• 제목/요약/키워드: unaccounted-for water

검색결과 6건 처리시간 0.017초

가정용 13mm 수도계량기 미감지율 조사연구 (A Study on Under-registration of 13mm Water Meters)

  • 안재찬;하성호;정판식;최정섭;구자용
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.506-514
    • /
    • 2005
  • Unaccounted-for water subtracting water sold from produced water includes leakage, under-registration, unauthorized use, etc. To improve accounted-for water ratio, firstly, it should be attempted to accurately identify where unaccounted-for water is, and then it must to be reduced. Under-registration of meter is caused by allowable tolerance of meter, improper size of meter installed, gradient installation, etc. Under-registered water of meters has ever been the second large amount of unaccounted-for water next to leakage, but still is not estimated exactly. In this study, the estimated value as under-registered water was obtained by using the selected-area modeling program. As a result, the under-registered water ratio of 13mm meters was approximately 1.23%. Those of meters according to ages 1, 3, and, 5 years old were 1.46% 2.77% and, 2.26%, respectively but that of 7 years old meters showed over-registration of 1.59%.

누수탐사에 의한 유량분석 및 보수의 경제적 효과 (Analysis of Flow and Economic Benefit Through Water Leakage Detection and Repair)

  • 이승철;이상일
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.8-15
    • /
    • 2005
  • Field measurement data on water leakage are not readily available and it causes inaccurate assessment of water demand and poor supply planning. In this study, the procedure for leakage detection and unaccounted water calculation is proposed and applied to a city. The city has suffered from the significant amount of leak water and the financial loss as a result. Measurements were made for pressure and flow at 18 locations before and after the repair. Repair of the leakage increased pressure up to $2.0kgf/cm^2$ and saved 17.1% of water supply from distribution reservoirs. Monetary value of annual water savings for the entire city amounts to 1 billion won. It is believed that leakage detection and data analysis conducted in this study will contribute to the change of current practice and to the establishment of better water supply management system.

20~50mm 수도계량기 미감지율 조사분석 (Investigation on Under-registration of 20 mm to 50 mm Water Meters)

  • 안재찬;하성호;박태준;김석정;구자용
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.582-594
    • /
    • 2005
  • The under-registration of water meters of 20mm to 50mm in diameter, installed in Seoul city, was estimated by random sample method. The sample sites and sampled meters were selected for the measurements of flow rates and accuracy tests, respectively. The measurement of flow rates was conducted for 20mm to 50mm meters for about 20 days per site using flow meters and data loggers. The under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was observed as 3.96%, 1.10%, 2.47%, 4.04%, and 1.04%, respectively. The under-registration might be increased more or less as malfunction and failure of the sampled meters was not considered. In this study the under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was accurately estimated on the basis of the investigation data. The estimation of under-registration of water meters, one of the basic figures in water industry, contributed to accurate calculation of leakage, water supply and consumption, and strategic planning to reduce the unaccounted-for water.

Investigations on the Pu-to-244Cm ratio method for Pu accountancy in pyroprocessing

  • Sunil S. Chirayath;Heukjin Boo;Seung Min Woo
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3525-3534
    • /
    • 2023
  • Non-uniformity of Pu and Cm composition in used nuclear fuel was analyzed to determine its effect on Pu accountancy in pyroprocessing, while employing the Pu-to-244Cm ratio method. Burnup simulation of a typical pressurized water reactor fuel assembly, required for the analysis, was carried out using MCNP code. Used fuel nuclide composition, as a function of nine axial and two radial meshes, were evaluated. The axial variation of neutron flux and self-shielding effects were found to affect the uniformity of Pu and Cm compositions and in turn the Pu-to-244Cm ratio. However, the results of the study showed that these non-uniformities do not affect the use of Pu-to-244Cm ratio method for Pu accountancy, if the measurement samples are drawn from the voloxidized powder at the feed step of pyroprocessing. 'Material Unaccounted For' and its uncertainty estimates are also presented for a pyrprocessing facility to verify safeguards monitoring requirements of the IAEA.

산림에서의 젖은 군락 증발 관측: 고찰 (Measurements of Wet Canopy Evaporation in Forests: A Review)

  • 권효정
    • 한국농림기상학회지
    • /
    • 제13권2호
    • /
    • pp.56-68
    • /
    • 2011
  • 산림에서의 차단강수증발(EWC)은 증발산과 강수에 중요한 기여를 한다. 따라서, 산림에서의 수문순환을 이해하기 위해서는 정확한 $E_{WC}$를 산정하는 것이 중요하다. 본 고찰에서는 $E_{WC}$의 측정방법을 소개하고, 선행 연구에서 보고된 산림형태(예를 들면, 활엽수림, 침엽수림, 혼효림, 열대림)에 따른 $E_{WC}$ 값과 측정시 고려해야 할 사항에 대하여 논의하였다. 전형적인 $E_{WC}$ 측정에는 물 수지, 에너지 수지 및 Penman-Monteith 방법이 있다. 전반적으로, $E_{WC}$는 강수량의 5~54%를 차지하였으며, 같은 산림형태내에서도 $E_{WC}$의 강수량에 대한 기여도는 큰 변동을 보였다. 이러한 변동에는 강수강도, 기상조건, 군락 구조 특성이 영향을 미치는 것으로 나타났다. 따라서 특정 산림형태에서의 $E_{WC}$의 강수량에 대한 기여도를 정량화하는 것은 어려울 것으로 판단된다. 관측시 발생하는 오차는 $E_{WC}$ 정량화의 불확실성을 증대 시킨다. 물수지 방법의 경우, 풍속의 영향을 받는 강수 관측과 군락 구조의 공간적 비균질성의 영향을 받는 수관통과우 등의 관측 오차를 들 수 있다. 에너지 수지 방법의 경우에는 현열 플럭스와 열저류항의 관측이 주요 오차의 원인이 되며, Penman-Monteith 방법은 공기전도도와 현열의 이류 추정에서 발생하는 오차에 주의를 기울여야 한다. 각 측정방법의 오차를 최소화하고 신뢰할 수 있는 $E_{WC}$를 얻기위해서는 수문학적 방법과 미기상학적 방법, 즉 물 수지와 에너지 수지 방법을 함께 사용하는 것이 바람직하다.

중질소 추적자법을 이용한 Condensed Molasses Solubles(CMS) 함유 $NH_4{^+}$의 토양 중 행동 연구 (Evaluation of Fate of $NH_4{^+}$ of Condensed Molasses Solubles(CMS) in Soil Using by $^{15}N$-Tracer Method)

  • 이상모;최우정;윤석인;최영대;노희명;박지원
    • 한국토양비료학회지
    • /
    • 제35권2호
    • /
    • pp.69-76
    • /
    • 2002
  • 본 연구는 CMS에 함유된 $NH_4{^+}$의 토양 중 행동을 연구하기 위해 $NH_4{^+}$을 중질소 ($^{15}N$)로 표지한 후 수분 불포화 조건과 수분 포화 조건에서 0, 2, 4, 7, 14 및 21일 동안 항온배양 실험을 수행하였다. 불포화 조건의 토양 pH는 6.1에서 5.4로 지속적으로 감소하였고, 포화조건에서는 처리 2일 후 6.5로 증가한 후 일정하게 유지하였다. 암모늄태 질소의 농도는 불포화 조건에서 포화 조건보다 3배 빠르게 감소하였다. 질산태 질소의 농도는 불포화 조건에서는 21일까지 $17.4mg\;kg^{-1}$에서 $155.4mg\;kg^{-1}$으로 지속적으로 증가했지만 포화 조건에서는 낮은 수준(약 $8.0mg\;kg^{-1}$)으로 유지되었다. 항온배양 후 21일에는 불포화 조건에서 처리된 $^{15}NH_4{^+}$는 질산화과정을 거쳐 질산태 질소 형태로 52.4% 존재하였고 포화 조건에서는 1%이하로 존재하였다. 21 후 $NO_3{^-}$$^{15}N$ atom % excess는 불포화 조건에서 1.63%, 포화 조건에서는 0.32%였다. 처리된 $^{15}NH_4{^+}$중에서 항온배양 기간동안 부동화된 양은 불포화 조건에서 19.6%, 포화 조건에서는 17.0%였으며, 대부분 처리 후 4일 이내에 부동화되었다. 처리된 $^{15}NH_4{^+}-N$ 중 탈질 등으로 손실되어 최종적으로 회수되지 못한 비율은 불포화 조건에서는 28.4%, 포화 조건에서는 67.6%였다.