• 제목/요약/키워드: ultrasound energy

검색결과 188건 처리시간 0.027초

Development of High Intensity Focused Ultrasound (HIFU) Mediated AuNP-liposomal Nanomedicine and Evaluation with PET Imaging

  • Ji Yoon Kim;Un Chul Shin;Ji Yong Park;Ran Ji Yoo;Soeku Bae;Tae Hyeon Choi;Kyuwan Kim;Young Chan Ann;Jin Sil Kim;Yu Jin Shin;Hokyu Lee;Yong Jin Lee;Kyo Chul Lee;Suhng Wook Kim;Yun-Sang Lee
    • 대한방사성의약품학회지
    • /
    • 제9권1호
    • /
    • pp.9-16
    • /
    • 2023
  • Liposomes as drug delivery system have proved useful carrier for various disease, including cancer. In addition, perfluorocarbon cored microbubbles are utilized in conjunction with high-intensity focused-ultrasound (HIFU) to enable simultaneous diagnosis and treatment. However, microbubbles generally exhibit lower drug loading efficiency, so the need for the development of a novel liposome-based drug delivery material that can efficiently load and deliver drugs to targeted areas via HIFU. This study aims to develop a liposome-based drug delivery material by introducing a substance that can burst liposomes using ultrasound energy and confirm the ability to target tumors using PET imaging. Liposomes (Lipo-DOX, Lipo-DOX-Au, Lipo-DOX-Au-RGD) were synthesized with gold nanoparticles using an avidin-biotin bond, and doxorubicin was mounted inside by pH gradient method. The size distribution was measured by DLS, and encapsulation efficiency of doxorubicin was analyzed by UV-vis spectrometer. The target specificity and cytotoxicity of liposomes were assessed in vitro by glioblastoma U87mg cells to HIFU treatment and analyzed using CCK-8 assay, and fluorescence microscopy at 6-hour intervals for up to 24 hours. For the in vivo study, U87mg model mouse were injected intravenously with 1.48 MBq of 64Cu-labeled Lipo-DOX-Au and Lipo-DOX-Au-RGD, and PET images were taken at 0, 2, 4, 8, and 24 hours. As a result, the size of liposomes was 108.3 ± 5.0 nm at Lipo-DOX-Au and 94.1 ± 12.2 nm at Lipo-DOX-Au-RGD, and it was observed that doxorubicin was mounted inside the liposome up to 52%. After 6 hours of HIFU treatment, the viability of U87mg cells treated with Lipo-DOX-Au decreased by around 20% compared to Lipo-DOX, and Lipo-DOX-Au-RGD had a higher uptake rate than Lipo-DOX. In vivo study using PET images, it was confirmed that 64Cu-Lipo-DOX-Au-RGD was taken up into the tumor immediately after injection and maintained for up to 4 hours. In this study, drugs released from liposomes-gold nanoparticles via ultrasound and RGD targeting were confirmed by non-invasive imaging. In cell-level experiments, HIFU treatment of gold nanoparticle-coupled liposomes significantly decreased tumor survival, while RGD-liposomes exhibited high tumor targeting and rapid release in vivo imaging. It is expected that the combination of these models with ultrasound is served as an effective drug delivery material with therapeutic outcomes.

초음파 캐비테이션에 의해 생성되는 라디칼의 발생량 평가를 위한 소노루미네센스 발광강도의 측정 (Measurement of sonoluminescence intensity for evaluation of the amount of radical generated by ultrasonic cavitation)

  • 김정순;김무준
    • 한국음향학회지
    • /
    • 제42권1호
    • /
    • pp.50-56
    • /
    • 2023
  • 이산화티탄 현탁액에서 초음파 캐비테이션 충격파에 의해 발생하는 하이드록실 라디칼(·OH) 및 슈퍼옥사이드 음이온 라디칼(·O2- )은 살균 및 소독 작용을 할 수 있어 활용 가치가 높다. 화학첨가물이 없는 살균 방법으로서의 실용화를 위하여 본 연구에서는 이산화티탄 현탁액에 방사된 강력 초음파에 의해 발생하는 라디칼의 발생 정도를 평가하는 방법을 제안하였다. 제안된 방법에서는 초음파 붕괴에너지에 의해 발광하는 소노루미네센스 현상을 활용하였고, 소노루미네센스에 의한 빛 에너지의 양을 통해 라디칼 발생 정도를 평가하였다. 그 결과, 이산화티탄의 농도가 0.02 wt%인 낮은 농도에서도, 이산화티탄이 없는 경우보다 5배 이상 높은 빛 에너지가 수광되었다. 그 이후, 농도가 0.1 wt%씩 증가함에 따라 발생하는 소노루미네센스의 광도는 약 14.8×10-12 lm씩 선형적으로 증가하였다. 따라서 이산화티탄 현탁액에 강력 초음파를 방사하여 발생하는 라디칼은, 주어진 농도 범위 내에서 이산화티탄의 농도가 증가함에 따라 선형적으로 증가함을 확인할 수 있었다.

10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석 (Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz)

  • 김종호;홍일곡;신호용;안효준;임종인
    • 한국결정성장학회지
    • /
    • 제33권3호
    • /
    • pp.116-123
    • /
    • 2023
  • 압전 HIFU 트랜스듀서는 바이오 의료분야에 적용되고 있는 새로운 기술로 발생한 초음파 에너지를 열로 변환하여 사용하는 디바이스이다. 최근 HIFU 디바이스는 7 MHz 이상의 고 작동 주파수를 갖는 디바이스를 개발하는 추세이다. 본 논문에서는 유한요소법을 이용해 10MHz 작동주파수를 갖는 HIFU 트랜스듀서에 의해 발생된 tissue에서의 음압 및 온도분포를 계산하고, 압력의 focusing 특성 등을 분석하였다. HIFU의 형상변수로는 압전소재 두께, 렌즈 형상, 물 높이, 필름의 두께 등을 고려하였다. 그 결과, 디바이스의 발생 음압은 렌즈의 HL/RL 비가 증가함에 따라 증가하다 일정한 값에 도달하는 경향을 보이고 있다. 그러나 디바이스의 focusing 면적은 렌즈의 HL/RL 비가 증가함에 급격하게 감소하는 특성을 보이고 있다. 최적 형상을 갖는 HIFU 디바이스의 경우, 최대 음압 및 온도는 각각 19 MPa 및 65도 정도로 분석되었다. 또한 축방향 및 이와 수직한 방향에서 -3 d B 초점 거리는 각각 2.3 mm 및 0.23 mm 정도인 것으로 나타났다

The exfoliation of irradiated nuclear graphite by treatment with organic solvent: A proposal for its recycling

  • Capone, Mauro;Cherubini, Nadia;Cozzella, Maria Letizia;Dodaro, Alessandro;Guarcini, Tiziana
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1037-1040
    • /
    • 2019
  • For the past 50 years, graphite has been widely used as a moderator, reflector and fuel matrix in different kinds of gas-cooled reactors. Resulting in approximately 250,000 metric tons of irradiated graphite waste. One of the most significant long-lived radioisotope from graphite reactors is carbon-14 ($^{14}C$) with a half-life of 5730 years, this makes it a huge concern for deep geologic disposal of nuclear graphite (NG). Considering the lifecycle of NG a number of waste management options have been developed, mainly focused on the achievement the radiological requirements for disposal. The existing approaches for recycling depend on the cost to be economically viable. In this new study, an affordable process to remove $^{14}C$ has been proposed using samples taken from the Nuclear Power Plant in Latina (Italy) which have been used to investigate the capability of organic and inorganic solvents in removing $^{14}C$ from exfoliated nuclear graphite, with the aim to design a practicable approach to obtain graphite for recycling or/and safety disposed as L& LLW.

Comparison of the Therapeutic Efficacy and Technical Outcomes between Conventional Fixed Electrodes and Adjustable Electrodes in the Radiofrequency Ablation of Benign Thyroid Nodules

  • Jae Ho Shin;Minkook Seo;Min Kyoung Lee;So Lyung Jung
    • Korean Journal of Radiology
    • /
    • 제25권2호
    • /
    • pp.199-209
    • /
    • 2024
  • Objective: This study aimed to compare therapeutic efficacy and technical outcomes between adjustable electrode (AE) and conventional fixed electrode (FE) for radiofrequency ablation (RFA) of benign thyroid nodules. Materials and Methods: Between 2013 and 2021, RFA was performed on histologically proven benign thyroid nodules. For the AE method, AE length ≥ 1 cm with higher power and < 1 cm with lower power were utilized for ablating feeding vessels and nodules, especially those near anatomical structures, respectively. The therapeutic efficacy (volume reduction rate [VRR], complication rate, and regrowth rate) and technical outcomes (total energy delivery, ablated volume/energy, RFA time, and ablated volume/time) of FE and AE were compared. Continuous parameters were compared using a two-sample t-test or Mann-Whitney U test, and categorical parameters were compared using a chi-squared test or Fisher's exact test. Results: A total of 182 nodules (FE: 92 vs. AE: 90) in 173 patients (mean age ± standard deviation, 47.0 ± 14.7 years; female, 90.8% [157/173]; median follow-up, 726 days [interquartile range, 441-1075 days]) were analyzed. The therapeutic efficacy was comparable, whereas technical outcomes were more favorable for AE. Both electrodes demonstrated comparable overall median VRR (FE: 92.4% vs. AE: 84.9%, P = 0.240) without immediate major complications. Overall regrowth rates were comparable between the two groups (FE: 2.2% [2/90] vs. AE: 1.1% [1/90], P > 0.99). AE demonstrated a shorter median RFA time (FE: 811 vs. AE: 627 seconds, P = 0.009). Both delivered comparable median energy (FE: 42.8 vs. AE: 29.2 kJ, P = 0.069), but AE demonstrated higher median ablated volume/energy and median ablated volume/time (FE: 0.2 vs. AE: 0.3 cc/kJ, P < 0.001; and FE: 0.7 vs. AE: 1.0 cc/min, P < 0.001, respectively). Conclusion: Therapeutic efficacy between FE and AE was comparable. AE demonstrated better technical outcomes than FE in terms of RFA time, ablated volume/energy, and ablated volume/time.

만성 석회화 건염에 대한 다발성 천공술 후 추가적으로 시행한 체외 충격파 치료의 에너지 수준에 따른 결과분석 (Extracorporeal Shock-wave Therapy after Multiple Drilling as a Treatment for Chronic Calcific Tendinitis - An Analysis of Outcome Following Different Levels of Energy)

  • 노규철;장근종
    • 대한정형외과 초음파학회지
    • /
    • 제5권2호
    • /
    • pp.66-74
    • /
    • 2012
  • 목적: 만성 석회화 건염에 대한 보존적 치료방법으로 석회질 다발성 천공술과 체외 충격파 병합 치료의 효과를 비교하고, 체외 충격파 치료의 에너지 수준에 따른 임상적, 방사선학적 효과에 대하여 알아보고자 하였다. 대상 및 방법: 환자 선정은 2010년 6월부터 2011년 8월까지 어깨 통증으로 내원 후 극상근 만성 석회화 건염으로 진단받은 환자 98명을 대상으로 하였으며, 천공술 후 체외 충격파 치료를 에너지 수준에 따라 고에너지군(제 1군;31명), 저에너지군(제 2군;36명) 및 다발성 천공술 시행군(제 3군;31명) 으로 분류하였다. 보존적 치료에 반응하지 않고, 견관절 통증이 6개월 이상 지속되는 만성 석회화 건염 환자들만을 대상으로 하였다. 임상적 평가는 시술 전과 후 12주째 임상적 기능향상 및 증상 호전 정도를 ASES, KSS, CSS와 방사선학적 호전 정도를 석회화 결절의 크기 변화로 평가하였다. 결과: 세 군 모두에서 임상적 기능의 개선과 석회화의 감소가 나타났으며, 특히 임상적인 개선이 다발성 천공술만을 시행한 군(3 군)보다 추가적인 ESWT를 시행한 군(1, 2군)에서 매우 높게 나타났다. 또 방사선학적으로 볼 때, 석회화의 크기와 진행 속도는 통계적으로 유의하게 줄어들었다. 군간의 비교를 보면, 임상기능 개선의 정도와 석회화의 속도 감소의 차이는 고에너지 군(1군), 다발성 천공술(3군) 사이가 저에너지 군(2군), 다발성 천공술(3군)에서 보다 더 크게 나타났다, 그러나, 고에너지 군(1군)과 저에너지 군(2군)에서는 큰 차이가 없었다. 결론: 만성 석회화 건염의 치료를 위해, 추가적인 체외 충격파 치료는 다발성 천공술 단일로 시행했을 때보다 에너지 수준에 관계없이 임상적 기능의 개선과 석회화의 감소에 더 우수한 효과를 보여주었다. 그러나, 에너지 수준에 의한 체외 충격파 치료의 결과로, 석회화의 감소와 임상 기능 개선 정도에 대한 큰 차이가 없었다.

  • PDF

전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구 (A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia)

  • 박문규;노시철;박재현;최흥호
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.

Indirect Detection of Internal Defects in Wooden Rafter with Ultrasound

  • Lee, Sang-Joon;Lee, Sangdae;Pang, Sung-Jun;Kim, Chul-Ki;Kim, Kwang-Mo;Kim, Ki-Bok;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권2호
    • /
    • pp.164-172
    • /
    • 2013
  • The purpose of this research was development of quantitative ultrasonic test methodology for detecting internal defects in members of ancient wooden building. Connection part between wooden members and/or contacted or hidden part by wall of ceiling or other construction materials make it hard to apply direct way of ultrasonic test. So indirect way of ultrasonic test needed to be applied. Test methodology with newly developed prototype of ultrasonic system was proposed. Homogeneous material with polypropylene was also tested for establishing the criterion. Results showed that TOF(time of flight)-energy and pulse length were found out to be proper ultrasonic parameters for predicting depth of defect in wood different from polypropylene. It was not possible to directly apply prediction equation derived from polypropylene. Newly established prediction equation shows coefficient of determination of 0.73 for wood. Finally, defect of replaced rafter members was predicted with the coefficient of determination of 0.32. Various aspects of ultrasound propagation in wood including anisotropy need to be carefully considered to raise up the prediction accuracy.

잉여슬러지의 초음파 처리에 의한 혐기성 소화에서의 메탄생성 특성 연구 (Characteristics of Anaerobic Methane Production by Ultrasonic Treatment of Excess Sludge)

  • 이종학;정태영;노현석;김동진
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.810-815
    • /
    • 2010
  • Ultrasonic sludge pre-treatment has been studied to enhance the performance of anaerobic digestion by increasing sludge hydrolysis which is regarded as the rate-limiting-step of anaerobic digestion. In this study, the effect of ultrasonic pre-treatment on sludge hydrolysis (solubilization) and methane production was investigated. Sludge solubilization efficiency increased with ultrasonic energy input. However, it is uneconomical to apply more than 720 kJ/L as the solubilization efficiency per energy input declines afterwards. Volatile fatty acids concentration increased after the ultrasonic sludge hydrolysis. Anaerobic batch digestion showed that methane volume reached 64.7 and 84.5 mL after 18 days of incubation with the control sludge and ultrasonically hydrolyzed sludge, respectively. Methane production potential, maximum methane production rate, and the lag time of modified Gompertz equation were changed from 70 mL, 6.4 mL/day, and 1.2 days to 89 mL, 9.6 mL/day, and 0.5 day, respectively, after the ultrasonic sludge treatment. The results proved that ultrasonic pre-treatment contributed significantly not only for the methane production but also for the reduction of anaerobic digestion time which is critical for the performance of anaerobic sludge digestion.

통증(痛症)의 한방치료(韓方治療)에 관(關)한 소고(小考) (A Study on the treatment of pain in oriental medicine)

  • 류경주
    • 한국한의학연구원논문집
    • /
    • 제2권1호
    • /
    • pp.454-484
    • /
    • 1996
  • There are many factors to evoke pain, for example cold, heat, seven emotion, digestion, fatigue, venemous worms, deficiency of blood etc., and its pathogenesis is complicated. Treatments for pain in oriental medicine are as follows. 1. Pharmacotherapy is a method to treat pain by different effects of herbal medicine, for example, regulating vital energy, activating blood circulation, eliminating phlegm, and dispelling the cold evil etc. 2. Acupuncture and moxibustion therapy is a kind of external application, it has a distinct effect in relieving pain. Recently its operation method has been more developed, so new acupuncture therapies are used in clinics. There are electroacupuncture, auricular acupuncture and injection of drugs at an acupuncture points etc. 3. Oriental physiotherapy is a treatment method to stimulate acupuncture points and meridians. (1) Hot pack, Paraffin bath, Microwave, Ultrasound, Short wave, Infra-red etc. are used to treat cold syndrome by dispersing cold by warming the channels. (2) E.S.T., I.C.T., T.E.N.S., S.S.P., cupping treatment etc. are used to treat disorders of vital energy. (3) Health ion, Carbon, T.D.P., etc are used to treat conic and deficiency syndrome.

  • PDF