• Title/Summary/Keyword: unit control

Search Result 4,973, Processing Time 0.043 seconds

Architecture design and FPGA implementation of a system control unit for a multiprocessor chip (다중 프로세서 칩을 위한 시스템 제어 장치의 구조설계 및 FPGA 구현)

  • 박성모;정갑천
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.12
    • /
    • pp.9-19
    • /
    • 1997
  • This paper describes the design and FPGA implementation of a system control unit within a multiprocessor chip which can be used as a node processor ina massively parallel processing (MPP) caches, memory management units, a bus unit and a system control unit. Major functions of the system control unit are locking/unlocking of the shared variables of protected access, synchronization of instruction execution among four integer untis, control of interrupts, generation control of processor's status, etc. The system control unit was modeled in very high level using verilog HDL. Then, it was simulated and verified in an environment where trap handler and external interrupt controller were added. Functional blocks of the system control unit were changed into RTL(register transfer level) model and synthesized using xilinx FPGA cell library in synopsys tool. The synthesized system control unit was implemented by Xilinx FPGA chip (XC4025EPG299) after timing verification.

  • PDF

Study of improvement control logic about unit master control(UMC) (Unit master control(UMC) 제어로직 개선에 관한 연구)

  • Park, Doo-Yong;Lim, Gyun-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1707_1708
    • /
    • 2009
  • Unit master control(UMC)는 발전소의 요구 부하신호를 설정하는 최상위의 제어레벨이며 UMC의 설정값은 자동급전 지령신호(Automatic Dispatch System : ADS) 또는 운전원이 설정하는 값에 따라 보일러 및 터빈 Master에 Unit 요구 신호를 출력하여 하위제어 레벨인 공기, 연료, 급수 등을 조절할 수 있는 기기에 Unit 부하 요구 신호(Unit Load Demand : ULD)에 따라 제어 되도록 하는 방법으로서, Unit 목표부하 설정, Unit 목표부하 상/하한 제한, 목표부하 변화율 제한, 주파수 보정, Runback/Rundown/ Runup, 보일러 및 터빈 Demand 신호생성의 기능을 가지고 있다.

  • PDF

Development of a Tying-Unit Controller for a Variable Chamber Round Baler (가변 원형 베일러의 결속 기구 제어 장치 개발)

  • 김종언;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.341-350
    • /
    • 2000
  • This study was conducted to develop a control unit for a tying device of a variable chamber round baler. The work process of the tying device was thoroughly analyzed and the control sequence was established according to the work process. Based on this control sequence, a control unit using an 8 bit microprocessor AT 89C52 as a CPU was developed. The driving circuit to control the actuator motion was developed and the PWM method was used to regulate the velocity of the actuator. On the front panel of the control unit, indicators were also installed to show the operations being conducted. A prototype of the developed control unit was manufactured and tested. A total of 50 complete cycles of the control sequence was repeated and no failure was observed. It was evaluated that the developed control unit has an excellent performance and can be used practically for variable chamber round balers.

  • PDF

Design of FPGA in Power Control Unit for Control Rod Control System (원자로 제어봉 구동장치 제어시스템용 전력제어기 FPGA 설계)

  • Lee, Jong-Moo;Shin, Jong-Ryeol;Kim, Choon-Kyung;Park, Min-Kook;Kwon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.563-566
    • /
    • 2003
  • We have designed the power control unit which belongs to the power cabinet and controls the power supplied to Control Rod Drive Mechanism(CRDM) as a digital system based on Digital Signal Processor(DSP). The power control unit dualized as the form of Master/Slave has had its increased reality. The Central Process Unit(CPU) board of a power control unit possesses two Digital Signal Processors(DSPs) of the control DSP for performing the tasks of power control and system monitoring and the communication of the Control DSP and the Communication DSP. To accomplish the functions requested in the power control unit effectively, we have installed Field Programmable Gate Arrays(FPGAS) on the CPU board and have FPGAs perform the memory mapping, the generation of each chip selection signal, the giving and receiving of the signals between the power controllers dualized, the fault detection and the generation of the firing signals.

  • PDF

Study on Attitude Control System of Rotary Implement Attached on Agricultural Tractor (트랙터 로타리 작업기용 자세 제어 시스템에 관한 연구)

  • Lee, J.Y.;Go, W.;Shim, J.S.;Shin, H.C.
    • Journal of Biosystems Engineering
    • /
    • v.23 no.5
    • /
    • pp.427-438
    • /
    • 1998
  • In Korea, rotary implements are mainly utilized in the tillage operation. The attitude control system for rolling phenominon of tractors, which in caused due to uneven ground surfaces and sinkage of tractor wheels, is one of the most important control systems in agricultural tractors. The attitude control system of a rotary implement, attached on tractors, was designed and fabricated in this study. The control system was largely composed of four main units; a setting unit, a detection unit, a controller and a hydraulic unit. The implement was controlled by control signals from a computer proportional to controlled errors, on/off action of two directional solenoide valve and lift cylinder on the right lift rod. Response characteristic experiments for the control system fabricated in this study were carried out indoors and outdoors. The results of experiments showed the response characteristics sufficient to use as the attitude control system of rotary implements for agricultural tractors.

  • PDF

Development of Automatic Digital/Analog Lighting Control System using ATMega 128 (ATMega128을 이용한 디지털/아날로그 자동조명제어장치의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.161-166
    • /
    • 2006
  • In this paper, an automatic lighting control system is developed using microprocessor. The developed system consists of a digital lighting control unit, an analog lighting control unit, and a lighting control simulator. In the developed system, ATMega128 is used as the main controller. The developed digital lighting control unit consists of eight modules and the developed analog lighting control unit consists of six modules respectively. Additional, the developed simulator consists of a digital and an analog lighting control simulation using graphic user interface. And so this developed system can be applied to the controller design of the interior and exterior lighting equipment.

Design and Implementation of a Digital Control Unit for an Oxygenaire Servo Baby Incubator

  • Zahran, Mohamed;Salem, Mahmoud;Attia, Yousry;Eliwa, Aref
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.121-130
    • /
    • 2008
  • This paper introduces a design and implementation of a digital control unit for an Oxygenaire Servo Baby Incubator. The control unit is designed and implemented according to international standards. The control unit is based on an AVR Atmel microcontroller unit. It is built for monitoring and control and displays the three main temperature values: set point temperature, baby skin temperature and air temperature. User friendly software is implemented. The implemented control unit was tested in the laboratory as well as in the field. The control unit is sensitive to change of $0.1^{\circ}C$. At startup, based on a unique control strategy, the incubator reaches its steady state in about 14 minutes. The system schematic diagrams are shown in the paper. Also, programs flow charts are presented. The control unit was designed and implemented based on a contract between the Electronics Research Institute (ERI) and ENGIMED Company. The authors would like to thank ERI and ENGIMED for introducing all required finance and shoring to complete this work.

The Development of Hemodialysis System Based on Embedded System (임베디드 시스템 기반의 혈액 투석기 시스템의 개발)

  • Ji, Jung-Ho;Lee, Kyoung-Joung;Kim, Young-Ho;Park, Kwang-Li
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.11
    • /
    • pp.521-527
    • /
    • 2002
  • The Hemodialysis system is the device for the patients who have suffered from end stage renal failure as the kidney which removes the waste products in a human body. The existing hemodialysis is based on a 8-bit micro-controller and it is not a touch-screen type but a manual type. This paper is focused on hemodialysis system based on high control and expension embedded system. The whole system consists of main control unit and sub control unit(dialysis control unit, blood control unit, monitoring control unit, networking unit). The dialysis control unit, blood control unit, monitoring control unit are processed by 3 microcontrollers and network unit is for monitoring a renal failure patient's condition. For the evaluation of the system performance, the saline was pured into blood unit and then water removal rate, conductivity and temperature of hemodialysis liquid were measured 10 times in an each state suing the UF pump in the fluid unit varing the quantity of saline to 1000cc, 2000cc, 3000cc and 4000cc. As a result, the rates of water removal are 98.6% in condition of 000cc saline, 96.9% in 2000cc, 98.9% in 3000cc and 98.3% in 4000cc. The conductivities of hemodialysis liquid are 99.6% in the first to third condition and 99.7% in the forth condition. The temperatures of hemodialysis liquid are 99.8% in the first to third condition and 99.6% in th forth condition.

Integration Development of Marine Surveillance System (해상 감시시스템의 통합 개발)

  • Park, Gil-Soo;Lee, Won-Bu;Park, Soo-Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.699-701
    • /
    • 2010
  • For the development of surveillance Multi Sensor and IFOG, development of integrated surveillance camera for day and night time of its system Control Unit design and navigation device interlocking system was made. Control Unit analysis of integrated ship system began with selection of control unit related to feasible navigation device list.After sorting navigation equipment list, applications, features, connection methods, communication methods, data type of control unit and data direction between navigation equipments and the data types of each navigation equipment is sorted to observe its performance.

  • PDF

An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer (컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구)

  • Cho, Jin Ho;Lee, Dae Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF