• Title/Summary/Keyword: unit generation rate

Search Result 116, Processing Time 0.027 seconds

The Probabilistic Analysis on the Containment Failure by Hydrogen Burning at Severe Accidents in Nuclear Power Plants (원자력발전소 중대사고시 수소연소로 인한 격납용기 파손에 대한 확률적인 분석)

  • Park, I.K.;Moon, J.H.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.411-419
    • /
    • 1994
  • The containment failure probability due to hydrogen burning during severe accidents proceeding in a low pressure sequence is calculated using Monte Carlo method. The probability distribution functions for this Monte Carlo calculation is obtained from the statistical method. The calculations are performed for Kori unit 2, and the sensitivity studies on the input variables-the amount of hydrogen generated at SFD, cerium diameter, cerium length, oxidation rate at FCI, and the amount of hydrogen generated during MCCI-are also performed. It is revealed that SFD is the main factor in hydrogen generation, but the other sources also cannot be neglected. The containment failure probability due to the hydrogen burning lies within 6% in case of Kori unit 2.

  • PDF

Effect of Light-Induced ROS Generation Unit on Inactivation of Foodborne Pathogenic Bacteria in Water (광유도 ROS 발생장치의 세척용수 중 식중독 세균에 대한 불활성화 효과)

  • Choi, Jaehyuk;Kim, Dawoon;Jung, Kyu-Seok;Roh, Eunjung;Ryu, Kyoung-Yul;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.583-590
    • /
    • 2019
  • As the consumption of fresh fruits and vegetables increases, food poisoning caused by foodborne pathogen contamination is not decreasing. To prevent the contamination of produce, a quick and easy, low-cost, environmentally-safe disinfection method that does not affect produce freshness or quality is needed. This study demonstrates a new-concept, circulating-water disinfection system that purifies water by using newly developed 'LED-PS (photosensitizer)-induced ROS generation unit'. Using various types of LED-PS induced ROS generation units, we investigated the conditions for reducing the density of various pathogenic bacteria by more than 3 log CFU / mL in 1 hour. The major operational factors affecting the density reduction of the LED-PS-induced ROS generation unit were analyzed. Depending on bacteria species, the density reduction rate was varied. The effect of the units on reducing the density of Bacillus cereus and Pectobacterium carotovorum subsp. carotovorum was high, but the effect on foodborne bacteria such as Escherichia coli was relatively low. In this circulating water disinfection system, the density reduction effect tended to increase as the flow rate increased and the initial bacterial density decreased. As the amount of PS absorbed beads increased, the density reduction effect increased exponentially in some bacteria. Model 3280, a double cylindrical unit connecting two single cylindrical units, could completely sterilize more than 3 log CFU/mL of B. cereus and P. carotovorum subsp. carotovorum in 30 minutes of LED irradiation.

The Risk Assessment of Runway Reaction in the Process of Fridel-Crafts Acylation for Synthesis Reaction (화합물 합성반응 중 Fridel - Crafts Acylation 공정에서의 폭주반응 위험성평가)

  • Lee, Kwangho;Kim, Wonsung;Jun, Jinwoo;Joo, Youngjong;Park, Kyoshik
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.3
    • /
    • pp.24-30
    • /
    • 2021
  • Heat is generated during the synthesis and mixing process of chemical compounds due to a change in activation energy during the reaction. A runaway reaction occurs when sufficient heat is not removed during the heat control process within a reactor, rapidly increasing the temperature, reaction speed, and rate of heat generation inside the reactor. A risk assessment was executed using an RC-1 (Reaction Calorimeter) during Friedel-Crafts acylation. Friedel-Crafts acylation runs the risk of rapid heat generation during Active Pharmaceutical Ingredient (API) manufacturing; it was used to confirm the risk of a runaway reaction at each synthesis stage and during the mixing process. This study used experimental data to develop a safety efficiency improvement plan to control the risks of runaway and other exothermic reactions, which was implemented at the production site of a chemical plant.

Solar Cell Design for Large Area Multi Busbar Module Power Loss Reduction (대면적 Multi busbar 모듈 전력 손실 저감을 위한 태양전지 설계)

  • Juhwi Kim;Jaehyeong Lee
    • Current Photovoltaic Research
    • /
    • v.11 no.1
    • /
    • pp.34-37
    • /
    • 2023
  • Solar energy had become the main energy industry of renewable energy along with hydroelectric power generation. One of the technologies that contributed to the popularization of photovoltaic power and the decrease in the unit price of photovoltaic modules was the large-area solar cell. However, as the area increased, the light receiving area increased and the current value increased accordingly. Since power loss occurs when the current value was large, the number of busbar was increased to increase the current collection rate, and a technology to lower the current value through half-cutting was developed. The bus bar of the solar cell served as a passage through which the generated current was transmitted. This was because when the number of busbar decreases, the moving distance of electrons increased, so the amount of power generation decreases and when it increases, shadows occured. An important aspect of the electrode design was the optimal balance of these busbars and number of fingers. Therefore, in this study, the characteristics of the solar cell according to the number of front bus bars of the large-area solar cell were simulated using Griddler 2,5 pro. After selecting the number of busbar with the best characteristics, the difference was compared by varying the number of fingers and a better direction for the number of cutting was presented.

Dynamic Reserve Estimating Method with Consideration of Uncertainties in Supply and Demand (수요와 공급의 불확실성을 고려한 시간대별 순동예비력 산정 방안)

  • Kwon, Kyung-Bin;Park, Hyeon-Gon;Lyu, Jae-Kun;Kim, Yu-Chang;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1495-1504
    • /
    • 2013
  • Renewable energy integration and increased system complexities make system operator maintain supply and demand balance harder than before. To keep the grid frequency in a stable range, an appropriate spinning reserve margin should be procured with consideration of ever-changing system situation, such as demand, wind power output and generator failure. This paper propose a novel concept of dynamic reserve, which arrange different spinning reserve margin depending on time. To investigate the effectiveness of the proposed dynamic reserve, we developed a new short-term reliability criterion that estimates the probability of a spinning reserve shortage events, thus indicating grid frequency stability. Uncertainties of demand forecast error, wind generation forecast error and generator failure have been modeled in probabilistic terms, and the proposed spinning reserve has been applied to generation scheduling. This approach has been tested on the modified IEEE 118-bus system with a wind farm. The results show that the required spinning reserve margin changes depending on the system situation of demand, wind generation and generator failure. Moreover the proposed approach could be utilized even in case of system configuration change, such as wind generation extension.

Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System (중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석)

  • Kim, Kyu-Saeng;Lee, Sang-Hyeok;Hong, Kyung-Pyo;Won, Young-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

Development of a Wireless Engineering Tool for IMT-2000 System Based on WCDMA (WCDMA를 기반으로 한 IMT-2000시스템의 무선망 엔지니어링 툴의 개발)

  • 정회영;이인웅;조병헌;임재봉;오하령;성영락
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.201-204
    • /
    • 2000
  • In this paper, a wireless engineering field tool based on WCDMA is designed and implemented. Emerging requirements for higher rate data service and better spectrum efficiency are identified for the third generation mobile radio systems. The proposed WCDMA field tool is used for improving the quality of WCDMA service. The current position and time are measured and recorded with CDMA field data. With the system a user can observe the spatial distribution of the field data. For providing concurrency, the system is decomposed of four units and each unit is implemented by using threads.

  • PDF

Cryogenic Systems for HTS Power Cables

  • Yeom, Han-Kil;Koh, Deuk-Yong;Lee, Bong-Kyu;Kim, Ig-Seang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.133-135
    • /
    • 2003
  • Cryogenic systems are requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen at latm or sub-cooled LN2 above latm. HTS power cable needs sufficient refrigeration to overcome its low temperature heat loading. This loading typically cones in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper explains the cooling test system of 10m HTS power cable. This system is composed of storage dewar, auto fill system, core cryostat and cold-box. Storage dewar is a LN2 storage tank and auto fill system is a LN2 supply device to the sub-cooler, Core cryostat is a LN2 flow line. Cold box is a control unit of temperature and flow rate. It is composed of control valve, flow meter, sub-cooler and circulation pump, etc..

Analysis for the Coolability of the Reactor Cavity in a Korean 1000 MWe PWR Using MELCOR 1.8.3 Computer Code

  • Lee, Byung-Chul;Kim, Ju-Yeul;Chung, Chang-Hyun;Park, Soo-Yong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.669-674
    • /
    • 1996
  • The analysis for the coolability of the reactor cavity in typical Korean 1000 MWe Nuclear Unit under severe accidents is performed using MELCOR 1.8.3 code. The key parameters molten core-concrete interaction(MCCI) such as melt temperature, concrete ablation history and gas generation are investigated. Total twenty cases are selected according to ejected debris fraction and coolant mass, The ablation rate of concrete decreases as mass of the melt decreases and coolant mass increases. Heat loss from molten pool to coolant is comparable to total decay heat, so concrete ablation is delayed until water is absent and crust begins to remove. Also, overpressurization due to non-condensible gases generated during corium and concrete interacts can cause to additional risk of containment failure. It is concluded that flooded reactor cavity condition is very important to minimize the cavity ablation and pressure load by non-condensible gases on containment.

  • PDF

An Analysis of a Post-Trip Return-to-Power Steam Line break Events

  • Baek, Seung-Su;Lee, Cheol-Sin;Song, Jin-Ho;Lee, Sang-Yong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.544-549
    • /
    • 1995
  • An analysis for Steam Line Break (SLB) events which result in a return-to-power conditions after reactor trip was performed for a postulated Yonggwang Nuclear Power Plant Unit 3 cycle 8. Analysis methodology for post-trip return-to-power SLB is quite different from that of a no return-to-power SLB and is more complicated. Therefore, it is necessary to develop an methodology to analyze the response of the NSSS parameter and the fuel performance for the post-trip return-to-power SLB events. In this analysis, the cases with and without offsite power were simulated by crediting 3-D reactivity feedback effect due to local heatup around stuck CEA and compared with the cases without 3-D reactivity feedback with respect to fuel performance, departure from nucleate boiling ratio (DNBR) and linear heat generation rate (LHGR).

  • PDF