• Title/Summary/Keyword: ultrasound velocity

Search Result 152, Processing Time 0.024 seconds

Noninvasive Estimation of Moxibustion Effect on Peripheral Blood Flow by Doppler Ultrasound in Stroke Patients with Hemiplegia: Case Series (뜸치료가 뇌졸중 편마비의 요골동맥 혈류변화에 대해 미치는 영향)

  • Yoon, Seung-Kyou;Lee, Sang-Hoon;Jung, Woo-Sang;Bae, Young-Min
    • The Journal of Korean Medicine
    • /
    • v.31 no.4
    • /
    • pp.178-186
    • /
    • 2010
  • Objectives: This study was to investigate the effect of moxibustion on peripheral blood flow by Doppler ultrasound in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Results: The mean value of blood flow velocity in 13 patients showed a tendency of increase during moxibustion, but there was no significant difference in blood flow velocity before and after moxibustion, or pulsation index during and after moxibustion. In addition, among the five patients who showed marked increase tendency on the blood velocity graph, there was significant increase in blood velocity during, and after moxibustion compared with before moxibustion. Conclusions: This study suggests that moxibustion has an effect on peripheral blood flow in stroke patients with hemiplegia. Further validity tests with a larger scale sample are needed for the evidence of its practical use.

A Study on the Estimation of Temperature in tissue by Ultrasound (초음파에 의한 조직내 온도추정에 관한 연구)

  • Choi, H.H.;Lee, S.M.;Park, S.W.;Hong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.717-719
    • /
    • 1988
  • The continued interest in diagnostic applications of ultrasound has led to a need for more detailed knowledge of the ultrasonic properties of biological tissues. In this paper, temperature dependence of ultrasound velocity and attenuation is considered through a fundamental experiment. Acryl and Pig Liver are used as specimen. Data is collected over the temperature range of 20-50 C. As a result, we know that ultrasound velocity and attenuation coefficient are uniformly changed in proportion as specimen's temperature.

  • PDF

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

Accuracy of Pulsed Doppler Ultrasound Velocity Measurements : In Vitro Flow Phantom Study (Pulsed Doppler 초음파속도측정의 정확도 판정 : 유동 phantom 연구)

  • Kim, Young-Ho;Min, Byung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.153-156
    • /
    • 1994
  • An in vitro steady flow experiment was performed in order to test the accuracy of velocity measurement obtained through a pulsed Doppler echocardiography. A flow phantom was designed for the use in a wide velocity range at a given flow rate. The results showed that the pulsed Doppler velocity measurement obtained in this flow phantom is accurate at low flow rates. However, ultrasound velocity measurement should be performed under a careful considerations of PRF and Doppler gain settings, especially at higher flow rates.

  • PDF

Estimation of portal blood flow using pulsed doppler ultrasound in the anesthetized dog (도플러 초음파를 이용한 개에서 마취에 따른 간문맥 혈류량 변화의 측정)

  • Lee, Young-won
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.659-663
    • /
    • 1998
  • Portal bood flow was measured with pulsed Doppler ultrasound in twenty anesthetized dogs. In anesthetized dogs with xylazine HCl, the average of portal blood flow velocity was reduced($11.68{\pm}1.55cm/sec$ vs. normal $16.67{\pm}1.77cm/sec$). Average portal blood flow was also decreased compared to normal($28.36{\pm}11.61ml/min/kg$ vs. normal $43.12{\pm}14.46 ml/min/kg$). And congestion index was increased($0.0368{\pm}0.0117cm{\cdot}sec$) vs. normal $0.0297{\pm}0.0062cm{\cdot}sec$). In anesthetized dogs with ketamine HCl, portal blood flow velocity was slightly increased ($22.62{\pm}2.53cm/sec$ vs. normal $16.67{\pm}1.77cm/sec$. Also mean portal blood flow was slightly increased($43.12{\pm}14.46ml/min/kg$ vs. normal $55.32{\pm}19.99ml/min/kg$). In anesthetized dogs with tiletamine and zolazepam, portal blood flow velocity and portal blood flow were unchanged.

  • PDF

Ultrasound Attenuation in the Assessment of Bone Mineral Density and Elastic Modulus of Human Trabecular Bone

  • Han, S.M.;Kim, M.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 1998
  • The objective of this study was to re-evaluate ultrasound attenuation as an indicator of bone properties. Ultrasound attenuation(BUA), were measured in the three orthogonal directions of trabecular bone cubes, Measurements of bone mineral density(BMD) were made using quantitative computed tomography and apparent density by weighing bone specimens and measuring their volume. Ultrasonic modulus was calculated from the standard equation with apparent density and ultrasound velocity. Ultrasound attenuation at a frequency of 0.5 MHz and BUA were correlated with BMD and ultrasonic modulus in the anterior/posterior, medial/lateral, and superior/inferior directions. Analysis of correlations demonstrated that attenuation at 0.5 MHz was superior to BUA in describing both BMD and elastic modulus of trabecular bone. This result may be used to improve current ultrasound diagnostic techniques for assessing bone status.

  • PDF

Analysis of Relations Between Transmission Time of Therapeutic Ultrasound and Pulse Transit Time (치료용 초음파의 투과시간과 PTT의 상관관계 분석)

  • Kim, Sung-Min;Lee, Joo-Hwan;Choi, Byeong-Cheol;Jung, Whoi-Seong;Bae, Ha-Suk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2345-2350
    • /
    • 2008
  • Recently, ultrasound is becoming a universal way of treatment when it comes to clinic. The thermal effect of therapeutic ultrasound can raise the temperature of tissue without damage and thus increases the flow rate, and this leads to the oxygen transportation velocity of peripheral tissue and ultimately facilitates the metabolism. The purpose of this research is analyzing relations between PTT and transmission time of therapeutic ultrasound, and in this study the PTT variation due to respective transmission time of ultrasound upon 17 normal persons was measured and as a result, it was observed that PTT increases as transmission time of therapeutic ultrasound

Clinical study on the estimation of blood flow velocity using doppler ultrasound of the cerebral artery in stroke patients (도플러 초음파를 이용한 중풍환자(中風患者)의 뇌혈관(腦血管) 혈류측정(血流測定)에 관한 임상적(臨床的) 연구(硏究) (경동맥(頸動脈), 추골동맥(椎骨動脈) 및 기저동맥(基底動脈)을 중심으로))

  • Chang, In-Su;Sun, Jungn-Ki
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.345-360
    • /
    • 1996
  • Background and Purpose: To evaluate the blood flow velocity using doppler ultrasound of the carotid artery, vertebral artery, and basilar artery in stroke patients Material and Methods: To evaluate the blood flow, I measured the peak systolic velocity and mean velocity of the common carotid artery(CCA), internal carotid artery(ICA), external carotid artery (ECA). vertebral artery(VA), and basilar artery(BA) in 44 stroke patients and 15 healthy adults. To investigate the difference between ischemic stroke patients and normal healthy adults, I selected 44 ischemic stroke patients diagnosed by brain CT and brain MRI, and 15 healthy adults who did not have any symptoms of stroke, hypertension, heart disease, and diabetes melitus. Results: Peak velocity in normal adults was 50.6${\pm}$1.6cm/sec in the CCA, 67.2${\pm}$1.7cm/sec in the ICA, 62.5${\pm}$2.4cm/see in the ECA, 45.5${\pm}$1.9cm/sec VA. and 50.5${\pm}$3.5cm/sec in the BA. Mean velocity in normal adults was 26.9${\pm}$1.1cm/sec in the CCA, 43.7${\pm}$1.4cm/sec in the ICA, 26.7${\pm}$1.3cm/sec in the ECA. 31.6${\pm}$1.9cm/sec in the VA and 33.0${\pm}$2.6cm/sec in the BA. In this study, there was a significant increase in the velocity of ICA, ECA, and VA of ischemic stroke patients in comparison with normal healthy adults. And the blood flow velocity of this study in the CCA and ECA was different from other reported foreign values and the other known values in my country. Conclusion: There was a significant difference in the blood flow velocity between ischemic stroke patients and normal healthy adults. And the blood flow velocity of this study was different from other reported foreign values and the other known values in my country. Therefore, it needs more detailed studies about old aged Korean and ischemic stroke patients than previous studies.

  • PDF

Ultrasonic Measurement of Tissue Motion for the Diagnosis of Disease

  • Beach Kirk W.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.3-12
    • /
    • 2003
  • Ultrasonic pulsed Doppler velocimetry has become a standard international method of classifying carotid disease. Because the measured angle adjusted velocity increases as the Doppler angle increases, examinations should be performed at a convenient standard Doppler examination angle. An angle of 60 degrees is achievable throughout most examinations. Multiple Doppler viewing angles allow the acquisition of velocity vectors during the cardiac cycle, revealing the complex velocity patterns. Ultrasonic velocimetry (whether Doppler or time domain) is based on changes in the phase of the ultrasound echo. Other examinations can be done based on the echo phase. Slow motions of organs such as the brain can be used to monitor changes in edema. Measurements of tissue strain due to the pulsatile filling of the arterioles. This plethysmographic imaging method can display differences in tissue perfusion because of different tissue types and changes in autonomic activity.

  • PDF

Study on Velocity In-homogeneous Effect in fat and its Correction in Ultrasound Imaging System (초음파 의료영상에서 지방조직의 음속도 불균일 효과의 영향과 그 보상에 관한 연구)

  • Kim, Jae-Hyeon;Bae, Mu-Ho;Jeong, Mok-Geun
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.9-18
    • /
    • 1998
  • In this paper, we present the degradation of focusing induced by velocity inhomogeneity in human tissue. For simulation, the fatty layer which is the major factor of degradation for its lower velocity, is modeled as a uniform velocity perturbation layer. And we simulate the degradation of resolution resulting from change of beam path due to refraction and the time delay due to velocity difference. We show that focusing error can be compensated for considering the velocity inhomogeneity only. The proposed compensation method can be operated in real time in the presently used digital focusing systems.

  • PDF