• Title/Summary/Keyword: ultrasound

Search Result 3,005, Processing Time 0.035 seconds

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

High-intensity focused ultrasound beam path visualization using ultrasound imaging (초음파 영상을 이용한 고강도 집중 초음파 빔 시각화)

  • Song, Jae Hee;Chang, Jin Ho;Yoo, Yang Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.1
    • /
    • pp.16-23
    • /
    • 2020
  • In High-Intensity Focused Ultrasound (HIFU) treatment, effective localization of HIFU focus is important for developing a safe treatment plan. While Magnetic Resonance Imaging guided HIFU (MRIgHIFU) can visualize the ultrasound path during the treatment for localizing HIFU focus, it is challenging in ultrasound imaging guided HIFU (USIgHIFU). In the present study, a real-time ultrasound beam visualization technique capable of localizing HIFU focus is presented for USIgHIFU. In the proposed method, a short pulse, with the same center frequency of an imaging ultrasound transducer below the regulated acoustic intensity (i.e., Ispta < 720 mW/㎠), was transmitted through a HIFU transducer whereupon backscattered signals were received by the imaging transducer. To visualize the HIFU beam path, the backscattered signals underwent dynamic receive focusing and subsequent echo processing. From in vitro experiments with bovine serum albumin gel phantoms, the HIFU beam path was clearly depicted with low acoustic intensity (i.e., Ispta of 94.8 mW/㎠) and the HIFU focus was successfully localized before any damages were produced. This result indicates that the proposed ultrasound beam path visualization method can be used for localizing the HIFU focus in real time while minimizing unwanted tissue damage in USIgHIFU treatment.

The Effects of Pain and Range of Motion by Continuous Wave Ultrasound and Pulsed Wave Ultrasound on Patient with Temporomandibular Joint Disability (측두하악관절장애 환자에서 연속초음파와 맥동초음파 적용이 통증과 관절가동범위에 미치는 효과)

  • Moon, Hyun-Ju;Seo, Hyun-Kyu;Gong, Won-Tae
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.1-11
    • /
    • 2007
  • Purpose: The purpose of this study was to determine the effect of continuous wave ultrasound and pulsed wave ultrasound that influence changes in pain and range of motion when applied to patients with temporomandibular joint disability. Methods: The subjects of the study were 40 selected patients who had been diagnosed with temporomandibular joint movement restriction and had endured pain for more than two weeks. These patients had visited K orthopedic surgery in Deagu measured from October 1, 2004 to March 31, 2005. The subjects were divided into two groups with 20 patients each. The one group was applied to continuous wave ultrasound and the other group was applied to pulsed wave ultrasound at a dosage of 1.5 W/$cm^2$ for a duration of 5 minutes and eight times for two weeks. The pain perception degree were measured by using Visual Analogue Scale(VAS) and the range of motion was measured by using a rule for each group. Results: The results obtained were as follows The change in the pain perception degree were statistically significant in both group(p<0.05) ; however, the continuous wave ultrasound group showed more difference in the average decrease in the pain perception degree than did the pulsed wave ultrasound group. Both groups showed significant results regarding changed in the range of motion(p<0.05) ; Comparing the difference in the average of the range of motion between the two groups, came back from normal the range of motion of temporomandibular joint at the both groups. Conclusion : Based on the results of this study, we found that both groups showed decreased pain and increased the range of motion, but the continuous wave ultrasound method had a higher therapy effect pain and the range of motion than the pulsed wave ultrasound method to patients with temporomandibular joint disability. With such finding, we expect that according to ultrasound therapy applicant method can be helped usable accurately to patients with variety symptoms temporomandibular joint disability.

  • PDF

A New Algorithm to Estimate Urine Volume from 3D Ultrasound Bladder Images (3D 초음파 영상에서 방광 내 잔뇨량 추정을 위한 새로운 알고리즘)

  • Cho, Tae Sik;Lee, Soo Yeol;Cho, Min Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.31-38
    • /
    • 2016
  • For the patients with bladder dysfunction, measurement of urine volume inside the bladder is very critical to avoid bladder failure. In measuring urine volume inside a bladder, low-resolution 3D ultrasound images are widely used. However, urine volume estimation from 3D ultrasound images is prone to big errors and inconsistency because of low spatial resolution and low signal-to-noise ratio of ultrasound images. We developed a new robust volume estimation algorithm which is not computationally expensive. We tested the algorithm on a lab-built ultrasound bladder phantom and volunteers. The average error rate of the human bladder volume estimation was 5.9% which was better than the commercial machine.

Usefulness of Ultrasound for Detecting Suspected Peripheral Nerve Lesions in Diagnosis of Peripheral Neuropathy : Case Report and Brief Review of the Literature

  • Jung, Jae-Hyun;Kim, Kwang-Hai;Choi, Soon-Kyoo;Shim, Jae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.132-135
    • /
    • 2013
  • Ultrasound scanning of a peripheral nerve along its expected course is a simple and useful method for determining the cause of peripheral neuropathy. We present 3 cases of peripheral neuropathy in which the pathology was detected by simple ultrasound scanning of the affected nerve. There were 2 cases of entrapment neuropathy due to mucoid cyst and 1 case of nerve sheath tumor. All lesions were visualized by simple ultrasound scanning of the involved peripheral nerve. Our results suggest that if a lesion affecting the peripheral nerve is suspected after history and physical examination or electrophysiologic studies, ultrasound scanning of the peripheral nerve of interest throughout its course is very helpful for identifying the causative lesion.

The effects of Ultrasound on the Platelet of Rats (초음파가 생쥐의 혈소판에 미치는 영향)

  • Cho, Kwang-Ho;Park, Sang-Ock;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.139-149
    • /
    • 2001
  • We found out that there exists threshold dose for the decreased platelet count when we apply change of the platelet count to the defense of the ultrasound experiment. Those diminution is definite effects from the defense of the ultrasound. The number of the platelet count is decreased when we are exposed to ultrasound simultaneously. This should not be occurred. It is easy to use the number of the platelet count in the measurement of the biological dosage and intensity in high dosage relatively due to definite quantative relationship. The biological index to understand synergic effects. which are present when two harmful environmental factors are operating at the same time is functionally assending and antagonistic. There are scattered many factors as physical, Chemical, or physiochemically elements which are harmful to human body in the environment in consideration of ultrasound and the other factors. This experiment is demonstrating that we can use the change of the platelet as an index representing synergic effects of ultrasound.

  • PDF

A Welding Defect Inspection using an Ultrasound Excited Thermography (초음파 서모그라피를 이용한 용접 결함 검사)

  • Jo Jae-Wan;Jeong Jin-Man;Choi Yeong-Su;Jeong Seung-Ho;Jeong Hyeon-Gyu
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.148-150
    • /
    • 2006
  • In this paper, the applicability of an UET(ultrasound excited thermography) for a defect detection of the welded receptacle is described. An UET(ultrasound excited thermography) is a defect-selective and fast imaging tool for damage detection. A high power ultrasound-excited vibration energy with pulse durations of 280ms is injected into the outer surface of the welded receptacle made of Al material. An ultrasound vibration energy sent into the welded receptacle propagate inside the sample until they are converted into the heat in the vicinity of the defect. The injection of the ultrasound excited vibration energy results in heat generation so that the defect is turned into a local thermal wave transmitter. Its local heat emission is monitored by the thermal infrared camera. And they are processed by the image recording system. Measurement was performed on aluminum receptacle welded by using Nd:YAG laser. The observed thermal image revealed two area of defects along the welded seam.

  • PDF

Ultrasonographic Diagnosis in the Knee (슬관절에서의 초음파적 진단)

  • Min, Kyoung-Dae
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • Ultrasound is a first line examination of the knee and useful diagnostic tool in assessing the various knee lesions. The advantages of ultrasound are that it is non-invasive, easily available at bed side, cheap, well accepted by patients, and that it has technical benefits including dynamic evaluation. Its limitations include reliability, which is largely operator dependent and its inability to evaluate deep structures. Technical guidelines of the ultrasound released by European Society of MusculoSkeletal Radiology (ESSR) and ultrasonographic findings of various knee lesions are described.

  • PDF

The Effects of Ultrasound Irradiation on the Heat Shock Protein 70(HSP70) Expression in Rat Knee Articular Cartilage after Immobilization (흰쥐 슬관절 고정 후 초음파 적용이 관절연골내 HSP70의 발현에 미치는 영향)

  • Nam, Ki-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.3
    • /
    • pp.369-376
    • /
    • 2005
  • The purpose of the study was for investigating the effect of therapeutic ultrasound irradiation on HSP70 expression in knee of degraded rat articular cartilage. Knee of ten Sprague-Dawley male rats were immobilized for 4 weeks and divided at random into the control and continuous ultrasound applicated group. The continuous ultrasound applicated group was irradiated with frequency 1MHz, intensity $1W/cm^2$ for 5 minutes. The control group was sham sonication. The immunoreactivity of HSP70 was increased in degraded articular cartilage after untrasound irradiation. These results suggest that therapeutic ultrasound can enhance HSP70 expression in degraded articular cartilage.

  • PDF

Design of Optimized Ultrasound Clinical Work-Flow; Usability Perspective

  • Bag, ByungEun;Yoo, SunKook;Jang, WonSeuk
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.40-42
    • /
    • 2015
  • Purpose Usability is an important factor in our life. This paper presents an approach to design the clinical work-flow for ultrasound system. And, we tried to apply this work-flow in diagnosis ultrasound system. Materials and Methods For user learnability, we follow international standard IEC 60601-1-1 and IEC 62366 which describes usability of medical instrument. User requirement are applied by 10 clinicians who are well aware of usability. We considered user environment and designed clinical work-flow into two types: general use and emergency use. The designed clinical work-flow was evaluated by 10 clinicians and results derived from the evaluation were analyzed. Results We could successfully design optimized clinical workflow of ultrasound system. Conclusion This paper suggests usability testing for optimized ultrasound clinical workflow. Using this clinical work flow, users can enhance their clinical performance and reduce operation time.