• Title/Summary/Keyword: uniformity test

Search Result 365, Processing Time 0.03 seconds

Estimation of Flow Uniformity in Water Tunnel by Using CFD Analysis (전산유동 해석을 이용한 수동의 유동 균질성 평가)

  • Lim, Y.T.;Chang, J.W.;Kim, M.S.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.12 no.3
    • /
    • pp.13-24
    • /
    • 2004
  • It is easier to view flow visualization by using a water tunnel rather than a smoke wind tunnel because of low speed at same Reynolds number. Using a water tunnel also produces more definite flow visualization by the use of various color dyes. The flow uniformity in test section is very significant for accuracy of the test because most flow experiments elicit results through the installation of a model in uniform flow. The purpose of small-size desktop-type water tunnel is not to produce quantitative measurements, but rather to give a visualization of the fluid flow phenomenon. However, uniformity in the test section affects the accuracy of the results. Accordingly, this research estimates uniformity in a water tunnel test section by using the commercially available CFD code FLUENT. Results of the CFD analysis show that the flow uniformity of the test section is good.

  • PDF

A Psychophysical Approach to evaluating the perceived image quality of CRT: White Uniformity Quality (CRT 모니터의 감성품질 정량화를 위한 심물리학적 접근: White Uniformity 품질 평가)

  • Lee, Uk-Gi;Kim, Seong-Hwan;Lee, Seon-Gyu;Lee, Gwang-Hui;Kim, Sang-Su
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.59-70
    • /
    • 2001
  • White uniformity is one of the important inspection factors determining the image quality of CRT screen. In the full white pattern, white uniformity means the degree of uniform distribution of white color across the whole screen. To elicit the sensitivity factors affecting the decision of the white uniformity quality, experiments in which participants were confronted with 6 evaluation points embedded in 3 measurement groups on a CRT screen were conducted to gather the psychophysical data that are the level of white uniformity subjects perceived and CA100 produced. These data were used to develop a modified CIE1976 equation for calculating white uniformity. Performance comparison between the original CIE1976 equation and the modified equation was conducted in terms of accuracy test and magnitude estimation. It was concluded the modified equation is more sensitive in the change of white uniformity, compared to the original CIE1976 equation.

  • PDF

A Study on the Evaluation Method of Field Uniformity(FU) for Radiated Immunity Test of Vehicle Component (차량용 전장품의 복사내성 평가를 위한 균일장 측정방법에 대한 연구)

  • Yoon, Jae Sang;Hong, Hyun Gwi;Kam, Dong Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.633-636
    • /
    • 2017
  • This thesis is about the evaluation method of field uniformity for radiated immunity test of vehicle component. Radiated immunity test is to find out whether a EUT has enough immunity or hold normal operation during applied electromagnetic interference. Field Uniformity(FU) measurement is essential for generate uniform field on DUT and Harness. But Standard of Radiated Immunity(RI) test for vehicle component based on ISO 11452-2 has not been specified a Field Uniformity(FU). So compared and analyzed with other standard which is defined by a specified a Field Uniformity. As a result, deviation occurs in the difference test condition and test method. In this thesis, proposal new measurement method of field uniformity that is considered test conditions of ISO 11452-2 and check the validity through actual test.

  • PDF

Mode-Stirred Reverberation Chamber Characteristic to Stirrer Parameter and Usefulness Evaluation (교반기 매개변수에 따른 교반형 전자파 잔향실의 특성 및 유용성 평가)

  • Kim, Kwang-Yong;Hong, Joo-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1652-1657
    • /
    • 2010
  • This paper analyzes optimal stirrer parameter to improve field uniformity in a mode-stirred reverberation chamber. Stirrer parameter is varied about stirrer height and stirrer angle. Also we analyze quality factor, number of excited modes and stirrer efficiency that affect field uniformity. The results show good performance as higher as stirrer height. Isotropic field distribution is formed at $45^{\circ}$ stirrer angle. When stirrer angle varies, scattering characteristic of incident wave are changed. So electric field distribution in a mode-stirred reverberation chamber is also changed. Therefore, it affect field uniformity. The results expect to help that designs stirrer for get better field uniformity. Immunity test performed designed mode-stirred reverberation chamber for semiconductor that categorized by technology. Test result shows that good recurrence compared wave-guide immunity test.

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

Numerical Study to Improve the Flow Uniformity of Blow-Down HVAC Duct System for a Train (전동차용 Blow-Down HVAC 덕트 시스템의 유동 균일도 향상을 위한 수치적 연구)

  • Kim, Joon-Hyung;Rho, Joo-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.18-23
    • /
    • 2016
  • A HVAC(Heating Ventilation and Air Conditioning) is adapted to increase the comfort of the cabin environment for train. The train HVAC duct system has very long duct and many outlets due to the shape of a train set. the duct cross section shape is limited by a roof structure and equipments. Therefore, the pressure distribution and flow uniformity is an important performance indicator for the duct system. In this study, the existing blow down type HVAC duct system for a train was supplemented to improve the flow uniformity by applying a design method combining design of experiment (DOE) with numerical analysis. The design variables and the test sets were selected and the performance for each test set was evaluated using CFD(Computational Fluid Dynamics). The influence of each design variable on the system performance was analysed based on the results of the performance evaluation on the test sets. Furthermore, the optimized model, whose the flow uniformity was improved was produced using the direct optimization(gradient-based method). Finally, the performance of the optimized model was evaluated using numerical analysis, and it was confirmed that its flow uniformity has indeed improved.

A Numerical Study on the Flow Uniformity according to Chamber Shapes Used for Test of the Semi-Conductor Chip (반도체 칩 테스트용 챔버 형상에 따른 유동 균일성에 대한 수치적 연구)

  • LEE, DAEGYU;MA, SANG-BUM;KIM, SUNG;KIM, JEONG-YEOL;KANG, CHAEDONG;KIM, JIN-HYUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.480-488
    • /
    • 2020
  • This study was conducted to improve the flow uniformity inside the chip tester through changing the flow path formation according to the inlet and outlet position of chamber. The internal flow and velocity distributions of the modified chamber models (Cases 1-3) were compared with the reference chamber model through three-dimensional Reynolds-averaged Navier-Stokes equations with k-ε turbulence model. The modified chamber models showed the superior flow uniformity characteristics compared to the reference chamber model. To investigate the flow uniformity in the chip tester, the standard deviation of the velocity was defined and compared. Through the internal flow analysis and assesment of the standard deviation, Case 2 among the test cases including the reference model showed the best flow uniformity generally.

A Study on the Characteristics of Air flow Fields with Velocity Uniformity in a Wind Tunnel (풍동장치 내 공기 유동장과 속도 균일도 특성에 대한 분석)

  • Han, Seok Jong;Lee, Sang Ho;Lee, Jae Gyu
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.3
    • /
    • pp.59-64
    • /
    • 2018
  • Numerical simulations were carried out to analyze the flow characteristics of the wind tunnel. Flow field characteristics with velocity uniformity at the test sections are largely affected by inlet conditions of air flow rate and temperature. Axial average velocity of the flow field inside the test area was almost linearly decreased by 0.026% each 1m. The uniformity distributions of axial velocity showed the highest reduction rate of about 24% between nozzle outlets 1 ~ 2m. In addition, average velocity and the uniformity are increased with air temperature in the wind tunnel due to density variation. The results of this paper are expected to be useful for the basic design of wind tunnel and to be used for efficient design.

Control of Uniformity in the Drug Industry By focusing on solid dosage forms for internal use

  • Lee, Seung-Woo
    • Proceedings of the PSK Conference
    • /
    • 2003.10a
    • /
    • pp.40-41
    • /
    • 2003
  • The present topic in pharmaceutical industry is to establish Quality Assurance System for medicinal product Therefore, the most important and urgent subject to be solved in the field of the manufacturing industry is to establish, implement and maintain the control system for ensuring uniformity of medicinal product. In case of solid dosage forms for internal use, its quality was controlled by disintegration test, etc but at present bioavailability could be predicted with dissolution test and so the assurance of its uniformity should be prerequistie to preserve suitable dissolution of the manufactured medicinal product. (omitted)

  • PDF

Study on the Aerodynamic Characteristics of Hanyang Low Speed Wind Tunnel (한양대학교 중형 아음속 풍동의 공력특성에 관한 연구)

  • Go, Gwang Cheol;Jeong, Hyeon Seong;Kim, Dong Hwa;Jo, Jin Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.92-98
    • /
    • 2003
  • The optimum design of Hanyang low speed wind tunnel has been performed to augment flow uniformity and to reduce turbulence intensity of wind tunnel test section have to be known for reliability of wind tunnel test. The non-uniformity and turbulence intensity of Hanyang low speed wind tunnel were measured with Pilot tube and X-type hot-wire probe at various wind speeds. As the results, the non-uniformity decreases as the wind speed increases. The non-uniformity is relatively high in the proximity of the diffuser. The turbulence intensity is a little higher than design requirement in the middle of the test section.