• Title/Summary/Keyword: ultrasonic waves

Search Result 540, Processing Time 0.022 seconds

Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images (연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가)

  • Lee, So Hee;Kim, Jong Un;Lee, Su Yeol;Ryu, Jeong Won;Choi, Dong Hyuk;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

Analysis of Ultrasonic Scattering from Side-drilled Holes (원주형 기공에 대한 초음파 산란 해석)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.559-565
    • /
    • 2004
  • Two different methods were used for the scattering analysis of side-drilled holes(SDH). The scattering models include an explicit model based on the Kirchhoff approximation and the solution of the exact separation of variables. The far-field scattering amplitude was calculated and their time-domain results were compared for the case of shear vertical wave. The exact solution predicts the existence of the creeping wave. The Kirchhoff approximation agreed to the exact solution, except the case of the creeping wave. Two measurement models were introduced to predict the response from the SDHs for the case of immersion, pulse-echo testing. The received voltage was calculated for the case of the shear vertical waves with the incident angle of $45^{\circ}$ to the SDH with the diameter of 1mm, and compared with the experimental results.

Improvement of Current Velocity Estimation Method in an ADCP (ADCP에서의 유속 추정 방법 개선에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1818-1825
    • /
    • 2017
  • An Acoustic Doppler Current Profiler(ADCP) measures the current velocity and analyzes the degree of turbulence using Doppler effects of ultrasonic waves. Therefore, the autocorrelation or FFT spectrum estimates are obtained for extraction of current velocity in each spatial region. However, if the correlation method does not satisfy the assumption that the return signal spectra are symmetric Gaussian, the large bias errors can occur. Also, the accurate estimation of autocorrelation or FFT spectrum is difficult due to the short acquisition interval when the rapid changes of current velocity occur. Thus, in this paper, the estimation method of the autoregressive spectrum peak is suggested for the accurate current velocity measurement of both symmetric and asymmetric spectra. It is shown that estimation quality can be improved using the suggested method comparing with the conventional methods. Many return signals under the various environment are simulated and the results are compared and analyzed for evaluation of the suggested method.

Wave Generation and Its Effect on Lesion Detection in Sonoelastography: Theory and Simulation Study (음향 탄성영상법에서 연조직 내 파동 발생과 병변 검출의 특성: 이론 및 시뮬레이션 연구)

  • 박정만;권성재;정목근
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.282-293
    • /
    • 2005
  • Sonoelastography is an ultrasound-based technique that visualizes the elastic properties of soft tissues by measuring the tissue motion generated by an externally applied vibration. In this paper. the characteristics of wave generation in soft tissues due to an acoustic vibrator are studied. The effects of modal patterns on the detectability of lesions such as tumors in senoelastography are also investigated These are accomplished by analyzing the vibration patterns calculated using theoretical equations and finite element methods in halt space, infinite plate. and finite-sized tissue. A finite-width source generates shear waves with large amplitude Propagating in specific directions. and the generation characteristics depend both on the width and frequency of the vibrator. as well as the distance from it. It is shown in a finite-sized tissue that the lesion detection in displacement images is quit dependent on the modal patterns inside tissue. In contrast it Is also found that the lesion detectability in strain images is less dependent on the modal Patterns and is much better than that in displacement images.

Diamond Crystal Growth Behavior by Hot Filament Chemical Vapor Deposition According to Pretreatment Conditions

  • Song, Chang Weon;You, Mi Young;Lee, Damin;Mun, Hyoung Seok;Kim, Seohan;Song, Pung Keun
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.5
    • /
    • pp.241-248
    • /
    • 2020
  • The change of the deposition behavior of diamond through a pretreatment process of the base metal prior to diamond deposition using HFCVD was investigated. To improve the specific surface area of the base material, sanding was performed using sandblasting first, and chemical etching treatment was performed to further improve the uniform specific surface area. Chemical etching was performed by immersing the base material in HCl solutions with various etching time. Thereafter, seeding was performed by immersing the sanded and etched base material in a diamond seeding solution. Diamond deposition according to all pretreatment conditions was performed under the same conditions. Methane was used as the carbon source and hydrogen was used as the reaction gas. The most optimal conditions were found by analyzing the improvement of the specific surface area and uniformity, and the optimal diamond seeding solution concentration and immersion time were also obtained for the diamond particle seeding method. As a result, the sandblasted base material was immersed in 20% HCl for 60 minutes at 100 ℃ and chemically etched, and then immersed in a diamond seeding solution of 5 g/L and seeded using ultrasonic waves for 30 minutes. It was possible to obtain optimized economical diamond film growth rates.

Clinical Investigation of Survey and Test in Korean Oriental Pediatrics (한방소아과 설문지 및 검사에 관한 임상현황연구)

  • Hwang, Young-Jun;Kim, Ki-Bong;Min, Sang-Yeon;Kim, Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.22 no.1
    • /
    • pp.25-34
    • /
    • 2008
  • Objectives The purpose of this study is to investigate whether Korean oriental pediatrics hospitals are using their feedback surveys to improve their medical conditions. Methods We selected 24 oriental medicine university hospitals and sent surveys to investigate. 15 of those surveys were analyzed. Results The results were classified as follows; Only 9 of university hospital said that they are currently using their feedback surveys to improve their services. Question for asking the purpose of doing their feedback surveys, 58.3% of hospital responded to get some information for diagnosis, 25% of them said to see the progress of treatment of specific disease, and 16.7% answered for using their data to the further studies. The question about the reason why hospital were need to make these feedback surveys, 46.2% of them answered to apply better service, 38.4% of them said to post medical journal. The question for asking what do oriental medical hospitals check from feedback surveys, 40% of them said they check Ryodoraku, 33.3% was pulse diagnostic apparatus, EAV(Electro-puncture According to Voll) was 26.7%. The classification according to purpose of test resulted as follows; information for diagnosis was 48.1%, the progress of a disease was 37.3%. In addition oriental medical test there were blood test, radiological test, brain waves test, Hair Tissue Mineral Analysis(HTMA), ultrasonic test, body composition analysis. Conclusions Further clinical research is necessary for improvement of using the feedback survey effectively.

  • PDF

Identification of Guided-Wave Modes in Pipings of Power Plants by using Air-coupled Transducer (Air-coupled 트런스듀서를 이용한 발전설비 배관에서의 유도초음파 모드 규명)

  • Park, Ik-Keun;Kim, Hyun-Mook;Kim, Yong-Kwon;Song, Won-Joon;Cho, Yong-Sang;Jhang, Kyung-Young;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.341-347
    • /
    • 2004
  • In order to inspect the piping effectively, one of the important components in the facility of power plants, the ultrasonic guided wave was generated by a tomb transducer and was received in a non-contact fashion by using an air-coupled transducer. The guided wave modes that ran be generated by the comb transducer in piping are predicted from the theoretical dispersion curves and the element spacing of a comb transducer. Moreover, to receive the specific modes, the receiving angle of the air-coupled transducer is calculated from Snell's law between the phase velocities of guided waves and the sound velocity of air. The guided wave modes obtained in experiments are identified from the result of time-frequency analysis such as wavelet transform and two-dimensional fast Fourier transform.

Experimental Study for Separation of Membrane and Recovery of Platinum from MEA (연료전지(燃料電池) 막전극접합체(膜電極接合體)의 막분리(膜分離) 및 백금(白金) 회수(回收)에 관(關)한 연구(硏究))

  • Lee, Jin-A;Kang, Suk-Min;Yoo, Sung-Yeol;Kang, Hong-Yoon;Ryu, Ho-Jin
    • Resources Recycling
    • /
    • v.20 no.4
    • /
    • pp.52-57
    • /
    • 2011
  • Present paper reports a new method to separate the electrolyte membranes and carbon paper without using ultrasonic waves and stirring. In this method, these were separated from fuel cell membrane-electrode assembly(MEA) using the distilled water, butanol and surfactant by dipping method without the dispersion of catalyst particles. Separated carbon paper catalysts and fuel cell Pt/C catalysts were heated in aqua regia at $80{\sim}85^{\circ}C$ and added to precipitant. After calcination, Pt metal was recovered which might be used in fabricating new fuel cells.

Correlations between the Muscle Thickness of the Transverse Abdominis and the Multifidus Muscle with Spinal Alignment in College Students (대학생의 배가로근과 뭇갈래근 두께와 척추정렬간의 상관관계)

  • Lim, Jae-Heon
    • PNF and Movement
    • /
    • v.12 no.4
    • /
    • pp.243-248
    • /
    • 2014
  • Purpose: The transverse abdominis and themultifidus muscle are located in the core. They surround one's trunk and help in body stabilization. Specifically, they control spine articulation to maintain posture and balance. Therefore, weakened deep muscle in the trunk may cause spinal malalignment. This study aims to compare the correlation between the thickness of the transverse abdominis and the multifidus muscle and the spine alignment among college students in their 20s. Methods: This study measured the thickness of the transverse abdominis and the multifidus muscle of 42 healthy college students in their 20s using ultrasonic waves. The thickness of the muscle was measured for the length of the cross-section except for fascia. The thickness of the left and right muscles was measured, and the mean value was calculated. As the thickness of the transverse abdominis can increase because of pressure during exhalation, it was measured at the last moment of exhalation. Spinal alignment was measured by the kyphosis angle, lordosis angle, pelvic tilt, trunk inclination, lateral deviation, trunk imbalance, and surface rotation using Formetric III, which is a three-dimensional imaging equipment. They were measured for three times, and the mean values were calculated. The general characteristics of the subjects were analyzed using descriptive statistics. The correlations between each factor were analyzed using Pearson's correlation analysis. Results: The transverse abdominis showed asignificant correlation with trunk inclination (p<.05). The multifidus muscle showed a significant positive correlation with pelvic tilt and a negative correlation with surface rotation (p<.05). Conclusion: The thickness of transverse abdominis and the multifidus muscle appears to influence spinal alignment. Specifically, the multifidus muscle, which plays an important role on the sagittal plane, influences surface rotation, thus making it an important muscle for scoliosis patients. Therefore, a strengthening training program for the transverse abdominis and the multifidus muscle is necessary according to specific purposes among adults with spinal malalignment.

A Study on portable voice recording prevention device (휴대용 음성 녹음 방지 장치 연구)

  • Kim, Hee-Chul
    • Journal of Digital Convergence
    • /
    • v.19 no.7
    • /
    • pp.209-215
    • /
    • 2021
  • This study is a system development for voice information protection equipment in major meetings and places requiring security. Security performance and stability were secured with information leakage prevention technology through generation of false noise and ultrasonic waves. The cutoff frequency band for blocking the leakage of voice information, which has strong straightness due to the nature of the radio wave to the recording prevention module, blocks the wideband frequency of 20~20,000Hz, and the deception jamming technology is applied to block the leakage of voice information, greatly improving the security. To solve this problem, we developed a system that blocks the recording of a portable smartphone using a battery, and made the installation of a separate device smaller and lighter so that customers do not recognize it. In addition, it is necessary to continuously study measures and countermeasures for efficiently using the output of the anti-recording speaker for long-distance recording prevention.