• 제목/요약/키워드: uniform model

검색결과 1,750건 처리시간 0.027초

횡성호 수질모의를 위한 QUAL2E 모형의 적용 (Application of QUAL2E Model for Water Quality Simulation of Hoengseong Lake)

  • 김상호
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.651-660
    • /
    • 2009
  • Detailed flow analysis in river is essential to increase the accuracy of water quality simulation since flow variation depends on many factors such as cross sections, channel slopes, and bed materials. In the QUAL2E stream water quality simulation model, the hydraulic coefficients are assigned to the reach that is collection of computational element using the hydraulic coefficient. This study developed a module that can incorporate the results of non-uniform flow analysis and assign such information to each individual element. Model application focused on the upstream of the Hoengseong reservoir including the reservoir where significant flow change is expected. Comparing with original QUAL2E model the developed module improved the result of water quality simulation without considering the relation of flow velocity and flow depth in terms of flow rates.

A two-dimensional hyperbolic spring model for mat foundation in clays subjected to vertical load

  • Der-Wen Chang;Tzu-Min Chou;Shih-Hao Cheng;Louis Ge
    • Geomechanics and Engineering
    • /
    • 제37권5호
    • /
    • pp.527-538
    • /
    • 2024
  • This study proposes a two-dimensional hyperbolic soil spring model for mat foundations in clays subjected to vertically uniform loads to simplify the complexity of three-dimensional finite element analysis on mat foundations. The solutions from three-dimensional finite element analysis were examined to determine the hyperbolic model parameters of the soil springs underneath the slab. Utilizing these model parameters, normalized functions across the middle section of the mat were obtained. The solutions from the proposed model, along with the approximate finite difference analysis of the mat in clays under vertical load, were found to be consistent with those from the three-dimensional finite element analysis. The authors conclude that the proposed method can serve as an alternative for the preliminary design of mat foundations.

Prediction of Air Movement and Temperature Distribution at Different Store Methods Using 3-D CFD Simulation in Forced-Air Cooling Facility

  • Yang, G.M.;Koh, H.K.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.65-72
    • /
    • 2002
  • Temperature is the most influential environment parameter which affects the quality change of agricultural products in cold storage. Therefore, it is essential to keep the uniform temperature distribution in the storage room. This study was performed to analyze the air movement and temperature distribution in the forced recirculating cold storage facility and to simulate optimum storage method of green groceries using 3-D CFD(three dimensional computational fluid dynamics) computer simulation which applied the standard $textsc{k}$-$\varepsilon$ turbulence model and FVM(finite volume method). The simulation was validated by the experimental results for onion storage and the simulation model was used to simulate the temperature and velocity distribution in the storage room with reference to the change of storage method such as location of storage, no stores, bulk storage, and pallet storage. In case of no stores, internal airflow was circulated without stagnation and consequently air movement and temperature distribution were uniform. In case of bulk storage, air movement was stagnated so much and temperature distribution of onion was not uniform. Furthermore, the inner temperature of onion roses more than the initial temperature of storage. In case of pallet storage, air movement and temperature distribution of onion were so uniform that the danger of quality change was decreased.

  • PDF

초정밀 가열판의 온도 균질화를 위한 새로운 설계방법 (New Design Approach for the Uniform Temperature of Precision Hot Plates)

  • 박용환
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1525-1533
    • /
    • 2003
  • In the precision hot plate for wafer processing, uniform temperature of the upper plate is one of key factors affecting the quality of wafers. The state-of-the-art precision hot plates require temperature Variations less than $\pm$0.4$^{\circ}C$ during heating to 15$0^{\circ}C$, Which is difficult to be obtained only by the improvement of manufacturing techniques alone. In this study, computer aided heat transfer analysis was carried out to obtain the temperature distribution of the currently used reference hot plate for 200mm wafer. The analysis on the reference model assuming constant heat generation rate and uniform heating area showed total variation of 0.926$^{\circ}C$ at 15$0^{\circ}C$. One of the new design approaches based on the change of heating location together with different heat generation rate resulted in total variation of 0.297$^{\circ}C$ which is a 68% improvement compared to that of the reference model.

건축설계의 협동작업을 지원하는 지능형 CAD 엔진의 개발 (A Development of an Intelligent CAD Engine to Support Architectural Design Collaboration)

  • 최진원
    • 한국CDE학회논문집
    • /
    • 제2권1호
    • /
    • pp.53-59
    • /
    • 1997
  • Current CAD systems used in the AEC community have some critical problems. One of them is that they hardly support design collaboration. Thus designers and engineers are hard to transfer design knowledge from one discipline to another. What we need is a common building database which creates and manages building plans/models and relevant design knowledge consistently and effectively. This paper presents a powerful CAD editor, called UNIFORM, which is being developed. Currently UNIFORM includes three main modules: a plan generator, a 3-D model generator, and component databases. A plan generator, called UNIFORM PLANNER, creates a plan which contains semantically-rich information of building. Each component in the plan can be presented in various ways and connected to component databases that contain knowledge of building components such as windows, doors, walls, etc. Based on the plan UNIFORM MODELER, another module of the program, generates a three dimensional building model which could be a multiple-story building. One of the main ideas behind the system is that it generates and maintains a common building form that can be easily delivered to other members of the project team. Thus it is expected to increase system integration, team interactions, and productivity.

  • PDF

인발 봉재의 반경방향 불균일 변형률 평가 (Evaluation of Radial Direction Non-uniform Strain in Drawn Bar)

  • 이성민;이인규;이성윤;정명식;문영훈;이상곤
    • 소성∙가공
    • /
    • 제29권6호
    • /
    • pp.356-361
    • /
    • 2020
  • In general, the drawing process is performed in a multi-pass to meet the required shape and cross section. In the drawn material, the surface strain is relatively higher than the center due to the direct contact with the die. Therefore, a non-uniform strain distribution appears in the surface of the material where the strain is concentrated and the center having a relatively low strain, thus it is difficult to predict the strain in the drawn material. In this study, the non-uniform strain distribution was evaluated using a finite element analysis and the non-uniform strain distribution model based on the upper bound method. In addition, the relationship between the hardness and the strain was established through a simple compression test to evaluate the distribution of the strain in the experimentally multi-pass drawn bar.

주행질량에 의한 불균일 단면보의 동적응답 (Dynamic Response of Non-uniform Beams under a Travelling Mass)

  • 김인우;이영신;이규섭;류봉조
    • 한국소음진동공학회논문집
    • /
    • 제11권5호
    • /
    • pp.140-147
    • /
    • 2001
  • In this paper, the dynamic response of non-uniform beams subjected to a travelling mass is investigated. Dynamic behaviors of flexible beam structures under a moving mass have been a concern in the design of bridges, ceiling crain in industry, as well as gun barrel fields. Most of studies for moving mass problems have been related to the theoretical dynamic responses of a simple beam model with uniform cross-sections. In some experimental studies, only a few transverse inertia effects due to travelling mass have been studied so far. The intended aim of the present Paper is to investigate the dynamic response of non-uniform beams taking into account of inertia force. centrifugal force, Coriollis force and self weight due to travelling mass. Galerkin's mode summation method is applied for the discretized equations of motion. Numerical results for the dynamic response of non-uniform beams under a travelling mass are demonstrated for various magnitudes and velocities of the travelling mass. In order to verify propriety of numerical solutions, experiments were conducted. Experimental resu1ts have a good agreement wish theoretical Predictions.

  • PDF

불균일 농도가 가스 폭발에 미치는 영향 (Effect of Non-uniform Concentration on Gas Explosion)

  • 김상섭;장기현
    • 한국가스학회지
    • /
    • 제7권4호
    • /
    • pp.14-19
    • /
    • 2003
  • 일반적으로 발생하는 사고중의 가스폭발사고는 일정한 상태로의 혼합과정보다는 불균일하게 이루어진 상태로 폭발이 발생하고 있다. 본 연구에서는 불균일 상태에서의 불균일 농도에 의한 폭발현상을 실제 실내의 축소형으로 폭발통을 제작, 모형화하여 여러현상을 재현함으로서 실제 사고시의 폭발현상을 예측할 수 있었다. 그 결과, 어떤 공간에서 가스가 누출될 경우 내부의 가스의 혼합정도는 누출구의 크기 및 누출속도에 따라 영향을 받으며, 불균일 정도가 클수록 폭발압력 및 압력상승속도는 낮아지고 폭발압력은 감소하지만 화염의 체류시간이 증가하여 폭발화염의 복사열에 의한 폭발 후에는 화재의 위험성이 증가함을 알 수 있었다.

  • PDF

Component fragility assessment of a long, curved multi-frame bridge: Uniform excitation versus spatially correlated ground motions

  • Jeon, Jong-Su;Shafieezadeh, Abdollah;DesRoches, Reginald
    • Structural Engineering and Mechanics
    • /
    • 제65권5호
    • /
    • pp.633-644
    • /
    • 2018
  • This paper presents the results of an assessment of the seismic fragility of a long, curved multi-frame bridge under multi-support earthquake excitations. To achieve this aim, the numerical model of columns retrofitted with elliptical steel jackets was developed and validated using existing experimental results. A detailed nonlinear numerical model of the bridge that can capture the inelastic response of various components was then created. Using nonlinear time-history analyses for a set of stochastically generated spatially variable ground motions, component demands were derived and then convolved with new capacity-based limit state models to obtain seismic fragility curves. The comparison of failure probabilities obtained from uniform and multi-support excitation analyses revealed that the consideration of spatial variability significantly reduced the median value of fragility curves for most components except for the abutments. This observation indicates that the assumption of uniform motions may considerably underestimate seismic demands. Moreover, the spatial correlation of ground motions resulted in reduced dispersion of demand models that consequently decreased the dispersion of fragility curves for all components. Therefore, the spatial variability of ground motions needs to be considered for reliable assessment of the seismic performance of long multi-frame bridge structures.

R410A 냉방시스템의 마이크로채널 응축기에 관한 연구 (A Study on a Microchannel Condenser in a R410A A/C System)

  • 박창용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.221-226
    • /
    • 2008
  • A microchannel condenser as a part of a R410A residential air-conditioning system was examined experimentally and numerically in this study. The system was operated in separate environmental chambers and its performance was measured in ARI A, B, and C conditions. A numerical model for the microchannel condenser was developed and its results were compared with the experimental results. The model simulated the condenser with the assumption of the uniform air and refrigerant distribution, and with the consideration of the non-uniform air distribution at the face of the condenser and refrigerant distribution in the headers. In order to consider the non-uniform air distribution, air velocity contours were generated from the measured local air velocities at the face of the condenser. The simulation results showed that the effect of the air and refrigerant distribution was not a significant parameter in predicting the capacity of the microchannel condenser which was experimentally examined in this study. The comparison of the calculated and experimental results showed that the condenser capacity could be predicted well for every test condition. However, the prediction of refrigerant pressure drop deviated significantly from the measured values.

  • PDF