• 제목/요약/키워드: underground development

검색결과 1,084건 처리시간 0.025초

GIS를 활용한 지하시설물 시공의 적정성 평가 (Suitability valuation of Underground Facility Construction Using GIS)

  • 김감래;이재기;임건혁
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.465-469
    • /
    • 2004
  • The purpose of this study is to evaluate suitability of Underground Facility Construction in great land development area. Because there are the construct of national integration information control system and the advance of information technique, the necessity that construct the UIS to manage the urban space systematically is enlarged. In the purpose that we prepare the base of underground facility management system by driving the step digitalizing facilities buried underground and protect urban safety accident, we introduce the GIS in land development area. This study proposes the improvement direction by examining the outcome through the driving method and the outcome analysis.

  • PDF

부력 추를 이용한 지하수위 측정용 센서 개발 (Development of High Precision Underground Water Level Meter Using a Buoyant Rod Load Cell Technique)

  • 이부용;박병윤
    • 한국농림기상학회지
    • /
    • 제1권1호
    • /
    • pp.36-40
    • /
    • 1999
  • A new method was developed to measure underground water level with high reliability. The principle of new method was to detect a change of a buoyant force according to change in water level of underground water measured by the use of a straingage load cell. Field test of the instrument was carried out in Cheju Island. The results were as follows; 1) The present study provided a possibility to develop a new underground water level meter. 2) This new instrument accomplished high reliability at field test in Cheju Island. 3) There is possibility of development of water level meter which measure various range of water level to detect a weight change of a buoyant forcd.

  • PDF

Performance Analysis of the Linear Induction Motor for the Deep-Underground High-Speed GTX

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.200-206
    • /
    • 2012
  • In order to develop a deep-underground great train express (GTX) in South Korea, the specifications decision and development of a traction control system (including an inverter and a traction motor), which considers a variety of route conditions, must be advanced. In this study, we examined the running resistance properties of a high-speed traction system based on a variety of tunnel types and vehicle organization methods. Then, we studied the power requirements necessary for the traction motor to maintain balanced speed in the high-speed traction system. From this, we determined the design criteria for the development of a high-speed traction system for use in the deep-underground GTX. Finally, we designed a linear induction motor (LIM) for a propulsion system, and we used the finite element method (FEM) to analyze its performance as it travelled through deep-underground tunnels.

3차원 지하시설물 가공 및 부분갱신 자동화 기술개발 - 지하공간통합지도 중심으로 - (Development of 3D Underground Utilities Processing and Partial Update Automation Technology - Focused on 3D Underground Geospatial Map -)

  • 이민규;최성식;전흥수;김성수
    • 한국지리정보학회지
    • /
    • 제23권4호
    • /
    • pp.1-15
    • /
    • 2020
  • 도시가 확장되고 지하시설물 관련 공사가 늘어남에 따라 지하시설물 관로 네트워크를 3차원으로 분석할 수 있는 기술이 절실히 요구되고 있다. 국내에서는 2015년부터 15종의 지하정보(지하시설물, 지하구조물, 지반)를 3차원 기반 지하공간통합지도로 구축하는 사업을 진행하고 있다. 하지만 현재 3차원 지하시설물 구축은 수작업 기반으로서 구축 방법이 매우 복잡하고 지자체별 수백만 건이 넘는 대용량 데이터를 처리하기에는 시간과 비용이 많이 발생한다. 본 논문은 3차원 지하시설물 모델의 가공 및 갱신 자동화 구축 프레임워크를 제시함으로써 3차원 지하시설물 모델을 최소비용으로 신속하게 구축하는 방안을 수립하였다. 본 연구에서 개발된 지하시설물 가공 및 부분갱신 자동화 기술들은 지하공간통합지도 구축사업에 즉시 현장적용이 가능할 것으로 기대한다.

지중배전선로 무정전 공법의 최적화를 위한 장비 개발 (Development of outage-free installation method and equipments for underground power distribution system)

  • 유근양;주종민;이용순;김영민;강내국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.122-124
    • /
    • 2005
  • Underground distribution system is a trend due to the successive development of metropolitan area and satellite cities and the environment of the commercial and residential areas. The high quality of electricity, which is related with the minimal outage duration time due to the maintenance work for the underground distribution line, is mandatory. Hence, the construction method and tools for the outage-free maintenance construction have been required for underground distribution system. So far, all the efforts for outage-free maintenance for the underground distribution have been limited only to the survey for foreign countries situation and the theoretical provision; thus, It is required to develop the various construction method and the application tools. Differently from the aerial line, the construction of the underground cable is complicated and the insulation distance between conductor and shield should be maintained in loadmaking/breaking operation, though the apparatus connected with cable is a deadfront type. Also since the apparatus is installed above ground, by-pass of faulted area at busy area needs a variety of high technologies. Therefore, in this these, the authors introduce the development status of the loadbreak connectors, connection facilities, outage-free maintenance system for secondary side, a secondary auxiliary bushing and additional tools so that there can be more progress on this field.

  • PDF

A Study on Facility Information System using GIS and Semantic Web in Underground Space

  • Cui, Yulan;Hwang, Hyun-Suk;Kim, Chang-Soo
    • 한국멀티미디어학회논문지
    • /
    • 제13권12호
    • /
    • pp.1843-1854
    • /
    • 2010
  • The utilization of underground space has recently increased with the complication of road, the rise of the land price, and the development of green technology. Underground space ranges from classical excavations to subway, underground cities, and shopping malls where there are crowds of people. At this time, government has spent a lot of money in installing various types of safety facilities for preparations of increasing potential disasters. Therefore, an effective facility management system is required. In this paper, we propose an information retrieval process to effectively extract the facilities' information based on the ontology and spatial analysis in underground space. The ontology-based searching supports hierarchical and associated results as well as knowledge sharing with hierarchy concepts. The spatial analysis based searching has "Buffer" and "Near" functions to operate on a map without understanding any property of the facility information.

캐나다 Underground Research Laboratory 건설을 위한 조절발파기법의 적용 (Controlled Blasting Technique Applied to the Construction of the Canada Underground Research Laboratory)

  • 권상기
    • 화약ㆍ발파
    • /
    • 제23권2호
    • /
    • pp.1-14
    • /
    • 2005
  • 한국원자력연구소는 현재 국내 원전에서 발생하는 고준위폐기물의 처분과 관련된 연구개발을 위해 지하연구시설을 계획 중에 있다. 본 논문은 캐나다 URL 에서의 건설에 적용된 굴착기법과 향후 국내의 유사한 지하연구시설과 향후에 추진될 고준위폐기물 처분장에 대한 적용에 대해 논의하고자 한다

제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 - (The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area -)

  • 강연구;임태섭
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.