• Title/Summary/Keyword: underground depth

Search Result 653, Processing Time 0.036 seconds

Gravity Field Interpretation and Underground Structure Modelling as a Method of Setting Horizontal and Vertical Zoning of a Active Fault Core (활성단층의 3차원적인 규모를 결정하기 위한 중력장 데이터의 해석 및 지각구조 모델링: 양산단층에서의 예)

  • Choi, Sungchan;Kim, Sung-Wook;Choi, Eun-Kyeong;Lee, Young-Cheol;Ha, Sangmin
    • Economic and Environmental Geology
    • /
    • v.54 no.1
    • /
    • pp.91-103
    • /
    • 2021
  • In order to estimate the vertical and horizontal structural in the Yangsan fault core line (Naengsuri area, Pohang), we carried out gravity field measurements and interpretation procedures such as Euler deconvolution method and curvature analysis in addition to the forward modelling technique (i.e. IGMAS+). We found a prominent gravity difference of more than 1.5 mGal across the fault core. This indicates a distinct density difference between the western and eastern crustal area across the Yangsan fault line. Comparing this gravity field interpretation with other existent geologic and geophysical survey data (e.g. LiDAR, trenching, electric resistivity measurements), It is concluded that (1) the prominent gravity difference is caused by the density difference of about 0.1 g/㎤ between the Bulguksa Granite in the west and the Cretaceous Sandstone in the east side, (2) the fault core is elongated vertically into a depth of about 2,000 meters and extended horizontally 3,000 meters to the NNE direction from Naengsuri area. Our results present that the gravity field method is a very effective tool to estimate a three -dimensional image of the active fault core.

Conceptual Design and Displacement Recognition Performance Verification of Displacement Measurement System for Retaining Wall Structure Based on Laser Sensor (레이저 센서 기반 흙막이 구조체 변위 계측 시스템의 개념 디자인 및 변위 인식 성능 검증)

  • Kim, Jun-Sang;Lee, Gil-yong;Kim, Young Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.1
    • /
    • pp.64-72
    • /
    • 2022
  • The retaining wall structure is essential for construction work that performs underground excavation. Displacement management of the retaining wall structure is important regardless of the size of the construction. However, in the case of small-scale construction sites with an excavation depth of less than 10m, displacement management of retaining wall structure not properly performed due to problems such as 1) companies' smallness, 2) lack of capacity of construction managers, 3) complexity of installation, dismantling and displacement of measuring instruments. As a result of analyzing previous research, it was analyzed that it is difficult to apply this to a small - scale construction site because most of the previous research has problems in using an expensive 3D scanner or installing many measuring instruments. This study aims to propose a conceptual design of a displacement measurement system for retaining wall structure based on laser sensor and to verify the displacement recognition performance of core technology applied to the conceptual design. A conceptual design was proposed using a 2D laser scanner. As a result of verifying the displacement recognition of the 2D laser scanner, a displacement of 15mm was analyzed to be sufficiently understandable. In the future, if the proposed conceptual design is developed and applied to the small-scale construction site, it is thought that it will contribute to the reduction of safety accidents at small-scale construction sites.

Design of Submarine Cable for Capacity Extension of Power Line (전력선 용량증대를 위한 해저케이블 설계)

  • Son, Hong-Chul;Moon, Chae-Joo;Kim, Dong-Sub
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.77-84
    • /
    • 2022
  • A submarine power cable is a transmission cable for carrying electric power below the surface of the water. Recently, submarine cables transfer power from offshore renewable energy schemes to shore, e.g. wind, wave and tidal systems, and these cables are either buried in the seabed or lie on the ocean floor, depending on their location. Since these power cables are used in the extreme environments, they are made to withstand in harsh conditions and temperatures, and strong currents. However, undersea conditions are severe enough to cause all sorts of damage to offshore cables, these conditions result in cable faults that disrupt power transmission. In this paper, we explore the design criteria for such cables and the procedures and challenges of installation, and cable transfer splicing system. The specification of submarine cable designed with 3 circuits of 154kV which is composed of the existing single circuit and new double circuits, and power capacity of 100MVA per cable line. The determination of new submarine cable burial depth and cable arrangement method with both existing and new cables are studied. We have calculated the permission values of cable power capacity for underground route, the values show the over 100MW per cable line.

Evaluation of Segment Lining Fire Resistance Based on PP Fiber Dosage and Air Contents (세그먼트 라이닝의 PP섬유 혼입량과 공기량 변화에 따른 화재저항 특성 평가)

  • Choi, Soon-Wook;Kang, Tae Sung
    • Tunnel and Underground Space
    • /
    • v.31 no.6
    • /
    • pp.469-479
    • /
    • 2021
  • As a material for preventing spalling of concrete, the effectiveness of PP fiber has already been confirmed. However, it is necessary to consider the maximum temperature that occurs during a fire, and to solve the mixing problem and the strength reduction problem that occur depending on the mixing amount. In this study, the fire resistance performance of tunnel segment linings according to the PP fiber content and air volume under the RABT fire scenario was investigated. As a result, no spalling or cross-sectional loss occurred in all test specimens, and when the PP fiber content was small, the maximum temperature was relatively high and the maximum temperature arrival time was also fast. On the other hand, no trend was found for the maximum temperature and arrival time according to the difference in air volume. In the internal temperature distribution results for the PP fiber mixing amount of 0.75, 1.0, 1.5, and 2.0 kg/m3, the results of 0.75 and 1.0 kg/m3 showed similar temperature distribution, and the results of 1.5 and 2.0 kg/m3 were similar. It was confirmed that the internal temperature distribution tends to decrease at the same depth when the amount of PP fiber mixed is large, and it was confirmed that a remarkable difference occurred from the results of 1.0 kg/m3 and 1.5 kg/m3 of PP fiber mixed amounts.

An Analysis of the Current Status and Characteristics of Airborne Fungi in Indoor Air in Multi-Use Facilities Nationwide (전국 다중이용시설의 실내공기 부유 곰팡이의 현황 및 특성 분석)

  • Park, Yongsung;Kwon, Soonhyun;Park, Song-Yi;Kee, Sun-Ho;Yoon, Wonsuck
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.5
    • /
    • pp.282-289
    • /
    • 2022
  • Background: Airborne fungi are ubiquitous in the air and exposure to an airborne fungus can be a significant risk factor. The composition of fungi has been potentially important for human health, especially for respiratory diseases like asthma and atopic dermatitis. Therefore, we attempted to ascertain what kind of airborne fungi affect human health at a nationwide level. Objectives: This study was carried out to provide information on indoor fungi distribution at multi-use facilities throughout South Korea. Methods: We classified our data by region and public facility after collection, cultivation, and identification via the sequencing of the ITS (internal transcribed spacer) region. We investigated whether or not the proliferation of HaCaT cells was affected by the identified airborne fungi. Results: In our data, the most isolated airborne fungi by region were Penicillium spp (Seoul, Daegu), Periconia sp (Gyeonggi-do), Iprex sp (Gangwon-do), Phanerochaete sp (Busan), Bjerkandera sp (Gwangju), and Aspergillus sp (Jeju-do). In the public facilities, the most detected fungi were Cladosporium sp (public transport), Penicillium sp (apartment house, retail market, financial institution, karaoke room), Bjerokandera sp (underground parking lot, public toilet, medical institution), Periconia sp (retail store), and Fusarium sp (general restaurant). Next, we selected twenty airborne fungi to examine their cytotoxicity and proliferation of human skin cells. In this experiment, the proliferation of the cells was influenced by most of the identified fungi. In case of the cytotoxicity test, most genera except for Rhodotorula sp and Moesziomyces sp showed cytotoxicity in HaCaT cells. Conclusions: The distribution of mold in the indoor air in multi-use facilities in South Korea differs from region to region, and this is an indicator that should be considered in future health impact studies. In addition, as a result of culturing about 20 types of bacteria dominant in indoor air, it was found that most (90%) inhibit the growth of skin cells, which can be harmful to health. An in-depth study of the health effects of floating fungi is needed.

Variation of Earth Pressure Acting on Cut-and-Cover Tunnel Lining with Settlement of Backfill (되메움토의 침하에 따른 개착식 터널 라이닝에 작용하는 토압의 변화)

  • Bautista F.E.;Park Lee-Keun;Im Jong-Chul;Lee Young-Nam
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.6
    • /
    • pp.27-40
    • /
    • 2006
  • Damage of cut-and-cover tunnel lining can be attributed to physical and mechanical factors. Physical factors include material property, reinforcement corrosion, etc. while mechanical factors include underground water pressure, vehicle loads, etc. This study is limited to the modeling of rigid circular cut and cover tunnel constructed at a depth of $1.0{\sim}1.5D$ in loose sandy ground and subjected to a vibration frequency of 100 Hz. In this study, only damages due to mechanical factors in the form of additional loads were considered. Among the different types of additional, excessive earth pressure acting on the cut-and-cover tunnel lining is considered as one of the major factors that induce deformation and damage of tunnels after the construction is completed. Excessive earth pressure may be attributed to insufficient compaction, consolidation due to self-weight of backfill soil, precipitation and vibration caused by traffic. Laboratory tunnel model tests were performed in order to determine the earth pressure acting on the tunnel lining and to investigate the applicability of existing earth pressure formulas. Based on the difference in the monitored and computed earth pressure, a factor of safety was recommended. Soil deformation mechanism around the tunnel was also presented using the picture analysis method.

Review on Rock-Mechanical Models and Numerical Analyses for the Evaluation on Mechanical Stability of Rockmass as a Natural Barriar (천연방벽 장기 안정성 평가를 위한 암반역학적 모델 고찰 및 수치해석 검토)

  • Myung Kyu Song;Tae Young Ko;Sean S. W., Lee;Kunchai Lee;Byungchan Kim;Jaehoon Jung;Yongjin Shin
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.445-471
    • /
    • 2023
  • Long-term safety over millennia is the top priority consideration in the construction of disposal sites. However, ensuring the mechanical stability of deep geological repositories for spent fuel, a.k.a. radwaste, disposal during construction and operation is also crucial for safe operation of the repository. Imposing restrictions or limitations on tunnel support and lining materials such as shotcrete, concrete, grouting, which might compromise the sealing performance of backfill and buffer materials which are essential elements for the long-term safety of disposal sites, presents a highly challenging task for rock engineers and tunnelling experts. In this study, as part of an extensive exploration to aid in the proper selection of disposal sites, the anticipation of constructing a deep geological repository at a depth of 500 meters in an unknown state has been carried out. Through a review of 2D and 3D numerical analyses, the study aimed to explore the range of properties that ensure stability. Preliminary findings identified the potential range of rock properties that secure the stability of central and disposal tunnels, while the stability of the vertical tunnel network was confirmed through 3D analysis, outlining fundamental rock conditions necessary for the construction of disposal sites.

Analysis of Infrared Characteristics According to Common Depth Using RP Images Converted into Numerical Data (수치 데이터로 변환된 RP 이미지를 활용하여 공동 깊이에 따른 적외선 특성 분석)

  • Jang, Byeong-Su;Kim, YoungSeok;Kim, Sewon;Choi, Hyun-Jun;Yoon, Hyung-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.3
    • /
    • pp.77-84
    • /
    • 2024
  • Aging and damaged underground utilities cause cavity and ground subsidence under roads, which can cause economic losses and risk user safety. This study used infrared cameras to assess the thermal characteristics of such cavities and evaluate their reliability using a CNN algorithm. PVC pipes were embedded at various depths in a test site measuring 400 cm × 50 cm × 40 cm. Concrete blocks were used to simulate road surfaces, and measurements were taken from 4 PM to noon the following day. The initial temperatures measured by the infrared camera were 43.7℃, 43.8℃, and 41.9℃, reflecting atmospheric temperature changes during the measurement period. The RP algorithm generates images in four resolutions, i.e., 10,000 × 10,000, 2,000 × 2,000, 1,000 × 1,000, and 100 × 100 pixels. The accuracy of the CNN model using RP images as input was 99%, 97%, 98%, and 96%, respectively. These results represent a considerable improvement over the 73% accuracy obtained using time-series images, with an improvement greater than 20% when using the RP algorithm-based inputs.

Preliminary Study on Candidate Host Rocks for Deep Geological Disposal of HLW Based on Deep Geological Characteristics (국내 심부 지질특성 연구를 통한 고준위방사성폐기물 심층처분 후보 암종 선행연구)

  • Dae-Sung Cheon;Kwangmin Jin;Joong Ho Synn;You Hong Kihm;Seokwon Jeon
    • Tunnel and Underground Space
    • /
    • v.34 no.1
    • /
    • pp.28-53
    • /
    • 2024
  • In general, high-level radioactive waste (HLW) generated as a result of nuclear power generation should be disposed within the country. Determination of the disposal site and host rock for HLW deep geological repository is an important issue not only scientifically but also politically, economically, and socially. Considered host rock types worldwide for geological disposal include crystalline rocks, sedimentary rocks, volcanic rocks, and salt dome. However, South Korea consists of various rock types except salt dome. This paper not only analyzed the geological and rock mechanical characteristics on a nationwide scale with the preliminary results on various rock type studies for the disposal host rock, but also reviewed the characteristics and possibility of various rock types as a host rock through deep drilling surveys. Based on the nationwide screening for host rock types resulted from literature review, rock distributions, and detailed case studies, Jurassic granites and Cretaceous sedimentary rocks (Jinju and Jindong formations) were derived as a possible candidate host rock types for the geological disposal. However, since the analyzed data for candidate rock types from this study is not enough, it is suggested that the disposal rock type should be carefully determined from additional and detailed analysis on disposal depth, regional characteristics, multidisciplinary investigations, etc.

Preliminary Study on the Jinju Formation in the Gyeongsang Basin to Evaluate Host Rock for High-level Radioactive Waste Geological Disposal: Focusing on Lithological and Mineralogical Characteristics (고준위방사성폐기물 지층처분 암종 평가를 위한 경상분지 진주층 예비연구: 암상 및 광물학적 특성을 중심으로)

  • Sung Kyung Hong;Kwangmin Jin
    • Economic and Environmental Geology
    • /
    • v.57 no.4
    • /
    • pp.387-396
    • /
    • 2024
  • The geological disposal of high-level radioactive waste (HLW) involves permanently isolating the wastes in stable geological formations deep underground. Mudstone (siltstone and claystone) containing abundant clay minerals is proposed as a host rock for geological disposal of HLW because clay minerals have low permeability and high ion sorption/exchange capacity. Despite the widespread occurrence of sedimentary basins in Korea, there is a lack of evaluation of mudstone as host rocks for geological disposal. In this study, we utilized the JBH-1 borehole (7-754 m) obtained from the Jinju Formation to investigate the distribution trend and mineral compositions of mudstone. Additionally, we conducted comparative analyses with the Opalinus Clay in Switzerland considered as host rock of geological disposal of HLW. Claystone containing more than 40% clay minerals exhibit thick layers primarily in the upper section (7-350 m) of the JBH-1 borehole. While the clay minerals content of claystone does not show significant variation with depth, there are differences in the characteristics of feldspar and carbonate minerals. These mineralogical variations can led change in pore water chemistry and rock mechanical properties. The clay minerals content of claystone in the Jinju Formation is similar to that of the Opalinus Clay. However, there are notable differences in clay minerals composition. While the Opalinus Clay contains smectite-illite mixed-layer minerals, the Jinju Formation are dominated by illite indicating higher burial temperatures. This information will be useful for studying the host rock of HLW geological disposal site in Korea.