• 제목/요약/키워드: ultrasonic imaging

검색결과 199건 처리시간 0.022초

Advances in Damage Visualization Algorithm of Ultrasonic Propagation Imaging System

  • Lee, Jung-Ryul;Sunuwar, Nitam
    • 비파괴검사학회지
    • /
    • 제33권2호
    • /
    • pp.232-240
    • /
    • 2013
  • This paper presents recent advances in damage visualization algorithms of laser generated ultrasonic propagation imaging(UPI) system. An effective damage evaluation method is required to extract correct information from raw data to properly characterize anomalies present in structure. A temporal-reference free imaging system provides easy and rapid defect inspection capability with less computational complexity. In this paper a number of methods such as ultrasonic wave propagation imaging(UWPI), anomalous wave propagation imaging(AWPI), ultrasonic spectral imaging(USI), wavelet ultrasonic propagation imaging(WUPI), variable time window amplitude mapping(VTWAM), time point adjustment(TPA), time of flight and amplitude mapping(ToF&Amp) and ultrasonic wavenumber imaging(UWI) are discussed with instances of successful implementation on various structures.

하모닉 영상의 물리학 (Physics of Harmonic Imaging)

  • 최민주;양정화;팽동국
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.564-572
    • /
    • 2012
  • 본 논저에서는 하모닉 영상을 소개하고, 그 원리를 및 물리적 특성을 기존 초음파 영상과 대비하여 기술한다. 인체 조직의 경계에서 반사하는 초음파 에코를 이용한 기존의 초음파 영상의 원리를 제시하고 하모닉 성분을 생성하는 비선형 초음파 전파 과정을 개념적으로 기술한다. 초음파 에코 신호로부터 하모닉 성분을 효율적으로 추출하는 pulse inversion technique를 소개하고 구현된 하모닉 영상이 종래의 초음파 영상과 비교하여 장점을 요약한다. 하모닉의 생성 기전에 따라 하모닉 영상을 분류하고 하모닉 영상을 기존의 초음파 영상과 비교한다. 하모닉 영상의 임상적 중요성, 향후 전망 및 새로운 연구 분야를 언급한다.

An Efficient Ultrasonic SAFT Imaging for Pulse-Echo Immersion Testing

  • Hu, Hongwei;Jeong, Hyunjo
    • 비파괴검사학회지
    • /
    • 제37권2호
    • /
    • pp.84-90
    • /
    • 2017
  • An ultrasonic synthetic aperture focusing technique (SAFT) using a root mean square (RMS) velocity model is proposed for pulse-echo immersion testing to improve the computational efficiency. Considering the immersion ultrasonic testing of a steel block as an example, three kinds of imaging were studied (B-Scan, SAFT imaging based on ray tracing technology and RMS velocity). The experimental results show that two kinds of SAFT imaging have almost the same imaging performance, while the efficiency of RMS velocity SAFT imaging is almost 25 times greater than the SAFT based on Snell's law.

Development of Ultrasonic Wave Propagation Imaging System

  • Chia, Chen-Ciang;Lee, Jung-Ryul;Kim, Jong-Heon
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.283-292
    • /
    • 2009
  • Laser-based ultrasonic sensing requires the probe with fixed fecal length, but this requirement is not essential in laser-based ultrasonic generation. Based on this fact, we designed a pulsed laser-based ultrasonic wave propagation imaging (UWPI) system with a tilting mirror system for rapid scanning of target, and an in-line band-pass filtering capable of ultrasoaic mode selection. 1D-temporal averaging, 2D-spatial averaging, and 3D-data structure building algorithms were developed far clearer results allowing fur higher damage detectability. The imaging results on a flat stainless steel plate were presented in movie and snapshot formats which showed the propagation of ultrasound visible as a concentric wavefield emerging from the location of an ultrasonic sensor. A hole in the plate with a diameter of 1 mm was indicated by the scattering wavefields. The results showed that this robust UWPI system is independent of focal length and reference data requirements.

Demonstration of an ultrasonic imaging system for molten lead

  • Jonathan Hawes;Jordan Knapp;Robert Burrows;Robert Montague;Paul Wilcox;Hual-Te Chien;Jeff Arndt;Steve Walters
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1460-1471
    • /
    • 2024
  • 2D and 3D ultrasonic imaging has so far not been demonstrated in pure molten lead in the open literature. In this study the development of such an ultrasonic device for imaging is outlined and results from testing at 380 ℃ in lead are presented. The main difficulties were found to be achieving then maintaining suitable wetting while ensuring suitable durability of the device, both due to the harsh nature of molten lead and the elevated temperatures. The successful detection and imaging (2D and 3D), of differently shaped targets, where the features were above the size of the transmitted ultrasound beam was demonstrated.

Nondestructive Contactless Sensing of Concrete Structures using Air-coupled Sensors

  • Shin, Sung-Woo;Hall, Kerry S.;Popovics, John S.
    • International Journal of Safety
    • /
    • 제7권2호
    • /
    • pp.17-22
    • /
    • 2008
  • Recent developments in contactless, air-coupled sensing of seismic and ultrasonic waves in concrete structures are presented. Contactless sensing allows for rapid, efficient and consistent data collection over a large volume of material. Two inspection applications are discussed: air-coupled impact-echo scanning of concrete structures using seismically generated waves, and air-coupled imaging of internal damages in concrete using ultrasonic tomography. The first application aims to locate and characterize shallow delamination defects within concrete bridge decks. Impact-echo method is applied to scan defected concrete slabs using air coupled sensors. Next, efforts to apply air-coupled ultrasonic tomography to concrete damage imaging are discussed. Preliminary results are presented for air-coupled ultrasonic tomography applied to solid elements to locate internal defects. The results demonstrate that, with continued development, air-coupled ultrasonic tomography may provide improved evaluation of unseen material defects within structures.

FPGA-based design and implementation of data acquisition and real-time processing for laser ultrasound propagation

  • Abbas, Syed Haider;Lee, Jung-Ryul;Kim, Zaeill
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권4호
    • /
    • pp.467-475
    • /
    • 2016
  • Ultrasonic propagation imaging (UPI) has shown great potential for detection of impairments in complex structures and can be used in wide range of non-destructive evaluation and structural health monitoring applications. The software implementation of such algorithms showed a tendency in time-consumption with increment in scan area because the processor shares its resources with a number of programs running at the same time. This issue was addressed by using field programmable gate arrays (FPGA) that is a dedicated processing solution and used for high speed signal processing algorithms. For this purpose, we need an independent and flexible block of logic which can be used with continuously evolvable hardware based on FPGA. In this paper, we developed an FPGA-based ultrasonic propagation imaging system, where FPGA functions for both data acquisition system and real-time ultrasonic signal processing. The developed UPI system using FPGA board provides better cost-effectiveness and resolution than digitizers, and much faster signal processing time than CPU which was tested using basic ultrasonic propagation algorithms such as ultrasonic wave propagation imaging and multi-directional adjacent wave subtraction. Finally, a comparison of results for processing time between a CPU-based UPI system and the novel FPGA-based system were presented to justify the objective of this research.

Spatial Compounding of Ultrasonic Diagnostic Images for Rotating Linear Probe with Geometric Parameter Error Compensation

  • Choi, Myoung Hwan;Bae, Moo Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1418-1425
    • /
    • 2014
  • In ultrasonic medical imaging, spatial compounding of images is a technique where ultrasonic beam is steered to examine patient tissues in multiple angles. In the conventional ultrasonic diagnostic imaging, the steering of the ultrasonic beam is achieved electronically using the phased array transducer elements. In this paper, a spatial compounding approach is presented where the ultrasonic probe element is rotated mechanically and the beam steering is achieved mechanically. In the spatial compounding, target position is computed using the value of the rotation axis and the transducer array angular position. However, in the process of the rotation mechanism construction and the control system there arises the inevitable uncertainties in these values. These geometric parameter errors result in the target position error, and the consequence is a blurry compounded image. In order to reduce these target position errors, we present a spatial compounding scheme where error correcting transformation matrices are computed and applied to the raw images before spatial compounding to reduce the blurriness in the compounded image. The proposed scheme is illustrated using phantom and live scan images of human knee, and it is shown that the blurriness is effectively reduced.

전영역 펄스-에코 초음파전파영상화 시스템의 CN-235의 도색된 샌드위치 조종면 In-situ 비파괴평가 기술 (Nondestructive Evaluation Technique of Painted Sandwich Control Surfaces of CN-235 using Full-field Pulse-echo Ultrasonic Propagation Imaging System)

  • 홍승찬;이정률;박종운
    • Composites Research
    • /
    • 제29권5호
    • /
    • pp.288-292
    • /
    • 2016
  • 본 연구에서는 전영역 초음파전파영상화 시스템이라 불리는 새로운 초음파전파영상화 장치를 소개한다. 본 시스템은 비파괴적으로 구조를 2 축 선형 이동 스테이지 기반으로 검사한다. 일치된 초음파 센싱과 가진 레이저 빔이 구조를 스캔하며 동시에 펄스-에코 모드 레이저 초음파를 수집한다. 이 과정은 스캔영역만큼 큰 두께 방향의 전영역 초음파를 생성하는 것을 가능하도록 한다. 본 시스템을 사용하여 실제로 운용 중인 알루미늄 허니콤 구조 기반의 CN-235의 도색된 샌드위치 조종면를 검사 및 평가하고 구조 검사 결과로써 전영역 초음파전파 영상을 소개하였으며 기존 초음파 탐상 기법의 결과와 비교하여 성능 및 민감도를 검증하였다.

영상진단용 초음파 트랜스듀서를 위한 멀티레벨 음향 프레넬 렌즈의 제작 및 특성 (Fabrication and characteristics of multilevel acoustic Fresnel lens for ultrasonic transducer for diagnostic imaging)

  • 김동현;하강렬;김무준;김정순
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.33-41
    • /
    • 2009
  • A multilevel acoustic Fresnel lens (MAFL) for the ultrasonic imaging transducer of which center frequency is approximately 5.MHz was newly designed and fabricated. The phase level of the lens was 64, and the focal length and the aperture width were 30.mm and 11.mm, respectively. The characteristics of impulse response, acoustic field and imaging performance of the transducer attached the lens were compared with the transducer attached a conventional refraction type acoustic lens (RAL). The results show that the center frequency, the loop sensitivity, and the focal depth of the MAFL transducer were higher or larger than those of the RAL transducer by approximately 0.2.MHz, 1.4.dB, and 2.mm, respectively. Consequently, it was shown that the brighter acoustic images with higher lateral resolution and the increased imaging performance for deep targets can be obtained by using the MAFL transducer.