• 제목/요약/키워드: unbalanced load

검색결과 284건 처리시간 0.021초

Enhanced Proportional-Resonant Current Controller for Unbalanced Stand-alone DFIG-based Wind Turbines

  • Phan, Van-Tung;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.443-450
    • /
    • 2010
  • An enhanced control strategy for variable-speed unbalanced stand-alone doubly-fed induction generator-based wind energy conversion systems is proposed in this paper. The control scheme is applied to the rotor-side converter to eliminate stator voltage imbalance. The proposed current controller is developed based on the proportional-resonant regulator, which is implemented in the stator stationary reference frame. The resonant controller is tuned at the stator synchronous frequency to achieve zero steady-state errors in rotor currents without decomposing the positive and negative sequence components. The computational complexity of the proposed control algorithm is greatly simplified, and control performance is significantly improved. Finally, simulations and experimental results are presented to verify the feasibility and the robustness of the proposed control scheme.

불평형 배전계통에 있어서 유전알고리즘을 이용한 커패시터의 적정 배치 및 제어 (Optimal Capacitor Placement and Control using Genetic Algorithms in Unbalanced Distribution Systems.)

  • 김규호;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.839-846
    • /
    • 1999
  • This paper presents an efficient algorithm for determining the location, size and number of capacitors in unbalanced radial distribution system. The objective function formulated consists of two terms: cost for energy loss and cost related to capacitor purchase and capacitor installation. The cost function associated with capacitor placement is considered as step function due to banks of standard discrete capacities. Genetic algorithms(GA) are used to obtain the population is derived. The strings in each population consist of the bus number index and size of capacitors to be installed. In order to determine the number of capacitor placement, the length mutation operator is used. Its efficiency is proved through the application in unbalanced radial distribution systems made of 10 buses with 9 distribution lines and 25 buses with 24 distribution lines.

  • PDF

전기철도 시스템의 불평형 해석 (Analysis of Voltage Unbalance on Electric Railway System)

  • 이한민;김길동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.184-190
    • /
    • 2005
  • The railway characteristic, which is concerned, as most utilities is unbalance produced by the large single-phase loads. Here are two theoretical concerns associated with unbalanced loads. First, generator rotor heating resulting from unbalanced current flow, Second, there is the possibility of motor overheating in industrial plants, due to the unbalanced voltage. Therefore, the exact assessment of the voltage unbalance must be carried out preferentially as well as load forecast at stages of designing and planning for the electric railway system. This paper proposes a new analysis model to more effectively estimate voltage unbalance. Numerous distributed circuits in the electric railway system are composed by components. The entire system can be easily modeled by the combination of four-port representation of each component in parallel and/or series. Simulation results using the model are compared with field data, and it verifies the accuracy of the proposed model.

  • PDF

배전용 정지형 보상기의 상태관측기를 이용한 순시 유효/무효전력 보상 (Instantaneous Active/Reactive Power Compensation of Distribution Static Compensator using State Observer)

  • 김형수;최종우
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1377-1382
    • /
    • 2008
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensation current and the other part is the current control. Conventional researches use a LPF(low pass filter) to eliminate ripple component at the calculation of compensation current. But this method has a problem that LPF's characteristics restrict the compensation performance of instantaneous active and reactive power. This paper proposes a calculation of compensation current using state observer that can be a counterproposal of conventional methods using LPF. Improved performance of instantaneous active and reactive power compensation was shown by experiments.

Phase Shift Analysis and Phase Identification for Distribution System with 3-Phase Unbalanced Constant Current Loads

  • Byun, Hee-Jung;Shon, Sugoog
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.729-736
    • /
    • 2013
  • Power grids are large complicated networks in use around. An absolute phase value for a particular unknown-phase line at a local site should be identified for the operation and management of a 3-phase distribution network. The phase shift for a specific point in the line, as compared with a phase reference point at a substation, must be within a range of ${\pm}60^{\circ}$ for correct identification. However, the phase shift at a particular point can fluctuate depending on the line constants, transformer wiring method, line length, and line amperage, etc. Conducted in this study is a theoretical formulation for the determination of phase at a specific point in the line, Simulink modeling, and analysis for a distribution network. In particular, through evaluating the effects of unbalanced current loads, the limitations of the present phase identification methods are described.

An Effective Rotor Current Controller for Unbalanced Stand-Alone DFIG Systems in the Rotor Reference Frame

  • Phan, Van-Tung;Lee, Hong-Hee;Chu, Tae-Won
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.724-732
    • /
    • 2010
  • This paper presents an effective rotor current controller for variable-speed stand-alone doubly fed induction generator (DFIG) systems feeding an unbalanced three-phase load. The proposed current controller is developed based on proportional plus two resonant regulators, which are tuned at the positive and negative slip frequencies and implemented in the rotor reference frame without decomposing the positive and negative sequence components of the measured rotor current. In addition, the behavior of the proposed controller is examined in terms of control performance and stability with respect to rotor speed variations, i.e., slip frequency variations. Simulations and experimental results are shown to validate the robustness and effectiveness of the proposed control method.

3상 4선식 전력 시스템의 중성선 전류 분석 (Neutral Line Current Analysis of Three-phase Four-wire Power System)

  • 민준기;김형철;김수철;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.492-494
    • /
    • 2006
  • Neutral line current is analyzed by the neutral line CF in nonlinear load balanced and unbalanced conditions. The worst nonlinear load condition is nonlinear balanced load condition, and It is below CFNL=1.194 that a neutral line current could not excess the rated value

  • PDF

불균형 휨모멘트를 받는 플랫 플레이트-기둥 외부접합부의 강도 (Strength of Exterior Flat Plate-Column Connections Subjected to Unbalanced Moment)

  • 최경규;박홍근
    • 콘크리트학회논문집
    • /
    • 제15권3호
    • /
    • pp.470-481
    • /
    • 2003
  • 플랫 플레이트 구조의 외부접합부는 편심전단에 대해 비대칭형의 위험단면을 가지고 있으며, 위험단면의 길이가 내부접합부 보다 작고 중력하중과 횡하중 모두에 의해 편심전단응력이 발생하게 되므로 뚫림전단파괴에 대해 대단히 취약하다. 외부접합부의 거동은 대단히 복잡하며 또한 구조해석에서 사용하고 있는 강도모델이 부적합하기 때문에, 현 설계기준은 실험결과를 정확히 설명하고 있지 못하다. 본 연구에서는 이러한 현 설계기준의 미비점을 보완하기 위하여 슬래브-기둥 외부접합부에 대해 비선형유한요소해석을 수행하였다. 외부접합부에서는 횡하중의 재하방향에 따라 거동 및 최대강도가 상이하며, 해석결과에 근거하여 하중재하방향 별로 외부접합부에 대한 강도모델을 제안하였다. 제안된 강도모델은 실험결과와의 비교를 통해 검증되었다.

퍼지이론을 이용한 3상 2회선 불평형 송전선로에서의 전자계에 대한 인체 위험 가능성평가 (Assessment of Possibility on the Human Risk for the Electromagnetic Field of Unbalanced Two Coupled Three-phase Transmission Line Using Fuzzy Theory)

  • 김상철;김두현
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.22-28
    • /
    • 2006
  • This paper presents assessment of possibility on the human risk for the electromagnetic field of unbalanced two coupled three-phase transmission line using fuzzy theory. Three phase load flow program was developed which employed a Newton-Raphson method as a tool to analyze system unbalanced. This research presents a method of handling two coupled three phase transmission system unbalance analysis and unbalanced power demand as a function of voltages. As the results of case study, in case of 345[kV] T/L, the electric field intensity was 10.9540[kV/m], magnetic field intensity was 0.2567[G] in severest case. The results showed that the membership of a proposition fuzzy '10.9540 [kV/m] is hazardous' is 0.6349. As the analytic results using the fuzzy qualifier term, the membership in case of very false is 0.1379 and fairly false is 0.6124, respectively. In assessment of fuzzy measure possibility for the electromagnetic field, this paper used probability of fuzzy arid measure of fuzziness technique.

Multi-objective Unbalanced Distribution Network Reconfiguration through Hybrid Heuristic Algorithm

  • Mahendran, G.;Sathiskumar, M.;Thiruvenkadam, S.;Lakshminarasimman, L.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.215-222
    • /
    • 2013
  • Electrical power distribution systems are critical links between the utility and customer. In general, power distribution systems have unbalanced feeders due to the unbalanced loading. The devices that dependent on balanced three phase supply are affected by the unbalanced feeders. This necessitates the balancing of feeders. The main objective of reconfiguration is to balance the loads among the phases subject to constraints such as load flow equations, capacity and voltage constraints and to reduce the real power loss, while subject to a radial network structure in which all loads must be energized. Therefore, the distribution system reconfiguration problem has been viewed as multi-objective problem. In this paper, the hybrid heuristic algorithm has been used for reconfiguration, which is the combination of fuzzy and greedy algorithms. The purpose of the introduction of greedy is to refrain the searching for the period of phase balancing. The incorporation of fuzzy helps to take up more objectives amid phase balancing in the searching. The effectiveness of the proposed method is demonstrated through modified IEEE 33 bus and modified IEEE 125 bus radial distribution system.