• Title/Summary/Keyword: underground development

Search Result 1,084, Processing Time 0.027 seconds

Properties of Alkali-Activated Cement Mortar by Curing Method (양생 방법에 따른 알칼리활성 시멘트 모르타르의 특성)

  • Kim, Ji-Hoon;Lee, Jae-Kyu;Hyung, Won-Gil
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • Globally, there are environmental problems due to greenhouse gas emissions. $CO_2$ emissions rate of the cement industry is very high, but the continued demand of cement is needed in the future. In this study, in order to reduce the environmental impact of $CO_2$ emissions from cement production. The experiments were carried out for the development of non-sintered cement (have not undergone firing burning) by granulated ground blast furnace slag. In order to compare the characteristics by curing, an experiment was conducted by changing the curing conditions such as atmospheric steam curing, observe the mechanical properties for the measurement of flexural compressive strength by mortar, observe the chemical properties such as acid resistance, $Cl^-$ penetrate resistance and analyzed the mechanism of hydration by XRD, SEM experiments. From the experimental results, as compared with portland cement usually confirm the mechanical and chemical properties excellent, it is expected be possible to apply to the undersea, underwater and underground structures that require superior durability. In addition, based on the excellent compressive strength by steam curing, it is expected to be possible to utilize as a cement replacement material in the secondary product of concrete. In the future, to solve the problem through continued research, it will be expected to reduce the effect of environmental load and to be excellent economics.

Development of an Artificial Neural Expert System for Rational Determination of Lateral Earth Pressure Coefficient (합리적인 측압계수 결정을 위한 인공신경 전문가 시스템의 개발)

  • 문상호;문현구
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.99-112
    • /
    • 1999
  • By using 92 values of lateral earth pressure coefficient(K) measured in Korea, the tendency of K with varying depth is analyzed and compared with the range of K defined by Hoek and Brown. The horizontal stress is generally larger than the vertical stress in Korea : About 84 % of K values are above 1. In this study, the theory of elasto-plasticity is applied to analyze the variation of K values, and the results are compared with those of numerical analysis. This reveals that the erosion, sedimentation and weathering of earth crust are important factors in the determination of K values. Surface erosion, large lateral pressure and good rock mass increase the K values, but sedimentation decreases the K values. This study enable us to analyze the effects of geological processes on the K values, especially at shallow depth where underground excavation takes place. A neural network expert system using multi-layer back-propagation algorithm is developed to predict the K values. The neural network model has a correlation coefficient above 0.996 when it is compared with measured data. The comparison with 9 measured data which are not included in the back-propagation learning has shown an average inference error of 20% and the correlation coefficient above 0.95. The expert system developed in this study can be used for reliable determination of K values.

  • PDF

Effect of Metal Ions on the Oxidation of Soybean Oil and Its Fried Noodle (각종(各種) 금속(金屬) 이온이 대두유(大豆油)및 그 튀김 면(麵)의 산패(酸敗)에 미치는 영향에 대(對)하여)

  • Choe, Myen;Kim, Tae-Woong;Lee, Yang-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.157-164
    • /
    • 1977
  • In the present study, the proxidant effect of ferrous and cupric chlorides which added to soybean oil and its fried noodle in the same concentration of the city water and the physically refined underground water were determined. As the inhibitor of metal proxidation, BHA and citric acid which are used widely in oil industry as antioxidants were compared. In both cases of soybean oil and its fried noodle, the addition of cupric chloride and ferrous chloride showed prominent proxidant effect. Especially, cupric chloride marked more proxidant effect than ferrous chloride by 3 to 6 times with the elapse of time. In the inhibition activity of metal proxidation, citric acid was more effective than BHA. The 1ppm of Cu +0.01% of citric acid treated soybean oil showed less proxidant effect than the control at the later stage. The inhibition activity of citric acid on $Fe^{++}$ in soybean oil was more effective than $Cu^{++}$ in soybean oil.

  • PDF

Evaluation of Insulation Deterioration for the Development of SVM Algorithm to Diagnose OF Cable (OF 케이블 진단용 SVM 알고리즘 개발을 위한 절연열화 평가)

  • Kwak, Byeong Sub;Jun, Tae-Hyun;Kim, Ah-Reum;Park, Hyun-joo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.263-273
    • /
    • 2019
  • South Korea's OF cable is reaching its expected design life of 30 years, and as a result, the risk of failure is increasing. Therefore, it is necessary to diagnose the long-term operating OF cables through accurate diagnosis at the right time to prevent the failure. Currently, the KEPCO periodically conducts DGA. However, the gas found in DGA is caused by oil deterioration as well as insulation paper. Therefore, the analysis of the degree of polymerization and furan compounds which is an evaluation of insulation paper considered to be the life of OF cables is required. In addition, the results of the evaluation of deterioration of insulation paper need to be checked for correlation with the results of DGA. In this study, DGA carried out through GC, the degree of polymerization was analyzed using an automatic viscometer, and HPLC was used to detect the furan compounds. In addition, the obtained results were applied to the SVM technique, which was recently introduced to determine abnormalities in OF cable. And the results which were accurate and reliable were obtained.

High Efficient Inductive Power Supply System Implemented for On Line Electric Vehicles

  • Huh, Jin;Park, Eun-Ha;Jung, Gu-Ho;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.105-110
    • /
    • 2009
  • The On Line Electric Vehicles(OLEV) that can pick up inductive power from underground coils on driving with high efficiency have been developed this year, and is now proposed in this paper. The IPS(Inductive Power Supply) system consists of power supply inverters, power supply rails, pick up modules, and a regulator. There are 3 generations of IPS have been developed so far, and the $4^{th}$ generation IPS is being developed. The $1^{st}$ generation has been demonstrated this Feb. 27, which is equipped with mechanically auto tracking pick-up module with 1cm air gap, and showed 80% power efficiency. The $2^{nd}$ generation IPS applied to an 120kW (average)/240kW(peak) motor powered electric bus has 17cm air gap with 72% power efficiency. For the $2^{nd}$ generation IPS, the Power supply inverter has 440V, 3phase input and 200A @ 20kHz output. The test power supply rail of 240m long is segmented by 60m each, where newly developed core structure and power cable are constructed under the road covered with asphalt of 5cm thickness. The pick-up modules which consist of core, winding wire, and rectifiers are fixed to the bottom of the bus which can carry more than 40 passengers and can pick up max. 60kW. To remove parasitic component and to transfer maximum power between them resonant circuit topology is applied to the primary and secondary sides. The EMF level is below 62.5mG at 1.75m from the center of the road to meet the regulation. Several effective ways of reducing EMF levels have been developed. In addition, effective ways to solve problems related high frequency power cables buried in ground and it's proof from soil have been studied also. This development shows that the IPS system is capable of supplying enough power to the pick-up of OLEV and can reduce battery size, weight and cost, which means the IPS with OLEV is one of the best candidate for EV.

  • PDF

Development and Application of Mode II Fracture Toughness Test Method Using Rock Core Specimen (시추코어를 이용한 암석의 mode II 파괴인성 시험법 개발과 적용)

  • Jung, Yong-Bok;Park, Eui-Seob;Kim, Hyunwoo
    • Tunnel and Underground Space
    • /
    • v.26 no.5
    • /
    • pp.396-408
    • /
    • 2016
  • Rock fracture mechanics has been widely applied to various fields of rock and civil engineering. But most researches covered mode I behavior, though mode II behavior is dominant in rock engineering. Until now, there is only one ISRM suggested method for mode II toughness of rock. A new SCC (Short Core in Compression) mode II toughness test method was developed considering 1) application of confining pressure, 2) easiness of notch creation, 3) utilization of existing equipment, 4) simple test procedure. The stress intensity factors were determined by 3D finite element method considering line and distributed loading conditions. The tests with granite specimens were carried out using MTS 815 rock test system with a loading rate of 0.002 mm/s. The mean value of mode II fracture toughness of granite showed $2.33MPa{\sqrt{m}}$. Mode I toughness of the same granite was $1.12MPa{\sqrt{m}}$, determined by Brazilian disk test and $K_{IIC}/K_{IC}=2.08$. The smooth fracture surface with rock powder formation also supported mode II behavior of SCC method. The SCC method can be used for the determination of mode II fracture toughness of rocks based on the current results.

Development of Integrated Type Main Frame and Downhole Sonde Apparatus for Hydraulic Packer Testing in Seabed Rock under High Water Pressure (고수압 해저지반 수리특성 조사용 일체형 메인 프레임과 공내 측정장치 개발)

  • Bae, SeongHo;Kim, Jangsoon;Jeon, Seokwon;Kim, Hagsoo
    • Tunnel and Underground Space
    • /
    • v.28 no.3
    • /
    • pp.258-276
    • /
    • 2018
  • The accurate and quantitative ground information on the hydraulic conductivity characteristics of rock mass is one of the key factors for evaluation of the hydro-geological behaviour of rock mass around an excavated opening under high water pressure. For tunnel and rock structures in seabed, where the sea acts as an infinite source of water, its importance become greater with increasing construction depth below sea level. In this study, to improve the problems related with poor system configuration and incorrect data acquisition of previous hydraulic packer testing equipment, we newly developed an integrated main frame and 30 bar level waterproof downhole sonde apparatus, which were optimized for deep hydraulic packer test in seabed rock mass. Integration of individual test equipment into one frame allows safe and efficient field testing work on a narrow offshore drilling platform. For the integrated type main frame, it is possible to make precise stepwise control of downhole net injection pressure at intervals of $2.0kg_f/cm^2$ or less with dual hydraulic oil volume controller. To ensure the system performance and the operational stability of the prototype mainframe and downhole sonde apparatus, the field feasibility tests were completed in two research boreholes, and using the developed apparatus, the REV(Representative Elementary Volume) scale deep hydraulic packer tests were successfully carried out at a borehole located in the basalt region, Jeju. In this paper, the characteristics of the new testing apparatus are briefly introduced and also some results from the laboratory and in-situ performance tests are shown.

Relations between Electrical and Hydraulic Properties of Aquifer in the Ganam Area (가남지역 대수층의 전기적, 수리적 특성 사이의 관계)

  • 이기화;최병수;한원석
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.2
    • /
    • pp.78-84
    • /
    • 1995
  • In 1983, 83 Wenner vertical electrical sounding(VES)s and 22 pumping tests had been carried out by Korea Agricultural Development Corporation(KADC) in Guam Myun, Yeoju Gun, Kyounggi Province. Also, 10 boreholes had been constructed in the area. Using these data electrical and hydraulic properties of aquifer in the Ganam area are investigated in this study. Assuming that the underground is 1-D, VES data are analyzed. Data analysis shows that the subsurface of study area can be interpreted as 4-layer structure and the 3rd layer which is regarded as aquifer has mean thickness of 10 m and mean resistivity of 506 ohm-m and rests on resistive bedrock. Under the circumstances, as most part of electric current flows parallel to the bedding, longitudinal unit conductance is an important parameter controlling VES curves and very closely correlates with transmissivity of aquifer in the study area. Thus, relation between longitudinal unit conductance and transmissivity is investigated in this study. Since resistivity and thickness of each layer are obtained from interpretation of VES data, the relations between transmissivity and resistivity, and between hydraulic conductivity and resistivity are also studied. Studies of such relations show that longitudinal conductance is proportional to transmissivity, and resistivity is inversely proportional to transmissivity and hydraulic conductivity.

  • PDF

Reviews on the Studies of MTBE Contaminants in Groundwater

  • 이지훈;이진용;천정용;이강근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.55-58
    • /
    • 2000
  • Methyl tertiary butyl ether (MTBE) is a gasoline additive that boosts the oxygen content in fuel (an oxygenate), resulting in less air-polluting carbon monoxide being released from vehicle exhaust systems. Then, groundwater contamination problems have been developed in areas where the chemical is used. Common sources of water contamination by MTBE include leaking underground gasoline storage tanks and leaks and spills from above ground fuel storage tanks, etc.. Studies on the chemical and these problems are going on abroad vigorously. These studies should be performed in our country as well more actively. This paper reviews on articles on these studies and focuses on the identification of the chemical as a groundwater contamination source.

  • PDF

Effect of Space Limitation of Rhizosphere on Morphology and Development of Root System in Tobacco Seedlings (담배 육묘시 근권의 공간 제한이 근계의 형태와 발달에 미치는 영향)

  • 이상각;심상인;강병화
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.4
    • /
    • pp.475-481
    • /
    • 1996
  • This study was carried out to acquire the basic information of root growth under different pot size, imposing different space limitation on rhizosphere. Different size of pots that had same surface area but different depth, 5cm(Iength)$\times$5cm(width)$\times$30, 15, 5cm(depth), were used during the seedling stage of tobacco plant. Space limitation on rhizosphere affected not only the aerial growth, stem height, leaf area and shoot dry weight, but also root growth and root architecture. Aerial growth was highly related to growth of underground part, so space limitation on rhizosphere decreased aerial growth. Limitation on pot volume by reducing pot depth induced new rooting on crown. Root number and relative multiplication rate were higher in small pot that had 5cm depth than large pot, but total root length and mean extension rate showed reverse patterns. Root numbers of 1st order and 2nd order were increased as pot depth was increased, but the root number of 3rd order was increased in small pot. Root system of seedling grown in large pot distributed more horizontally than that in small pot at 20 days after temporary planting (DAT), but the root architecture of seedling was reversed at 25 DAT.

  • PDF