• 제목/요약/키워드: underground development

검색결과 1,084건 처리시간 0.03초

실시간 지중 전력케이블 용량 평가를 위한 토양 열 특성 및 온도 측정 시스템 개발 (Development of the Soil Thermal Property and Temperature Measurement System for the Real-time Ampacity Estimation of Underground Power Cables)

  • 정성환;김대경;최상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.22-24
    • /
    • 2002
  • This paper introduces the real-time soil thermal property analyzer and temperature measuring system which is combined with radio telecommunication technique. To measure the thermal parameters in real-time, the radio telecommunication technique are used the personal communication service (PCS) which is in the world-wide serviced commercially firstly by CDMA. The thermal property analyzer has an ability of measuring thermal resistivity, thermal diffusivity and thermal stability. To estimate the soil thermal properties, the curve fitting algorithm by means of the least square method are used. TCP/IP protocol and MTM are used to install the real-time soil thermal property and temperature measurement system at multiple locations along routes of the underground power cables and to reduce the cost of telecommunication.

  • PDF

지중 송전설비의 효율적 운영 (The efficient management of the underground Power transmission facilities)

  • 이석규;조성우;최경규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1385-1387
    • /
    • 1999
  • Electric power consumption is highly increasing as the social trend requiring comfortable life, the population concentration in a big city and the industrial development. Therefore it has become to be very important to supply the stable high-quality power. As these trends, the underground power transmission facilities are unavoidable in the center of a city and are going to increase more and more. As the proportion to increase facilities, the efficient management and maintenance become more important and are going to play an important role in the high-quality of power supply.

  • PDF

송전케이블 삼상단락 실증시험을 통한 전자력 대책방안 연구 (The Study on Countermeasures of Electromagnetic Force by Three Phase Short-Circuit Test of Underground Transmission Cable)

  • 강지원;박흥석;윤종건;김양상;홍동석;장우석
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2342-2348
    • /
    • 2009
  • Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, the interaction of electromagnetic force by fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, and close consideration is required for it. This paper presents countermeasures to reduce and release the effect of electromagnetic force with rope binding and installation of spacer and describes its efficacy through three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

SWT와 진행파를 이용한 지중송전계통 고장점 추정 기법 개발 (Development of Fault Location Method Using SWT and Travelling Wave on Underground Power Cable Systems)

  • 정채균;이종범
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.184-190
    • /
    • 2008
  • The fault location algorithm based on stationary wavelet transform was developed to locate the fault point more accurately. The stationary wavelet transform(SWT) was introduced instead of conventional discrete wavelet transform(DWT) because SWT has redundancy properties which is more useful in noise signal processing. In previous paper, noise cancellation technique based on the correlation of wavelet coefficients at multi-scales was introduced, and the efficiency was also proved in full. In this paper, fault section discrimination and fault location algorithm using noise cancellation technique were tested by ATP simulation on real power cable systems. From these results, the fault can be located even in very difficult and complicated situations such as different inception angle and fault resistance.

EMTP 기반 지중송전계통 해석용 시뮬레이터 개발 및 응용 (Development and Application of EMTP based Simulator for Analysis of Underground Power Cable Systems)

  • 정채균;이종범;이원교;이동일;황갑철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.320-321
    • /
    • 2008
  • In this paper, new simulator based on EMTP was introduced for simulation of underground power cable system. The newly developed simulator was named as Power Cable Simulator(PCS), and it can simulate the various normal conditions including sheath circulating current. It is also easier to use than conventional software, such as EMTP and CabSim, because all the data for calculating the cable parameters are stored in a database(DB) within a PCS. In addition, the accuracy of PCS is also proved through the comparison between the calculation and simulation of sheath current.

  • PDF

지하구 상태감시 고도화를 위한 지능형궤도주행 이동 감시장치 개발적용 (Development and application for intelligent rail mobile system for monitoring the underground electric power facilities)

  • 박수신;김태옥;최경규;김선인;배태우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.400-401
    • /
    • 2015
  • It is brought up the electric power shortage for particular dense population areas. Due to this, the high quality economical and eco friendly electric power facilities are needed. Also, the inconvenience of maintenance is significantly increasing in case of power cut and black out. For avoiding power failure of underground electric power facilities, the precise preventive maintenance is compulsory but there are apparent limitations. In this paper, the intelligent rail mobile system is described to overcome the limitations.

  • PDF

초고압 고내력 케이블 국내 최초 현장 적용 (First Installation of High Stress EHV XLPE Cable in korea)

  • 오종옥;조성훈;이상교;김한중;오동수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1057-1059
    • /
    • 1999
  • Recently, increased demand of electrical energy caused additional installation of underground power cable, Industrialization of metro makes civil works difficult. So installed ducts became a key of underground power transmission, LG cable set to work development of high stress cable. LG cable stated in 1996, got a certificate of type test in 1998, and applied at domestic site in Nov. 1999. High stress cable has some merit, decrease of civil cost, reduction of work time, by reason of decrease of dia. and weight, and economical system design, so LG cable has a good merit in comparison with competitive company in domestic and foreign market.

  • PDF

일자유면 암반 굴착을 위한 신바파공법의 개발 및 평가 (Development and evaluation of new drilling and blasting method for excavaton of rock mass with one free surface)

  • 임재웅;윤영재;서정복
    • 터널과지하공간
    • /
    • 제4권3호
    • /
    • pp.237-249
    • /
    • 1994
  • A new type of cut method, called SK-cut, was developed in order to overcome the shortcomings of the conventional V-cut and Burn-cut blasting methods. Total 190 times of test blasts were performed for the evaluation of the efficiency of new blasting method. V-cut, Burn cut and SK-cut were compared by applying them to the excavation of main gallery and construction tunnel of underground oil storage cavern. Test results showed that excavation efficiency of the new method was increased by 5.9~9.8% and that specific charge was reduced to 71~92%.

  • PDF

암석의 변형 및 파괴거동의 해석을 위한 균열모형 개발에 관한 연구 (Development of a Mechanical Crack Model to Analyze Deformation and Failure Mechanism of Rock)

    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.96-106
    • /
    • 1998
  • Rock contains discontinuities at all scales. These discontinuities make rock behave in a complex way. This paper discusses a new approach to underground design based on the theory of rock fracture mechanics. The mechanism of deformation and failure of coal was studied by observing the distributions of length, orientation and spacing of the pre-existing as well as stress-induced cracks. Different types of crack information. The crack information is dependent on the scale used. The cracks propagate along the intersections of the pre-existing cracks, and both extensile and shear crack growth occur depending on the direction of the load relative to the bedding planes. An analytical model that takes into account both shear and extensile crack growth was developed to predict the nonlinear stress-strain behavior of coal including strain-hardening and strain-softening.

  • PDF

UFSN의 지하시설물관리 시스템 적용에 관한 연구 (A Study on the Development of Underground Facility Management System using UFSN)

  • 권혁종;임형창;송병훈;김정훈;한재일
    • 대한공간정보학회지
    • /
    • 제16권2호
    • /
    • pp.9-15
    • /
    • 2008
  • 본 논문에서는 UFSN 센서를 이용하여 지하시설물관리시스템에서 유량, 유속, 압력, 진동 등 상수관로의 정보를 실시간으로 모니터링 하는 방안에 대한 연구를 하였다. UFSN 센싱 데이터 제너레이터, 게이트웨이와 미들웨어를 개발하였고, UFSN 센싱 데이터 포맷을 정의하여 센싱 데이터 전송을 검증하였다. 기존 지하시설물관리 시스템에 센싱데이터를 저장하여 GIS 도면 기반의 실시간 상수관로 모니터링을 수행하였다.

  • PDF