• Title/Summary/Keyword: uniformity test

Search Result 365, Processing Time 0.038 seconds

LDV Measurement, Flow Visualization and Numerical Analysis of Flow Distribution in a Close-Coupled Catalytic Converter

  • Kim, Duk-Sang;Cho, Yong-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.2032-2041
    • /
    • 2004
  • Results from an experimental study of flow distribution in a close-coupled catalytic converter(CCC) are presented. The experiments were carried out with a flow measurement system specially designed for this study under steady and transient flow conditions. A pitot tube was a tool for measuring flow distribution at the exit of the first monolith. The flow distribution of the CCC was also measured by LDV system and flow visualization. Results from numerical analysis are also presented. Experimental results showed that the flow uniformity index decreases as flow Reynolds number increases. In steady flow conditions, the flow through each exhaust pipe made some flow concentrations on a specific region of the CCC inlet. The transient test results showed that the flow through each exhaust pipe in the engine firing order, interacted with each other to ensure that the flow distribution was uniform. The results of numerical analysis were qualitatively accepted with experimental results. They supported and helped explain the flow in the entry region of CCC.

The effect of chemical kinetics of slurry components on Cu CMP (화학반응속도가 Cu CMP에 미치는 영향)

  • Jung, Won-Duck;Chang, One-Moon;Park, Sung-Min;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.372-373
    • /
    • 2006
  • Chemical kinetics affects Cu CMP results (removal rate, Non uniformity etc.) Because Cu is removed by chemical action. Key factors in chemical kinetics are process temperature and concentration of slurry components. In this study, Hydrogen peroxide and citric acid were selected as a oxidant and a complexing agent and Slurry were made by mixing this components. In order to study effects of Chemical Kinetics, X-ray photoelectron spectroscopy (XPS) were performed on Cu sample after etching test as concentration of citric acid and slurry temperature. Finally Cu CMP was performed as same conditions.

  • PDF

Fabrication of CNT Electron Source for Field Emission Displays

  • Nakata, S.;Sawada, T.;Fujikawa, M.;Nishimura, K.;Abe, F.;Hosono, A.;Watanabe, S.;Yamamuro, T.;Shen, Z.;Suzuki, Y.;Okuda, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1012-1015
    • /
    • 2005
  • We have developed the technique of fabricating triode structure with simple stacking method using a polymer insulator that is suitable for large panel and the activation method after the fabrication. By the techniques, a test panel was manufactured and proves good emission property and uniformity.

  • PDF

Control of Shock Wave/Boundary-Layer Interactions Using S-Shaped Mesoflaps (S-자형 플랩을 이용한 충격파와 경계층 간섭현상 제어에 관한 연구)

  • Lee Yeol
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.159-160
    • /
    • 2002
  • New S-shaped aeroelastic mesoflaps are utilized to control normal shock/boundary-layer interactions. New generation of the mesoflaps is designed f3r a better rigidness and a good flow uniformity across the ulteractions. ,Major advantages of the mesoflap system can be a better total pressure recovery downstream of the interactions due to the lambda shock structure over the flap system, and a rehabilitation of the thickened boundary layer due to bleeding through a cavity underneath the flap system. Skin friction has been measured downstream of the interactions, using the laser interferometer skin friction (LISF) meter, which optically detects the rate of thinning of an oil film applied to the test surface. Various flap-thicknesses of the S-shaped mesoflap arrays are tested, and the results are compared to the solid-wall reference case. Overall, not much difference in the level of skin friction is noticed for the S-shaped flap arrays of various thicknesses, and its level is lower than the skin friction downstream of the solid-wall interaction

  • PDF

The comparison between experimental and FEA results for crack initiation due to corrosion of reinforcement (콘크리트 구조물의 철근부식으로 인한 균열발생에 관한 실험적, 해석적 결과의 비교)

  • 장상엽;김용철;조용범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.693-698
    • /
    • 2003
  • Corrosion of reinforcement and deterioration of concrete short the lifetime of reinforced concrete structure and affect the safety of the structure. In particular, the corrosion of reinforcement causing the inner pressure of the interface between the concrete and reinforcement is known to significantly contribute to the premature deterioration of concrete structure. Several attempts have been made to predict the cracking time of the concrete structure. However, problems such as the lack of reproducibility of concrete tests and non-uniformity of materials have hampered thess kinds of studies. Thus, the mechanism of the concrete cracking due to reinforcement corrosion is in the way. This studymeasured the mechanical properties of corrosion products using the nano-indentation test method. Likewise, the critical thickness of corrosion products for the cracking of concrete cover was investigated using the finite element and experimental methods.

  • PDF

Tip-less PDP Vacuum In-Line Sealing Technology by Bubble-Reduced Frit along an Auxiliary Heating Line

  • Kwon, Sang-Jik;Yang, Hwi-Chan;Lee, Myung-Sik;Whang, Ki-Woong;Jung, Dong-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.643-646
    • /
    • 2002
  • Sealing of two glass plates composing of PDP panel was done in a vacuum chamber by using an auxiliary heating line(AHL). In order to improve the uniformity of sealing temperature and reduce the panel temperature during sealing, the AHL was introduced by a screen printing method inside a frit glass and used as a part of heating source for the frit melting. By using the AHL technology and the specially prepared frit glass, we have successfully sealed a PDP test panel without bubbles and any leak through the frit glass.

  • PDF

Characterization of Probe Pin for LED Inspection System (LED 검사장비용 탐침의 특성 규명)

  • Shim, Hee-Soo;Kim, Sun Kyoung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.647-652
    • /
    • 2015
  • A probe pin is a key component of LED inspection equipment. The probe pin makes contact with the LED electrodes and supplies an electric current. Because the mechanical and electrical homogeneity of the probe surface affects the service life and reliability, its characterization is essential. For this study, the hardness was measured using a micro-Vickers hardness test. Moreover, the thicknesses of the plating at different locations and the elemental compositions were examined using an FE-SEM. The uniformity of the plating was found to be acceptable because palladium was detected consistently throughout the tested domain. In addition, the hardness of the surface was determined to be higher than that of the typical palladium range, which is attributed to the use of undercoated nickel.

The development of a variable capacitive pressure sensor for TPMS(tire pressure monitoring system) (TPMS 적용을 위한 가변 정전 용량형 압력센서 개발)

  • Choi, Bum-Koo;Kim, Do-Hyung;Oh, Jae-Geun
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.265-271
    • /
    • 2005
  • In this study, a variable capacitive pressure sensor is fabricated for TPMS (Tire Pressure Monitoring System). This study is for developing sensors which consecutively measure the tire pressure given as 30 psi from the industrial standard. For improving non-linearity of the prior capacitive pressure sensors, it is suggested that touch mode capacitive pressure sensor be applied. In addition, initial capacitance is designed as small as possible for the conformity to the wireless sensor. ANSYS, commercial FEA package, is used for designing and simulating the sensor. The device is progressed by MEMS (Micro Electro Mechanical Systems) fabrication and packaged with PDMS. The result is obtained sensitivity, 1 pF/psi, through a pressure test. The simulation result is discrepant from experiment one. Wafer's uniformity is presumed as the main reason of discrepancy.

Studies on Optimum Conditions for Experimental Procedure of Yukwa (II) -On the additives and drying methods- (유과조리법의 표준화에 관한 연구(II) -첨가물과 건조 방법을 중심으로-)

  • Jeon, Hyeong-Ju;Sohn, Kyung-Hee
    • Journal of the Korean Society of Food Culture
    • /
    • v.10 no.2
    • /
    • pp.83-88
    • /
    • 1995
  • This study was conducted to examine the effects of additives and drying methods in Yukwa's manufacture. Additives had significant effects on hardness, and bean water and bean powder added group rated better than the baking powder and boiled bean added group. Sensory evaluation test showed that bean water and bean powder added group produced higher desirability. Drying methods had significant effects on all attribute of sensory evaluation, natural drying and incubative plate drying produced higher uniformity, denseness and overall desirability.

  • PDF

Modeling and Prediction of Yarn Density Profiles Using Neural Networks (인공 신경망을 이용한 방적사 굵기 신호의 모델링)

  • Kim, Joo-Yong
    • Textile Coloration and Finishing
    • /
    • v.19 no.6
    • /
    • pp.7-11
    • /
    • 2007
  • A prediction model for yarn density profile was developed using the neural network methodology. The neural network model developed traces mass densities of a yarn within a section and predicts the mass profiles of the next yarn segment yet to be measured. The model does not require an assumption on the existence of a relationship between the past and future data sets. Four high-draft yarns made under different processing conditions were employed in order to test the performance of the model developed. It was shown that the model could predict the yarn density profiles without a significant error.