• Title/Summary/Keyword: unit load generation

Search Result 99, Processing Time 0.039 seconds

Operation Scheduling of Industrial Cogeneration System with Each other Generation Mode (서로다른 발전방식으로 운전되는 산업용 열병합발전시스템의 최적운전계획 수립)

  • Jeong, Ji-Hoon;Lee, Jong-Beom;Oh, Sung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.354-356
    • /
    • 2000
  • This paper describes the strategy of a daily optimal operational scheduling on cogeneration systems with each other generation mode. The cogeneration systems consists of three generators. auxiiiary devices which are three auxiliary boilers, two waste boilers and three sludge incinerators. One unit that using the back pressure turbin generates the electrical and the thermal energy. The other two units that using the extraction condensing turbine generate the energy. Auxiliary devices operate to supplement the thermal energy to the thermal load with three units. The cogeneration system has a large capacity which is able to supply enough the thermal energy to the thermal load, however the electric power generated is insufficient to satisfy the electrical load. Therefore the insufficient electric energy is supplemented by buying electrical energy from the utility. Simulation was carried out using optimization toolbox. The result reveals that the proposed modeling and strategy can be effectively applied to cogeneration systems with each other generation mode.

  • PDF

Remote On-line Determination of the Load Rate Limit of Generation in AGC (AGC 운용에 있어서의 원격 On-line 최대 증감발율 취득 기법)

  • Kwon, Soon-Man;Jeon, Dong-Hoon;Moon, Won-Yong;Kim, Suk-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.119-121
    • /
    • 2000
  • The possibility of a remote on-line determination of the maximum load rates that are basically set at generation plants is investigated in automatic generation control (AGC) system. Energy management system (EMS) generates a test input to a remote power plant to get the samples of the generator output. Then from the samples it can be attempted to determine an approximate value of the load rate limit set by the operator. It is shown in computer simulation that in actual power plants the limit can be approximately determined from the input-output characteristics of the plants for a unit-step input.

  • PDF

The Optimal Volt/Var Control Algorithm with Distributed Generation of Distribution System (분산전원이 연계된 배전계통의 최적 전압/무효전력 제어 알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.298-305
    • /
    • 2010
  • In this paper, a new algorithm of optimal Volt/Var Control is proposed using Volt/Var control for the Distribution Automation System (DAS) with Distributed Generation (DG) based on the modeling of the distributed load and the distributed current. In the proposed, algorithm based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU) and DG data from RTU for DG. For the optimal Volt/Var Control, the gradient method is applied to find optimal solution for tap, capacity and power control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), PC (Power Condenser) and DG (Distributed Generation). In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with DG using matlab program.

A Design of an Automotive Wheel Bearing Unit for Long Life (자동차 휠 베어링 유닛의 장수명 설계)

  • Yun, Gi-Chan;Choe, Dong-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.319-328
    • /
    • 2000
  • This paper presents a new design method of the 1 generation wheel bearing unit using a numerical optimization technique in order to increase bearing fatigue life. For calculating the fatigue life, a method of load analysis is studied on the automotive wheel bearing system. The design variables selected are ball size, initial contact angle, number of balls, pitch diameter, pre-load, and distance between ball centers. The method of feasible directions in ADS (Automated Design Synthesis) is utilized to automatically find the optimum design variables. To validate the design method, a computer program is developed and applied to a practical passenger car model. The optimum design results demonstrated the effectiveness of the proposed design method showing that the system life of the optimally designed wheel bearing unit is enhanced in comparison with that of the initial ones within the given available design space.

Neural Network Based Land Cover Classification Technique of Satellite Image for Pollutant Load Estimation (신경망 기반의 오염부하량 산정을 위한 위성영상 토지피복 분류기법)

  • Park, Sang-Young;Ha, Sung-Ryong
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.1-4
    • /
    • 2001
  • The classification performance of Artificial Neural Network (ANN) and RBF-NN was compared for Landsat TM image. The RBF-NN was validated for three unique landuse types (e.g. Mixed landuse area, Cultivated area, Urban area), different input band combinations and classification class. The bootstrap resampling technique was employed to estimate the confidence intervals and distribution for unit load, The pollutant generation was varied significantly according to the classification accuracy and percentile unit load applied. Especially in urban area, where mixed landuse is dominant, the difference of estimated pollutant load is largely varied.

  • PDF

Unbalanced Power Sharing for Islanded Droop-Controlled Microgrids

  • Jia, Yaoqin;Li, Daoyang;Chen, Zhen
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.234-243
    • /
    • 2019
  • Studying the control strategy of a microgrid under the load unbalanced state helps to improve the stability of the system. The magnitude of the power fluctuation, which occurs between the power supply and the load, is generated in a microgrid under the load unbalanced state is called negative sequence reactive power $Q^-$. Traditional power distribution methods such as P-f, Q-E droop control can only distribute power with positive sequence current information. However, they have no effect on $Q^-$ with negative sequence current information. In this paper, a stationary-frame control method for power sharing and voltage unbalance compensation in islanded microgrids is proposed. This method is based on the proper output impedance control of distributed generation unit (DG unit) interface converters. The control system of a DG unit mainly consists of an active-power-frequency and reactive-power-voltage droop controller, an output impedance controller, and voltage and current controllers. The proposed method allows for the sharing of imbalance current among the DG unit and it can compensate voltage unbalance at the same time. The design approach of the control system is discussed in detail. Simulation and experimental results are presented. These results demonstrate that the proposed method is effective in the compensation of voltage unbalance and the power distribution.

A Study on the Resetting of Incremental Heat Rate Curve of Combined Cycle Unit by Combination (복합발전기 조합별 증분비 곡선 재설정에 관한 연구)

  • Hong, Sang-Beom;Choi, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.8-12
    • /
    • 2019
  • Combined Cycle Unit(CC) generates the primary power from the Gas Turbine(GT) and supplies the remaining heat of the GT to the Steam Turbine(ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate(IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1:1~(N-1):1) using IHR curves when operating with GT alone(1:0) and with all(N:1) combinations of CC.

Optimization Algorithm for Real-time Load Dispatch Problem Using Shut-off and Swap Method (발전정지와 교환방법을 적용한 실시간급전문제 최적화 알고리즘)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.4
    • /
    • pp.219-224
    • /
    • 2017
  • In facing the lack of a deterministic algorithm for economic load dispatch optimization problem, only non-deterministic heuristic algorithms have been suggested. Worse still, there is a near deficiency of research devoted to real-time load dispatch optimization algorithm. In this paper, therefore, I devise a shut-off and swap algorithm to solve real-time load dispatch optimization problem. With this algorithm in place, generators with maximum cost-per-unit generation power are to be shut off. The proposed shut-off criteria use only quadratic function in power generation cost function without valve effect nonlinear absolute function. When applied to the most prevalent economic load dispatch benchmark data, the proposed algorithm is proven to largely reduce the power cost of known algorithms.

Evaluation of Boundary Conditions for Structural Analysis of Wheel Bearing Units (Wheel Bearing Unit의 구조해석을 위한 경계조건 설정에 관한 연구)

  • 김기훈;유영면;임종순;현준수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.230-237
    • /
    • 2000
  • The wheel bearing in vehicles has been improved to unit module by joining a bearing to a hub in order to achieve weight reduction and easy assembly. Currently, the contact force between a raceway and balls of a bearing is applied as the external force in order to analyse the structure of the unit type bearings. In this paper, simplified boundary conditions are discussed for structure analysis of wheel bearing unit. From the procedure, the contact conditions of balls and race in wheel bearing unit are considered as equivalent non-linear spring elements. The end node of a spring element is constrained in displacement. And the external force of boundary conditions is applied at the contact point between tire and road. For the evaluation of this analysis, its results for the force of spring elements are compared with contact forces of calculated results. and also maximum equivalent stresses of analysis are compared with results of test at the flange of inner ring. The analysis results with proposed boundary conditions are more accurate than results from analysis which is generally used.

  • PDF

A Study on the Power Generation Performance Evaluation of the Alternator for the Vehicle (자동차용 발전기의 발전 성능 평가에 관한 연구)

  • Ahn, Hyun-Jin;Shim, Kwan-Shik;Lim, Young-Cheol;Choi, Jun-Ho;Park, Sung-Jun;Kim, Eui-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.21-29
    • /
    • 2014
  • In this paper examine the characteristics of the generator supplying the most significant electrical energy in some parts required to drive the vehicle, and it is focused on to fabricate a performance evaluation unit for developing alternator with better performance. Through performance tests in accordance with the electrical load of alternators that is made in Valeo Corp. and Denso Corp., which are currently applied by H Corp., the fabricated performance evaluation unit has measured the power generation amount of the electrical energy supplied from the alternator, and it was analyzed. On the basis of this result, and to understand the flow of electrical energy of the vehicle, furthermore, it is intended to verify the usefulness of the performance evaluation unit which is designed in this paper. In this paper, based on the mechanism of the proposed performance evaluation unit, it will try to learn the convergence technology that can be applied to the design of the performance evaluation unit of other components of the vehicle.