• 제목/요약/키워드: underground subway station

검색결과 161건 처리시간 0.025초

Seismic performance of precast joint in assembled monolithic station: effect of assembled seam shape and position

  • Liu, Hongtao;Du, Xiuli
    • Earthquakes and Structures
    • /
    • 제17권6호
    • /
    • pp.611-621
    • /
    • 2019
  • Precast concrete structure has many advantages, but the assembled seam will affect potentially the overall seismic performance of structure. Based on the sidewall joint located in the bottom of assembled monolithic subway station, the main objectives of this study are, on one hand to present an experimental campaign on the seismic behavior of precast sidewall joint (PWJ) and cast-in-place sidewall joint (CWJ) subjected to low-cycle repeated loading, and on the other hand to explore the effect of shape and position of assembled seam on load carrying capacity and crack width of precast sidewall joint. Two full-scale specimens were designed and tested. The important index of failure pattern, loading carrying capacity, deformation performance and crack width were evaluated and compared. Based on the test results, a series of different height and variably-shape of assembled seam of precast sidewall joint were considered. The test and numerical investigations indicate that, (1) the carrying capacity and deformation capacity of precast sidewall and cast-in-place sidewall were very similar, but the crack failure pattern, bending deformation and shearing deformation in the plastic hinge zone were different obviously; (2) the influence of the assembled seam should be considered when precast underground structures located in the aquifer water-bearing stratum; (3) the optimal assembled seam shape and position can be suggested for the design of precast underground concrete structures according to the analysis results.

장소지시단서로서의 지하철역 환경디자인 기법에 관한 연구 -서울, 동경, 타이페이 사례를 중심으로- (A Study on Environmental Design Treatments of Subway Stations in Terms of Visual Cues for Place Indication - Focused on the Cases of Seoul, Tokyo and Taipei -)

  • 박혜경
    • 디자인학연구
    • /
    • 제19권5호
    • /
    • pp.351-362
    • /
    • 2006
  • 현대 대도심 지하철은 밀폐된 공간으로 노선에 따라 다수의 역이 연결되어 있어 길찾기의 문제의 발생 빈도가 높은 것으로 알려져 있다. 따라서 이용자가 자신의 위치를 인지할 수 있도록 장소적 정보를 최대한 표현하는 시각적 장소지시단서(visual cue)가 제공되어야 할 필요성이 제기되고 있다. 본 연구는 대중교통수단으로서의 지하철 사용이 늘어감에 따라 길찾기 관련 문제들에 대한 관심이 증가하는 상황에서 서울, 동경, 타이페이 주요 지하철역의 장소지시적 단서로서 역할하는 환경디자인 사례 및 사용된 디자인 기법을 조사 분석함으로써 이용자를 위한 길찾기 지원 디자인 가이드라인 도출에 기여하는 목적을 가진다. 이론연구 결과, 시각적 장소지시단서의 유형으로 유도표식, 구역차별화, 랜드마크의 방법이 도출되었고 사례조사를 통하여 유도표식에서 노선색선의 상하배열, 양면배열, 변형 그래픽 기법이, 구역차별화에서는 벽면과 바닥패턴, 기둥과, 벽면의 강조색, 마감 재료 사용에 의한 차별화 기법이, 그리고 랜드마크에서는 수퍼그래픽, 상징물, 예술장식, 장식조명 등에 의한 기법들이 도출되었다. 서울 조사대상역의 경우, 연결노선의 색을 이용한 유도 표식이 가장 적극적으로 사용되고 있었으며 바닥패턴이나 강조색을 이용한 벽면과 기둥에 의한 구역차별화도 적극 도입하고 있었다. 또한 호돌이, 훈민정음과 같은 장소의 이해를 돕는 랜드마크적 요소도 적극 활용되고 있었다. 동경 조사대상역의 경우, 유도표식에 의존하기 보다는 구역 차별화의 방법을 적극 활용하는 것으로 나타났는데 이는 공간구조와 지시내용의 복잡성 때문인 것으로 해석된다. 타이페이시 조사대상역의 경우, 전반적으로 단순하며 통일된 이미지로서 장소지시는 최소한의 표식선이나 랜드마크에 의존하고 있었다. 특히 구역차별화의 사례가 미약하였는데 이는 대부분 역이 광장형의 오픈 스페이스로서 개방된 시야가 확보되기 때문인 것으로 해석된다. 본 연구의 결과는 향후 다양한 검증을 통하여 보다 정확한 길찾기 지원적 측면의 환경디자인 가이드라인 제시로 이어져야 할 것이다.

  • PDF

지하역사에서 화재발생시 자연풍 및 강제배연의 유무에 따른 열 및 연기거동 특성 연구 (Study on Heat and Smoke Behavior Due to the Natural Wind and the Forced Smoke Ventilation for the Fire in an Underground Subway Station)

  • 장희철;김태국;박원희;김동현
    • 한국화재소방학회논문지
    • /
    • 제19권1호
    • /
    • pp.80-86
    • /
    • 2005
  • 본 연구는 지하역사 승강장 가판대에서 화재발생 시 자연풍의 영향과 강제배연 시스템의 작동 여부에 따른 열과 연기의 유동특성을 알아보기 위하여 수치해석을 수행하였다. 해석 조건으로는 1)자연풍이 없고 배연설비도 가동되지 않는 경우, 2) 자연풍은 불고 있으나 배연설비는 가동되지 않는 경우, 3) 자연풍은 없으나 배연설비가 가동되는 3가지 경우이다. 수치해석의 결과자연풍이 역사의 길이 방향으로 불고 있을 경우에는 길이방향으로 화재의 확산이 빠르게 진행되며 열과 연기가 승강장에 급속하게 확산되어 피난에 영향을 미치는 것으로 나타났으며, 배연설비가 가동될 경우 지하역사 승강장으로 열과 연기가 보다 빠르게 전파되었지만 호흡안전 높이까지 열 및 연기가 도달하는 데에는 배연설비를 작동하지 않는 경우에 비하여 훨씬 많은 시간이 소요되었다. 그리고 화재발생위치에서 자연풍이 불어오는 지하공간영역에서는 배연설비의 제연효과가 하류 측의 영역에 비하여 보다 크게 나타나는 것을 알 수 있었다. 배연설비의 작동은 연기와 열을 동시에 외부로 배출시키는 역할을 하여 승객의 시야 확보 및 피난 시간을 확보하여 주는 것으로 나타났다. 해석조건에서 가장 큰 차이를 보이는 조건2)와 조건3)에서 화재구역 내의 온도차는 약 2배 차이를 보였으며, 화재지점에서 200m 지점의 연기농도분포도 약 6배 정도의 차이를 보였다.

지하 시각요소의 표지기능(標識機能)적 상징성에 관한 연구 -서울시 지하철 및 지하역(驛)의 환경그래픽을 중심으로- (A Study on the Symbolization of the Underground Visual Elements as a Signification-Function -Focus on the Environmental Graphics of the Subway Vehicle & Station in Seoul City-)

  • 김경만
    • 디자인학연구
    • /
    • 18호
    • /
    • pp.153-162
    • /
    • 1996
  • 지하공간은 방위감각의 상실에서 오는 위치적 제한으로 인공적 표지환경에 의해 위치 및 행동방향을 결정해야 하는 부정적 환경요소가 많다. 따라서 시각언어로서의 환경그래픽이 대중적 표지기능을 갖기 위해서는 상징적 의미의 기호이론에서 연구되어야 하나 안목의 활용형태가 반복되고 지하철 관리체계의 다원화로 체계적 관리가 소홀하여 시각언어로서의 의미를 잃어가고 있다. 연구의 결과, 형태의 원인으로서 제공되는 시각적 지하 환경요소는 시각언어의 Communication 측면을 충분히 고려한 연구의 기초 위에서 도입, 관리되어야 한다고 보며, 따라서 지하 환경그래픽을 행태 유도 적 표지기능의 기호현상으로 볼 때 통사론적 기호현상과 은유적 표현으로서 화용 론, 활용형태로서의 의미론의 관점에서 연구되어야한다. 특히 색채언어, 형채 언어 등 시각적 환경요소가 내포적 의미의 보편적 표지기능이 되기 위해서는 뚜렷이 구분되는 시각언어가 활용되어야 한다.

  • PDF

수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구 (Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform)

  • 남궁형규;박세찬;김민해;김수연;권순박
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.443-449
    • /
    • 2017
  • 최근 국내 도시철도 지하역사에는 승강장 안전문의 설치로 인한 승강장의 급 배기 불균형이 일어나며, 이러한 불균형은 승강장 내 오염물질 축적과 환기부족에 의한 쾌적성 저하를 일으키는 원인이 된다. 본 연구에서는 시뮬레이션 유동해석 프로그램을 이용하여 지하역사 바닥배기 시스템의 최적화 설계를 하고, 제작된 바닥배기 시스템의 미세먼지 제거 성능을 실험으로 검증하였다. 바닥배기 시스템의 시뮬레이션 유동해석은 CFX 17.0 프로그램을 이용하였으며, HEEDS를 최적화 소프트웨어로 적용하였다. 3차에 걸쳐 이루어진 최적화 결과, 약 430 Pa의 차압과 61%의 미세먼지 제거 성능을 갖는 전체높이 1.78 m의 바닥배기 시스템이 도출되었다. 최적화 설계에 따라 실규모로 제작된 바닥배기 시스템을 이용하여 미세먼지 집진 성능 실험을 실시하였으며, 약 65%의 집진효율을 보임으로써 수치해석을 통해 도출된 최적설계 결과와 유사한 수준임을 검증하였다. 결과적으로 최적화 프로그램을 활용한 바닥배기 시스템의 설계가 급배기 불균형을 갖고 있는 지하역사 승강장에 적용 가능함을 확인하였으며, 설계된 바닥배기 시스템이 공간상의 제약으로 추가적인 배기설비 설치가 어려운 기존 지하 역사에서 배기개선 및 미세먼지 제거에 효과적으로 활용될 수 있을 것으로 판단된다.

Feasibility Analysis on Ground-level Stations and Wireless Power Transfer Technology Applications for Monorail System

  • Hwang, Karam;Chung, Jong-Duk;Lee, Kibeom;Tak, Junyoung;Suh, In-Soo
    • International Journal of Railway
    • /
    • 제7권3호
    • /
    • pp.71-79
    • /
    • 2014
  • Subway systems have been a proved method of public transport and are widely used in major cities around the world. However, the time and cost it takes to construct such systems are very high, as it requires underground tunnels. Cities in various countries have implemented monorail systems as public railway transport as it can be more economical and quicker compared to subway systems in terms of construction. In addition, it provides more convenience towards the public as it is not affected to traffic, and also provides an aerial view of the city. However, the overall construction cost for monorail systems is still significantly high, and as a possible solution to further reduce the overall cost, implementation of ground-level stations and wireless power transfer technology has been proposed in this paper. A concept application layout of ground-level stations and wireless power transfer systems has been discussed, using the Daegu monorail Line 3 system as a simulation base. The expected cost for monorail systems implementing ground-level stations and/or wireless power transfer technology has been estimated based on literature survey, and was compared with the current construction cost of Daegu monorail system. Based on comparison, it has shown that implementation of ground-level stations are the most economical, and can be easily implemented for either starting or expanding the monorail line. Implementation of wireless power transfer technology is also economical, but is more feasible when starting a new monorail line as it requires components which will alter the configuration of the train and infrastructure.

서울시 자전거 보관소의 개선방안 -서울시 지하철 연계 환승 보관소를 중심으로- (A study on bicycle storage improvement in Seoul -Focusing on the bicycle storage in Seoul subway transit links-)

  • 박연경;김승인
    • 디지털융복합연구
    • /
    • 제14권12호
    • /
    • pp.405-411
    • /
    • 2016
  • 서울시는 대체 교통수단으로서의 자전거 분담률을 높이기 위해 매년 자전거 이용시설정비 및 관리계획을 꾸준히 발표하고 있지만 지난 10년간의 자전거 분담률은 거의 제자리에 머물렀고 이용객들은 여전히 관련 시설물 이용에 불편을 겪고 있다. 이런 문제점은 지하철과 같은 대중교통과의 연계 교통수단으로서의 자전거 활용도를 떨어트리고 있다. 본 연구는 이와 같은 문제점의 해결 방안을 모색하기 위해 자전거 분담률이 높은 선진국, 네덜란드, 독일, 일본의 사례를 분석하고 환승 이용객 수가 많은 서울시 지하철역인 신도림역의 사례와 비교하여 적용 가능한 해결 방안을 살펴보았다. 독일, 네덜란드의 사례에서는 지하철 환승객에게 자전거와 대중교통의 연계를 돕고 다양한 편의를 제공하는 자전거 주차 시스템을 살펴보았고, 일본의 사례에서는 지하 매립형 타워 형태의 자전거 주차장 등과 같은 협소한 공간에 많은 자전거 수용이 가능하며 보안의 측면이나 접근성 또한 우수한 새로운 보관소의 형태를 살펴보았다. 서울시의 자전거 분담률을 높이기 위해서 시설의 양적 증가보다는 현재 시설물의 사용성 문제를 파악하고 사용자 관점에서 접근하여 주차시설에 대한 서비스와 형태적인 해결방안이 요구된다.

다중이용시설의 실내공기 미생물 오염실태에 관한 연구 (The Study On the Distribution of Indoor Concentration of Microorganism in Commercial Building)

  • 박경수;최상곤;홍진관
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.620-626
    • /
    • 2006
  • Recently, indoor air quality (IAQ) is one of the greatest problems in our modern societies. Although research for IAQ is made rapid progress but IAQ problems concerning in door microorganism contamination is required to be studied still more. So we have investigated the indoor microorganism concentration of a variety of department store, subway station, underground shopping center, kindergartens, library where people complain about the in-door air quality. The experiment on microorganism concentration of indoor air was carried out and the average of total microorganisms was measured. Comparing the experimental results with existing foreign criterion, the experimental results show that the ministry of environment recommendation microorganism concentration value ($800 CFU/m^3$) is in need of revision in the near future.

유한요소와 무한요소를 사용한 2차원 선형 지반-구조물계의 지진응답해석법 (Seismic Response Analysis Method for 2-D Linear Soil-Structure Systemsusing Finite and Infinite Elements)

  • 김재민;윤정방;김두기
    • 한국전산구조공학회논문집
    • /
    • 제13권2호
    • /
    • pp.231-244
    • /
    • 2000
  • 본 연구에서는 지하철구조물, 터널구조물 및 제방 등과 같은 2차원 지반-구조계의 지진응답해석을 위한 주파수영역 동적해석법을 제시하였다. 제시한 방법에서는 구조물과 구조물 주변 근역지반은 유한요소를 이용하고 원역지반은 주파수종속 동적무한요소를 이용하여 모형화하였다. 지진입력은 입력지진파를 수직으로 입사하는 P-파와 SV-파로 가정하여 자유장응답을 구하였으며 외부고정경계법을 적용하여 등가지진하중을 산정하였다. 본 연구기법의 검증을 위하여, 층상 자유장지반과 균질 반무한지반에 매입된 원동형 공동에 대하여 지진응답을 수행하였다. 이들을 다른 기법에 의한 해와 비교한 결과, 본 연구의 기법이 매우 정확함을 알 수 있었다. 마지막으로 지하철 역사의 지진응답해석 예제를 제시하여 본 연구의 적용성을 보였다.

  • PDF

Two dimensional finite element modeling of Tabriz metro underground station L2-S17 in the marly layers

  • Mansouri, Hadiseh;Asghari-Kaljahi, Ebrahim
    • Geomechanics and Engineering
    • /
    • 제19권4호
    • /
    • pp.315-327
    • /
    • 2019
  • Deep excavations for development of subway systems in metropolitan regions surrounded by adjacent buildings is an important geotechnical problem, especialy in Tabriz city, where is mostly composed of young alluvial soils and weak marly layers. This study analyzes the wall displacement and ground surface settlement due to deep excavation in the Tabriz marls using two dimensional finite element method. The excavation of the station L2-S17 was selected as a case study for the modelling. The excavation is supported by the concrete diaphragm wall and one row of steel struts. The analyses investigate the effects of wall stiffness and excavation width on the excavation-induced deformations. The geotechnical parameters were selected based on the results of field and laboratory tests. The results indicate that the wall deflection and ground surface settlement increase with increasing excavation depth and width. The change in maximum wall deflection and ground settlement with considerable increase in wall stiffness is marginal, however the lower wall stiffness produces the larger wall and ground displacements. The maximum wall deflections induced by the excavation with a width of 8.2 m are 102.3, 69.4 and 44.3 mm, respectively for flexible, medium and stiff walls. The ratio of maximum ground settlement to maximum lateral wall deflection approaches to 1 with increasing wall stiffness. It was found that the wall stiffness affects the settlement influence zone. An increase in the wall stiffness results in a decrease in the settlements, an extension in the settlement influence zones and occurrence of the maximum settlements at a larger distance from the wall. The maximum of settlement for the excavation with a width of 14.7 m occurred at 6.1, 9.1 and 24.2 m away from the wall, respectively, for flexible, medium and stiff walls.