In ultrasonic medical imaging, spatial compounding of images is a technique where ultrasonic beam is steered to examine patient tissues in multiple angles. In the conventional ultrasonic diagnostic imaging, the steering of the ultrasonic beam is achieved electronically using the phased array transducer elements. In this paper, a spatial compounding approach is presented where the ultrasonic probe element is rotated mechanically and the beam steering is achieved mechanically. In the spatial compounding, target position is computed using the value of the rotation axis and the transducer array angular position. However, in the process of the rotation mechanism construction and the control system there arises the inevitable uncertainties in these values. These geometric parameter errors result in the target position error, and the consequence is a blurry compounded image. In order to reduce these target position errors, we present a spatial compounding scheme where error correcting transformation matrices are computed and applied to the raw images before spatial compounding to reduce the blurriness in the compounded image. The proposed scheme is illustrated using phantom and live scan images of human knee, and it is shown that the blurriness is effectively reduced.
Keywords
Ultrasonic imaging; Spatial compounding; Linear probe; Error compensation; Rotating ultrasonic probe;
Citations & Related Records
연도 인용수 순위
  • Reference
1 P. M. Shankar: 'Speckle Reduction in Ultrasound B-Scans Using Weighted Averaging in Spatial Compounding', IEEE Trans. Ultrasonics, Ferroelectrics, and Frequency Control, 1986, 33(6), 754-758.   DOI   ScienceOn
2 S. K. Jespersen, J. E. Wilhjelm and H. Sillesen: 'Multi-angle compound imaging', Ultrason. Imag., 1998, 20, 81-102.   DOI   ScienceOn
3 M. Berson, A. Roncin and L. Pourcelot: 'Compound scanning with an electrically steered beam', Ultrason. Imaging, 1981, 3, 303-308.   DOI
4 D. A. Carpenter, M. J. Dadd and G. Kossoff: 'A multimode real time scanner', Ultrasound in Med. and Biol., 1980, 6, 279-284.   DOI   ScienceOn
5 A. Hernandez, O. Basset, P. Chirossel and G. Gimenez: 'Spatial compounding in ultrasonic imaging using an articulated scan arm', Ultrasound Med. Biol, 1996, 22(2), 229-238.   DOI   ScienceOn
6 S. Huber, M. Wagner, M. Medl and H. Czembirek: 'Real-time spatial compound imaging in breast ultrasound', Ultrasound Med. Biol., 2002, 28(2), 155-163.   DOI   ScienceOn
7 K. V. Jenderka: 'Resolution improved Ultrasound Attenuation Estimation based on RF-data of Spatial Compound Scans', IEEE Int. Ultrasonics, Ferro-electrics, and Frequency Control Conference, 2004, 2078-2081.
8 Moo-Ho Bae, B-S. Kim, M-K. Jeong, S-J. Kwon, W-Y. Lee and J-C. Seo: 'Improvement of ultrasound image quality by spatial compounding of RF echo', The 11th World Congress in Ultrasound, WFUMB 2006, Ultrasound in Medicine and Biology, 2006, 32(5S), 275.
9 J. G. Ahbott and F. L. Thurstone: 'Acoustic speckle: Theory and experimental analysis', Ultrason. Imaging, 1979, 1, 303-324.   DOI
10 J. E. Wilhjelm, M. S. Jensen, S.K. Jespersen, B. Sahl and E. Falk: 'Visual and Quantitative Evaluation of Selected Image Combination Schemes in Ultrasound Spatial Compound Scanning', IEEE Trans. on Medical Imaging, 2004, 23(2), 181-190.   DOI   ScienceOn
11 Fu, Gonzales, and Lee: 'Robotics: Control, Sensing, Vision and Intelligence', 1987, McGraw-Hill.
12 Myoung H. Choi, "Correction of Parameter Error in Rotating Linear Probe Using Image Registration for Ultrasonic Diagnostic Imaging", Proc. of International Conference on Control, Automation, and Systems, pp. 909-912, Seoul, Korea, Oct., 2008.
13 S. D. Silverstein and M. O'Donnell: 'Frequency and temporal compounding of partially correlated signals: Speckle suppression and image resolution', in Proc. SPIE 845 Visual Commun. Image Processing II, 1987, 188-194.
14 G. E. Trahey, S. W. Smith and O. T. von Ramm: 'Speckle pattern correlation with lateral aperture translation: Experimental results and implications for spatial compounding', IEEE Trans. Ultrason., Ferroelect., Freq. Contr., 1986, 33(3), 257-264.   DOI   ScienceOn
15 G. E. Trahey, J. W. Allison, S. W. Smith and O. T. von Ramm: 'A quantitative approach to speckle reduction via frequency compounding', Ultrason. Imaging, 1986, 8(3), 151-164.   DOI
16 J. F. Krucker, G. L. LeCarpentier, J. B. Fowlkes and P. L. Carson, 'Rapid elastic image registration for 3-D ultrasound', IEEE Trans. Med. Imag., 2002, 21(11), 1384-1394.   DOI   ScienceOn
17 C. B. Burckhardt: 'Speckle in ultrasound B scans', IEEE Trans. Sonics and Ultrason., 1978, SU-25, 1-6.
18 P. N. T. Wells and M. Halliwell: 'Speckle in ultrasonic imaging', Ultrason., 1981, 19, 225-229.   DOI   ScienceOn
19 R. F. Wagner, S. W. Smith, J. M. Sandrik and H. Lopez: 'Statistics of speckle in ultrasound B scans', IEEE Trans. Sonics Ultrason., 1983, SU-30, 156-163.
20 P. C. Li and M. O'Donnell: 'Elevational spatial compounding', Ultrason. Imaging, 1994, 16(3), 176-189.
21 P. A. Magnin, O. T. von Ramm and F. L. Thurstone: 'Frequency compounding for speckle contrast reduction in phased array images,' Ultrason. Imaging, 1982, 4(4), 267-281.   DOI
22 H. E. Melton and P. A. Magnin: 'A-mode speckle reduction with compound frequencies and compound bandwidths', Ultrason. Imaging, 1984, 6(3), 159-173.   DOI
23 J.-Y. Meuwly, J.-P. Thiran and F. Gudinchet: 'Application of adaptive image processing technique to real-time spatial compound ultrasound imaging improves image quality', Invest. Radiol., 2003, 38(5), 257-262.
24 M. O'Donnell and S. D. Silverstein: 'Optimum displacement for compound image generation in medical ultrasound', IEEE Trans. Ultrason., Ferroelect., Freq. Contr., 1988, 35(4), 470-476.   DOI   ScienceOn
25 D. P. Shattuck and O. T. von Ramm: 'Compound scanning with a phased array', Ultrason. Imaging, 1982, 4(2), 93-107.   DOI
26 S. D. Silverstein and M. O'Donnell: 'Speckle reduction using correlated mixed-integration techniques', in Proc. SPIE 768 Pattern Recognition and Acoust. Imaging 1987, 168-172.