• Title/Summary/Keyword: ultra high frequency

Search Result 391, Processing Time 0.024 seconds

Application of RBFN Using LPC of PD Pulse Shapes for Discriminating Among Multi PD Sources

  • Lee, Kang-Won;Lim, Kee-Joe;Kang, Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.177-181
    • /
    • 2003
  • Partial discharge pulse shapes from variable PD (partial discharge) sources sustain many characteristics such as types of PD. Ultra high frequency antennas have wide bandwidth from 30KHz to 2㎓. Therefore, signals taken from a UHF antenna have important attributes (rising time, falling time, shape factor, etc.) for electromagnetic sources, such as PD sources. We investigated PD pulse shapes from several PD sources using a UHF antenna and the results were used for classification of PD sources. Features for discrimination are extracted from frequency distribution and LPC (Linear Prediction Coefficient) of time signal. RBFN are used for investigating the possibility of classification of multi-PD sources.

Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil (절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

Radiation Characteristics of Parallel Slot Antenna for Automotive Radar System (자동차 레이더 시스템을 위한 병렬형 슬롯 방식 안테나의 방사 특성)

  • Kim, Byeong-Woo;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1980-1985
    • /
    • 2010
  • This paper is about design of optimal structure of slot antenna array antenna with inner waveguide in accordance with the slot model, and fabrication of its prototype sample operating at the frequency of 24 GHz. Results of this work can be employed as a useful tool to develop and diversify slot antenna having superior performance and omni-directivity to that of current antenna. The implemented antenna demonstrates ultra-wideband performance for frequency ranges 24 GHz with the relatively high and flat antenna gain of 18.64dBi and low sidelobe levels. In addition, a $2{\times}8$ antenna array for phased-array systems and mm-wave sensor applications is also presented.

Measurement of Ultra-high Frequency(UHF) noise spectra (GIS 변전소의 극초단파대역 잡음환경 측정)

  • Lim, Jae-Sup;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul;Jung, Kil-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1768-1769
    • /
    • 2003
  • 가스절연개폐장치(Gas-insulated Switchgear, GIS)의 예방진단 기술의 한 방법으로, 극 초단파(Ultrahigh frequency) 부분방전(Partial discharge) 센서를 사용하여 결함의 유무를 판별할 수 있다. 그러나 UHF PD 센서에는 부분방전신호 이외에 외부 잡음의 유입 가능성이 크다. 따라서 본 논문에서는 PD 센서 주변 잡음을 측정하기 위하여 $0{\sim}2$ GHz 의주파수영역에서 산지, 도심 지역의 변전소의 위치에 따른 외부 잡음을 측정하였다. 주파수 대역별로 FM 방송, TV 방송, 이동전화, 등의 신호를 판별하였다.

  • PDF

Analysis of Partial Discharge Pulse Damping Characteristics in GIS Using EMTP (EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석)

  • 이도훈;김재철;송승엽;신중은;노광현;김광화
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.103-105
    • /
    • 2003
  • The principle of the ultra-high frequency (UHF) method to detect partial discharge(PD) in GIS is to measure the UHF electromagnetic waves excited by PD pulses. Such electromagnetic waves propagate along the GIS busbar in the TEM-mode, TE-mode, TM-mode. And the coaxial busbar of the GIS acts as a waveguide in which the UHF electromagnetic waves travel. This paper was studied the analysis on damping characteristic of electromagnetic waves excited by PD in GIS and presented the method to yield the cutoff frequency for determine the minimum band of sensor that detect the PD pulse.

  • PDF

Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer (변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.

Collided Tag Signals' Periodic Characteristic based RFID Tag Collision Detection Method

  • Yang, Wan-Seung;Park, Hyung-Chul
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.32-36
    • /
    • 2021
  • This paper presents a novel collided tag signals's periodic characteristic based radio frequency identification (RFID) tag collision detection method for the ultra high frequency (UHF) RFID. The proposed method utilizes that periodicity of tag signals is maintained even under tag collision. In the proposed method, the correlation between received signal and reference edge signal is used. Simulation result shows that the detection performance using the proposed method is about 10 dB better than that of existing method. In addition, the detection performances with different magnitude difference, phase difference, delay, number of tags are analyzed.

Performance Analysis of IEEE P802.15.3a Multi-band UWB Transceiver for DAC Quantization Error in Fading Channel (다중경로 페이딩 채널에서 DAC 양자화 오차에 대한 IEEE P802.15.3a 멀티밴드 UWB 송수신기 성능 분석)

  • 정성원;이승윤;임승호;박규호
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.216-219
    • /
    • 2003
  • In this paper, we present performance analysis of an IEEE P802.15.3a high rate wireless personal area network transceiver. This physical layer standard uses QOSK as its sub-channel modulation scheme and orthogonal frequency domain modulation (OFDM) for sub-bands. OFDM is used for each sub-band so that multi-path effects are absorbed by equalizer and guard, and fading can be approximately modeled as additive white Gaussian noise. In multi-band ultra-wideband system, DAC quantization error is important noise source since high resolution conversion cannot be used due to high power consumption. Simulation result shows that, to get 640-Mbps throughput, at least 5-bits precision is necessary to maintain bit-error rate under 10$\^$-2/, which can be lowered, with channel coding, to 10$\^$-6/ that is the bit-error rate required by IEEE 802.15 upper protocol layer, in 4-meter LOS fading channel.

  • PDF

Detection of Breathing Rates in Through-wall UWB Radar Utilizing JTFA

  • Liang, Xiaolin;Jiang, Yongling
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.11
    • /
    • pp.5527-5545
    • /
    • 2019
  • Through-wall ultra-wide band (UWB) radar has been considered as one of the preferred and non-contact technologies for the targets detection owing to the better time resolution and stronger penetration. The high time resolution is a result of a larger of bandwidth of the employed UWB pulses from the radar system, which is a useful tool to separate multiple targets in complex environment. The article emphasised on human subject localization and detection. Human subject usually can be detected via extracting the weak respiratory signals of human subjects remotely. Meanwhile, the range between the detection object and radar is also acquired from the 2D range-frequency matrix. However, it is a challenging task to extract human respiratory signals owing to the low signal to clutter ratio. To improve the feasibility of human respiratory signals detection, a new method is developed via analysing the standard deviation based kurtosis of the collected pulses, which are modulated by human respiratory movements in slow time. The range between radar and the detection target is estimated using joint time-frequency analysis (JTFA) of the analysed characteristics, which provides a novel preliminary signature for life detection. The breathing rates are obtained using the proposed accumulation method in time and frequency domain, respectively. The proposed method is validated and proved numerically and experimentally.

Transceiver for Human Body Communication Using Frequency Selective Digital Transmission

  • Hyoung, Chang-Hee;Kang, Sung-Weon;Park, Seong-Ook;Kim, Youn-Tae
    • ETRI Journal
    • /
    • v.34 no.2
    • /
    • pp.216-225
    • /
    • 2012
  • This paper presents a transceiver module for human body communications whereby a spread signal with a group of 64 Walsh codes is directly transferred through a human body at a chip rate of 32 Mcps. Frequency selective digital transmission moves the signal spectrum over 5 MHz without continuous frequency modulation and increases the immunity to induced interference by the processing gain. A simple receiver structure with no additional analog circuitry for the transmitter has been developed and has a sensitivity of 250 ${\mu}V_{pp}$. The high sensitivity of the receiver makes it possible to communicate between mobile devices using a human body as the transmission medium. It enables half-duplex communication of 2 Mbps within an operating range of up to 170 cm between the ultra-mobile PCs held between fingertips of each hand with a packet error rate of lower than $10^{-6}$. The transceiver module consumes 59 mA with a 3.3 V power supply.