• Title/Summary/Keyword: unbalance supply voltage

Search Result 39, Processing Time 0.023 seconds

A Parametric Study and an Optimal Design of an ER-SFD Supporting a Rigid Rotor System (강성 회전축계를 지지한 ER-SFD의 parametric study 및 최적설계)

  • 김종립;이남수;이용복;김창호;최동훈
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.279-284
    • /
    • 1999
  • This paper presents a parametric study and an optimal design of the ER-SFD supporting a rigid rotor system. An attempt is made to obtain the optimal design of an ER-SFD for a two degree-of-freedom rotor model. Such a simple model is used in order to get a better insight into the physics of the problem, A maximum whirl amplitude, supply pressure and voltage are considered, and a maximum whirl amplitude is minimized over a range of speeds and presented for some values of unbalance mass. The results presented in this paper provide important design information necessary to reduce a whirl amplitude of an ER-SFD.

  • PDF

A Modular UPS Design with an Active Multiple Interphase Reactor and Double PLL Control (능동 다중인터페이스 리액터와 Double PLL제어를 이용한 Modular UPS 설계)

  • 박인덕;정상식;안형회;김시경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.489-497
    • /
    • 2001
  • The proposed dobule phase locked loop and active multiple interphase reactor are used to eliminate the circular current and the voltage ripples caused by the system parameter unbalance of parallel connected UPSs. In this paper, digital controller for the dobule PLL and active interphase reactor is implemented with ADSP21061 as an aspect of functional convenience.

  • PDF

A New High Efficiency DC/DC Converter with Wide ZVS Range (넓은 영전압 스위칭 범위를 갖는 새로운 고효율 DC/DC 컨버터)

  • Park Ki-Bum;Kim Chong-Eun;Moon Gun-Woo;Yoon Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.364-368
    • /
    • 2004
  • A new high efficiency DC/DC converter is proposed, which is derived from the conventional half-bridge converter. The proposed converter has good ZVS condition compared with the conventional half-bridge converter, and shows a high efficiency by solving the unbalance voltage stress and current stress problem of secondary rectifier diode of the conventional half-bridge converter. In this paper, the basic operations of the proposed converter is analyzed compared with that of the conventional half-bridge converter, and the excellent performance of the proposed converter is verified by the experimental results with the 42W prototype of the power supply for PDP Sustain Driver.

  • PDF

An Optimal Design of an ER-SFD Supporting a Rigid Rotor System (강성 회전축계를 지지한 전기 유변 유체 스퀴즈 필름 댐퍼의 최적설계)

  • 이용복;김종립;이남수;김창호;최동훈
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.216-220
    • /
    • 2001
  • This paper presents a parametric study and an optimal design of the ER-SFD supporting a rigid rotor system. An attempt is made to obtain the optimal design of an ER-SFD for a two degree-of-freedom rotor model. Such a simple model is used in order to get a better insight into the physics of the problem. A maximum whirl amplitude, supply pressure and voltage are considered, and a maximum whirl amplitude is minimized over a range of speeds and presented f3r some values of unbalance mass. The results presented in this paper provide important design information necessary to reduce a whirl amplitude of an ER-SFD.

Study on single/three phase converter for motor applications of rural district (농어촌 동력용 전동기구를 위한 단상/3상변환기의 개발에 관한 연구)

  • 황영문;조철제
    • 전기의세계
    • /
    • v.25 no.4
    • /
    • pp.68-72
    • /
    • 1976
  • This study is initiated to solve the problem that the development of an electric machine to drive heavy horse-power load required in the rural district, where only single phase supply is available, is very urgent. As a method for this purpose, the single/three phase converter by single phase induction machine with a tapped auxiliary winding, running unloaded mechanically under single-phase source and supplying three-phase output to a loaded 3-phase induction motor, is devised and the pilot machine is put into test. Analysis based on hybrid equivalent circuit for the phase converter and symmertical component theory for the 3-phase load motor and practical experiment result in that optimum auxiliary winding ratio is to be 1.25 rather than theoretical .root.3/2 in order to keep the voltage unbalance ratio of 3-phase output from the converter as low as possible in both cases of starting and running the load motor.

  • PDF

Voltage Balancing Circuit for Li-ion Battery System (리튬-이온 배터리 시스템을 위한 전압안정화 회로)

  • Park, Kyung Hwa;Yi, Kang Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.73-80
    • /
    • 2013
  • Recently, Li-ion battery is regarded as a potential energy storage device in the lime light and it can supply power to the satellite very effectively during eclipse. Because it has better features as high voltage range, large capacity and small volume than any other battery. Generally, multi cells are connected in series to use Li-ion batteries in satellite application. Since the internal resistance of cells is different each other, voltage in some cells can be overcharged or undercharged, so capacity of the cell is reduced and the life of whole battery pack is decreased. Therefore, a voltage balancing circuit with Fly-back converter is proposed and the voltage equalization of each cell is verified the prototype in this paper.

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer (단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

Digital Load Sharing Method for Converter parallel Operation (컨버터 병렬운전을 위한 디지털 부하분담 기법)

  • Yoo, Kwang-Min;Kim, Won-Yong;Park, Seung-Hee;Lee, Dong-Hoo;Kim, Yun-Sung;Jeong, Yu-Seok;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.150-157
    • /
    • 2012
  • This paper presents CAN-based parallel-operation and load-sharing techniques for the communication server power supply. With the load information obtained through CAN communication, each modules performs its current control independently and the power unbalance caused by impedance differences of converter modules can be reduced. In conventional method, slave modules are controlled by master module. On the other hand, the proposed load share algorithm uses the Multi-Master method. Therefore, accurate load sharing can be accomplished by the reference structure of each module's average current. Each converter has two stages and it is separated into PFC, which is responsible for harmonic regulation, and LLC resonant converter, which controls output voltage. To verified the performance of the proposed method, two 2KW prototypes has been implemented and experimented.