• Title/Summary/Keyword: u-Apartment

Search Result 104, Processing Time 0.024 seconds

Review on the Effectiveness of Apartments According to Insulation Reinforcement of Energy Saving Design Standard - Energy Cost Analysis of Space Heating and Domestic Hot Water - (에너지절약설계기준의 단열 변화에 따른 공동주택 실효성 검토 - 난방 및 급탕에너지 사용금액 분석 -)

  • Kim, Ji-hyeon;Lim, Hee-won;Lee, Hyun-seung;Shin, U-cheul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.1
    • /
    • pp.173-178
    • /
    • 2020
  • In this study, we analyzed space heating and domestic hot water(DHW) charges from 2017 to 2018 for 151,206 households in 202 apartment complexes built from 1997 to 2016, in order to evaluate the effectiveness of Korea's insulation standards reinforcement. The applied insulation standards were revised three times(in 1987, 2001 and 2010). We used the Anderson-Darling test to review the normality of the space heating and DHW charges. As a result, each p-value was greater than 0.05 and it followed the normal distribution. The annual average space heating charges per unit area of apartments with the 1987 insulation standards were 5,237₩/㎡a in 2017 and 5,328₩/㎡a in 2018. The heating charges with the 2001 standards were 4,827₩/㎡a in 2017 and 4,817₩/㎡a in 2018. Compared to previous standards(1987 standards), heating charges decreased by 7.8% and 9.6%. Also the heating charges with the 2010 standards were 3,683₩/㎡a in 2017 and 3,734₩/㎡a in 2018. Compared to previous standards(2001 standards), heating charges decreased by 24.3% and 21.5%. On the other hand, compared to each previous standards, DHW charges were decreased by 12.2%, 13.6% or increased by 4.6%, 6.9%, which means there's no correlation between insulation standards reinforcement and DHW charges.

A Study on the Types and Causes of Defects in Apartment Housing Information and Communication Work (공동주택 정보통신공사 하자 유형 및 원인에 관한 연구)

  • Park, Hyun Jung;Jeong, U Jin;Park, Jae Woo;Kang, Sang Hun;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.231-239
    • /
    • 2021
  • Entering the era of the fourth industrial revolution, information and communication technologies such as CCTV, home network systems and equipment are being used in the construction industry. In particular, in order to increase the autonomy of information and communication technologies in apartments, the government has announced an administrative revision of information and communication-related laws, and companies are focusing on developing technologies such as smart home services. In addition, most domestic and foreign studies on the information and communication work were mainly conducted on technology and management. However there is a lack of research on physical defects affecting the quality of ICT. Therefore, this study collected the defect data registered in the project management system of three domestic construction companies and classified them according to the standards of the Enforcement Decree of the Apartment House Management Act. According to the analysis of the frequency of defects work type, 88.10% of defects occurred in home network equipment work. In addition, analysis of defects type in the four detailed works showed the highest number of operation error. The cause was analyzed and prevention measures and countermeasures were presented in parts of design, construction, and maintenance. The results of this study will improve the quality of apartment housing and be used as basic data for future research on practical defect minimization and prevention measures.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.17 no.2
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing (로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jang, Cheol-Yong;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

The study of the law system for constructing a Home-Network at the environment of apartment houses (공동주택 환경에서의 홈네트워크 구축을 위한 법제도 연구)

  • Lim, Sang-Chul;Kim, Sun-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.801-808
    • /
    • 2008
  • As Home Network facilities are more enlarging on the basis of a Certification system and U-City by a different operators and regional groups. In this paper, describer to the status of it's installation and promotion and arrange it's general idea and law system concept. Also, draw operation system's problems and present counterproposal through analyzing an application basis of the law systems and information-communication technical standards such as construction law, housing law, and regulation to the housing construction standard. etc. We suggest an change necessity of the law system that home network can get ready for safely, facilities, comfortability of the user's convenience.

The Effects of Distance-Accessibility to the Complex Shopping Mall of 'Lotte Mall-Suwon' on the Prices of Its Neighboring Apartments within the Gwonseon-gu of Suwon City (복합쇼핑몰 '롯데몰 수원점'에 대한 거리 접근성이 수원시 권선구 내 인근 아파트가격에 미친 효과)

  • Jeong, Jun Ho
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.576-591
    • /
    • 2019
  • This study attempts to analyze the effects of distance-accessibility to the complex shopping mall of 'Lotte Mall-Suwon', located at the old central and catchment district of the Suwon station in the Province of Gyeonngi, on the prices of its neighboring apartments within the Gwonseon-gu of Suwon City by using the hierarchical and linear-difference in difference regression method. The results of the analysis are as follows. First, before construction the effects of distance-accessibility show the U-shaped pattern, suggesting that the negative external effects of noise and traffic congestion around the Suwon Station affected the prices of its neighboring apartments within the Gwonseon-gu of Suwon City. Second, the effects of distance-accessibility at different times, such as the construction period and after the opening, are statistically significant only in the latter, indicating the reverse U-shaped pattern unlike before the opening. This means that after the opening of the complex shopping mall its external effects as a leisure and convenience space have a positive effect on the prices of its neighboring apartments within the Gwonseon-gu of Suwon City. Third, the effects of distance-accessibility is at an inflection point around 1.6-1.7 kilometers, which means that the U-shaped distance-decay pattern before construction, while the reverse U-shaped pattern is shown after the opening of opening. The latter implies that apartments that are very close to the mall within the Gwonseon-gu of Suwon City enjoy relatively small positive externalities. Therefore, they are exposed to some negative external effects of noise and traffic congestion, but apartments with some distance apart within the Gwonseon-gu of Suwon City maximize those positive externalities. These results suggest that the effects to distance-accessibility are different from location to location.

Performance Analysis of Location-Aware System based on Active Tags (능동태그 기반 위치인식 시스템의 성능 분석)

  • So, Sun-Sup;Eun, Seong-Bae;Kim, Jin-Chun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.422-429
    • /
    • 2007
  • Location awareness is one of the key functionalities to build an U-city. Recently, many of works of the location-aware systems are emerging to commercially apply to on-going large-scale apartment complex based on U-city. As dwellers or cars being attached with active tags are moving in the U-city complex, the active tags periodically broadcast their own identifiers and receivers fixed along the street or in building use those information to calculate location of them. There are several issues to be considered for such an environment. The first is that the number of active tags operating in the same region are large as much as tens of thousands, and the second is that the active tags should be alive without change of batteries more than a year, hence low power consumption is very important. In this paper we propose i) a new architecture for location-aware system considering such issues, ii) technical issues to implement it using active tags, and iii) a mathematical analytic model to investigate overall performance and verify it by comparing with actual experimental results. Through the analysis we can show the theoretical boundary of the lowest packet loss rate and the maximum number of tags with acceptable performance for the systems based on active tags. The results can be applied to practical design of location-based systems of U-City projects.

Adaptive Reuse for Elderly Housing and Residents' Satisfaction (노인주거를 위한 건물의 재사용과 거주자의 만족도)

  • OhJungKwon
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 1994
  • The adaptive reuse of older buildings to housing for the elderly persons is a relatively new but growing phenomenon in the Western Societies. With regard to many tangible and intangible benefits, adaptive reuse can be a way to help older persons who choose "aging-in-place" in the "long-term" community. The exploratory case study indentifies changes in the stisfaction level of residents after relocation to an adaptive reuse elderly apartment in a rural community in the U.S. Data were collected using personal interviews with 17 pre-occupancy and 16 post-occupancy respondents. Findings described characteristics of respondents and dwelling, neighborhood, and overall satisfaction level changes. This exploratory study, one of few studies about adaptive reuse for housing for the elderly, suggests implications for futher studies.

  • PDF

Assessing Middle-income Residents' Attitudes about Their Urban High-rise Condominium in Contemporary American Society

  • Kim, Wonpil
    • Architectural research
    • /
    • v.2 no.1
    • /
    • pp.27-34
    • /
    • 2000
  • Most research on high-rise housing has focused on low-income residences, and usually the psychological and social well-being of women and children. The validity of such findings are questionable for other populations since high-rise living has served other groups and their various needs in particular settings. Lack of knowledge and understanding about high-rises has represented an obstacle to the accurate representation of American urban reality in residential environments. The review of literature and factor analysis identified Important environmental factors. The survey was conducted in the selected downtown high-rise communities of major U.S. cities. Analyses revealed that there were unique characteristics of residents who prefer to live in this type of housing. It was also found that living in middle-income urban high-rise condominiums does not contribute significantly to the problems associated with high-rise living itself. Even though there were some deficiencies of social interaction and activities among residents, the middle-income condominiums were serving particular residents as maintenance-free and safe place imprinted by a positive image of sweet memories or sometimes by a window view presiding over downtown skyline.

  • PDF

The Change of Heating and Cooling Load according to the Thermal Insulation Performance of Window for an Apartment House (창호의 단열성능에 따른 공동주택 냉난방 부하량 변화)

  • Song, Su-Bin;Kim, Young-Tag;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.853-856
    • /
    • 2008
  • Windows have an great effect on annual building load because windows are the weakest parts of building envelope thermally. To reduce the consumption of building energy, the thermal performance of window has to be improved in first place. Therefore this research aims to make a quantitative analysis of the heating and cooling load according to the window thermal performance using the heat load simulation program. As a result of the simulation, annual heat load is down 38% according to the decrease of U-value of window, 1.00 W/$m^2K$. and annual heat load is up 10% according to the decrease of shading coefficient, 0.20. The annual load of the window with Low-E glass is 15% lower than the window with pair glass.

  • PDF