• Title/Summary/Keyword: underground lots

Search Result 120, Processing Time 0.027 seconds

Pattern Classification of Volatile Organic Compounds in Various Indoor Environment (다양한 실내환경 중 휘발성유기화합물 오염의 패턴 분류)

  • Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min;Kim, Ki-Youn;Kim, Jong-Cheol;Jun, Hyung-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.49-56
    • /
    • 2007
  • The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June,2005 to May,2006. Concentration of TVOCs in maternity recuperations was 2,605.7 ${\mu}g/m^3$ that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6 ${\mu}g/m^3$ also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5 ${\mu}g/m^3$, in only public childcare centers exceeded the 120 ${\mu}g/m^3$ of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4 ${\mu}g/m^3$ and 184.9 ${\mu}g/m^3$, respectively.

A Study on the Roadiside Forest in Jungeup-Gun, Chunbuk-Do -ase Study on the Roadside Forest from Wonpyung to Kamgok- (전북 정읍지역 도로 주변림에 관한 연구 -김재 원평에서 정읍 감곡 사이의 지방도 사례로-)

  • 박재철
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.22 no.1
    • /
    • pp.53-63
    • /
    • 1994
  • There are lots of forests around the Korean rural village. This study was conducted to investigate the state of the forests by the 15 forests case study of the Kamgok region in Chon-guk-Do province, Korea. The results are as follows. 1. The forests lose mostly original form by the construction of road and forest clearing for the land development business. And almostly the form of the forests is a trapezoid or roundness. 2. The forests were remained on account of the Korean cemetery customs which is burying underground. 3. The conservation of the forests becomes more difficult because of the continuous development pressure. 4. Because the scale of the forests is so small, they aren't named as the natural resort forest by the forest law. So it will be the better alternative that they are conserved and used by inducing the concept of the village resort forest. 5. Because the owenership of the forests exists in a person or a family, the forests will be destructed continuously by the cemetery development. 6. The vegetation of the upper trees in the forests is the simple forests of Pinus densiflora, Pinus rigida and bamboo. The height of upper tree is average 10-12m. And average root diameter is 13-29cm. The age of the tree is average 50 years old. The state of the forests is mostly fine. 7. It is clarified that the price of the forest land is 3-5 times expensive than the other cultivated land. 8. The forests were made by the forefathers for the purpose of the practical use and were reforested in the era 1960s, 1970s.

  • PDF

Improvement of Tunnelling Speed in Full-Face Mechanical Excavation (기계굴착에서 굴착속도의 발전경향분석)

  • Park, Chul-Whan;Park, Chan;Cheon, Dae-Sung;Synn, Joong-Ho
    • Tunnel and Underground Space
    • /
    • v.17 no.3 s.68
    • /
    • pp.225-233
    • /
    • 2007
  • Because of Norwegian topography as valleys and fjords, a large number of tunnels has been built and 59 of them have been excavated by TBM for last 30 years. Prognosis technology has been developed and improved through lots of TBM experiences, and the NTNU prediction model has been completed. This paper focuses the improvement of net penetration rate and advance rate in 14 Norwegian and 4 Koran TBM tunnelling sites of which data were reported. Through this period, net penetration rate as well as advance rate were increased to double with the improvement of disc cutter size and cutter arrangement in Norway. These rates in Korea were also increased for 15 years even though the rates were lower compared to Norwegian. It is estimated that these low rates were mainly caused by using disc cutters less than 17 inch diameter. It is expected that net penetration rate and advance rate can be increased by improvement of machine and tunnelling technology, especially by using 17 or 19 inch of the disc cutter size in the Korean full face mechanical tunnelling site.

Characterization of Asbestos Content in Friable Sprayed-on Surface Material and Airborne Asbestos Concentrations in Buildings by TEM (전자현미경을 이용한 건물내 비고형 표면자재의 석면 오염 및 기중 석면농도 특성조사)

  • Yu, Sung Whan;Kim, Hyun Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.165-175
    • /
    • 1996
  • Fourteen(14) large commercial buildings located in Seoul with friable sprayed-on surface insulation material on ceiling were investigated for fiber types in bulk material and for airborne fiber concentrations in buildings by transmission electron microscopy (TEM) in order to compare the results with those by polarized light microscopy (PLM) and phase contrast microscopy (PCM). The results were as follows: 1. Chrysotile asbestos was found in one bulk sample out of total 14 bulk samples collected. Glass fiber and mineral wool were the two major constituents of the bulk samples. 2. The Na-Mg-Si-Ca-Fe-Al ratios of the EDX spectra which were normalized with the Si peak were 0-1.0-10-8.3-4.0-4.0 in mineral wool and 0-5-10-21-0-0 in chrysotile asbestos, respectively. 3. Airborne fiber concentrations were log-normalcy distributed and the geometric mean (geometric standard deviation) fiber concentrations by TEM in the underground parking lots and inside buildings were 0.0048 f/cc(1.93) and 0.0040 f/cc(2.27), respectively with no statistical difference. In the outdoor ambient air, statistically significantly lower concentration of 0.0018 f/cc(2.04) was measured. 4. The TEM/PCM ratios of airborne fiber concentrations ranged 0.5 - 2.0 for 80 % of airborne samples analyzed, end the regression equation between TEM and PCM was PCM=-0.2724+1.1355(TEM) with the coefficient of determination $R^2=0.52$. The results of this study confirmed that the sprayed-on surface insulation material found in some commercial buildings may possibly be contaminated with asbestos fiber. Since statistically significant relationship of fiber concentrations measured by PCM and TEM inside buildings and ambient air was found, previous results by PCM in ambient air could be used to estimate the ambient fiber concentrations in knowing the ratio of TEM/PCM.

  • PDF

Analyses of the Railway Noise Transmission Characteristics of the Rooms in High-speed Train Stations Depending on Building Types (고속철도의 역사형식에 따른 철도소음의 실내 전달특성 분석)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.385-393
    • /
    • 2015
  • The speed of train has rapidly been increased in accordance with the developed railway technology. Nowadays, high-speed trains were introduced which has the speed faster than 400 km/h. In Korea, a lots of efforts were undertaken to increase the speed of train faster than 350 km/h, however noise and vibration are still the main problems to solve for realization of the high-speed train. In the case of operation speed faster than 350 km/h, it can be easily presumed that the noise and vibration damages could be increased in the train stations which are close to the passing railway tracks. Thus, the noise in the five different types of high-speed train stations were analyzed including stations built on the ground, underground, under rail, and two types on rail. The present paper predicts noises inside the stations depending on the speed of the passing trains and analyze the noise comparing with noise criteria (NC). Sound insulation performance of each part of buildings was calculated using the transmission noise formula and computer modeling, Finally, a series of processes were introduced to satisfy the aural environment with the optimum interior noise criteria by changing interior finishing materials.

A Brief Review on Uncertainty Analysis for the WIPP PA (EPA 규제에 대한 WIPP 사이트 성능평가의 불확실성 분석에 관한 검토)

  • 이연명;강철형;한경원
    • Tunnel and Underground Space
    • /
    • v.12 no.1
    • /
    • pp.52-69
    • /
    • 2002
  • The WIPP (Waste Isolation Pilot Plant), located 42km east of Carlsbad, New Mexico (NM), in bedded salt 655m below the surface, is a mined repository constructed by the US DOE for the permanent disposal of transuranic (TRU) wastes generated by activities related to defence of the US since 1970. Its historical disposal operation began in March 1999 following receipt of a final permit from the State of NM after a positive certification decision for the WIPP was issued by the EPA in 1998, as the first licensed facility in the US for the deep geologic disposal of radioactive wastes. The CCA (Compliance Certification Application) for the WIPP that the DOE submitted to the EPA in 1966 was supported by an extensive performance assessment (PA) carried out by Sandia National Laboratories (SNL), with so-called 1996 PA. Even though such PA methodologies could be greatly different from the way we consider for HLW disposal in Korea largely due to quite different geologic formations in which repository are likely to be located, a review on lots of works done through the WIPP PA studies could be the most important lessons that we can learn from in view of current situation in Korea where an initial phase of conceptual studies on HLW disposal has been just started. The objective of this art report is an overview of the methodology used in the recent WIPP PA to support the US DOE WIPP CCA and some relevant results completed by SNL.

Study on the Current Horizontal Stress Characteristics of the Tertiary Rock Formations in the Pohang Basin by Integrated Analysis with In-situ Rock Stress Measurement and Borehole Scanning Data Set (현장 초기응력 측정과 시추공 이미지 스캐닝 자료의 통합 분석을 통한 포항분지 제 3기 지층 내 수평응력 분포 특성 연구)

  • Bae, SeongHo;Jeon, Seokwon;Kim, Jangsoon;Park, Kwongyu
    • Tunnel and Underground Space
    • /
    • v.26 no.4
    • /
    • pp.304-315
    • /
    • 2016
  • In this study, the current horizontal stress characteristics of the Tertiary rock formations in the Pohang Basin are investigated on the basis of the in-situ rock stress measurements at depths from 75 m to 716 m of the 3 test boreholes in the Doumsan area, Pohang. The deep hydraulic fracturing stress measurement results indicated that the horizontal stress components in the test site appear far lower than the average ones by the linear fit for the data set measured from the other domestic sites. But, borehole scanning revealed clearly that lots of small and large scale borehole failures occurred due to the low strength characteristics of the existing rocks. To obtain more accurate and overall information on the horizontal stress direction, the integrated analysis combining the hydraulic fracturing stress measurement and borehole scanning data set were additionally carried out. The analysis results showed that in the upper sedimentary and the lower volcanic rock formation, the dominant orientations of the current maximum horizontal stress components were appeared in the range of $80^{\circ}{\sim}100^{\circ}$ (N80E~N80W) and $120^{\circ}{\sim}140^{\circ}$ (N60W~N40W), respectively. From this study result it was found that the maximum horizontal stress directions have a tendency to rotate in a clockwise direction as the rock formation changes with depth in the test site.

Numerical Analysis on Cutting Power of Disc Cutter with Joint Distribution Patterns (절리분포 양상에 따른 디스크커터의 절삭력에 관한 수치해석적 연구)

  • Lee, Seung-Joong;Choi, Sung-O.
    • Tunnel and Underground Space
    • /
    • v.21 no.3
    • /
    • pp.151-163
    • /
    • 2011
  • The LCM test is one of the most powerful and reliable methods for designing the disc cutter and for predicting the TBM (Tunnel Boring Machine) performance. It has an advantage to predict the actual load on disc cutter from the laboratory test on the real-size large rock samples, however, it also has a disadvantage to transport and/or prepare the large rock samples and to need an extra cost for experiment. Moreover it is not easy to execute the test for jointed rock mass, and sometimes the design model estimated from the test can not be applied to the real design of disc cutter. In order to break this critical point, lots of numerical studies have been performed. PFC2D can simulate crack propagation and rock fragmentation effectively, because it is useful in particle flow analysis. Consequently, in this study, the PFC2D has been adopted for numerical analysis on cutting power of disc cutter according to the different angle of joint, the different direction of joint, and the different space of joint with jointed rock mass models. From the numerical analyses, it was concluded that the bigger cutting power of disc cutter was needed for reverse cutting direction to joint rather than for forward direction, and the cutting power of disc cutter was increased with decreasing the dip angle of joint and decreasing the space of joints in reverse cutting direction. The more precise numerical model for disc cutter can be developed from comparison between the numerical results and LCM test results, and the resonable guideline is expected for prediction of TBM performance and disc cutter.

Determination of Types and Element on Parking Ramp (주차장 램프 형식 결정 및 제원 산정에 관한 연구)

  • Kwon, Sung-Dae;Kim, Yoon-Mi;Nam, Chang-Kyu;Ha, Tae-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.2021-2031
    • /
    • 2013
  • Due to the rapid economic growth within the nation, the quality of life of individuals have improved dramatically. The scope of living activities of individuals have also extended, resulting in a rapidly increasing demand for automobiles. The number of vehicles registered in Korea is rapidly increasing and will reach 188.71 million as of December 2012. Compared to the registered residents of 50.94 million provided by the Ministry of Public Administration and Security, the registered population reflects about 4 people per every automobile. Due to the high demands for vehicles, the demands for parking lots in collective housing and businesses are also increasing. In reality, the current state of expansion of parking lots are underground, due to the limited available space on ground level. Specifically, the slope of a parking lot cannot exceed 17% linear slope and 14% curved slope according to the 'parking lot laws', however studies show that the driver feels at risk for safety when stopped on the parking ramp while driving in the parking lot. This study seeks to examine the suitability of parking lot ramps, concerning the safety aspects of the driver. First, the ramp type was categorized as linear or curved, then test drives were performed based on variations of slopes, slant distances, directions and points. A survey was administered to the driver after the completion of the test drive, in order to element design for an ideal ramp. In the case of curved ramp, the results of the estimate suggests a counterclockwise, slope at a maximum of 12% incline. The maximum slope for a linear ramp was analyzed to be between 13~14%, suggesting that slope greater than 15% need to be eliminated. In conclusion, it is anticipated that the element design parking ramp reported in this study will help to serve as a reference for future parking lot related guidelines, and provide cost effective traffic safety mechanisms in future parking lot businesses to follow.

A Study on the Improvement Plans of Police Fire Investigation (경찰화재조사의 개선방안에 관한 연구)

  • SeoMoon, Su-Cheol
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.103-121
    • /
    • 2006
  • We are living in more comfortable circumstances with the social developments and the improvement of the standard of living, but, on the other hand, we are exposed to an increase of the occurrences of tires on account of large-sized, higher stories, deeper underground building and the use of various energy resources. The materials of the floor in a residence modern society have been going through various alterations in accordance with the uses of a residence and are now used as final goods in interioring the bottom of apartments, houses and shops. There are so many kinds of materials you usually come in contact with, but in the first place, we need to make an experiment on the spread of the fire with the hypocaust used as the floors of apartments, etc. and the floor covers you usually can get easily. We, scientific investigators, can get in contact with the accidents caused by incendiarism or an accidental fire closely connected with petroleum stuffs on the floor materials that give rise to lots of problems. on this account, I'd like to propose that we conduct an experiment on fire shapes by each petroleum stuff and that discriminate an accidental tire from incendiarism. In an investigation, it seems that finding a live coal could be an essential part of clearing up the cause of a tire but it could not be the cause of a fire itself. And besides, all sorts of tire cases or fire accidents have some kind of legislation and standard to minimize and at an early stage cope with the damage by tires. That is to say, we are supposed to install each kind of electric apparatus, automatic alarm equipment, automatic fire extinguisher in order to protect ourselves from the danger of fires and check them at any time and also escape urgently in case of fire-outbreaking or build a tire-proof construction to prevent flames from proliferating to the neighboring areas. Namely, you should take several factors into consideration to investigate a cause of a case or an accident related to fire. That means it's not in reason for one investigator or one investigative team to make clear of the starting part and the cause of a tire. accordingly, in this thesis, explanations would be given set limits to the judgement and verification on the cause of a fire and the concrete tire-spreading part through investigation on the very spot that a fire broke out. The fire-discernment would also be focused on the early stage fire-spreading part fire-outbreaking resources, and I think the realities of police tire investigations and the problems are still a matter of debate. The cause of a fire must be examined into by logical judgement on the basis of abundant scientific knowledge and experience covering the whole of fire phenomena. The judgement of the cause should be made with fire-spreading situation at the spot as the central figure and in case of verifying, you are supposed to prove by the situational proof from the traces of the tire-spreading to the fire-outbreaking sources. The causal relation on a fire-outbreak should not be proved by arbitrary opinion far from concrete facts, and also there is much chance of making mistakes if you draw deduction from a coincidence. It is absolutely necessary you observe in an objective attitude and grasp the situation of a tire in the investigation of the cause. Having a look at the spot with a prejudice is not allowed. The source of tire-outbreak itself is likely to be considered as the cause of a tire and that makes us doubt about the results according to interests of the independent investigators. So to speak, they set about investigations, the police investigation in the hope of it not being incendiarism, the fire department in the hope of it not being problems in installments or equipments, insurance companies in the hope of it being any incendiarism, electric fields in the hope of it not being electric defects, the gas-related in the hope of it not being gas problems. You could not look forward to more fair investigation and break off their misgivings. It is because the firing source itself is known as the cause of a fire and civil or criminal responsibilities are respected to the firing source itself. On this occasion, investigating the cause of a fire should be conducted with research, investigation, emotion independent, and finally you should clear up the cause with the results put together.

  • PDF