• Title/Summary/Keyword: ultrasound device system

Search Result 44, Processing Time 0.029 seconds

A Study on the Structural Relation among Purchase Decision Factors of Medical Devices, Satisfaction and Repurchasing Intention : Focused on Ultrasound Imaging System (의료기기의 구매결정요인과 만족 및 재구매 의도의 구조적 관계에 관한 연구 : 초음파영상진단장치를 중심으로)

  • Jung, Tae-young;Seo, Geon-seok;Kim, Su-beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3308-3314
    • /
    • 2015
  • The purpose of this study is to investigate the casual relationships among purchase decision factors of medical devices, satisfaction and repurchasing intention. Data of this study is a 2012 survey on medical institutions using medical devices of MW(ministry of health and welfare) and We analyzed 116 medical institutions having ultrasound imaging system lager than general hospitals among data. For empirical analysis, we carried out confirmative factor analysis and path-analysis using AMOS 21.0 package. Main results of this study are as follows: First, brand has positive influence on satisfaction and satisfaction has positive impaction on repurchase intention. Second, although not statistically significant, performance and service have positive impaction on satisfaction and price has negative influence on satisfaction. The significance of this study is to provide empirical basis on establishment of efficient marketing strategy and enhancement of competitiveness for the medical device industry.

Analysis of Fluid-Structure Interaction of Cleaning System of Micro Drill Bits (마이크로 드릴비트 세척시스템의 유체-구조 연성해석)

  • Kuk, Youn-Ho;Choi, Hyun-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • The micro drill bit automatic regrinding in-line system is a system that refurbishes drill bits used in a PCB manufacturing process. This system is able to refurbish drill bits with a minimum size of ø0.15-0.075mm that have previously been discarded. Beyond the conventional manual cleaning process using ultrasound, this system adopts a water jet cleaning system, making it capable of cleaning drill bits with a minimum size of ø0.15-0.075mm. This paper analyses various contact pressures applied to the surface of drill bits depending on the shooting pressure of the cleaning device and fluid velocity in order to optimize the nozzle location and to detect structural instability caused by the contact pressures.

Demonstration of an ultrasonic imaging system for molten lead

  • Jonathan Hawes;Jordan Knapp;Robert Burrows;Robert Montague;Paul Wilcox;Hual-Te Chien;Jeff Arndt;Steve Walters
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1460-1471
    • /
    • 2024
  • 2D and 3D ultrasonic imaging has so far not been demonstrated in pure molten lead in the open literature. In this study the development of such an ultrasonic device for imaging is outlined and results from testing at 380 ℃ in lead are presented. The main difficulties were found to be achieving then maintaining suitable wetting while ensuring suitable durability of the device, both due to the harsh nature of molten lead and the elevated temperatures. The successful detection and imaging (2D and 3D), of differently shaped targets, where the features were above the size of the transmitted ultrasound beam was demonstrated.

An Implementation of ARM 920T Processor-based Ultrasonic Spirometer and Improvement of Its Sensitivity (ARM 920T 프로세서 기반의 초음파 폐활량계 구현 및 감도 향상 연구)

  • Lee, Cheul-Won;Kim, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.268-273
    • /
    • 2005
  • The spirometer is a medical device that measures the instantaneous velocity of the respiratory gas flow capacity. It is used for testing the condition of the lung and patient monitoring. It measures the absolute capacity difference that includes the flow capacity signal. In this paper, by using an ultrasound sensor that reduce+ the error caused by the inertia and pressure it has improved the transmission and receiving signal. This has enabled patients with weak respiratory to use the spirometer. Also, by using the ARM 920T Processor, a precise and prompt detection system was implemented.

Development of Basic Techniques for Ultrasound-guided Follicular Aspiration II. Anesthesic Methods and Development of a Disposable Simplified Needle Guidance System for Ovum Pick-up (초음파유도 난포란 채취를 위한 기본 기술의 개발 II. 소의 마취방법과 채란기구의 개발)

  • 최민철;조성근;강태영;박준규;손우진;이효종
    • Journal of Embryo Transfer
    • /
    • v.12 no.2
    • /
    • pp.211-218
    • /
    • 1997
  • This experiment was carried out to develop the anesthetic methods for ultrasonography and a new simplified disposable needle guidance device for ovum pick-up(OPU) in cows. Three different anesthetic methods were applied as. 1) epidural analgesia only with 2% lidocaine(20~30 ml), 2) epidural analgesia with 2% under general sedation with xylazine, 3) epidural analgesia with 2% lidocaine under general sedation with detomidine. We evaluated the anesthetic effects with items such as relaxation of anal sphincter, tail movement and rectal wall, retractability of both ovaries, additional anesthesia and possibility of OPU. Through this experiment, the above three anesthetic methods were applicable to OPU, but the epidural anlagesia under general sedation with detomldine was most effective for OPU. We developed a new disposable needle guidance device with stainless steel tube. With this, disposable needles can be easily attatchable to any other intravaginal probes. And also, it was found to he practical, economic and effective for OPU with the recovery rate of 51.2%.

  • PDF

A Study on the Implementation of Ultrasonic Guidance Algorithm for Improving Safety of Ultrasonic Varicose Vein Treatment (초음파 하지정맥류 치료의 안전성 개선을 위한 초음파 유도 알고리즘 구현에 관한 연구)

  • Kim, Seong-Cheol;Kim, Ju-Young;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.435-441
    • /
    • 2018
  • In this study, we performed to design an image guiding algorithm to improve the efficiency and safety of treatment of varicose vein by focused ultrasound. The algorithm was suggested by different guiding images according to the location of varicose veins. In the case of deep-seated varicose veins, the target area was marked on the surface of the blood vessel in the obtained cross-sectional blood vessel ultrasound image. In the case of the superficial varicose vein, A guiding system based on image segmentation algorithm of the vascular region was suggested and designed two different algorithms according to varicose veins progression degree. as a results, the algorithm based on ultrasound image show a small error with $830{\mu}m$ at maximum. However, the algorithm based on charge coupled device image has a maximum error of 8.3 mm in some data. Therefore, it is expected that additional study is needed for superficial varicose vein image guiding algorithm, and it is expected that the accuracy of blood vessel tracking should be evaluated by constructing simple system.

A Study on the Clinical Use of 7-zone-diagnostic System(1) Centering around VEGA-DFM 722 and ABR-2000- (7구역진단기의 임상응용에 대한 고찰(1) -VEGA-DFM 722 및 ABR-2000 중심으로-)

  • Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.23 no.3
    • /
    • pp.231-239
    • /
    • 2006
  • Functional medicine is a system which utilizes certain investigative and treatment methods that are primarily oriented toward the recognition of functional disorder. Functional disorders take place on an energetic plane. This plane is not capturable using our regular investigatory techniques, such as X -ray. ultrasound, computer tomography and laboratory analyses. The 7-zone-diagnostic system(VEGA-DFM 722 and ABR-2000, etc) is a diagnostic device Which applies pulse signals to predetermined bodily locations. Applying alternating positive and negative stress to tissues with positive and negative pulses first manifests itself as negative and positive wave forms. The skin has many functions as an organ. It is the organism's interlace with the outsider world. Hence, the manner in which the skin reacts to external stimuli reflects the current state of the organism(as meridian systems). This system make a diagnosis of functional disorder or some typical organic diseases include stress of the mind or the body, and the energetic situation, reserves. We are known a disorder or disease throw the result chart. This result chart contain disorder flow wave forms and some valuable diagnostic hints (letters ; S, OM, RA, etc). In spite of this 7-zone-diagnostic system that is applied plentifully in the clinical application, there is not a statistics which is suitable. Therefor we must carry out many various research in the future.

  • PDF

Development of a measurement device of water level at the bottom of fuel tanks using an optical cable sensor

  • Kim, Hiesik;Lee, Byoungsuk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.95.1-95
    • /
    • 2002
  • <1. New level meter inside the fuel tank> Ultrasound level sensors are widely applied as level meters of liquid tank. Measurement instrument of level between water and fuel is developed. Since the fuel is inflammable, the sensor system doesn't allow to include any electric circuit inside the fuel tank. The optical cable sensor can satisfy this explosive condition. The measurement method with ultrasonic sensor is attached on the tank wall or tank manhole lid. The pressure sensor can't be applied inside the gasoline fuel tank. An ultra-sonic sensor doesn't detect a enough signal reflected from water level deep under gasoline fuel. The pressure sensor is difficult to measure the height o...

  • PDF

A Study on the Electromagnetic Compatibility Evaluation of the Electronic Medical Instrumentation (전자의료기기의 전자파 적합성 평가에 관한 연구)

  • Song, C.G.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.418-421
    • /
    • 2002
  • The immunity testing in this study was performed to examine the conducted immunity and radiated immunity in medical instrumentation. Experiments were performed to assess the conducted emission and radiated emission of medical instrumentation such as MRI, ultrasound system, and electro surgical unit etc. The emission testing revolves around conducted emissions (high-frequency currents) on power lines and signal cables. Emission testing also looks at the output of energy through the air (called radiated emissions) and analyzes the strength of those radio-frequency signals generated unintentionally by the electrical medical device that is under test. Finally, this study would provide significant data for furture research or electromagnetic interference and compatibility test in medical instrumentation.

  • PDF

Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges (집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험)

  • Jun-tae, Kim;Ju-hee, Kim;Kyu-tai, Joo;Kyung-ah, Kim;Ahnryul, Choi;Jae-hyun, Jo;Jin-houng, Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.477-484
    • /
    • 2022
  • In this study, the cartridge part of the focused ultrasound stimulation system was used as a sample to conduct a skin irritation test and a skin sensitization test through animal experiments among the tests related to GLP (Good Laboratory Practice), a medical device safety evaluation standard. The test was conducted after IACUC approval using 6 female New Zeland White Rabbits. The polar and non-polar stimulation indices were all '0.0'. In addition, in the case of skin sensitization evaluation, 30 guinea pigs approved by IACUC were divided into control and experimental groups, and all induction and induction steps were applied using the eluate itself without separate dilution of the test sample and blank test solution. As a result of the experiment, the skin reaction grade of the control animal was 0 grade, and there was no animal showing more than 1 grade in the skin reaction of the test animal. As a result of both tests, no abnormal skin symptoms were observed, and when applied to the human body to treat patients, the test materials used in the tests will investigate the stability of whether any diseases that cause skin abnormal symptoms will occur.