• 제목/요약/키워드: unbalance supply voltage

검색결과 39건 처리시간 0.038초

강성 회전축계를 지지한 ER-SFD의 parametric study 및 최적설계 (A Parametric Study and an Optimal Design of an ER-SFD Supporting a Rigid Rotor System)

  • 김종립;이남수;이용복;김창호;최동훈
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.279-284
    • /
    • 1999
  • This paper presents a parametric study and an optimal design of the ER-SFD supporting a rigid rotor system. An attempt is made to obtain the optimal design of an ER-SFD for a two degree-of-freedom rotor model. Such a simple model is used in order to get a better insight into the physics of the problem, A maximum whirl amplitude, supply pressure and voltage are considered, and a maximum whirl amplitude is minimized over a range of speeds and presented for some values of unbalance mass. The results presented in this paper provide important design information necessary to reduce a whirl amplitude of an ER-SFD.

  • PDF

능동 다중인터페이스 리액터와 Double PLL제어를 이용한 Modular UPS 설계 (A Modular UPS Design with an Active Multiple Interphase Reactor and Double PLL Control)

  • 박인덕;정상식;안형회;김시경
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.489-497
    • /
    • 2001
  • 병렬로 구성되 UPS 사이에 파라미터 불일치에 따른 순환전류와 전압리플이 발생되어지는데, 이들은 전체 UPS 시스템의 고장 및 신뢰성 저하를 유발한다. 본 논문에서는 이러한 문제점들은 Double 위상동동기기와 능동 다중인 터페이스 리액터를 사용하여 해결하였다. 또한 ADSP21061을 사용하여 제어기를 디지털적으로 구현하였다.

  • PDF

넓은 영전압 스위칭 범위를 갖는 새로운 고효율 DC/DC 컨버터 (A New High Efficiency DC/DC Converter with Wide ZVS Range)

  • 박기범;김정은;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.364-368
    • /
    • 2004
  • A new high efficiency DC/DC converter is proposed, which is derived from the conventional half-bridge converter. The proposed converter has good ZVS condition compared with the conventional half-bridge converter, and shows a high efficiency by solving the unbalance voltage stress and current stress problem of secondary rectifier diode of the conventional half-bridge converter. In this paper, the basic operations of the proposed converter is analyzed compared with that of the conventional half-bridge converter, and the excellent performance of the proposed converter is verified by the experimental results with the 42W prototype of the power supply for PDP Sustain Driver.

  • PDF

강성 회전축계를 지지한 전기 유변 유체 스퀴즈 필름 댐퍼의 최적설계 (An Optimal Design of an ER-SFD Supporting a Rigid Rotor System)

  • 이용복;김종립;이남수;김창호;최동훈
    • Tribology and Lubricants
    • /
    • 제17권3호
    • /
    • pp.216-220
    • /
    • 2001
  • This paper presents a parametric study and an optimal design of the ER-SFD supporting a rigid rotor system. An attempt is made to obtain the optimal design of an ER-SFD for a two degree-of-freedom rotor model. Such a simple model is used in order to get a better insight into the physics of the problem. A maximum whirl amplitude, supply pressure and voltage are considered, and a maximum whirl amplitude is minimized over a range of speeds and presented f3r some values of unbalance mass. The results presented in this paper provide important design information necessary to reduce a whirl amplitude of an ER-SFD.

농어촌 동력용 전동기구를 위한 단상/3상변환기의 개발에 관한 연구 (Study on single/three phase converter for motor applications of rural district)

  • 황영문;조철제
    • 전기의세계
    • /
    • 제25권4호
    • /
    • pp.68-72
    • /
    • 1976
  • This study is initiated to solve the problem that the development of an electric machine to drive heavy horse-power load required in the rural district, where only single phase supply is available, is very urgent. As a method for this purpose, the single/three phase converter by single phase induction machine with a tapped auxiliary winding, running unloaded mechanically under single-phase source and supplying three-phase output to a loaded 3-phase induction motor, is devised and the pilot machine is put into test. Analysis based on hybrid equivalent circuit for the phase converter and symmertical component theory for the 3-phase load motor and practical experiment result in that optimum auxiliary winding ratio is to be 1.25 rather than theoretical .root.3/2 in order to keep the voltage unbalance ratio of 3-phase output from the converter as low as possible in both cases of starting and running the load motor.

  • PDF

리튬-이온 배터리 시스템을 위한 전압안정화 회로 (Voltage Balancing Circuit for Li-ion Battery System)

  • 박경화;이강현
    • 한국산업정보학회논문지
    • /
    • 제18권5호
    • /
    • pp.73-80
    • /
    • 2013
  • 최근 인공위성의 에너지 저장 매체로서 리튬-이온 배터리가 각광을 받는 추세이다. 리튬-이온 배터리는 다른 화학적 특성을 가지는 배터리들에 비해 높은 작동 전압과 큰 용량을 가지면서 부피도 작기 때문에 위성의 eclipse 기간 동안 위성에 전력을 공급하는 데에 매우 효과적이다. 위성에 전력을 공급하기 위한 에너지 저장 장치로서 리튬-이온 배터리를 사용하기 위해서는 하나의 cell이 아닌 다중 cell을 직렬 연결해서 사용해야 한다. 그러나 cell 간의 미소한 내부저항 차이 때문에 cell 전압의 언밸런스 (Unbalance)가 야기되고 충전 시 저항이 낮은 cell이 과 충전 되어 전지 용량이 급격히 저하되고 이로 인해 배터리의 수명이 줄어들게 된다. 따라서 본 논문에서는 Fly-back topology를 이용하여 다중 cell을 직렬 연결할 때 각 cell간의 전압 편차를 줄여주는 전압안정화 회로를 구현하였으며, prototype 제작 및 시험을 통해 배터리의 전압이 균일해지는 것을 확인하였다.

전력계통 전력품질 통합진단시스템 개발 (The Development of Integrated Power Quality Diagnosis System for Power System)

  • 곽노홍;전영수;박상호;이일무;박희철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

컨버터 병렬운전을 위한 디지털 부하분담 기법 (Digital Load Sharing Method for Converter parallel Operation)

  • 유광민;김원용;박승희;이동후;김윤성;정유석;이준영
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.150-157
    • /
    • 2012
  • This paper presents CAN-based parallel-operation and load-sharing techniques for the communication server power supply. With the load information obtained through CAN communication, each modules performs its current control independently and the power unbalance caused by impedance differences of converter modules can be reduced. In conventional method, slave modules are controlled by master module. On the other hand, the proposed load share algorithm uses the Multi-Master method. Therefore, accurate load sharing can be accomplished by the reference structure of each module's average current. Each converter has two stages and it is separated into PFC, which is responsible for harmonic regulation, and LLC resonant converter, which controls output voltage. To verified the performance of the proposed method, two 2KW prototypes has been implemented and experimented.