• Title/Summary/Keyword: underground space

Search Result 3,588, Processing Time 0.029 seconds

중국법

  • Gang, Dae-Gyu
    • Magazine of korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.80-82
    • /
    • 2019

The Study on the Construction of Safety Management Systems on Underground Multiplex Facilites (지하 다중이용시설 안전관리 체계 구축 방안 연구)

  • Seo, Tae-Woong;Lee, Jeong-Eun;Jung, Myung-Kyun;Kim, Chang-Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.165-168
    • /
    • 2008
  • Recently, the damage which is caused by human misfortune in the underground space have increased. However the regulation and law for the underground space safety is still poor. Therefore in this paper, we propose the scheme for the construction of safety management systems on underground multiplex facilities. We analyze the problem of the current law, and present the scheme for the underground shop fire fighting facility. It contains the tree structure to management the underground space according to the construction phase, the facility and immediacy equipment. This safety management system will rearrange the scattered underground space management system.

  • PDF

A study about caculating the heating load of the wall of underground space to be used undereground temperature (지중온도를 이용한 지하공간 벽체의 난방부하 계산에 관한 연구)

  • Jeong, Soo-Ill
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • The energy crisis is culminating for the life of the fossil fuel in the future which is come to end at $30{\sim}40$ years. Moreover above 90% of the energy in our country depend on importing and the crisis is more seγious than it of other countries. So architects devote low energy house research and it means underground space research have become public opinion. But there is not an accurate and utility method calculating the heating load of underground space. In this study it is proposed that the heating load is calculated by setting adiabatic thichness of soil and predicting underground temperature. The prediction of the underground temperature is calculated by the latitude, the level, the distance from sea, the condition of earth surface.

Research on Improving Quality Management for Underground Space Integration Map - Focusing on pipe-type underground facilities - (지하공간통합지도 품질관리 개선방안 연구 - 관로형 지하시설물을 중심으로 -)

  • Bae, Sang-Keun;Kim, Sang-Min;Yoo, Eun-Jin
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.2
    • /
    • pp.221-235
    • /
    • 2020
  • The development and utilization of underground spaces are increasing as the use of land based on ground surface became limited due to rapid urbanization triggered by population growth and industrialization. Despite its merit of efficient use of limited land and space, it may contribute to occurrence of various disasters such as sinkholes and damage to underground facilities. After the sinkholes formed and occurred across the country in 2014, there has been an effort to establish Underground Space Integration Map containing 15 types of underground information. Still, there is an increasing demand to improve the quality of underground information stemmed from continuation of such events including the rupture of the hot water pipe in Goyang-si and the fire in the KT site in Ahyeon-dong, Seoul. Hereby, with the aim to improve the quality of Underground Space Integration Map, this study analyzes quality standards, regulations, and guidelines related to spatial data to improve quality inspection standards and methods included in the production rules for the Underground Space Integration Map. In particular, it suggests improvement plan for data quality management for pipe-type underground facilities, known as lifelines, which are essential part of daily life of the citizens, and the largest cause for accidents according to 15 types of underground information managed through the Underground Space Integration Map.

Rock fall on tunnel portals

  • OGGERI, Claudio;PEILA, Daniele;PELIZZA, Sebastiano;KIM, Sanghwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.4
    • /
    • pp.357-365
    • /
    • 2004
  • Tunnel portals are often located in areas where the risk of rock fall and/or detachement of rock fragments from rocky slopes is high. In this case it is necessary to design the portals so as to protect the road (i.e. using an artificial tunnel) or to instal structures that are able to intercept falling blocks on the slope. This paper deals with the design problems of these structures and includes a special analysis of net fences which have undergone a remarkable technological improvement over recent years.

  • PDF

Establishment of Design Standard and Analysis of Insulation Property for Underground Space in Architecture (건축물의 지하공간을 위한 단열재의 특성 분석 및 설계 기준 수립)

  • Hwang, Min-Kyu;Cho, Woo-Jin;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • The purpose of this study is to analyze an insulation property and to establish a design standard for the underground space in architecture. Insulation materials for this study are 12 kinds of Insulation which qualified KS standards(3 classes of EPS type 1, 3 classes of EPS type 2(Neopor), 3 classes of XPS and 3 classes of PU Boards). For insulation materials of underground space, insulating and water tightening property are desired. So conductivity for insulating and water absorption for water tightening are measured in this study. Temperature, insulation is exposed to in the underground space, is different from temperature above the ground. Conductivity is measured in a temperature of $17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$ and $26^{\circ}C$. In KS standards, water absorption are measure after 24 hours, but insulation is exposed to water for a long time in the underground. So after 110 days, water absorption are measured. As time goes by, increasing of water absorption means decreasing of water tightening and insulating. So after water absorption had measured for 110 days, conductivity has measured again. As a result, XPS is selected as optimized insulation for underground. And Conductivity of XPS insulation with water should be added by 20%.

A Study on the Construction Plan of 3D Geotechnical Information for the Support of Underground Space Safety (지하안전관리 지원을 위한 3차원 지반정보 구축 방안 연구)

  • PARK, Dong-Hyun;JANG, Yong-Gu;CHOI, Hyun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2018
  • Recently, mainly in downtown, there have been frequent safety incidents in underground space like ground subsidence and land sinking. Out of diverse coping measures, the government is carrying forward the establishment of underground space integrated map. As a core element of the underground space integrated map, the 3D geotechnical information is used as major data of underground space impact assessment obliged in accordance with the "Special Act on the Safety Control of Underground Space Safety". The construction method of 3D geotechnical information is drawn when establishing the basic establishment plan of underground space integrated map, and the continuous construction is performed by the Integrated DB Center of National Geotechnical Information. However, it is necessary to draw concrete measures with accuracy, efficiency, and utilization. This study drew the construction plan considering the accuracy, utilization, and efficiency of 3D geotechnical information for the support of underground space safety. For this, accuracy between elevation and underground level is compared using MVS and MakeJiban which are software to construct boring information with geotechnical information in geotechnical information portal system. In the results of general analysis, the milepost-based construction of whole strata in a lump would be the most suitable in the aspect of accuracy, utilization, and efficiency. Based on the results of this study, Plan to construct 3D geotechnical information will be pursued.

A Study on the Analysis of Positional Accuracy between the GPR Survey Data and Underground Space Integration Map (현장 GPR 탐사자료와 지하공간통합지도 상호위치 정확도 분석에 관한 연구)

  • SONG, Seok-Jin;CHO, Hae-Yong;HAN, Dam-Hye;KIM, Sung-Gil
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.208-216
    • /
    • 2020
  • Recently, issues regarding underground safety such as sink hole, ground subsidence and damage to old underground facilities have been increasing in urban areas, raising the need for more accurate management of underground facilities. Thus, this study derived a technique for comparing spatial data of underground facilities acquired from GPR exploration results acquired at the site with spatial data of integrated underground spatial maps. Using this underground space integrated map-linked service prototype program developed through this study, comparing the location information of the GPR exploration results and the underground space integrated map for the verification of site usability in some sections around Gangnam Station, the results demonstrated that the location of the map is 0.879m maximum, minimum of 0.101m and the average fudge factor was 0.625m. If accuracy of the GPR exploration results is guaranteed, it is judged that it can be used to improve the location accuracy of the underground space integration map.