• Title/Summary/Keyword: ultrasound-guide

Search Result 30, Processing Time 0.031 seconds

Magnetic Resonance Imaging of Placenta Accreta Spectrum: A Step-by-Step Approach

  • Sitthipong Srisajjakul;Patcharin Prapaisilp;Sirikan Bangchokdee
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.198-212
    • /
    • 2021
  • Placenta accreta spectrum (PAS) is an abnormal placental adherence or invasion of the myometrium or extrauterine structures. As PAS is primarily staged and managed surgically, imaging can only guide and facilitate diagnosis. But, imaging can aid in preparations for surgical complexity in some cases of PAS. Ultrasound remains the imaging modality of choice; however, magnetic resonance imaging (MRI) is required for evaluation of areas difficult to visualize on ultrasound, and the assessment of the extent of placenta accreta. Numerous MRI features of PAS have been described, including dark intraplacental bands, placental bulge, and placental heterogeneity. Failure to diagnose PAS carries a risk of massive hemorrhage and surgical complications. This article describes a comprehensive, step-by-step approach to diagnostic imaging and its potential pitfalls.

The Effectiveness of Ultrasound-guide Steroid Injection According to Morton's Neuroma Size (모톤씨 신경종 크기에 따른 초음파 유도하 스테로이드 주사 효과의 비교분석)

  • Kim, Hak Jun;Hur, Chang Ryong;Kim, Jae Kyun;Jang, Kyu Seon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.61-65
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effectiveness of ultrasound-guide steroid injection according to Morton's neuroma size. Materials and Methods: From October 2008 to September 2011, 17 patients (23 cases) diagnosed with Morton's neuroma were investigated. All cases were female and mean age was 52.6 years old. Neuroma were measured by the horizontal and longitudinal length of the mass and underwent ultrasound-guided steroid (5 mg dexamethasone) injection. The efficacy of the injection was determined by Visual Analogue Scale pain score and patient satisfaction(subdivided 4 group-much improved, improved, not improved, aggrevation) Results: 7 of 23(30.4%) cases showed much improved and improved satisfaction and mean longitudinal and horizontal length were $0.71{\pm}0.39cm$ and $0.47{\pm}0.24cm$, respectively. 16 of 23(69.6%) cases showed not improved and aggrevation satisfaction and mean longitudinal and horizontal length were $0.83{\pm}0.42cm$ and $0.54{\pm}0.14cm$, repectively. There was a significant difference in VAS and patient satisfaction in case longitudinal and horizontal length were smaller than 0.5 cm and 0.4 cm. (p<0.05) Conclusion: The ultrasonography is a important modality in diagnosis and treatment of morton's neuroma. Ultrasound-guide steroid injection is effective in case longitudinal and horizontal length were smaller than 0.5 cm and 0.4 cm, respectively.

  • PDF

Sonoanatomic Variation of Pes Anserine Bursa

  • Imani, Farnad;Rahimzadeh, Poupak;Gharehdag, Farid Abolhasan;Faiz, Seyed Hamid Reza
    • The Korean Journal of Pain
    • /
    • v.26 no.3
    • /
    • pp.249-254
    • /
    • 2013
  • Background: The pes anserine bursa lies beneath the pes anserine tendon, which is the insertional tendon of the sartorius, gracilis, and semitendinosus muscles on the medial side of the tibia, but it can lie in different sites in the medial knee. Accurate diagnosis of the position of the bursa is critical for diagnostic and therapeutic goals. The aim of this study was to evaluate sonoanatomic variations of the pes anserine bursa in the medial knee. Methods: One hundred seventy asymptomatic volunteers were enrolled in this study. Using ultrasound imaging (transverse approach, 7-13 MHz linear array probe) the sonoanatomic position of the pes anserine bursa and its relation to the pes anserine tendon were evaluated. Additionally, we evaluated the sonoanatomic variation of the saphenous nerve. Results: The position of the pes anserine bursa was between the medial collateral ligament and the pes anserine tendons in 21.2%/18.8% (males/females) of subjects; between the pes anserine tendons and the tibia in 67.1%/64.7% (m/f); and among the pes anserine tendons in 8.2%/12.9% (m/f). No significant differences in the position of the bursa existed between males and females. The saphenous nerve was found within the pes anserine tendons in 77.6%/74.1% (m/f) of subjects, but outside the pes anserine tendons in 18.8%/15.3% (m/f). Visibility of sonoanatomic structures was not related to either gender or BMI. Conclusions: Ultrasound provides very accurate information about variations in the pes anserine bursa and the saphenous nerve. This suggests that our proposed ultrasound method can be a reliable guide to facilitate approaches to the medial knee for diagnostic and therapeutic objectives.

Effect of bST Co-Treatment with FSH on Transvaginal Ultrasound-Guided Oocyte Retrieval(TVR) in Calves (송아지 난소에서 초음파 유도에 의한 한우의 미성숙난자 채취시에 bST-FSH 처리효과에 관한 연구)

  • 이병천;이강남;김남렬;황우석
    • Journal of Embryo Transfer
    • /
    • v.11 no.2
    • /
    • pp.103-109
    • /
    • 1996
  • The aim of this study was to evaluate the effect of recombinant bovine somatotropin (bST; Boostin-S, LG Chem) treatment with FSH (Super OV) or PMSG on superovulatory response for transvaginal ultrasound-guided oocyte retrieval (TVR) in calves. Eight Korean Native Cattle(KNC) heifer calves; 150 to 240 days old; were randomly assigned to four treatment groups: 1) FSH(75 mg); 2) FSH (75 mg) + bST(500mg) 3) PMSG(1;000 IU); 4) PMSG(1, 000 IU) + bST(500 mg). Experimental calves in group 1 (n=2) and 2(n=2) were weekly superovulated for 4 consecutive weeks with daily injection of FSH for 3days and the next day subjected to TVR session. Animals in group 3 (n=2) and 4(n=2) were weekly stimulated for 4 consecutive weeks with a single dose of 1, 000 IU PMSG. TVR was performed on 72 hours after PMSG injection. Calves in group 2 and 4 was received injection of 500 mg of bST every 10 days. At each TVR session, follicle number and size were recorded; the oocytes collected and graded according to cumulus and cytoplasm investment. Collected oocyte were determined viable oocyte according to morphological quality with granulation of oocyte and number and status of cumlulus cells. IVM and IVF were performed and assessed cleavage rate on day 3 after fertilization. A Sonovet 600(Medison, Co., Ltd) realtime ultrasound scanner with a 6.5 MHz convex transducer, fixed at the tip of 500 mm estended handle equipped with a needle guide was used in collecting oocyte. Differences between groups were analysed by chi-square test. The population of large follicle ($\geq$5 nun) and aspiration rate were not significant different among the 4 groups. But, the number of small follicles (<5 mm) and aspirated oocyte in the KNC calves treated with bST were 1.3~1.6 times higher than in KNC calves treat with FSH or PMSG alone. In conclusion, the administration of bST with FSH or PMSG at superovulation for TVR in calves was increase the nurnber of small follicle which was influenced the number of aspiratable follicle.

  • PDF

Diagnostic Performance of Radial Probe Endobronchial Ultrasound without a Guide-Sheath and the Feasibility of Molecular Analysis

  • Moon, Seong Mi;Choe, Junsu;Jeong, Byeong-Ho;Um, Sang-Won;Kim, Hojoong;Kwon, O Jung;Lee, Kyungjong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.4
    • /
    • pp.319-327
    • /
    • 2019
  • Background: Radial probe endobronchial ultrasound (R-EBUS), is effective for tissue diagnosis of lung lesions. We evaluated the diagnostic performance of R-EBUS both a guide-sheath and fluoroscopy and identified factors associated with accurate diagnosis. The feasibility of molecular and genetic testing, using specimens obtained by R-EBUS, was also investigated. Methods: The study retrospectively reviewed 211 patients undergoing R-EBUS without a guide-sheath and fluoroscopy, June 2016-May 2017. After excluding 27 patients of which the target lesion was not reached, 184 were finally included. Multivariate logistic regression was used, to identify factors associated with accurate diagnosis. Results: Among 184 patients, R-EBUS-guided biopsy diagnosed malignancy in 109 patients (59%). The remaining 75 patients (41%) with non-malignant results underwent additional work-ups, and 34 were diagnosed with malignancy. Based on final diagnosis, diagnostic accuracy was 80% (136/170), and sensitivity and specificity for malignancy were 76% (109/143) and 100% (27/27), respectively. In multivariate analysis, peripheral location (adjusted odds ratio [aOR], 3.925; 95% confidence interval [CI], 1.203-12.811; p=0.023), and central position of the probe (aOR, 2.435; 95% CI, 1.424-7.013; p=0.035), were associated with accurate diagnosis of malignancy. Molecular and genetic analyses were successful, in all but one case, with inadequate specimens. Conclusion: R-EBUS-guided biopsy without equipment, is effective for tissue diagnosis. Peripheral location and central position of the radial probe, were crucial for accurate diagnosis. Performance of molecular and genetic testing, using samples obtained by R-EBUS, was satisfactory.

Benefit of Ultrasound-guided Therapeutic Medial Branch Blocks after Percutaneous Epidural Neuroplasty (신경 성형술 후 초음파 유도하 내측 분지 차단술의 유용성)

  • Moon, Sang Ho;Lee, Song;Jung, Jae-Hyun;Shin, Won Shik
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose: To determine the therapeutic effectiveness of ultrasound-guided medial branch block (MBB) for the herniated lumbar disc patients who did not relieve their symptoms after percutaneous epidural neuroplasty (PEN). Materials and Methods: From August 2011 to February 2013, 559 patients with herniated lumbar disc have undergone PEN. Among them, ultrasound-guided MBBs were performed for the patients who had sustained low back pain and refered pain to lower extremities. Eighty eight patients were followed at 1 month and 39 patients could be followed at 6 month. All procedures have been performed by the one operator, and 23 G, 10 cm needle was placed and 0.5% lidocaine was injected under ultrasound guide. To target medial branches from L1 to L5, the groove at the root of transverse process and the base of superior articular process has been identified on transverse scan. Patients were evaluated by Visual Analog Scale (VAS) and Oswestry Disability Index (ODI) at each follow-up. Significant pain relief was described as a 50% or more reduction in VAS and significant improvement in function was described as at least a 40% reduction in ODI. Results: VAS showed that preprocedure pain ($7.35{\pm}1.68$; $mean{\pm}SD$) significantly decreased 1 month after block ($3.36{\pm}2.98$) and 6 month ($3.05{\pm}2.27$) (p<0.05). ODI also showed that preprocedure score ($32.82{\pm}8.77$) significantly decreased at 1 month ($15.14{\pm}14.01$) and 6 month ($12.97{\pm}8.82$) (p<0.05). Significant pain relief was observed in 64.49% at 1 month and 64.10% at 6 month. Significant functional improvement in 59.81% at 1 month and 61.54% at 6 month. Conclusion: Ultrasound-guided medial branch block may sufficiently treat the facet problems secondary from disc disease.

  • PDF

Fine Needle Aspiration Cytology of Ovarian Cysts (난소 낭성 병변의 세침흡인 세포검사)

  • Park, In-Ae;Ham, Eui-Keun
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.1
    • /
    • pp.51-58
    • /
    • 1996
  • The cytologic samples of 26 ovarian cystic lesions from 25 women, aspirated under guide by trans-vaginal ultrasound, were evaluated for clinicopathologic correlation. Clinically 20 women were seeking medical assistance for infertility problems, and trans-vaginal cyst aspiration was done during follow-up of ovulation induction. Among them seven cases were histologically confirmed. Twenty cases of "benign cyst" in cytologic diagnosis were follicullar cyst and two cases of "endometriotic cyst" in cytology were histologically also proven in one case. One false positive diagnosis was given to corpus luteum cyst. It is emphasized that because the cysts are aspirated transvaginally and mature squamous epithelial cells occasionally could be mixed in the sample, attention should be given not to diagnose such cases as mature cystic teratoma. According to this study. ovarian aspiration cytology is useful in the management of cystic ovarian lesions, particularly in young women.

  • PDF

Radial Probe Endobronchial Ultrasound Using Guide Sheath-Guided Transbronchial Lung Biopsy in Peripheral Pulmonary Lesions without Fluoroscopy

  • Hong, Kyung Soo;Ahn, Heeyun;Lee, Kwan Ho;Chung, Jin Hong;Shin, Kyeong-Cheol;Jin, Hyun Jung;Jang, Jong Geol;Lee, Seok Soo;Jang, Min Hye;Ahn, June Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.282-290
    • /
    • 2021
  • Background: Radial probe endobronchial ultrasound-guided transbronchial lung biopsy (RP-EBUS-TBLB) has improved the diagnostic yield of bronchoscopic biopsy of peripheral pulmonary lesions (PPLs). The diagnostic yield and complications of RP-EBUS-TBLB for PPLs vary depending on the technique, such as using a guide sheath (GS) or fluoroscopy. In this study, we investigated the utility of RP-EBUS-TBLB using a GS without fluoroscopy for diagnosing PPLs. Methods: We retrospectively reviewed data from 607 patients who underwent RP-EBUS of PPLs from January 2019 to July 2020. TBLB was performed using RP-EBUS with a GS without fluoroscopy. The diagnostic yield and complications were assessed. Multivariable logistic regression analyses were used to identify factors affecting the diagnostic yields. Results: The overall diagnostic accuracy was 76.1% (462/607). In multivariable analyses, the size of the lesion (≥20 mm; odds ratio [OR], 2.06; 95% confidence interval [CI], 1.27-3.33; p=0.003), positive bronchus sign in chest computed tomography (OR, 2.30; 95% CI, 1.40-3.78; p=0.001), a solid lesion (OR, 2.40; 95% CI, 1.31-4.41; p=0.005), and an EBUS image with the probe within the lesion (OR, 6.98; 95% CI, 4.38-11.12; p<0.001) were associated with diagnostic success. Pneumothorax occurred in 2.0% (12/607) of cases and chest tube insertion was required in 0.5% (3/607) of patients. Conclusion: RP-EBUS-TBLB using a GS without fluoroscopy is a highly accurate diagnostic method in diagnosing PPLs that does not involve radiation exposure and has acceptable complication rates.

The new classification for fatty-type gynecomastia (lipomastia) and 1000 cases review (지방형 여성형유방증에 대한 새로운 분류와 1000증례)

  • Yoon, Sang Yub;Kang, Min Gu
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.773-778
    • /
    • 2009
  • Purpose: The authors propose the new classification of fatty - type gynecomastia(lipomastia) which can serve as a guide for modifying the periareolar technique. Methods: A retrospective analysis was made of 1000 cases of lipomastia operated on in the last 17 months. The extent of the clinical result, the technique employed, and the complications were observed. On the basis of this review the authors observed that at grade I(fat component < 50 ml, fibroglandular component < 3 g each breast), flattening of the thorax can be achieved by means of stab incision, ultrasound - assisted lipectomy(UAL), scavenging suction - assisted lipectomy(SAL) and tissue shaving. At grade II(50 < < 150 ml, 3 < < 5 g), stab incision, UAL, SAL and pull - out method(POM) using small curved scissors. At grade III(150 < < 300 ml, 5 < < 15 g and prominent inframammary fold(IMF)), minimal incision (5 - 6 mm), UAL, SAL and POM using small angulated scissors, and blunting IMF. At grade IV (300 < < 500 ml, 15 < < 30 g, and glandular ptosis), minimal incision (5 - 6 mm), UAL, SAL, fibroglandular excision using small angulated scissors, cutting IMF and fixation of nipple - areola complex(NAC) becomes necessary. At grade V (> 500 ml, > 30 g and ptosis), small incision (7 - 8 mm), UAL, SAL, fibroglandular excision using large angulated scissors, cutting IMF, upper repositioning of NAC and delayed circumareolar skin reduction or chest lifting becomes necessary. Results: The complications were minimal but there were hematoma (n = 7), infection (n = 3) and hypertrophic scar (n =13). Almost patients were satisfied with the outcome. Conclusion: This simple classification may help in choosing the most suitable treatment, thus avoiding insufficient or invasive treatments and undesirable scars.

Breast Imaging Reporting and Data System (BI-RADS): Advantages and Limitations (유방영상 판독과 자료체계: 장점과 한계)

  • Ji Soo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.3-14
    • /
    • 2023
  • Breast Imaging Reporting and Data System (BI-RADS) is a communication and data tracking system that standardizes and controls the quality of reporting by presenting lexicon descriptors, assessment categories, and recommendations for managing breast lesions. Using standardized terminology recommended by BI-RADS, radiologists can concisely and reproducibly communicate breast imaging results to clinicians. They can also provide the estimated malignant probability of the lesions found and guide management for them by determining the final assessment category. The limitations of BI-RADS 5th edition currently in use are that there are some areas for which standardized terminologies still need to be established, and that the diagnostic criteria of MRI assessment categories 3 and 4 are ambiguous compared to those for mammography or ultrasound. The next revision of BI-RADS is expected to include solutions for overcoming current limitations.