• 제목/요약/키워드: underground transmission

Search Result 387, Processing Time 0.029 seconds

Building Underground Facility Management System of Power Transmission and Power Distribution using GIS (지리정보체계를 이용한 송배전 지하시설물관리시스템 구축)

  • Jang, Yong-Gu;Kang, In-Joon;Kim, Sang-Seok;Yang, Seung-Tae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.2
    • /
    • pp.69-77
    • /
    • 2004
  • Now, there are some problems to manage underground facilities in domestic. Specially, in the case of KEPCO(Korea Electric Power Corporation), it is so difficult to manage electronic line more stably and detailedly because the geographic information and attribute information being built is not easy to be updated in the field. KEPCO officials who are accompanying management and supervision in earthwork do not have sufficient knowledge and information about GIS but they grasp the information of geography and property which coincide with the field. Therefore they have to refer their business analysis contents sufficiently for more efficient lines management in the KEPCO, but it is problem that the existing information of electronic lines management system is not. In this study, we constructed power transmission and power distribution underground facility management system for the user to manage and maintain underground facilities more easily and safely using the information of geography and property about power transmission and power distribution underground facility which have been built by KEPCO.

  • PDF

Characteristic Analysis of Power Optical Fiber Composite Cable System on Underground Transmission Lines (지중송전선로 광 복합 전력케이블 시스템 특성분석)

  • Jung, Chae-Kyun;Park, Hung-Sok;Jang, Tai-In;Kang, Ji-Won;Kim, Jong-Chae;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.531-532
    • /
    • 2011
  • This paper describes the characteristics analysis of power-optical fiber composite cable on underground transmission lines. The effects on grounding, air gap and contact resistance are variously analysed using EMTP in normal operating condition. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines.

  • PDF

Analysis of induced voltage of CCPU with unbalanced current from Distribution Line on Underground Transmission Cable System (지중송전계통에서 배전선 불평형전류 유입에 따른 영향 검토)

  • Kang, J.W.;Jang, T.I.;Hong, D.S.;Jung, C.K.;Yoon, D.S.;Yoon, J.K.;Kim, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.459-461
    • /
    • 2005
  • This paper analyses the induced voltage characteristic of CCPU with unbalanced current from distribution line on underground transmission power cable systems. In switching surge strokes, in order to obtain the data of induced voltage/current on CCPU, the actual proof test carried out. This paper is expected to contribute the establishment of proper protection methods of CCPU against the unbalanced current from distribution line on underground transmission power cable systems.

  • PDF

A Study on the Algorithm for Fault Discrimination and Location in Underground Transmission Lines Using Travelling Wave and Wavelet Transform (Wavelet 변환과 진행파를 이용한 지중송전선로 고장종류 판별 및 고장점 추정에 관한 연구)

  • Park, Jae-Hong;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.178-180
    • /
    • 2005
  • Recently, electrical demands increase rapidly in metropolitan areas according to the extension of urban areas. Therefore underground transmission lines are getting expanded. This paper presents the rapid and accurate algorithm for fault discrimination and fault location in underground transmission lines. This paper uses fuzzy logic method using voltage and zero sequence for fault discrimination. And this paper uses travelling wave and wavelet transform for fault location. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

A Study on the Algorithm for Fault Discrimination and Location in Underground Transmission Lines Using Travelling Wave and Wavelet Transform (Wavelet 변환 기반 진행파를 이용한 지중송전선로 고장종류 판별 및 고장점 추정에 관한 연구)

  • Park, Jae-Hong;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.350-352
    • /
    • 2005
  • Recently, electrical demands increase rapidly in metropolitan areas according to the extension of urban areas. Therefore underground transmission lines are getting expanded. This paper presents the rapid and accurate algorithm for fault discrimination and fault location in underground transmission lines. This paper uses fuzzy logic method using voltage and zero sequence for fault discrimination. And this paper uses travelling wave and wavelet transform for fault location. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

A Study on the Characteristic and Rising Cause of Sheath Circulating Current by Analysis and Measurement (해석 및 측정을 통한 시스순환전류 특성 및 상승원인 검토)

  • Gang, Ji-Won;Yang, Hae-Won
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.10
    • /
    • pp.525-533
    • /
    • 2002
  • It is common to install multiple lines in the same route. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Especially, the installation type, unbalance section length between joint boxes and zero sequence current by distribution cable have an effect on the rising of sheath circulating current in the underground transmission system. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. This paper describes the relation analysis of sheath circulating current and burying types. And also, a detailed analysis on rising cause and characteristic of sheath circulating current by considering various unbalanced conditions presents using analysis and measurement regarding cable systems which have the problem of excessive sheath circulation current.

A Protection Method with single-bonding system in EHV Underground Transmission Line (초고압 지중 케이블 시스템에 대한 편단접지시의 보호대책)

  • Kim, J.W.;Kang, D.H.;Park, K.R.;Kim, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1620-1622
    • /
    • 1998
  • The failure occurs in the system of the underground transmission line, the time of restoration is very long, the damage from stopping power supply is very serious and the cost of restoration is very great. because of these problems, the system and equipment must be protected from every electrical failure by installing protection unit. This study is summarized and compared the effects of configuration method of cable protection device with respect to surges in EHV (Extra High Voltage) underground transmission system.

  • PDF

Chararcteristics of Water Vapor Transmission in Base Resin for Underground Residential Distribution Power Cable (지중배전케이블 기저수지의 수증기 투과 전달특성)

  • Song, Jae-Joo;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.149-153
    • /
    • 2003
  • In URD(Underground Residential Distribution) power cable, experiments of WVT(Water Vapor Transmission) test on the Base Resin accomplished to specimens which contained CB(Carbon Black), anti-oxidant to base resin and made by pressing to resin of pellet or lump form. a kind of specimens was HDPE(High Density Polyethylene), MDPE(Medium Density Polyethylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). as a results of WVT test, we saw that WVT ratio was HDPE < LLDPE < MDPE≒LDPE${\ll}$ PVC. WVT properties of PVC using for jacket showed properties 15-20 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials.

  • PDF

Analysis of the Induced Voltage on the 154kV Underground Cable (154kV 지중케이블에서 유기전압의 해석)

  • Choi, Suk-Young;Yoo, Myeong-Ho;Bai, Doo-Han;Oh, Jung-Hwan;Rim, Seong-Jeong;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1184-1186
    • /
    • 1997
  • In this paper, we analyze the induced voltage and current in the underground transmission cable. To analyze it, we select the 154[kV] underground transmission system which is located in the city. In the case of the steady state, the single phase fault, and three phase fault in the underground cable, we analyze the induced voltage and current for an equivalent model through EMTP simulation. Also, the components of an equivalent model and the computer simulation using EMTP is described.

  • PDF

EMTP-Analysis of Sheath Circulating Current on Underground Transmission Cables (EMTP를 이용한 지중 송전 케이블의 시스 순환전류 분석)

  • Ha, C.W.;Kim, J.N.;Lee, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.213-215
    • /
    • 2001
  • This paper describes an improved analysis method for sheath circulating current on three-underground transmission cables using EMTP(Electromagnetic Transient Program). Author studied diversely the sheath circulating current on three-underground cables depending on the various length rate, the phase arrangement, and the grounding resistance of the sheath in the cross-bonded section. It was clear that very large circulating current is generated in cable systems due to unbalanced length rate and phase arrangement in the cross-bonded section. The analysing method for two or more underground cables will be really Improved for cable system utility.

  • PDF