• Title/Summary/Keyword: u-healthcare device

Search Result 81, Processing Time 0.023 seconds

Development of u-Health Care System for Dementia Patients (치매환자를 위한 u-Health Care 시스템 개발)

  • Shin, Dong-Min;Shin, Dong-Il;Shin, Dong-Kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1106-1113
    • /
    • 2013
  • For patients who have senile mental disorder such as dementia, quantity of excercise and amount of sunlight are important clue for dose and the treatment. Therefore, monitoring health information of daily life is necessary for patients' safety and healthy life. Portable & wearable sensor device and server configuration monitoring data are needed to provide these services for patients. Watch-type device(smart watch) which patients wear and server system are developed in this paper. Smart watch developed includes GPS, accelerometer and illumination sensor, and can obtain real time health information by measuring the position of patients, quantity of exercise and amount of sunlight. Server system includes the sensor data analysis algorithm and web server that doctor and protector can monitor through sensor data acquired from smart watch. The proposed data analysis algorithm acquires quantity of exercise information and detects step count in patients' motion acquired from acceleration sensor and to verify this, the three cases with fast pace, slow pace, and walking pace show 96% of the experimental result. If developed u-Healthcare System for dementia patients is applied, more high-quality medical service can be provided to patients.

The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy (저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향)

  • Park, Young-Sang;Son, ByeongJin;Son, Jaebum;Lee, Hoyul;Jeong, Yoosoo;Song, Chanho;Jung, Euisung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.259-267
    • /
    • 2021
  • Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

Danger Situations Alert System based U-Healthcare (유헬스케어 기반의 위험상황 알림 시스템)

  • Park, Byungdon;Yu, Donggyun;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.193-198
    • /
    • 2017
  • Recently, as interest in health increases, various wearable devices such as smart watch and smart band which can measure user's biometric information are being studied. Conventional wearable devices service the measured biometric information in a form that provides simple monitoring, disease prevention, and exercise amount. However, the user is Lack to deal with the dangerous situation. In this paper, we propose a hazard notification system to address these problems. The biometric information measured by the acceleration sensor and the heart rate sensor is transmitted to the application through the Arduino in real time. It identifies the risk situation through sensor priority measurement and risk situation identification algorithm. If a dangerous situation occurs, a notification message is sent to the guardian indicating the current location of the user. Therefore, it can be expected that if a dangerous situation occurs to a user who needs protection, he can respond promptly.

Recommendation Algorithm based User Exercise Management System (추천 알고리즘 기반 사용자 운동 관리 시스템)

  • Lee, Jongwon;Lim, Hyunkeun;Kim, Hongyoul;Choi, Hyungwook;Jung, Hoekyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.577-578
    • /
    • 2017
  • Existing exercise management systems provided exercise information to the user. However, there is a problem that the accuracy is low due to the absence of an algorithm for analyzing the user's body information and providing information. In this paper, BMI(Body Mass Index) and BMR(Basal Metabolic Rate) values are analyzed to analyze user's body information. It also recommends exercise intensity and momentum to the user and graphs the history of the exercise device that the user has used. Through this, it is considered that the information corresponding to the user's body can be provided and the exercise management can be carried out.

  • PDF

Breathing Measurement and Sleep Apnea Detection Experiment and Analysis using Piezoelectric Sensor

  • Cho, Seokhyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.11
    • /
    • pp.17-23
    • /
    • 2017
  • In this paper, we implemented a respiration measurement system consisting of piezoelectric sensor, respiration signal processing device, and a viewer on a notebook. We tried an experiment for measuring respiration and detecting sleep apnea syndrome when a subject lay on a bed. We applied the respiration measurement algorithm to sensor data obtained from four subjects. In order to get a good graph shape, data manipulation methods such as moving averages and maximum values were applied. The window size for moving average was chosen as N=70, and the threshold value for each subject was customized. In this case, the proposed system showed 96.0% accuracy. When the maximum value among 90 data was applied instead of moving average, our system achieved 95.1% accuracy. In an experiment for detecting sleep apnea syndrome, the system showed that sleep apnea occurred correctly and calculated the average interval of sleep apnea. While infants or the elderly as well as patients with sleep apnea syndrome are lying down on a bed, our results are also expected to be able to cope with some accidental emergency situation by observing their respiration and detecting sleep apnea.

Implementation of a Respiration Measurement System Based on a Nonrestraint Approach (무구속 방식의 호흡 측정 시스템 구현)

  • Cho, Seok-Hyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.33-41
    • /
    • 2014
  • In this paper, we implemented a system to measure respiration rate with nonrestraint sensors comfortable for people to do their everyday life. The proposed system consists of a pad covered with a Piezoelectric sensor, a respiration measuring device able to send the signal data after amplifying and filtering the source signals to the viewer, a viewer providing sensor data visualization and implementing the respiration measuring algorithm. The algorithm is based on a breathing cycle with the local peak points extracted from threshold on sensor data. Respiration measurements on 3 subjects were performed by changing moving averages and thresholds. The proposed system showed less than 5% error rate when proper moving averages are N=50~60 and a range of thresholds is 800~1300. The system will contribute to preventing suffocation during sleep for infants and the elderly living alone.

Design of UWB/WiFi Module based Wireless Transmission for Endoscopic Camera (UWB/WiFi 모듈 기반의 내시경 카메라용 무선전송 설계)

  • Shim, Dongha;Lee, Jaegon;Yi, Jaeson;Cha, Jaesang;Kang, Mingoo
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Ultra-wide-angle wireless endoscopes are demonstrated in this paper. The endoscope is composed of an ultra-wide-angle camera module and wireless transmission module. A lens unit with the ultra-wide FOV of 162 degrees is designed and manufactured. The lens, image sensor, and camera processor unit are packaged together in a $3{\times}3{\times}9-cm3$ case. The wireless transmission modules are implemented based on UWB- and WiFi-based platform, respectively. The UWB-based module can transmit HD video to a computer in resolution of $2048{\times}1536$ (QXGA) and the frame rate of 15 fps in MJPEG compression mode. The maximum data transfer rate reaches 41.2 Mbps. The FOV and the resolution of the endoscope is comparable to a medical-grade endoscope. The FOV and resolution is ~3X and 16X higher than that of a commercial high-performance WiFi endoscope, respectively. The WiFi-based module streams out video to a smart device with th maximum date transfer rate of 1.5 Mbps at the resolution of $640{\times}480$ (VGA) and the frame rate of 30 fps in MJPEG compression mode. The implemented components show the feasibility of cheap medical-grade wireless electronic endoscopes, which can be effectively used in u-healthcare, emergency treatment, home-healthcare, remote diagnosis, etc.

Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet (영구자석과 홀소자를 이용한 무선 집게형 맥진기 특성 연구)

  • Yoon, Woo-Sung;Ji, Jong-Ok;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.179-185
    • /
    • 2014
  • The existing USB connection type of the clip-type pulsmeter equipped with a Hall sensor and a permanent magnet does not have any error or malfunction to measure the pulse wave. The property of the wireless networking system communicating the pulse wave data through the wireless LAN communication by combination USB with Ethernet and Ethernet to Wi-Fi converting system instead of existing USB connection method was investigated. There are exited that the patient needs to stay at close site of the desktop PC without USB connector and the wireless transfer and receiver networking system has pulse wave measurement SW to receive the pulse wave data. Thus it is expected that the study becomes helpful to measure and transfer the exact pulse wave of the patient in a comfortable pose at close range.

A Study on the Analysis of Behavioral Changes of Smart Devices and the Presentation of the Improved Model (스마트 디바이스 행동변화 애플리케이션 분석을 통한 개선모델 제시)

  • Park, In-Hwa;Kim, Hae-Na;Lee, Youngho
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.225-232
    • /
    • 2014
  • Supply of a smart device has been made with the development of communication networks and growing desire of people to improve the quality of life, the service industry about it have been made with smart devices. Among them, there are various services that can help people change their behavior to healthy life. But it does not have a large impact on the behavior change of performer because its been developed as a general process. Therefore in this study examine development situation about current behavior change applications through application markets. Development current situation can be separated by process to two patterns. As a result we propose behavioral change model that includes integrated change model that one of the behavior theory model, accomplish the goal process of goal setting theory and habit formation phase for automate the changes. Also, we provide appropriate service according to the model that leads motivation, sustainability of the action and positive behavior change to performer. We can expect in many aspects such as ability and motivation than existing service.

An Anonymous Authentication Scheme for Health Information Push Service Based on Indoor Location in Hospital (병원 실내 위치기반 의료정보 푸쉬 서비스를 위한 익명 인증 스킴)

  • Ahn, Hae-Soon;Yoon, Eun-Jun;Nam, In-Gil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5C
    • /
    • pp.410-419
    • /
    • 2012
  • This paper proposes a secure and efficient anonymous authentication scheme for health information push service based on indoor location in hospital. The proposed scheme has the following benefits: (1)It is just based on a secure one-way hash function for avoiding complex computations for both health care operations users and health care centers. (2)It does not require sensitive verification table which may cause health care centers to become an attractive target for numerous attacks(e.g., insertion attacks and stolen-verifier attacks), (3)It provides higher security level (e.g., secure mutual authentication and key establishment, confidential communication, user's privacy, simple key management, and session key independence). As result, the proposed scheme is very suitable for various location-based medical information service environments using lightweight-device(e.g., smartphone) because of very low computation overload on the part of both health care operations users and health care centers.