• Title/Summary/Keyword: ultrasound technology

Search Result 495, Processing Time 0.029 seconds

Effects of Body Condition Score and Estimation of Growth Curves for Chest Girth and Ultra Sonic Longissimus Muscle Area, Backfat Thickness and Marbling Scores in Hanwoo(Korean cattle) Cows (한우 암소의 흉위, 초음파 측정 배장근단면적, 등지방두께, 근내지방도에 대한 발육곡선 추정 및 신체충실지수 효과)

  • Lee, Deuk-Hwan;Lee, Gil-Hwan;Cho, Chung-Il;Kim, Nae-Soo
    • Journal of Animal Science and Technology
    • /
    • v.50 no.5
    • /
    • pp.581-590
    • /
    • 2008
  • Growth curves for ultrasonic carcass traits such as longissimus muscle area, backfat thickness and marbling score as well as chest girth which was simultaneously measured when carcass traits were investigated using ultrasound measuring technique were estimated to identify growth patterns and to adjust maturing effects in order to evaluating genetic merits on cows in farming basis. 27,410 records from 22,451 cows on which of 15~90 month of age were investigated from the national wide of Korea using by ultrasonic scanning techniques by the skilled persons from 2002 to 2007. Van Bertalanffy growth function was applied for estimating growth curves on these traits. Carcass traits and chest girth would be linearly increased by body condition score. It might be used for multiplicative correction factors for pre- adjustment on the body condition scores. Growth pattern on chest girth would be quickly reached to mature size and stable on after reached to asymptotic mature size. Longissimus muscle area would also be reached to mature size but little smoother than chest girth. Otherwise, growth curve on backfat thickness would be steadily increasing up to 7 years of age. It also showed large individual difference by way of mean square error. Marbling score would be steadily increased but sharper than those on backfat thickness. It would be reached to mature size up at 5 years of age. Those growth curves would be used for correcting function on age at investigating on genetic evaluation system.

Endoscopic Bio-Imaging Using Optical Coherence Tomography (마이크로 내시경 및 첨단 광 단층촬영기법을 이용한 생체 이미징)

  • Ahn, Yeh-Chan;Brenner, Matthew;Chen, Zhongping
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.466-471
    • /
    • 2011
  • Optical coherence tomography(OCT) is an emerging medical diagnostic tool that draws great attention in medical and biological fields. It has a 10-100 times higher spatial resolution than that of the clinical ultrasound but lower imaging depth such as 1-2 mm. In order to image internal organs, OCT needs an endoscopic probe. In this paper, the principle of Fourier-domain optical coherence tomography with high-speed imaging capability was introduced. An OCT endoscope based on MEMS technology was developed. It was attached to the Fourier-domain OCT system to acquire three-dimensional tomographic images of gastrointestinal tract of New Zealand white rabbit. The endoscope had a two-axis scanning mirror that was driven by electrostatic force. The mirror stirred an incident light to sweep two-dimensional plane by scanning. The outer diameter of the endoscope was 6 mm and the mirror diameter was 1.2 mm. A three-dimensional image rendered by 200 two-dimensional tomographs with $200{\times}500$ pixels was displayed within 3.5 seconds. The spatial resolution of the OCT system was 8 ${\mu}m$ in air.

The effect of hypersonic wave sound for EEG (초음파가 뇌파에 미치는 영향)

  • Jang, Seok Woo;Park, In Gil;Kim, Dae Kyeum;Choi, Hyun
    • Science of Emotion and Sensibility
    • /
    • v.17 no.2
    • /
    • pp.101-110
    • /
    • 2014
  • High-frequency is sound produced in non-audible area, which couldn't be heard in daily life. The frequency range above 22Khz is called 'high-frequency' and its components are called 'HFC(High-Frequency Components)'. It is known that ocean wave sound is rich in HFC, because it brings serenity and causes ${\alpha}$-waves in human mind. When this natural sound is combined with high-frequency, it seems to give a pleasurable feeling, indicated by an ${\alpha}$-wave increase and a ${\beta}$-wave decrease. We call this phenomena "the hypersonic effects". In this experiment, subjects listened to the ocean wave sound simultaneously with corresponding frequencies similar to ocean wave frequency components created artificially in a electric circuit. Brain waves were measured by an EEG system with 8 channels using 8 electrodes on Fp1, Fp2, F3, F4, T3, T4, O1, and O2. The results showed that ${\alpha}$-wave increase and ${\beta}$-wave decrease were statistically significant while subjects were listening to the ocean wave sound along with the high frequency components, reflecting the hypersonic effect.

The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가)

  • Lee, Dong-Hun;Yoo, Hee-Jae;Lee, Jong-Hun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

Antioxidant and whitening effects of loquat (Eriobotrya japonica) fruit extracts (비파(Eriobotrya japonica) 열매 추출물의 산화방지능과 미백 효과)

  • Yun, Min-Kyu;Park, Gi-Cheol;Cho, Youn-Sup;Kim, Dae-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.54 no.3
    • /
    • pp.280-287
    • /
    • 2022
  • The loquat (Eriobotrya japonica) is a fruit tree belonging to the Rosaceae family. Loquat fruit extracts from three cultivars (Tanaka, Mogi, and Jinwang) were prepared using absolute methanol and homogenization and ultrasound sonication procedures. We measured the total phenolic and flavonoid content of the fruit extracts and their antioxidant capacities. In addition, we evaluated tyrosinase activity and anti-melanogenic effects in B16F1 melanoma cells. The fruit extract from cv. Tanaka had the highest total phenolic content and showed the highest antioxidant capacity in the ABTS assay. The loquat fruit extract from cv. Jinwang had the highest total flavonoid content and showed the highest antioxidant capacity in the DPPH assay. Loquat fruit extracts from the Tanaka and Jinwang cultivars effectively inhibited mushroom tyrosinase activity. The loquat fruit extracts reduced intracellular oxidative stress in B16F1 melanoma cells. Treating B16F1 melanoma cells with loquat fruit extract from cv. Tanaka at a concentration of 125 ㎍/mL effectively inhibited melanin synthesis. However, treating the B16F1 melanoma cells with loquat fruit extracts from the Jinwang and Mogi cultivars did not. These results suggest that loquat fruit extracts from the Tanaka cultivar may serve as potential sources of antioxidants and act as a skin-whitening agent.

Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems (집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰)

  • Kim, Jun-tae;Kim, Ju-hee;Joo, Kyu-tai;Kim, Kyung-ah;Ryu, Ok-su;Jo, Jae-hyun;Jeong, Jin-Hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.164-177
    • /
    • 2022
  • Medical device usability evaluation refers to the evaluation of medical devices through actual users before the final prototype production is completed. IEC 62366, one of the international safety standards for electronic medical devices, is a standard that must be applied to obtain medical device licenses in major advanced countries such as Europe and the United States. In Korea, through the Ministry of Food and Drug Safety's notice, from January 2021, sequential application by grade has been implemented. In this study, 15 participant specialists were recruited through the Incheon G University Hospital Medical Device Convergence Center for formative evaluation during user suitability evaluation of the focused ultrasound stimulation system being developed by Icleo Co., Ltd., and the test was conducted through joint scenario development. . In the result of task performance, the performance rate was 90.67%, and after the completion of the performance, 86.67% of 'Easy user interface' and 94% of 'Identification/Readability/Understanding of information' questions in the participant survey results analysis by question. The response rate was above average.

Efficiency of Equilume light mask on the resumption of early estrous cyclicity and ovulation in Thoroughbred mares

  • Kim, Seongmin;Jung, Heejun;Murphy, Barbara Anne;Yoon, Minjung
    • Journal of Animal Science and Technology
    • /
    • v.64 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Equilume light masks had no impact on hastening the resumption of estrous cyclicity in mares maintained in outdoor pastures on the mainland of Korea due to the cold weather conditions. Jeju Island is a major horse-breeding site in Korea and is warmer than the mainland during the winter season. Therefore, the primary objective of this study was to explore the efficiency of the Equilume light mask on the resumption of seasonal estrous cycles in Thoroughbred mares on Jeju Island. A total of 20 nonpregnant mares were randomly divided into the Equilume light mask (n = 9) and stable lighting (n =11) groups. The experiment was performed at seven different horse-breeding farms located on Jeju Island from November 15, 2020, to February 15, 2021. The mares were exposed to the respective lights from 16:00 to 23:00. Follicle size and uterine edema were measured by ultrasound scanning. Body condition scores (BCS) were also monitored during the experiment. Statistical analysis was conducted using the SAS and SPSS software, and p-values of < 0.05 were considered statistically significant. Two of the nine (22.2%) mares in the Equilume light mask group and three of the 11 (27.28%) mares in the stable lighting group were still cycling in December and January, which were considered as all-year-round cycling mares. On February 15, there was no difference between groups in the resumption of early seasonal estrus cycle, which was determined by follicles > 25 mm in addition to uterine edema. All mares in the Equilume light mask group and five of the eight mares (62.5%) in the stable lighting group had resumed cycling. Interestingly, six of the seven mares (87.5%) in the Equilume light mask and four of eight mares (50%) in the stable lighting group had already ovulated on February 15 (p > 0.05), as determined by the presence of a recent corpus luteum. No difference was observed in BCS and uterine edema between groups (p > 0.05). In conclusion, the Equilume light mask can be an effective approach to induce early seasonal estrus cycles of mares in Jeju Island, and it also enhances the efficiency of farm management by reducing labor.

Studies on Variation of Characteristics in Hanwoo Steers by Pen and Group Size (한우 거세우의 군집크기에 따른 산육특성 연구)

  • Ha, J.J.;Rhee, Y.J.;Jang, W.J.;Kim, Y.W.;Shaogang, Li;Song, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • This study, tasting 14 months, was conducted to investigate the effects of different pen size and group size on growing-fattening characteristics of Hanwoo steers. Forty-eight, 12-month-old Hanwoo steers($305.8{\pm}32.2\;kg$) were randomly assigned to three groups($35.28\;m^2$; n=4 heads, $70.56\;m^2$; n=8 heads, $105.84\;m^2$; n=12 heads) and reared in separate pens with a constant space allowance of $8.82m^2$ per head from 12 to 21 month of age and then regrouped to 4 heads per pen. A common diet including concentrate(limited) and forage(ad lib) was provided to all the animals. Images of live animal ultrasonic back fat thickness, longissimus muscle area and Marbling score were evaluated in three months interval from 12 months of age using an ultrasound equipment(HS-2000) at the 13th rib and lumber vertebra interface of left side. Significant differences of ADG was found mainly at $15{\sim}18$ month and $18{\sim}21$ month fattening stages(p<0.05). Marbling score(MS) was higher(p<0.05) in 12 heads group when compared with that of 4 and 8 heads groups after 18 months. Animals in 12 heads group had the lowest Average daily gain(ADG) but showed the highest longissimus muscle area(LMA) and marbling score(MS). In addition, Hanwoo steers in 12 heads group obtained a higher quality appearance(HQA) of 82.7% than that of other treatments. The results indicated that Hanwoo steers housed on large group size and pen size decreased their ADG but improved meat quality.

  • PDF

The Study on the Factors for Detection of Renal Stone on Ultrasound (초음파 검사에서 신장 결석의 검출 요인에 관한 연구)

  • Sim, Hyun-Sun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Purpose: Renal stones are common and typically arise within the collecting system. The renal sinus are contains the collection system, the renal vessels, lymphatcs, fat, and fibrous tissue. Because of the compression of all the large echoes in signal processing, the echo from the renal stone generally cannot be distinguished from large echoes emanating from normal structures of the renal sinus. Use of ultrasonography has been difficult for detecting small renal stone without posterior shadowing and chemical composition of stone. The aim of study was measuring for posterior acoustic shadowing to a stone for various scan parameter and it examines a help in renal stone diagnosis. Material & Methods: The stone was place on sponge examined in a water bath with a 3.5MHz or 7.5MHz transducer(LOGIQ 400, USA). First, tested a variety of gain. Second, tested a variety of dynamic range. Third, tested a variety of focal zone. Fourth, measuring of the echo level for low and high frequency for depth. Results: 1) Average echo level was 98 for low total gain(10 dB) and was 142 for high total gain(40 dB). Posterior acoustic shadowing of renal stone was clear for low gain. 2) Average echo level was 129 for low dynamic range(42 dB) and was 101 for high dynamic range(72 dB). Posterior acoustic shadowing of renal stone was clear for high dynamic range. 3) When stone is in focal zone of transducer, definite posterior acoustic shadow is identified. 4) Stone was clear appeared for high frequency(7.5 MHz) than low frequency(3.5 MHz) and it is not distorted. Conclusion: The demonstration of an posterior acoustic shadow of renal stone dependents on several technical factors such as gain, dynamic range, focus, and frequency. This various factors are a help in renal stone diagnosis.

  • PDF

A Study on the Necessity Verification of Convex Probe Disinfection (Convex Probe 소독 필요성 검증에 관한 연구)

  • Choi, Kwan-Yong;Yoo, Se-jong;Lee, Jun-ho;Hong, Sung-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.193-200
    • /
    • 2019
  • The study was conducted surveying ultrasound room workers on hospital infection awareness in Daejeon and Choong-chunng region. The contamination of ultrasonic probes used in clinical trials was measured using ATP, and the results were verified after using 70% alcohol sterilization. It was measured on the group's general characteristics and the specific categories such as academic background, job type, having professional certificate and infection education. After the examination, the gel removal and method, disinfection status of the probe and variable correlation analysis were performed to analyze the recognition of the ultrasonic probe disinfection. After examination in ultrasound room, it was found that towels were used the most for cleaning, and the gel container was not replaced for more than three months. After 70% alcohol disinfection, ATP contamination was reduced from $1055.4{\pm}944.2$ to $133.5{\pm}93.2$ and the result was analyzed to be statistically significant.(${\rho}<0.01$) The found bacteria were CNS, Gram positive bacillus, and Micrococcus specs. In order to solve this problem, 70% alcohol sterilization was applied and the bacteria were not detected after the treatment. The research shows that regular training on infection control and efforts to prevent infection are necessary, and that 70% alcohol is effective in disinfect the bacteria. Therefore, the medical institution should provide active hospital infection control education to improve the awareness of hospital infection among workers and contribute to the prevention of patient infection. It is also understood that proper use of the results of this study will help prevent infection by means of ultrasonic probes.