• Title/Summary/Keyword: under-break

Search Result 451, Processing Time 0.023 seconds

Effect of Night-break Treatment on Growth and Flowering of Orostachys japonicus A. Berger (암기중단 처리시기가 바위솔의 생장과 개화에 미치는 영향)

  • Lee, Chang-Woo;Jeon, Seung-Ho;Kim, Hong-Young;Shin, Sung-Cheol;Kang, Jin-Ho
    • Korean Journal of Medicinal Crop Science
    • /
    • v.15 no.4
    • /
    • pp.256-260
    • /
    • 2007
  • Year-round cultivation of a monocarpic plant Orostachys japonicus should be possible in case to controlling floret flowering. To give some information on its year-round cultivation, this study was carried out to examine the effect of night-break treatment time (June 10, Aug. 25) on its growth, morphological characters, and flowering. Night-break treatment of 2 hours at midnight were done since Aug. 25 and heating were made under $20^{\circ}C$ Samples were taken every 4 weeks from Aug. 25. Growth, morphological and flowering related characters were measured from each sample until March 9. Plant height, inflorescence length, number of leaves including bracts and stem diameter were greater in the earlier treatment than in the later one. Leaves and bracts, floret, stem, root, shoot and total dry weights showed the same response as plant height did to the night-break treatment time. Florets were more formed in the earlier treatment than in the later treatment in which they were flowered only on March 9, meaning that its year-round cultivation should be possible under night-break treatment before bolting and heating during winter season.

Estimation of Willingness-to-pay for Rehabilitation and Upgrading of Reservoirs in Protecting Against Natural Disasters and Dam-Break (재해·재난 예방을 위한 저수지개보수사업의 지불의사금액 추정)

  • Park, Sung Kyung;Lim, Cheong Ryong;Han, Jae Hwan;Chung, Won Ho
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.139-153
    • /
    • 2018
  • This study analyzes the economic effect of rehabilitation and upgrading of reservoirs as a prevented method against natural disasters under recent abnormal weather conditions and dam-break. For the analysis, we divide the purpose of rehabilitation and upgrading of reservoirs into the stable supply of rural water under uncertain weather conditions and the prevention of collapse due to the aging of the reservoir. We measure the economic effect of rehabilitation and upgrading of reservoirs by estimating the resident's willingness-to-pay for the project through Contingent Valuation Method(CVM). The result shows that distributions of willingness-to-pay to prevent natural disasters and dam-break are similar to each other. About 66% of the residents in sample regions are willing to pay for the project. The resident's willingness-to-pay to protect natural disasters and dam-break are 32,250 to 46,147 won and 28,427 to 47,308 won respectively on average for all sample regions. The comparison of willingness-to-pay by type of regions shows that paddy field areas are the highest followed by facility cultivation areas and urban areas. In addition, total expected value of the projects calculated based on the resident's willingness-to-pay for paddy field areas and facility cultivation areas are much larger than actual project costs. This implies that rural residents are fully aware of the importance of the project to prevent natural disasters and dam-break and are willing to pay for additional costs if needed.

Assessment of the core-catcher in the VVER-1000 reactor containment under various severe accidents

  • Farhad Salari;Ataollah Rabiee;Farshad Faghihi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.144-155
    • /
    • 2023
  • The core catcher is used as a passive safety system in new generation nuclear power plants to create a space in the containment for the placing and cooling of the molten corium under various severe accidents. This research investigates the role of the core catcher in the VVER-1000 reactor containment system in mitigating the effects of core meltdown under various severe accidents within the context of the Ex-vessel Melt Retention (EVMR) strategy. Hence, a comparison study of three severe accidents is conducted, including Station Black-Out (SBO), SBO combined with the Large Break Loss of Coolant Accident (LB-LOCA), and SBO combined with the Small Break Loss of Coolant Accident (SB-LOCA). Numerical comparative simulations are performed for the aforementioned scenario with and without the EX-vessel core-catcher. The results showed that considering the EX-Vessel core catcher reduces the amount of hydrogen by about 18.2 percent in the case of SBO + LB-LOCA, and hydrogen production decreases by 12.4 percent in the case of SBO + SB-LOCA. Furthermore, in the presence of an EX-Vessel core-catcher, the production of gases such as CO and CO2 for the SBO accident is negligible. It was revealed that the greatest decrease in pressure and temperature of the containment is related to the SBO accident.

Improving the Performance of L3 Handover Mobility Management in Heterogeneous Wireless Network (이종 무선망에서 L3 핸드오버 이동성 관리 성능 향상)

  • Hong, Sung-Back;Lee, Kyeong-Ho;Kim, Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6B
    • /
    • pp.382-389
    • /
    • 2007
  • In this paper we report the development of mobility test bed, the realization of basic protocol that supports L3 mobility and the measurement of performance parameters that can affect handover performance. Previously proposed mobility management system, BBM (Break Before Make) method such as MIPV6 and Fast MIPV6, uses one interface in wireless network. In this method, to connect to new AP, it first disconnects existing AP and tries to connect to new AP. This can cause packet loss for the traffic vulnerable to delay such as VoIP. To provide seamless handover between different wireless networks, we propose MBB (Make Before Break) handover method having two network interfaces. Comparative study of previous method and proposed method on mobility and handover was conducted under simulated real environment on the test bed. Almost no packet loss was found with newly proposed method. In conclusion, it is shown that mobility protocol with proposed handover method can be applied to the application services sensitive to delay and packet loss.

Discharge Equation Related to a Levee-Break for a Flood Hazard Map (홍수위험지도 작성을 위한 하천 제방 붕괴 유량공식 제안)

  • Lee, Khil-Ha;Kim, Sung-Wook;Choi, Bong-Hyuck
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.623-627
    • /
    • 2015
  • To compile a flood hazard map it is essential to identify the potential risk areas. A scenario-based numerical modeling approach is commonly used to build a flood hazard map in the case of a levee-break. The model parameters that capture peak discharge, including breach formation and progress, are important in the modeling method. In this study an earth-levee-break model is constructed under the assumption that the failure mechanism and hydraulic processes are identical for all levee-break river activities. Estimation of the hydrograph at the outlet as a function of time is highlighted. The constructed hydrograph can then serve as an upper boundary condition in running the flood routing model downstream, although flood routing is not considered in this study.

A Break-Even Analysis that Helps with Decision Making involving the Introduction of Ultrasonography (초음파기기 도입 시 의사결정 지원을 위한 손익 분석)

  • Yeo, Seong-Hee;Lee, Hae-Jong;Seo, Young-Joon;Kim, Young-Hoon
    • Korea Journal of Hospital Management
    • /
    • v.14 no.3
    • /
    • pp.23-48
    • /
    • 2009
  • The purpose of this study was to provide criteria which help executives to make decisions through the analysis of profitability of ultrasonography conducted in each medical department. In order to achieve such purpose, the study conducted break-even analyses on three medical departments of a university hospital in which has used ultrasonography was largely conducted in diagnosing diseases and performing surgeries. The research was carried out from January to June 2008. The data necessary for calculating cost, were collected using by computerized data. The results of the study were summarized as follows. 1. The Cost structure of each medical department: The Cost of ultrasonography was divided into direct cost and indirect cost through the categorization by cost object. Labor cost accounted for the largest portion of the direct cost with 69.3% in the department of obstetrics and gynecology, 67.4% in the department of radiology and 58.2% in the cardiac ultrasonography center, which followed by the depreciation cost of ultrasonography equipment. The calculation of the average material cost of each ultrasonographic test by medical test found that the cardiac ultrasonography center took first place with 2,355 won, followed by the department of obstetrics and gynecology with 266 won and the department of radiology with 233 won. As for the power cost of ultrasonography equipment, the department of radiology took fist place with 442,000 won. The power cost, however, did not affect much the cost price, because it accounted for only a small portion of the cost. As for indirect cost, the cardiac ultrasonography center ranked first with 7,156,000 won. Building depreciation cost accounted for the largest portion of the indirect cost. 2. Break-even analysis: Under the supposition that cost price can be divided into fixed cost and variable cost, a break-even analysis was conducted using the cost price confirmed through the cost structure of each medical department. As for the average customary charge of ultrasonography test conducted in each medical department, the department of obstetrics and gynecology charged 24,627 won, the department of radiology 53,179 won and the cardiac ultrasonography center 65,174 won. According to these results, the charges of ultrasonography test imposed by the department of radiology and the cardiac ultrasonography center wre enough to surpass break-even levels, but the charge imposed by the department of obstetrics and gynecology was not enough to offset the cost price. In conclusion, labor cost accounted for the largest proportion of cost price of ultrasonography test conducted in diagnosing diseases and performing surgeries in medical departments, followed by the fixed cost of ultrasonographic equipment depreciation cost. In medical department where the current charge of ultrasonography test turned out not to offset cost price through the break-even analysis of ultrasonographic equipment, ways to reduce fixed cost which accounts for the largest proportion of the cost price should be sought. Even medical departments whose current charge of ultrasonography test is enough to surpass break-even level are required to work for efficient management and cost reduction to continuously generate profits.

  • PDF

Leak-Before-Break Behavior and Crack Opening Displacement in Piping Under Bending Load (굽힘하중을 받는 배관의 파단전누설거동 및 균열개구변위)

  • Nam, Ki-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.725-730
    • /
    • 2010
  • The leak-before-break behavior and the crack opening displacement were investigated of statically indeterminate piping system and statically determinate piping system after a crack penetration. The reduction in the ultimate strength caused by a crack was relatively small in the statically indeterminate piping system. The leak-before-break in the statically indeterminate piping system had a larger safety margin than that in the statically determinate piping system. The crack opening displacement after crack penetration in a pipe with a nonpenetrating crack was evaluated by using a plastic rotation angle.

Dependency of the Critical Carbon Content of Electrical Conductivity for Carbon Powder-Filled Polymer Matrix Composites

  • Shin, Soon-Gi
    • Korean Journal of Materials Research
    • /
    • v.25 no.8
    • /
    • pp.365-369
    • /
    • 2015
  • This paper investigates the dependency of the critical content for electrical conductivity of carbon powder-filled polymer matrix composites with different matrixes as a function of the carbon powder content (volume fraction) to find the break point of the relationships between the carbon powder content and the electrical conductivity. The electrical conductivity jumps by as much as ten orders of magnitude at the break point. The critical carbon powder content corresponding to the break point in electrical conductivity varies according to the matrix species and tends to increase with an increase in the surface tension of the matrix. In order to explain the dependency of the critical carbon content on the matrix species, a simple equation (${V_c}^*=[1+ 3({{\gamma}_c}^{1/2}-{{\gamma}_m}^{1/2})^2/({\Delta}q_cR]^{-1}$) was derived under some assumptions, the most important of which was that when the interfacial excess energy introduced by particles of carbon powder into the matrix reaches a universal value (${\Delta}q_c$), the particles of carbon powder begin to coagulate so as to avoid any further increase in the energy and to form networks that facilitate electrical conduction. The equation well explains the dependency through surface tension, surface tensions between the particles of carbon powder.

Numerical and analytical predictions of nuclear steam generator secondary side flow field during blowdown due to a feedwater line break

  • Jo, Jong Chull;Jeong, Jae-Jun;Moody, Frederick J.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.1029-1040
    • /
    • 2021
  • For the structural integrity evaluation of pressurized water reactor (PWR) steam generator (SG) tubes subjected to transient hydraulic loading, determination of the tube-to-tube gap velocity and static pressure distributions along the tubes is prerequisite. This paper addresses both computational fluid dynamics (CFD) and analytical approaches for predicting the tube-to-tube gap velocity and static pressure distributions during blowdown following a feedwater line break (FWLB) accident at a PWR SG. First of all, a comparative study on CFD calculations of the transient velocity and pressure distributions in the SG secondary sides for two different models having 30 or no tubes is performed. The result shows that the velocities of sub-cooled water flowing between any adjacent two tubes of a tubed SG model during blowdown can be roughly estimated by applying the specified SG secondary side porosity to those of the no-tubed SG model. Secondly, simplified analytical approximate solutions for the steady two-dimensional SG secondary flow velocity and pressure distributions under a given discharge flowrate are derived using a line sink model. The simplified analytical solutions are validated by comparing them to the CFD calculations.

Development and Validation of MARS-KS Input Model for SBLOCA Using PHWR Test Facility (중수로 실증 실험설비를 이용한 소형냉각재상실사고의 MARS-KS 입력모델 개발 및 검증계산)

  • Baek, Kyung Lok;Yu, Seon Oh
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.111-119
    • /
    • 2021
  • Multi-dimensional analysis of reactor safety-KINS standard (MARS-KS) is a thermal-hydraulic code to simulate multiple design basis accidents in reactors. The code has been essential to assess nuclear safety, but has mainly focused on light water reactors, which are in the majority in South Korea. Few previous studies considered pressurized heavy water reactor (PHWR) applications. To verify the code applicability for PHWRs, it is necessary to develop MARS-KS input decks under various transient conditions. This study proposes an input model to simulate small-break loss of coolant accidents for PHWRs. The input model includes major equipment and experimental conditions for test B9802. Calculation results for selected variables during steady-state closely follow test data within ±4%. We adopted the Henry-Fauske model to simulate break flow, with coefficients having similar trends to integrated break mass and trip time for the power supply. Transient calculation results for major thermal-hydraulic factors showed good agreement with experimental data, but further study is required to analyze heat transfer and void condensation inside steam generator u-tubes.