전기자동차 화재에 따른 지하주차장 내화설계 개선 필요성 검토 (A Study on the Need for Improvement of Fire Resistance Design in Underground Parking Lot due to Electric Vehicle Fire)

  • 김해나;박준서;신종현;홍상훈;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.235-236
    • /
    • 2022
  • Electric vehicle fires in underground parking lots are very dangerous, but it is judged that the current related laws and regulations do not change, which will cause problems. As a result of the analysis for the purpose of providing an electric vehicle in an underground parking lot, fire-resistance coating is essential as it can cause an explosion in the building members made of high-strength concrete when an electric vehicle fire occurs in an underground parking lot. Since a fire occurs, it is necessary to prevent electric vehicles from parking adjacent to each other.

  • PDF

지하주차장의 내화성능 평가를 위한 차량연소실험 (The combustion test of assuming in parking space for fire resistance)

  • 강승구;김동준;이재영;原田和典;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

지하주차장 성능위주설계의 피난안전성 평가 개선에 관한 연구 (A Study on Improvement of Evacuation Safety Evaluation for Performance Based Design in Underground Parking Lot)

  • 송영주;공일천;김학중
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.85-97
    • /
    • 2019
  • 오늘날 인간의 삶의 질 향상과 다양한 욕구를 충족시키기 위한 건축물은 대형화, 고층화, 심층화, 복합화 되는 추세이며, 이에 따른 비정형화된 공간이 새롭게 창출되면서 성능위주설계대상도 증가하고 있다. 성능위주설계의 피난안전성 평가는 ASET과 RSET를 산정 비교하여 RSET이 ASET를 초과하지 않도록 하여야 한다. 그러나 지하 주차장과 같이 구획된 공간의 면적이 넓고 피난경로가 다양한 경우 현재 시행되고 있는 성능위주설계 평가 방법만으로 모든 피난경로에서 안전성을 확보하기 어려운 문제가 있다. 따라서 본 논문에서는 이러한 문제점을 극복하기 위해 현재 사용되고 있는 성능위주설계의 시뮬레이션 설정방법에 대해 먼저 고찰한 다음 지하 주차장을 대상으로 화재시뮬레이션 2가지와 피난시뮬레이션 3가지 경우를 각각 수행하여 6가지 경우에 대한 피난안전성 평가를 실시하고 비교 평가하여 문제점을 살펴보고 개선된 성능위주설계의 피난안전성 평가 방안을 제시한다.

지하주차장 화재 시 스프링클러헤드 작동 여부에 따른 천장 위 단열재의 발화 여부 (Ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire)

  • 김서영;공하성
    • 문화기술의 융합
    • /
    • 제8권1호
    • /
    • pp.461-468
    • /
    • 2022
  • 이 논문에서는 지하주차장 화재 시 스프링클러 작동 여부에 따른 천장 위 단열재의 착화 여부에 관해 연구하였다. 스프링클러 작동 여부에 따라 동일 지점의 온도변화를 측정할 경우 시나리오 1에서는 화재와 인접한 천장부의 뿜칠재(SP-2)와 천장 단열재(발포 폴리스티렌)의 경계지점의 화재 내부온도는 658.27 ℃로 분석되었으며, 천장 단열재(발포 폴리시티렌)의 발화점인 427 ℃보다 최대 내부온도가 높아 화염이 천장 단열재에 착화되어 화재가 확산하는 것으로 나타났다. 시나리오 2에서는 화재와 인접한 천장부의 뿜칠재(SP-2)와 천장 단열재(발포 폴리스티렌)의 경계지점의 화재 내부온도는 53.10 ℃로 분석되었으며 뿜칠재(SP-2)와 천장 단열재 (발포 폴리스티렌)의 경계지점 최대 내부온도가 발화점 이하가 되어 화염이 천장 단열재에 착화되지 않았다. 이로 인해 스프링클러 작동 여부에 따라 천장 단열재의 점화 가능성을 예측할 수 있었다.

아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구 (A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권3호
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

행동모드 변화 모델링에 따른 피난시간 비교분석과 활용방안 연구: 지하 주차장 사례를 중심으로 (A Study on the Comparative Analysis and Utilization of Evacuation Time according to Variation of Modelling of Behavior Modes: Focusing on the Case of Underground Parking Lot)

  • 구기경
    • 한국재난정보학회 논문집
    • /
    • 제20권2호
    • /
    • pp.284-292
    • /
    • 2024
  • 연구목적: 지하 주차장 화재는 동일 규모의 일반화재에 비하여 인명 및 재산피해의 우려가 크고 소방관의 소화활동 및 인명구조가 용이하지 않는 특성이 있다. 본 연구에서는 대상물의 피난안전성 평가를 위해 적용되는 피난 Simulation 행동모드의 변화를 기반으로 주차장 이용자의 피난안전성 확보방안에 대하여 알아보고자 하였다. 연구방법: Pathfinder 프로그램을 사용하여 CASE 별로 Simulation을 수행하였다. 연구결과: 기준값이 높아질수록 피난시간이 증가되는 것을 알 수 있었으며, Behavior는 Steering Mode 보다는 SFPE Mode에서 시간증가를 나타냈다. Priority는 무순위 지정보다는 우선순위 지정에서 시간증가를 확인할 수 있었다. 결론: 지하주차장의 피난안전성 평가을 위한 피난소요시간(RSET)과 피난안전성 확보의 건축물 피난설계는 Simulation의 Behavior Mode와 Priority을 구분하여 평가·반영되어야 한다.

효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구 (A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities)

  • 손개성;최지훈;최돈묵
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구 (Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space)

  • 백두산;김효규;박진욱;유용호
    • 한국터널지하공간학회 논문집
    • /
    • 제23권1호
    • /
    • pp.25-36
    • /
    • 2021
  • 온실가스 배출량을 줄이기 위해 내연기관 자동차에 대한 제한을 두고, 친환경자동차 보급 확대 정책을 내놓고 있다. 수소 전기자동차의 수소는 가연 범위 및 폭발 범위가 넓고, 폭발화염 전파속도가 매우 빠른 가연성 가스이기 때문에, 제조, 수송, 저장 시 누출, 확산, 점화 및 폭발 등의 위험성을 가지고 있다. 수소전기자동차의 연료탱크에는 폭발 등 위험성을 감소시키기 위해 온도감응식 압력방출장치(Thermally activate Pressure Relief Device, TPRD)가 있어, 사고가 발생했을 경우 폭발, 화재 등이 발생하기 전에 탱크 내부의 수소를 밖으로 방출한다. 그러나 지하주차장이나 터널과 같은 반밀폐공간에서 사고가 발생할 경우 공간 내 기류의 유동이 개방된 공간보다 미미하기 때문에 TPRD로부터 방출된 수소가스의 농도가 폭발하한계 이상으로 누적될 수 있는 등 문제가 발생할 수 있다. 따라서 본 연구에서는 TPRD의 노즐의 직경에 따라 시간에 따른 수소의 누출 유량을 분석하고, 반밀폐공간에서 수소가 누출될 경우 수소 농도변화를 수치해석으로 검토하였다. 노즐의 직경은 1 mm, 2.5 mm, 5 mm로 검토를 하였으며, 노즐 직경에 따라 지하주차장 내의 수소농도는 노즐의 직경이 클수록 빠른 시간에 농도가 높아지며, 최대값 또한 노즐 직경이 클수록 큰 것으로 분석되었다. 기류가 정체된 지하주차장에서는 노즐 주변에서 폭발하한계 이상의 수소 농도가 분포하는 것으로 분석되었으며, 폭발상한계를 넘지는 않는 것으로 분석되었다.

공동주택 및 오피스텔 지하층에 대한 피난 안전성 평가 (Evacuation Safety Evaluation for Apartment Complexes and Officetel under Floors)

  • 강현권;전용한
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.67-72
    • /
    • 2023
  • Human and material damage can be reduced if the risk is evaluated by engineering analysis of fire combustion products, smoke concentration, and smoke movement speed in the event of a fire in apartment houses and officetels. In this study, a lot of research on related safety evaluation in the basement needs to be studied and reflected in design, so experimental research was conducted to analyze the flow of smoke through computer simulation and provide analysis data through evacuation safety evaluation. First of all, the five-story underground parking lot subject to simulation has a large floor area, which is advantageous for improving evacuation safety performance, but it uses temperature detectors to increase detection time and fire spread speed. Second, it was analyzed that the evacuation time at all evacuation ports did not exceed the evacuation time, and as the time from the start of evacuation to the evacuation time was 216.9% compared to the travel time, it was evaluated that the safety performance of the evacuation was secured. Third, the above simulation results are a comprehensive safety evaluation based on the non-operation of fire extinguishing facilities in the fire room to increase safety, which means that smoother evacuation safety performance can be secured by linking fire extinguishing facilities.

상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구 (A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.