• Title/Summary/Keyword: unit pulse

Search Result 330, Processing Time 0.024 seconds

Engineering Properties of Surlightweight Polymer Concrete (초경량 폴리머 콘크리트의 공학적 특성)

  • 성찬용;김경태
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.4
    • /
    • pp.75-81
    • /
    • 1997
  • This study was performed to evaluate the engineering properties of surlightweight polymer concrete using synthetic lightweight aggregate. The following conclusions were drawn; 1. The unit weight was in the range of 0.849~0.969t/$m^3$, the unit weights of those concrete were decreased by 58 ~ 63% than that of the normal cement concrete. 2. The highest strength was achieved by $P_1$, and compressive strength was increased by 93% and bending strength by 364% than that of the normal cement concrete, respectively. 3. The ultrasonic pulse velocity was in the range of 2, 346~2, 702m/s, which was low compared to that of the normal cement concrete. 4. The dynamic modulus of elasticity was in the range of $1.561{\times} 10{^5}~1.916{\times} 10{^5}kgf/cm^2$, which was approximately 52~98% of that of the normal cement concrete. 5. The compressive and bending strength were increased with the increase of unit weight. But, the dynamic modulus of elasticity and ultrasonic pulse velocity were decreased with the increase of unit weight.

  • PDF

The Power Supply System for Xenon Lamp Light Sintering (광소결용 제논 램프 구동을 위한 파워 서플라이 시스템)

  • Cho, Chan-Gi;Song, Seung-Ho;Park, Su-Mi;Park, Hyeon-Il;Bae, Jung-Soo;Jang, Sung-Roc;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.327-328
    • /
    • 2017
  • This paper presents the power supply system which is made of three units: the capacitor charging and main pulse unit, simmer power supply unit, and series trigger unit. The capacitor charging and main pulse unit charges the capacitor bank by using the series parallel resonant converter and the generated main pulses apply to the lamp. The series trigger unit ionize the xenon gas located in the lamp and the simmer power supply unit sustains the ionized condition. It means that the lamp lifetime and efficiency are advanced by reducing the number of triggering. Not only the operation of the proposed system but also the performance of each unit will be verified by the experimental results.

  • PDF

Compact Size Nanosecond Rise Time Hgh Voltage Pulse Generator (소형 나노초 입상 고전압 펄스발생장치)

  • Park, Sung-Lok;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1819-1821
    • /
    • 1996
  • A compact size high voltage pulse generator with nanosecond rise time has been fabricated and investigated experimentally. It can be reduced the inductance of the generator by fixing the Marx generator components and pulse forming network components into a single cylindrical unit. As a result, it can be obtained nanosecond rise time about $8{\sim}10[ns]$ and pulse width of several hundred nanoseconds from the modified Marx pulse generator. And parametric studies showed that the rise time of the output pulse was depended little on the change of the load resister and the charging capacitor while the pulse width of the output pulse was depended greatly upon the change of the load resistor and the charging capacitor.

  • PDF

Mini loop coil magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료기)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.49-51
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse torn and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Analysis for the Pulse-Jet Cleaning Flow of a Hot Gas Ceramic-Filter Element (고온고압 세라믹 여과재 탈진 과정의 유동 해석)

  • Park I. W.;Ryu J. H.;Choi D. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.110-115
    • /
    • 1998
  • An axisymmetric Navier-Stokes procedure has been developed to analyze the pulse jet flow in a ceramic filter unit for the dust dislodging process. Using Baldwin-Lomax turbulence model as a closure relationship, the SIAF(Scalar Implicit Approximate Factorization) algorithm together with the ${\delta}^k-Correction$ iterative time marching scheme is adopted to solve the unsteady compressible Navier-Stokes equations. After some validation tests, the code has been applied to solve the pulse jet flow and examine the effects of geometry and reservoir pressure condition on the pressure level inside the filter unit. To avoid dealing with the uncertainty of such factors as the cohesion of the collected dust and the adhesion of the dust to the medium and also to simplify the analysis, the filter wall is assumed to be impermeable. The results for various test cases are presented.

  • PDF

A Study on the Pore Structure of Recycled Aggregates Made of EPS Waste and Insulation Performance of Lightweight Concrete (폐 EPS 재생골재의 공극구조와 경량골재큰크리트의 단열성능에 관한 연구)

  • 탁현철;정민수;안재철;강병희
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.91-96
    • /
    • 2002
  • This study is to investigate the insulation performance of lightweight concrete using recycled lightweight aggregate, to develop lightweight concrete products which have an excellence on the insulation performance are satisfied with properties of building materials. As a result of this study, recycled EPS aggregate is considered to have an independent pores which is closed by dense partitions. So, it is showed that the insulation performance of lightweight concrete using recycled EPS aggregate are excellent. Especially, in the case of lightweight concrete under conditions of replacement ratio over 100%, it is considered that insulation performance is very excellent as thermal conductivity is showed about 0.2kcal/mh$^{\circ}C$. According to considering the relation between ultrasonic pulse velocity, unit weight and thermal conductivity through the graph, the result of relation between ultrasonic pulse velocity, unit weight and thermal conductivity on the graph expressed their high interaction shown as direct proportion on the graph. So that it is possible to extract the insulation performance of lightweight concrete using recycled EPS aggregate by ultrasonic pulse velocity and unit weight.

  • PDF

An Experimental Study on the Mechanical Properties of High Performance Lightweight Polymer Concrete (고성능 경량 폴리머 콘크리트의 역학적 특성에 관한 실험적 연구)

  • 성찬용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.3_4
    • /
    • pp.72-81
    • /
    • 1995
  • This study was performed to evaluate the mechanical properties of high performance lightweight polymer concrete using fillers and synthetic lightweight coarse aggregate. The following conclusions were drawn. 1. The unit weight of the G3, G4 and G5 concrete was 1.500t/m$^3$, 1.506t/m$^3$ and 1.535t/m$^3$, respectively. Specially, the unit weights of those concrete were decreased 33~35% than that of the normal cement concrete. 2. The highest strength was achieved by heavy calcium carbonate, it was increased 27% by compressive, 95% by tensile and 195% by bending strength than that of the normal cement concrete, respectively. 3. The elastic modulus was in the range of 8.0 x 104~ 10.4 x lO4kg/cm2, which was approximately 35~42% of that of the normal cement concrete. Normal cement concrete was showed relatively higher elastic modulus. 4. The ultrasonic pulse velocity of fillers was in the range of 2, 900m/sec, which was showed about the same compared to that of the normal cement concrete. Heavy calcium carbonate was showed higher pulse velocity. 5. The compressive, tensile, bending strength and ultrasonic pulse velocity were largely showed with the increase of unit weight.

  • PDF

The Experimental Study on Removal of Sulfur Dioxide and Nitrogen Oxide Using a Nano-Pulse Corona Discharger at Different Temperatures (나노펄스 코로나 방전의 온도 변화에 따른 이산화황 및 일산화질소 제거에 관한 실험적 연구)

  • Han, Bang-Woo;Kim, Hak-Joon;Kim, Yong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.4
    • /
    • pp.387-394
    • /
    • 2011
  • A study on the removal of sulfur dioxide and nitrogen oxide was carried out using a non-thermal nano-pulse corona discharger at different gas temperatures. Pulse voltage with a high voltage of 50 kV, a pulse rising time of about 100 ns, a full width at half maximum of about 500 ns and a frequency of 1 kHz was applied to a wire-cylinder corona reactor. Ammonia and propylene gases were added into the corona reactor as additives with a static mixer. Ammonia addition had less effect on $SO_2$ reduction at the higher temperature because of the retardation of ammonium sulfate formation. However, propylene addition enhanced NO reduction at higher temperature due to increased gas mixture. $SO_2$ was further removed at the mixed $SO_2$ and NO gas due to increased $NO_2$ by the conversion of NO. The addition of ammonia and propylene gases was more highly dominant for the removal of sulfur dioxide compared to the sole pulse corona without the additives. However, the specific energy density per unit concentration of pulse corona as well as propylene additive was an important factor to remove NO gas. Therefore, the specific energy density per unit concentration of 0.04 Wh/($m^3{\cdot}ppm$) was necessary for the NO removal of more than 80% with the concentration ratio of 2.0 for propylene and NO. Hydrogen peroxide was another alternative additive to remove both $SO_2$ and NO in the nano-pulse corona discharger.

Design of a High Stable Measuring Circuit for Radioactive Pulses (방사선 펄스의 고안정 계측회로 설계)

  • 송재용;한주섭;천상규;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.577-580
    • /
    • 2000
  • The aim of this paper is to develop a high stable measuring device for radioactive pulses. The device consists of a high voltage supply unit using a fly-back converter principle, and a pulse detection unit for gamma-rays and neutrons. The high voltage supply unit designed can generate DC voltage up to 1,500v at 5V-input, and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHz. From the experimental results, it is confirmed that the measuring device can count at least 10,000 pulses in a second.

  • PDF

Design and manufacture of mini loop coil magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료시스템의 설계 및 제작)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.153-155
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong.) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF