• Title/Summary/Keyword: ultrasound imaging

Search Result 675, Processing Time 0.026 seconds

Giant Lipoma in the Lateral Neck Causing Internal Jugular Vein Deformity (내경정맥의 변형을 유발한 거대 경부 지방종)

  • Jun Ho, Choi;Sang Seong, Oh;Kwang Seog, Kim;Jae Ha, Hwang;Sam Yong, Lee
    • Korean Journal of Head & Neck Oncology
    • /
    • v.38 no.2
    • /
    • pp.29-32
    • /
    • 2022
  • Lipoma is one of the most common benign soft tissue tumors. However, giant lipomas compressing and deforming the neurovascular structure rarely occur in the lateral neck. A 70-year-old man visited our outpatient clinic for treatment of a visible painless neck mass that had been identified 2 years prior. Neck magnetic resonance imaging revealed that a 10 × 9 × 4 cm fatty mass located between the sternocleidomastoid and sternohyoid muscles invaded the carotid sheath. Under general anesthesia, the mass was excised without damage to the adjacent neurovascular structures. Upon histopathological examination, the mass was identified as a lipoma. During the surgery, enlargement of the internal jugular vein was observed under the resected mass. However, on ultrasound examination, the function of the internal jugular vein was evaluated as good. No recurrence or neurological and vascular complications were reported during a 6-month follow-up after the surgery. As a giant lipoma located in the deep layer of the lateral neck can deform important cervical structures, its impact on the surrounding structures should be carefully assessed preoperatively to minimize the rate of possible complications.

A Study on the History of the Korean Medical Device Industry and its Global Competitiveness (한국 의료기기 산업의 역사와 국제 경쟁력 고찰)

  • Yeom, Hojun;Jeong, Hyun-Woo;Park, Sangsoo
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.1-7
    • /
    • 2022
  • Korean medical device industry has laid the foundation for full-fledged growth and development with the G7 medical engineering technology development project that started in 1995, and the medical device production in 2020 increased by 8.52 times and the export by 13.94 times, compared to those in 2001. In early years, electronic medical devices such as ultrasound imaging device contributed greatly to Korean medical industry, but top ranks in medical device production and export in Korea has shifted recently to in vitro diagnostic medical devices and dental implants. However, the share of imported medical devices in the Korean medical device market have not changed much; it still ranges in 60 to 70%, as the Korean medical device industry produces and exports mid- to low-priced medical devices, and technology-intensive and capital-intensive high-priced medical devices are mainly imported. In this paper, we compare the leading medical devices produced by major Korean companies and those by global top medical device companies to suggest strategies for the Korean medical device companies to enter the global market.

Should Korean Medicine doctors use modern diagnostic medical devices? Survey result of public perspectives (국민인식을 기초로 한의사의 현대 진단의료기기 사용 법제화 필요성에 대한 제언 : 설문조사를 중심으로)

  • Juchul Kim;Byoungcheun Hwang;Manki Hwang;Seungmin Kathy Lee;EunHee Yi;Jungtae Leem
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.94-105
    • /
    • 2022
  • Objectives: This study investigated public opinion on the use of modern diagnostic medical devices by Korean Medicine doctors. Methods: A questionnaire looking into perceptions on the use of modern medical devices was developed. It was distributed by a third party and data was collected. Results were analyzed through frequency analysis, chi-square analysis (χ2-test), frequency and cross analysis using R program. The measurement variable in the study was the respondent's perspectives and expectations on the use of modern diagnostic medical devices by Korean Medicine doctors. The maximum significance level was 0.05. Results: There were a total of 3,000 responses and 80.8% of the respondents replied that there is a need for government-level discussion on endowing rights to Korean Medicine doctors as supervisors for safety management of radiation generating devices. Also, 83.3% of the respondents agreed the use of ultrasound imaging equipment in Korean Medicine clinics should be legalized. Conclusions: According to this study, respondents strongly support the use of modern diagnostic medical devices by Korean Medicine doctors. This is the first study to investigate public opinion in this area and it provides a significant insight into the public needs and desires for a wider scope of practice for Korean Medicine in the healthcare system.

Comparison of the Ratio of Thicknesses of the Rhomboid Major and Middle Trapezius Muscles While Performing Scapular Retraction Exercises (어깨뼈 뒤 당김 운동 방법에 따른 큰마름근과 중간등세모근의 근두께비의 비교)

  • Park, Heon-mi;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • Background: Shoulder impingement syndrome, a major cause of shoulder pain, involves weakness of the scapular retractor muscles. The major scapular retractor muscles are the middle trapezius and rhomboid major muscles; however, the latter is excluded in most studies. Objects: We aimed to measure the thickness of the middle trapezius and rhomboid major muscles using an ultrasonic diagnostic imaging system while performing four different shoulder retraction exercises and comparing the thicknesses and ratio of the thicknesses of these muscles. Methods: The thickness of the middle trapezius and rhomboid major muscles was measured in 24 healthy adults using ultrasound. Muscle thickness was measured three times in the Reference posture and four times while performing four different exercises that involved scapular retraction. The averages and standard deviations of the measured muscle thicknesses were obtained and compared. The ratio of muscle thickness and rate of changes in muscle thickness between the reference posture and the four exercises were compared. Results: For both, male (n = 10) and female (n = 14), there was a significant difference in the thickness of the middle trapezius muscle between the reference posture and the four exercises (p < 0.05) and in the thickness of the middle trapezius and rhomboid major muscles between male and female (p < 0.05); however, there was no significant difference in the ratio of the thicknesses of these muscles. Although a significant difference in the rate of change in muscle thickness during the four exercises was noted, there was no significant difference in the ratio of change in muscle thickness. Conclusion: This study demonstrates the ratio of the thicknesses of the middle trapezius and rhomboid major muscles and the rate of change in their thickness during exercises involving scapular retraction in healthy people in their 20s-30s.

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

Effects of Core Exercise on Body Composition, Abdominal Muscle Thickness, Trunk Muscular Endurance, and Psychological Factors in Normal-weight Obese Women (코어운동이 마른 비만 여성의 신체조성과 복부 근육두께, 몸통 근지구력, 심리적 요인에 미치는 영향)

  • Sang Ho Kim;Tae Hwa Seo;Nam Gi Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.3
    • /
    • pp.72-83
    • /
    • 2023
  • Background: Normal-weight obese women have a normal weight with relatively low muscle mass resulting from high body fat. We aimed to investigate the effects of core exercise on body composition, abdominal muscle thickness, trunk muscular endurance, and psychological factors in normal-weight obese women. Design: One group pre-, mid-, and post-test design. Methods: A total of 20 normal-weight obese women were recruited voluntarily. Core exercises were performed for 30 minutes, three times a week for 4 weeks. InBody measurements, ultrasound imaging, and clinical tests were used to assess body composition, abdominal muscle thickness, trunk and core muscular endurance, and psychological condition(satisfaction with appearance and self-esteem). The dependent variables were measured three times: before the intervention (pre-test), 2 weeks after the intervention (mid-test), and 4 weeks after intervention (post-test). One-way repeated measures ANOVA and Friedman test were used for statistical analysis. Results: Although there was no change in the body composition (p>0.05), thickness of the transversus abdominis and internal and external oblique muscles, endurance of the trunk flexors and extensors and core muscles, and psychological condition showed significant differences after the intervention (p<0.05). Conclusion: Our findings will help develop exercise programs for normal-weight obese individuals that utilize the beneficial effect of core exercises.

A Comparison of Gluteus Maximus Muscle and Biceps Femoris Muscle Thickness According to Weight Load during Prone Hip Extension with Knee Flexion Exercises (엎드려 무릎관절 굽힘 자세에서 엉덩관절 폄 동작 시 무게 부하 변화에 따른 큰볼기근과 넙다리두갈래근의 두께 비교)

  • Eun-Mi Jang;Da-Eun Jung
    • PNF and Movement
    • /
    • v.21 no.3
    • /
    • pp.309-317
    • /
    • 2023
  • Purpose: This study set out to investigate the effects of prone hip extension with knee flexion (PHEKF) exercises according to external load on the thickness of the gluteus maximus (Gmax) and biceps femoris (BF). Methods: Twenty-three healthy men participated in this study. All subjects randomly practiced PHEKF under the burden of external loads created by sandbags (0 kg, 1 kg, and 2 kg). Rehabilitative ultrasound imaging (RUSI) was used to measure the thickness of the Gmax and BF during the PHEKF with different external loads. Results: The thickness of the Gmax was highest during the 2 kg resistance exercise and lowest at 0 kg. The thickness of the Gmax was significantly increased at 1 kg and 2 kg compared to 0 kg and significantly increased at from 1 kg to 2 kg (p < 0.05). The thickness of the biceps femoris was highest at 0 kg and lowest at 2 kg. The thickness of the biceps femoris muscle was significantly reduced at 1 kg and 2 kg compared to 0 kg (p < 0.05), but there was no significant difference between 1 kg and 2 kg (p > 0.05). Conclusion: The thickness of the Gmax was increased by applying PHEKF with a higher external load, whereas the muscle thickness of the biceps femoris decreased. These results suggest that the application of external loads during PHEKF exercises may be an effective method for selective strengthening of the Gmax.

Influences of the Defective Piezo-Elements of a Medical Ultrasonic Probe on Transient Acoustic Fields and B-Mode Images (의료용 초음파프로브의 압전소자 결함이 과도음장과 B-모드 영상에 미치는 영향)

  • Choi, Kwang-Yoon;Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Soon;Yang, Jeong-Hwa;Kang, Gwan-Suk;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.476-482
    • /
    • 2010
  • The ultrasonic transient fields and B-mode images of a point target which were simulated for a medical ultrasonic probe with a few defective piezo-elements were compared with those for a normal probe. The present study considered a 3.5 MHz linear array probe whose acoustic beam was formed by the 64 active elements of total 192 elements. The results showed that the maximum amplitude and -3 dB width of the acoustic fields by main-lobes decreased linearly as the defective element number increased from one to four. However, the depths of foci remained almost unchanged, and the pressure differences between main-lobes and side-lobes tended to decrease due to rise in pressures in side-lobes. Such changes in ultrasonic fields affected the B-mode images of point targets. So the artifacts were formed in the right and left side of the target, and the lateral spatial resolutions were decreased while the axial resolution was almost the same.

Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler (혈관협착팬텀의 제작 및 파워도플러의 영상 평가)

  • Park, Hee-Young;Bae, Jong-Rim;Kim, Jeong-Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.732-739
    • /
    • 2009
  • Flow phantom with stenosis was manufactured using an auto-injector to obtain angiostenotic flow information and quality assurance (QA) for ultrasound diagnostic instrumentation. Effectiveness of manufactured flow phantom with stenosis was investigated with power Doppler that was known to have diagnostic efficiency for angiostenosis. The flow phantom with stenosis was manufactured to 70% stenosis with 8 mm and 2.4 mm silicon tube, and silicone tube was covered with gelatin that has acoustic characteristics similar to soft tissue. When the linear transducer was used for measurement, the estimated diameter of normal vessel was measured lower than that of normal value, and the estimated diameter of stenosed vessel was measured higher than that of normal value. The measured parameters were not affected except for the radical conditions such as gain of 60%, PRF of 3000 Hz, use of maximal filter or angle. In addition, when the convex transducer was used for measurement, measurement parameters were affected by gain, PRF, filter, and angle. Therefore it is expected that flow phantom with stenosis manufactured with an auto-injector will be utilized effectively for QA of angiostenotic diagnosis.

A Case Report of Axillary Hibernoma: US, CT, MR, and Histopathologic Findings (액와부 갈색지방종의 증례 보고: 초음파, 컴퓨터단층촬영, 자기공명영상, 병리 소견)

  • Ji Yeon Park;Seong Yoon Yi;Ji Young Lee;Tae Jung Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.439-443
    • /
    • 2022
  • Hibernoma is a rare benign tumor of brown adipose tissue. Herein, we report a case of axillary hibernoma in a 53-year-old female and discuss the various radiologic findings. The US revealed a 4.5-cm well-defined oval heterogenous hyperechoic mass in the right axilla with anterior displacement of the axillary vessels. Non-enhanced chest CT showed a 5.0-cm well defined, oval, and low-attenuated mass. MRI demonstrated a 5.5-cm mass with heterogeneous intermediate-to-high signal intensity on T1-and T2-weighted images and irregular enhancement at the peripheral portion. The patient underwent an US-guided core needle biopsy and the final diagnosis was hibernoma.