voltages

  • Lee, Ki Wook;Kim, Jung Ho;Oh, Sungsup;Lee, Wangyong;Kim, Woo-Joong;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • 제18권1호
    • /
    • pp.20-28
    • /
    • 2018
  • The time synchronization of each sub-unit of a pulsed generator is important to generate an output high-power radio frequency (RF) signal. To obtain the time synchronization between an input RF signal fed by an external source and an electron beam produced by an electric pulse generator, the influence of different charging voltages on a delay and a rise time of the output pulse waveform in the electric pulse generator should be carefully considered. This paper aims to study the timing characteristics of the delay and the rise time as a function of different charging voltages with a peak value of less than -35 kV in the high-voltage pulse generator, including a trigger generator (TG) and a pulse-forming line (PFL). The simulation has been carried out to estimate characteristics in the time domain, in addition to their output high-voltage amplitude. Experimental results compared with those obtained by simulation indicate that the delay of the output pulses of the TG and PFL, which are made by controlling the external triggering signal with respect to different charging voltages, is getting longer as the charging voltage is increasing, and their rise times are inversely proportional to the amplitude of the charging voltage.

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

공진형 직류 링크 인버터의 공진 펄스 제어기 (A novel resonant pulse control in resonant DC link inverter)

  • 유동욱;원충연
    • 전자공학회논문지B
    • /
    • 제33B권5호
    • /
    • pp.152-158
    • /
    • 1996
  • A novel resonant pulse control technique which generates high-quality sinusoidal output voltage from a resonant dc link inverter is presented for UPS applicatons. The proposed control technique limits resonant voltae overshoot without any passive or active clamp circuit, resulting in resonant pulses iwth uniform amplitude and high efficiency. The output voltage is controlled by the third order contorller iwth an inner loop of th efilter inductor current and the feedforward controller. Analysis and design of the proposed control technique are illustrated and verified on a 5kVA experimental unit.

  • PDF

수중 데이터 통신 시스템의 개발에 관한 연구 (I) -에코 신호 전송 시스템- (development of Underwater Data Communication System (I) -Echo Signal Transfer System-)

  • 신현옥
    • 수산해양기술연구
    • /
    • 제35권3호
    • /
    • pp.284-290
    • /
    • 1999
  • This paper describes a Frequency Shift Keying (FSK) modulator and demodulator and the experimented underwater data ommunication equipment to transfer the analog echo signal in real-time from an underwater vehicle to the mother ship. The system consists of an echo signal transfer unit equipped to the vehicle and an ultrasonic receiver equipped on the ship. The former includes an ultrasonic transceiver unit of 180kHz for echo detection and a continuous wave transmitter of 50kHz with a FSK modulator for echo transmission to the ship. The latter includes an ultrasonic receiver of 50kHz and the FSK demodulator. The results of experiment are as follows. 1. The characteristics of the FSK modulating and demodulating circuits designed with the use of C-MOS IC 4046 was good and confirmed its usefulness in underwater data communication system.2. The prototype ultrasonic transceiver unit shows profitable driving power while the pulse duration was short less than 3 msec, but it was found that the driving power is not sufficient while the long pulse duration or continuous wave is used. The gain of the ultrasonic receiver was 80 dB and the receiving bandwidth 700Hz (at - 3 dB point).3. It was found that the system designed by the author has some possibility to use in underwater echo transfer.4. At the FSK modulator, the widths of voltage and frequency which represent linearity were 3.5 V, 1600Hz, respectively, at the FSK demodulator 2.6 V, 700Hz, respectively.

  • PDF

수중 데이터 통신 시스템의 개발에 관한 연구 (I) -에코 신호 전송 시스템- (development of Underwater Data Communication System (I) -Echo Signal Transfer System-)

  • 신현옥
    • 수산해양기술연구
    • /
    • 제35권3호
    • /
    • pp.285-285
    • /
    • 1999
  • This paper describes a Frequency Shift Keying (FSK) modulator and demodulator and the experimented underwater data ommunication equipment to transfer the analog echo signal in real-time from an underwater vehicle to the mother ship. The system consists of an echo signal transfer unit equipped to the vehicle and an ultrasonic receiver equipped on the ship. The former includes an ultrasonic transceiver unit of 180kHz for echo detection and a continuous wave transmitter of 50kHz with a FSK modulator for echo transmission to the ship. The latter includes an ultrasonic receiver of 50kHz and the FSK demodulator. The results of experiment are as follows. 1. The characteristics of the FSK modulating and demodulating circuits designed with the use of C-MOS IC 4046 was good and confirmed its usefulness in underwater data communication system.2. The prototype ultrasonic transceiver unit shows profitable driving power while the pulse duration was short less than 3 msec, but it was found that the driving power is not sufficient while the long pulse duration or continuous wave is used. The gain of the ultrasonic receiver was 80 dB and the receiving bandwidth 700Hz (at - 3 dB point).3. It was found that the system designed by the author has some possibility to use in underwater echo transfer.4. At the FSK modulator, the widths of voltage and frequency which represent linearity were 3.5 V, 1600Hz, respectively, at the FSK demodulator 2.6 V, 700Hz, respectively.

Performance improvement of 2 stage GM-type pulse tube Cryocooler for cryopump

  • Park, Seong-Je;Koh, Deuk-Yong;Suh, Jeong-Kyoon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권4호
    • /
    • pp.30-35
    • /
    • 2011
  • This paper describes experimental study and performance improvement of 2 stage Gifford-McMahon (G-M) type pulse tube cryocooler for cryopump. The objective of this study is to improve the efficiency of 2 stage pulse tube cryocooler for substituting 2 stage G-M cryocooler used in cryopump. The target cooling capacities are 5 W at 20 K and 35 W at 80 K for the $1^{st}$ and the $2^{nd}$ stage, respectively. These values are good cooling capacities for vacuum level in medium size ICP 200 cryopump. Design of the 2 stage pulse tube cryocooler is conducted by FZKPTR(Forschungs Zentrum Karlsruhe Pulse Tube Refrigerator) program. In order to improve the performance of 2 stage pulse tube cryocooler, U-type pulse tube cryocooler is fabricated and connecting tubes are minimized for reducing dead volumes and pressure losses. Also, to get larger capacities, orifice valves and double inlet valves are optimized and the compressor of 6 kW is used. On the latest unit, the lowest temperatures of 2 stage pulse tube cryocooler are 42 K ($1^{st}$ stage) and 8.3 K ($2^{nd}$ stage) and the cooling capacities are 40 W at 82.9 K ($1^{st}$ stage) and 10 W at 20.5 K ($2^{nd}$ stage) with 6.0 kW of compressor input power. This pulse tube cryocooler is suited for commercial medium size cryopump. In performance test of cryopump with 2 stage pulse tube cryocooler, pumping speed for gaseous nitrogen is 4,300 L/s and the ultimate vacuum pressure is $7.5{\times}10^{-10}$ mbar.

전차대대 주요체계의 EMP 방호능력 발전방안에 관한 연구 (The Development of Electromagnetic pulse Protection Capability in the Main System of a Tank Battalion)

  • 최호갑;한재덕;손상우;김성곤
    • 대한토목학회논문집
    • /
    • 제40권6호
    • /
    • pp.623-631
    • /
    • 2020
  • 핵무기 공격 시나 전자폭탄의 공겨 시 발생하는 전자기펄스(EMP: electromagnetic pulse)는 무기체계, 정보기기, 유·무선 통신장비, 전력공급 장비 등에 영향을 주어 전장에서 혼란을 초래하게 한다. 지금까지의 군에 적용 중인 EMP 방호에 대한 기준은 고정 및 이동시설과 장비를 중심으로 되어 있어 무기체계 중심의 단일 전술제대에 대한 EMP 방호 소요에 대한 연구가 필요한 실정이다. 본 연구에서는 전술제대 중 기동력과 화력, 충격력을 지닌 전차대대의 전차와 지휘용장갑차를 중심으로 EMP에 취약한 지휘통제, 기동, 화력체계에 대하여 EMP 방호기준을 설정하고, EMP 차폐 및 차단 등 EMP 방호능력 발전방안을 구체적으로 제시하였다. 이를 통해 EMP 상황하 부대 지휘통제와 부대원의 생존성을 보장하고 임무수행 여건을 보장하고자 한다.

FTIR을 이용한 복합레진의 중합도 비교 (THE COMPARISON OF LIGHT-CURED COMPOSITE RESIN POLYMERIZATION BY FTIR)

  • 이주현;박호원
    • 대한소아치과학회지
    • /
    • 제30권2호
    • /
    • pp.245-253
    • /
    • 2003
  • 치과용 복합레진의 중합률은 레진 기질내의 이중결합의 전환도를 나타내는 것으로 이는 재료의 물리적 성질과 기계적 성질 및 생체 친화성에 영향을 미친다. 레진의 중합도가 증가하면 취성과 수축이 증가하고 중합도가 낮으면 기계적 물리적 성질이 감소한다. 따라서 본 연구에서는 광중합형 복합레진을 사용하여 플라즈마 아크 중합기 2종, 할로겐 중합기 2종, LED 중합기 2종, pulse-delay curing의 서로 다른 중합방법의 경우를 FTIR 분석법으로 복합레진의 물리적 기계적 성질 및 생체친화성에 영향을 미치는 중합률을 분석하여 다음과 같은 결과를 얻었다. 1. 광중합 복합레진의 중합률은 FTIR로 측정하였을 때 34.52-49.31%사이로 나타났으며 플라즈마 아크 중합의 경우 Flipo는 $39.96{\pm}1.22%$, CrediII는 $45.64{\pm}1.34%$로, 할로겐 중합시 XL3000은 $43.48{\pm}1.34%$, VIP의 mode 4 사용시는 $44.31{\pm}0.72%$, LED의 LUXOMAX는 $49.31{\pm}2.37%$, Elipar Freelight는 $44.51{\pm}0.62%$, pulse-delay curing시에는 $34.52{\pm}0.85%$로 나타났다. 2. 각 중합 방법별로 중합률은 LED 중합 방법을 이용한 LUXOMAX가 다른 실험군에 비하여 가장 높은 중합률을 나타냈으며 pulse-delay curing 방법이 가장 낮은 중합률을 보였다. 3. Flipo 중합기, LUXOMAX 중합기, pulse-delay curing 방법이 다른 중합기와 비교하여 통계적으로 유의한 차이를 보였다(p<0.05). 4. 각 중합방법이 동일한 군 내의 중합기기별 차이에서는 할로겐에서는 광중합기 사이에 중합률의 차이를 보이지 않았으나 플라즈마 아크에서는 CrediII가, LED에서는 LUXOMAX가 중합률이 높았다(p<0.05).

  • PDF

기능적전기자극을 이용한 보행훈련이 편마비 환자의 하퇴근육의 근전위활동에 미치는 영향 (Influence of Functional Electrical Stimulation during Gait Training on Motor Unit Action Potential)

  • 강양훈;서삼기;이정우;윤세원;김용억;김태열
    • 대한임상전기생리학회지
    • /
    • 제5권1호
    • /
    • pp.33-43
    • /
    • 2007
  • This study divided 35 hemiplegia patients into control group having standard physical therapy and gait training and functional electrical stimulation(FES) group using FES during gait training in order to examine the effects of applying FES to ankle joint dorsiflexor on motor unit action potential. Stimulation conditions of FES were pulse rate 35 pps, pulse width $250{\mu}s$, and on-time 0.3 second, treatment hour was 30 min. and treatment period was once a day for five days a week through six weeks. For functional evaluations before and after treatment, root mean square(RMS) were measured and the following conclusions were obtained. : In RMS analysis of motor unit action potential, gastrocnemius was significantly reduced in both weight bearing(p<.001) and bearing condition (p<.05). In conclusion, application of FES to hemiplegia patients in recovery stage during gait training decreased RMS and it was interpreted that it was caused by mitigation of muscular spasticity by reduction of motor unit.

  • PDF