• 제목/요약/키워드: ultrasound velocity

검색결과 150건 처리시간 0.025초

TCD를 이용한 정상군과 중풍원인질환군의 혈류측정에 관한 비교연구 (Case-control Study : Cerebral Blood Flow as Measured by TCD in Patients with Risk Factors for Stroke)

  • 허정은;권정남;신원탁;김종득;이상희;손연희;김영균
    • 대한한방내과학회지
    • /
    • 제28권2호
    • /
    • pp.250-261
    • /
    • 2007
  • Objectives : The purpose of this study was to evaluate the blood flow using doppler ultrasound of the MCA, ACA, PCA, BA, ICA in the patients with risk factor for stroke. Methods : 110 patients with risk factor for stroke were selected who had hypertension, diabetes mellitus, hyperlipidemia, or heart disease, as well as 89 healthy adults who did not have any symptoms of those diseases. To evaluate the blood flow, the Vs and Vm of the MCA, ACA, PCA, BA, and ICA in the two groups were measured. Result : In normal healthy adults, subjects showed a decrease in the Vs and Vm: with advancing in age, there was a significant difference in the Vs of MCA, PCA, BA, and ICA. There was a significant difference in the Vm of MCA, PCA, BA, and ICA. In normal healthy adults, females showed high velocities in all examined vessels. There was a significant difference in the Vs of BA. There was a significant difference in the Vm of BA, and ICA. There was a decrease in the Vs, and Vm of all examined vessels of patients with risk factors for stroke in comparison with normal healthy adults. There was no significant difference in the Vs. There was a significant difference in the Vm of MCA, ACA, and PCA. Results were the same between patients aged under 50 and total patients in the Vs and Vm of examined vessels. There were differences between patients aged over 50 and total patients in the Vs of MCA, PCA, BA and for patients aged over 50; patients with risk factor for stroke who had hypertension, diabetes mellitus, hyperlipidemia, or heat disease has higher Vs than healthy adults. Conclusions : There was a significant difference in the blood flow velocity between patients with risk factors for stroke and healthy adults. However, this result was different from results of comparison of TCD findings between patients and healthy individuals by age. Therefore, more detailed studies about aged patients are needed.

  • PDF

천마추출물이 정상인의 뇌혈류에 미치는 영향 (Effect of Gastrodia Elata BL Water Extract on Human Cerebral Blood Flow using Transcranial Doppler)

  • 문상관;김영석;박성욱;정우상;고창남;조기호;배형섭
    • 대한한의학회지
    • /
    • 제26권1호
    • /
    • pp.115-122
    • /
    • 2005
  • Background and objective: Gastrodiae Rhizoma (GR), the rhizoma of Gastrodia elata BL., is one of the popular drugs to treat headache, dizziness, blackout, numbness of limbs, hemiplegia, facial paralysis, dysphrasia, and infantile convulsions. It has been reported that it provides an antihypertensive effect and lowers cerebrovascular resistance in animal experiments. However, there has been no data about these effects with human subjects. In this study, the author examined the effect of Gastrodiae water extracts on blood pressure and cerebrovascular reactivity in human subjects. Methods: We selected 16 normal volunteers, who were divided into 2 groups: Gastrodiae extract administration group and placebo (creamy powder) group. Using transcranial Doppler ultrasound, we monitored changes of mean flow velocity and breath-holding induced CO2 reactivity of middle cerebral artery in both groups. Mean blood pressure, heart rate and PETCO2 were measured using Compact Anesthesia Monitor. In both groups, all evaluation was performed during basal condition, and repeated at 30, 60, and 90 min after administration. Results: Gastrodiae extract decreased CO2 reactivity after administration, reaching the lowest level at 90 minutes $(-29.1\%\;vs.\;basal\;level)$, which showed significant difference compared with the placebo group (p = 0.004). In the placebo group, the pulse rates tended to decrease over time (at 90 minute, $-5.2\%$ vs. basal level) while in the Gastrodiae group the values showed nearly no change, which showed significant difference between both groups (p = 0.036). However, the changes of mean blood pressure and mean flow velocity did not show significant difference between both groups. Conclusion : This study demonstrated that Gastrodiae extract significantly decreased breath-holding induced CO2 reactivity. This result suggests that the clinical effect of Gastrodiae extract might be caused by increasing cerebral blood flow via dilation of cerebral resistant vessels instead of antihypertensive effect.

  • PDF

인삼, 홍삼 및 발효 홍삼이 정상인의 뇌혈류, 평균혈압, 맥박수에 미치는 영향 (Effects of Korean Ginseng, Korean Red Ginseng and Fermented Korean Red Ginseng on Cerebral Blood Flow, Cerebrovascular Reactivity, Systemic Blood Pressure and Pulse Rate in Humans)

  • 정동원;홍진우;신원준;박영민;정재한;김창현;민인규;박성욱;정우상;박정미;고창남;조기호;문상관
    • 대한한의학회지
    • /
    • 제27권3호
    • /
    • pp.38-50
    • /
    • 2006
  • Objectives: The aim of this study was to evaluate the effects of Korean ginseng (KG), Korean red ginseng (KRG) and fermented Korean red ginseng (FKRG) extracts on cerebral hemodynamics and to compare distinction of each extract. Methods: Ten healthy male volunteers $(26.0{\pm}1.8yrs)$ participated in the study according to double-blind and cross-over protocols. Each volunteer was blindly administered 500mg of KG, KRG, FKRG extract or placebo (Dextrin). Blinded researchers measured changes of hyperventilation-induced cerebrovascular reactivity (CVR), mean blood flow velocity (MBFV) of middle cerebral arteries (MCAs) and corrected blood flow velocity at $P_{ETCO2}=40mmHg$ (CV40) using transcranial Doppler ultrasound (DWL Co., Germany). Researchers also observed changes of mean blood pressure (MBP), pulse rate (PR) and expiratory $CO_2$ using S/5 Collector (Datex-Ohmeda Co., Finland). The evaluation was performed at basal condition, and repeated at 1, 2, 3, 4 and 5 hours after administration. Results: MBFV and CV40 in the KRG group tended to rise at I hour after administration, while those of the FKRG group tended to rise at 2 hours after administration. CVR increased significantly after 1 hour in the KRG group (p=0.009) and after 2 hours in the FKRG group (p=0.035), respectively. The KG group showed increasing tendency at 4 hours after administration. No group showed significant difference from the placebo in changes of MBP and PR. Conclusions: It is suggested that KG, KRG and FKRG extracts have effects of enhancing CVR and thus of increasing cerebral blood flow in human subjects.

  • PDF

초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법 (Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System)

  • 정영관;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권1호
    • /
    • pp.49-60
    • /
    • 2002
  • 본 논문에서는 프레임율의 저하없이 개선된 해상도를 얻을 수 있는 동시 다중 송신집속 기법을 제안한다. 제안한 기법은 짧은 펄스를 사용하여 한 영역에 고정 송신 집속하는 기존의 방법과는 달리 여러 송신 집속점에 서로 독립적으로 집속된 쳐프 신호들을 동시에 송신한다. 수신된 신호는 정합 과정을 통하여 송신 집속 위치에 따라 각 쳐프 신호로 분리되고 짧은 펄스로 압축된다. 이렇게 압축되고 분리된 신호들은 각각 수신 동적 집속된 후 거리에 따라 집속 위치별로 선택되고 하나의 신호로 결합되어 개선된 측방향 해상도의 영상을 구성한다. 송신시 동시에 여러 위치에 초음파를 집속하고 수신시 이를 분리하기 위해서 사용된 터프 신호들은 주파수 대역에서 분할되어 서로 직교 특성을 갖도록 설계되었는데 변환자의 제한된 대역폭내에 많은 수의 의미있는 쳐프 신호를 설계하기 위해서 인접한 두 쳐프 신호의 주파수 대역 겹침을 허용하였다. 이때 대역 겹침으로 발생한 상호상관값의 상승을 억제하기 위해 인접한 두 쳐프 신호의 주파수 변화 방향을 엇갈리게 하는 밥법을 제안하였다. 특히 대역분할로 설계된 쳐프 신호중 낮은 주파수 성분의 신호를 변환자로부터 가까운 지역에 집속하고 높은 주파수 성분의 쳐프 신호를 먼 지역에 집속함으로써 깊이에 따라 영상의 해상도의 질을 일정하게 유지시켰다 더욱이 상관기를 이용한 정합 과정에서 신호가 압축되기 때문에 펄스 압축 기법에서 얻는 SNR를 증가시키는 이점이 있다 이때 상관기를 통한 압축 과정에서 쳐프 신호의 첨두값이 쳐프 신호의 길이에 따라 증가하기 때문에 깊이에 따를 높은 주파수 성분의 감쇄에도 불구하고 이렇게 높은 주파수 성분의 터프 신호를 깊은 지역에 사용할 수 있었다. 제안한 동시 다중 송신집속 기반의 시스템을 상관기의 위치에 따라 이상적인 구조와 현실적인 구조로 나타냈으며, 모사 실험을 통하여 기존의 펄스 집속 기법과 비교하여 그 성능을 검증하였다.hrough the medium. By digitizing the analog receiver outputs, and recording the signals for spectral analysis, surface wave velocities can be identified. Modifications to the SASW method includes the reduction of boundary reflections as adopted on the surface waves before the point where the reflected compression waves reach the receivers. In this study, the correlation between the surface wave velocity and the compressive strength of cement mortar is developed using one 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slab of 2,000 psi (140 kgf/$\textrm{cm}^2$) and two 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slabs of 3,000 psi (210 kgf/$\textrm{cm}^2$). public transportation, and availability of locally grown food were the important factors for deciding the place compared to those who had higher education. The price was the factor which

Gender Differences in Physiological Effects of a Transient Exposure to Experimental Noise

  • ;;;;최석철
    • 대한의생명과학회지
    • /
    • 제12권4호
    • /
    • pp.375-383
    • /
    • 2006
  • The physiological responses following stress are different in individual or personality. We performed this study to clarify gender differences in influences of noise stress on physiological factors. 70 healthy subjects, which was divided man (n=30) and woman (n=40) groups, were exposed to 85 decibels of excavator noise for 15 minutes. Cardiac factors such as heart rate (HR), systolic and diastolic blood pressures (SBP and DBP, respectively), and heart rate-systolic pressure product (RPP) were determined. Transcranial Doppler ultrasound (TCD) was used to measure mean blood flow velocity (Vm), pulsatility index (PI), and resistance index (RI) in the middle, anterior and posterior cerebral arteries (MCA, ACA and PCA, respectively) before and during noise exposure. Cortisol level and hematological variables were also measured before (baseline) and immediately after the end of noise exposure. In the both groups HR, SBP, and RPP significantly decreased during noise exposure (P<0.05) but not significantly different between two groups (P>0.05). Vms of three cerebral arteries in man group decreased, whereas Vm of PCA in woman group fell during noise exposure (P<0.05). Vm, PI and RI in MCA and ACA during noise exposure were low in man group compared with woman group (P<0.05). Vm of PCA was low, whereas PI and RI of PCA were high in man group compared with woman group during noise exposure (P<0.05). Total leukocyte and red blood cell (RBC) counts slightly decreased during noise exposure but not significant (P>0.05). Levels in hematological variables decreased but not significant changed following noise exposure. Decreased rate of total leukocyte in man group was higher (P<0.05). Cortisol levels in the both groups decreased immediately after the end of noise exposure, while the decreased rate in man group was greater than that in woman group (p<0.05). These findings indicate that a transient exposure to experimental excavator noise may cause decreased changes in cardiac factors, cerebral hemodynamics and cortisol levels and the changes may be greater in men than in women.

  • PDF

단열된 배관의 유도초음파 최적 발생조건 선정에 관한 연구 (A Study on the Optimum Generation Condition of Ultrasonic Guided Waves for Insulation Pipelines)

  • 이동훈;조현준;강토;박동준;김병덕;허윤실;이연재
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.50-57
    • /
    • 2016
  • 배관은 석유화학플랜트에서 가장 많은 구성요소이며, 주요설비들에서 생산된 물질을 수송하는 매우 중요한 역할을 수행한다. 특히, 저온 또는 고온의 물질을 수송하는 배관들의 경우 물질의 온도변화를 최소화하기 위해 보온재를 배관의 외면에 덮어 사용하는 경우가 다수이다. 그러나 이러한 보온재에 덮인 배관들에서 부식이 발생할 경우 보온재를 제거하지 않고서는 확인하기 어렵기 때문에 현장검사시 유도초음파를 이용한 비파괴적 방법이 사용되고 있다. 본 논문에서는 보온재 내부에서 발생하는 보온재하 부식(CUI : Corrosion Under Insulation)을 유도초음파를 사용하여 효과적으로 검출하기 위해서 유도초음파의 위상속도 분산선도와 파형구조의 이론적 해석을 통해 최적 발생조건을 선정하고자 하였다. 본 연구의 결과는 다양한 석유화학플랜트 배관의 보온재하 부식에 대한 유도초음파를 이용한 현장검출에 적용할 경우 매우 유용할 것이다.

혼화재를 사용한 콘크리트 구조체의 비파괴 시험에 의한 장기재령 압축강도 추정 (Estimation of Long-term Aging Compressive Strength Through Non-Destructive Testing of Concrete Structure Using Mineral Admixtures)

  • 김정섭;신용석;이창현;이승중;김광석
    • 한국건축시공학회지
    • /
    • 제11권5호
    • /
    • pp.426-434
    • /
    • 2011
  • 최근, 혼화재를 사용한 콘크리트는 많은 실험실에서 콘크리트에 연구되고 있으며 실제로 건설 현장에 적용되고 있다. 하지만 혼화재를 사용한 콘크리트의 압축 강도의 추정에 대한 체계적인 연구 결과가 존재하지 않기 때문에 일본의 보통 강도 콘크리트에 대한 제안식을 사용하고 있다. 그래서 혼화재를 사용한 콘크리트의 압축 강도의 추정에 대한 비파괴 시험식을 제안하는 것이 필수적입니다. 따라서 본 연구는 혼화재 사용한 콘크리트에 대하여 원주형 공시체와 코어채취용 구조체를 제작하여 비파괴 시험과 파괴 시험을 통해 장기 재령(4년)에 대한 강도 추정식을 제안한 것으로, 그 결론은 다음과 같다. 기존 제안식과 본 연구 추정식의 오차율을 비교한 결과, 재령별로 다소 차이는 있지만 반발 경도법에 의한 기존 제안식보다는 0.3 %~115.0 % 정도, 초음파속도법에 의한 기존제안식보다는 0.2 %~22.8 % 정도, 복합법에 의한 기존제안식보다는 0.5 %~102.3 % 정도로 기존의 제안식보다 본 연구의 추정식 오차율이 감소하여 혼화재를 사용한 콘크리트에 사용이 바람직할 것으로 판단된다.

Effects of exploration and molecular mechanism of CsV on eNOS and vascular endothelial functions

  • Zuo, Deyu;Jiang, Heng;Yi, Shixiong;Fu, Yang;Xie, Lei;Peng, Qifeng;Liu, Pei;Zhou, Jie;Li, Xunjia
    • Advances in nano research
    • /
    • 제12권5호
    • /
    • pp.501-514
    • /
    • 2022
  • This study aimed to investigate the effects and potential mechanisms of Chikusetsusaponin V (CsV) on endothelial nitric oxide synthase (eNOS) and vascular endothelial cell functions. Different concentrations of CsV were added to animal models, bovine aorta endothelial cells (BAECs) and human umbilical vein endothelial cells (HUVECs) cultured in vitro. qPCR, Western blotting (WB), and B ultrasound were performed to explore the effects of CsV on mouse endothelial cell functions, vascular stiffness and cellular eNOS mRNA, protein expression and NO release. Bioinformatics analysis, network pharmacology, molecular docking and protein mass spectrometry analysis were conducted to jointly predict the upstream transcription factors of eNOS. Furthermore, pulldown and ChIP and dual luciferase assays were employed for subsequent verification. At the presence or absence of CsV stimulation, either overexpression or knockdown of purine rich element binding protein A (PURA) was conducted, and PCR assay was employed to detect PURA and eNOS mRNA expressions, Western blot was used to detect PURA and eNOS protein expressions, cell NO release and serum NO levels. Tube formation experiment was conducted to detect the tube forming capability of HUVECs cells. The animal vasodilation function test detected the vasodilation functions. Ultrasonic detection was performed to determine the mouse aortic arch pulse wave velocity to identify aortic stiffness. CsV stimulus on bovine aortic cells revealed that CsV could upregulate eNOS protein levels in vascular endothelial cells in a concentration and time dependent manner. The expression levels of eNOS mRNA and phosphorylation sites Ser1177, Ser633 and Thr495 increased significantly after CsV stimulation. Meanwhile, CsV could also enhance the tube forming capability of HUVECs cells. Following the mice were gavaged using CsV, the eNOS protein level of mouse aortic endothelial cells was upregulated in a concentration- and time-dependent manner, and serum NO release and vasodilation ability were simultaneously elevated whereas arterial stiffness was alleviated. The pulldown, ChIP and dual luciferase assays demonstrated that PURA could bind to the eNOS promoter and facilitate the transcription of eNOS. Under the conditions of presence or absence of CsV stimulation, overexpression or knockdown of PURA indicated that the effect of CsV on vascular endothelial function and eNOS was weakened following PURA gene silence, whereas overexpression of PURA gene could enhance the effect of CsV upregulating eNOS expression. CsV could promote NO release from endothelial cells by upregulating the expression of PURA/eNOS pathway, improve endothelial cell functions, enhance vasodilation capability, and alleviate vessel stiffness. The present study plays a role in offering a theoretical basis for the development and application of CsV in vascular function improvement, and it also provides a more comprehensive understanding of the pharmacodynamics of CsV.

선형 탐촉자에서 관심 시각 영역 변화에 따른 화질 분석 (Image Quality Analysis According to the of a Linear Transducer)

  • 박지나;한재복;곽종길;송종남
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.975-984
    • /
    • 2022
  • 선형 탐촉자는 탐촉자의 길이만큼의 관심 영역을 갖기 때문에 장비에 탑재된 virtual convex 기능을 사용하여 관심 영역을 확장 시킬 수 있다. 하지만 관심 시각 영역의 변화에 따라 초음파 음속 방향의 변화로 인해 화질에 영향을 미칠 것으로 생각되어 이를 객관적으로 확인하고자 하였다. 본 연구를 위해 초음파 정도 관리용 팬텀의 영상 평가와 SNR·CNR을 측정하였다. 그 결과 팬텀 영상 평가에서는 두 영상 모두 기능적 분해능, 회색조 및 동적 범위에서 모두 구조물 식별이 가능했다. 하지만 구조물의 크기와 형태 재현성에는 Standard 영상이 우수한 것을 확인할 수 있었다. SNR·CNR 평가결과, 특정 위치의 구조물을 제외하고는 대부분이 Trapezoidal 영상의 SNR·CNR이 낮았다. 또한, 통계 분석 그래프를 통해 낭성 구조물의 크기가 작아질수록 깊이별 SNR과 CNR이 감소하는 것을 추가로 확인할 수 있었다. 본 연구를 통해 기능사용이 넓은 관심 시각 영역을 제공하는 장점이 있으나 화질에 영향을 준다는 것을 확인할 수 있었으며 Virtual Convex 기능사용 시 검사자는 이를 적절한 상황에 사용하고 질 높은 영상 획득과 장비의 이해도와 숙련도 향상을 위해 다양한 연구를 해야 할 것으로 판단된다.

초음파 신호의 2차원 역추적 방법에 관한 연구 (2D Backtracking Method of Ultrasonic Signal)

  • 이규정;이충호
    • 융합신호처리학회논문지
    • /
    • 제24권3호
    • /
    • pp.172-177
    • /
    • 2023
  • 본 논문에서는 초음파 신호의 2차원 역추적 방법을 제안한다. 초음파 센서는 송수신 장치를 서로 쌍으로 이용하여 거리 측정 및 실내 위치 추적에 많은 연구가 되어 산업 분야에 쓰이고 있는 보편적인 기술이다. 본 논문에서는 초음파 신호를 수신기만 활용하여 임의의 초음파 송신 장치들의 신호원을 2차원 평면상으로 추적하는 방법을 제안한다. 초음파 신호를 추적하기 위해 수신기는 최소 3개를 이루어 신호를 수신한다. 3개의 수신기는 각각의 초음파 수신음의 도달 시간차를(Time Difference of Arrival, TDOA) 이용하여 방향 및 거리를 연산할 수 있다. 기존 초음파를 이용한 신호원 추적 방법은 송수신기가 쌍으로 이루어지거나 센서마다 독립적으로 설치가 되어야 하기 때문에 장치들의 시간 동기화가 문제가 있다. 이 문제를 해결하기 위해 초음파 수신기의 거리를 최소화하여 설치고 하나의 장치로 구성한다. 하나의 장치로 설치된 센서는 하나의 연산기로 처리하기에 시간 동기화 문제를 해결할 수 있다. 시간차 정확도를 올리기 위해 시간 분해능이 높은 고속 32비트 타이머를 사용하여 거리 및 방향을 빠르게 연산 및 추적할 수 있다.