• Title/Summary/Keyword: type of facility

Search Result 1,379, Processing Time 0.027 seconds

A Study on the User Needs for Renovation of Race Track Type of Nursing Units in K University Hospital (K대학병원 병동부 이중복도형의 개선을 위한 사용자 요구 조사연구)

  • Kim, Youngaee;Yim, Ohyon;Kim, Jungshin;Yi, Jongse;Ahn, Uijong
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.3
    • /
    • pp.21-28
    • /
    • 2013
  • Purpose: General hospital in korea is getting large-scaled, specialized and upgraded. So, nursing unit of race track type has been advanced along with a spatial organization, building equipment and environmental approach. This study is to search the guidelines for renovation of nursing unit with race track type in the case of K university hospital in Daejeon. Methods: 9 cases of recently opened general hospital has been analyzed for spatial and environmental design solution. Questionnaires and interviews about user needs of nursing staff, patient and visitors, have been conducted for a nursing care system and facility of nursing units in K university hospital. Results: The user needs are represented as followings. Center core public zone in each floor plan and center core nursing station and supporting areas in nursing unit are good for an adjacency and separation of spatial organization. Toilet of group patient room is necessary to equip for easy, safe and infective aspects, and so toilet install will decrease the patient number and increase the nursing care service. Hall type of station front is good for visibility and observation. It is appropriate to renovate into south facing group patient room for privacy, enough space for nursing care facility and supporting area, enough width of door to move portable medical equipment, room for medical doctor and practical student, noise absorbing of day room. Implications: Upgrading the nursing care service and facility equipment is necessary to reflect the user needs and cooperate with hospital management.

Analysis of the Leisure Choice Attributes at Rural Area of Urban People (도시민의 농촌지역 여가선택속성 분석)

  • Yun, Hee-Jeong;Im, Seung-Bin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.6 s.119
    • /
    • pp.66-77
    • /
    • 2007
  • This study intends to analyze urban peoples' leisure choice attributes of rural areas from a rural demand perspective. For this purpose, this study investigates regional attributes considered in decision making processes for rural tourism destinations of urban residents using a conjoint model as a stated preference model. Based on literature reviews, two questionnaire surveys were conducted. The first questionnaire survey was performed in 4 cities including Seoul, Daejeon, Suwon and Chuncheon with 408 urban residents. The Second questionnaire survey was performed in 5 cities including Seoul, Chuncheon, Daejeon, Jeonju and Busan with about 1,060 urban residents. The study results suggest that the most important attribute in selecting rural ares for tourism are activity programs and convenience of facility, according to part-worth and vector model. The fitness level of model is 0.986, which is very significant. Among the 5 attribute's levels, the rural residents' kindness, the traditional and the ecological programs and the facilities about sign and lodging are more critical factors than other levels. Utilities of each levels decreases as cost and arrival time increases. Regarding the result of market segmentations, respondents having intention to visit can be divided into 4 group; (1) facility or program oriented type, (2) resident's kindness oriented type, (3) arrival time oriented type, and (4) negatively participant type. The results of leisure choice attributes can provide insightful information for regional planning strategies, such as selection of the type of market segments and the key factor of facility and space planning.

Design of POGO Supporession Device Performance Test System (POGO 억제장치 성능 시험기 설계)

  • Lee, Han-Ju;Kim, Ji-Hun;Jeong, Dong-Ho;O, Seung-Hyeop
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.181-187
    • /
    • 2006
  • The present study deals with the experimental facility for PSD (POGO Suppression Device) performance test systems. Basically there are two methods to pulsate the system; whole-feeding-system pulsation and working-fluid pulsation. The latter method adopts either a piston-type pulsator or a restrict-type pulsator. The working-fluid pulsation using a restrict-type pulsator was considered to be the most appropriate experimental system to study the effects of the primary parameters, and a practical design of the system was proposed. Also, the experimental facility adopts the ball valve type pulsator considering the leak problem of the plate type pulsator.

  • PDF

An Architectural Planning Study on the Spatial Composition of Hospices Based on Typology (호스피스 시설의 유형별 공간구성에 관한 건축 계획적 연구)

  • Cho, Kwang-Hyun;Park, Jae-Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.8 no.1
    • /
    • pp.45-52
    • /
    • 2002
  • Recently cancer, AIDS, chronic sickness have increased according to the elevation of socioeconomic level and fast change of lifestyle. The number of patients receiving terminal care increased fairly because the span of life is extended by development of medicinal technology. Also necessity of hospice and palliative care was risen according to the request of terminal patients that remove pain and keep calm life by interest about quality of life. However architectural plan and type specialization of facility which can correspond team's composition and supplied nursing program are not consisting. This study researches about care environment of hospice facility plan through investigation into terminal patient's special quality. The purpose of this study is to propose fundamental datas of hospice facility for architectural plan through comparative analysis of cases of domestic and outside facilities.

  • PDF

A Study on the Supply Estimation and Allocation of Healthcare Facilities for the Elderly People in Seoul (서울시 노인의료복지시설의 공급과 배치에 관한 연구)

  • Lee, Teuk-Koo;Kim, Seok Jun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.11 no.2
    • /
    • pp.7-16
    • /
    • 2005
  • Recently, as the population of the elderly rapidly increases, the number of the special care facility for the elderly is a big social issue. Especially, special care facilities(nursing home, skilled nursing home, etc) for the elderly in Seoul are insufficient now. So this study quantitatively estimates nursing home beds needed in seoul in 2007, 2012 and 2017, and proposes an allocation of these facilities in Seoul. This study is to clarify problems in supply of long-term care facilities and present a solution for them. The main outcome of this study can be summarized into three parts; first, as architectural planning and supply estimation of long term care facility, an aged population of cities and countries in Seoul should be considered. Second, when the allocation of long term care facility in Seoul, the type of facilities, regional equilibrium etc. should be considered. Third, nursing home and residential care home are linked with the other area.

  • PDF

The Analysis of Flow Distribution in the Core Channel of the HANARO Flow Simulated Test Facility (하나로 유동모의 시험설비의 노심채널 유동분포 해석)

  • Park Y C.;Kim K. R.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.151-154
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulated test facility has been developed for the verification of structural integrity of those experimental facilities prior to loading In the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The half-core structure assembly is composed of plenum, grid plate, core channel with flow tubes, chimney and dummy pool. The flow channels are to be filled with flow orifices to simulate similar flow characteristics to the HANARO. This paper describes an analysis of the flow distribution of the cote channel and compares with the test results. As results, the analysis showed similar flow characteristics compared with those in the test results.

  • PDF

Development of a new test facility for the study of pressure transients in tunnel and micro-pressure waves radiated from the tunnel exit on the railroad (철도터널내 압력변동 및 터널 미기압파 저감 시험장치개발에 관한 연구)

  • Kim, Dong-Hyeon;Oh, Il-Geun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.611-618
    • /
    • 2000
  • The test facility of the 1/60-scale models for the train-tunnel interactions was recently developed to investigate the effects of entry portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating to the surroundings of the tunnel exits by KRRI in Korea. The launching system of train model was chosen as air-gun type. In present test rig, after train model is launched, the blast wave by the driver did not enter to inside of the tunnel model. The train model is guided on the one-wire system from air-gun driver to the brake parts of test facility end. Some cases of the experiments were compared with numerical simulations to prove the test facility.

  • PDF

Joint Batch Production and Inventory Rationing Control in a Two-Station Serial Production System (두 단계 일렬 생산 시스템에서 뱃치 생산과 재고 배급 전략의 통합 구현)

  • Kim, Eun-Gab
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.38 no.2
    • /
    • pp.89-97
    • /
    • 2012
  • This paper considers a manufacturer with a two-station make-to-stock and make-to-order serial production system. The MTS facility produces a single type of component and provides components for the MTO facility that produces customized products. In addition to the internal demand from the MTO facility, the MTS facility faces demands from the spot market with the option of to accept or reject each incoming demand. This paper addresses a joint component inventory rationing and batch production control which maximizes the manufacturer's profit. Using the Markov decision process model, we investigate the structural properties of the optimal inventory rationing and batch production policy, and present two types of heuristics. We implement a numerical experiment to compare the performance of the optimal and heuristic policies and a simulation study to examine the impact of the stochastic process variability on the inventory rationing and batch production control.

Development of A New Facility for Moving Model Test (한국형 터널 미기압파 저감 시험기 개발)

  • 김동현;양신추;오일근
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.146-154
    • /
    • 1999
  • The test facility of the 1/60-scale models for the train-tunnel interactions was recently developed to investigate the effects of entry portal shapes, flood shapes and air-shafts for reducing the micro-pressure waves radiating to the surroundings of the tunnel exits by KRRI in Korea. The launching system of train model was chosen as air-gun type. In present test rig, after train model is launched, the blast wave by the driver did not enter to inside of the tunnel model. The train model is guided on the one-wire system from air-gun driver to the brake parts of test facility end. Some cases of the experiments were compared with numerical simulations to prove the test facility.

  • PDF

A Study on Reported Status and Management Plan of Marine Facilities in Korea 2. On the Basis of Region and Type of Facilities (국내 해양시설의 신고 현황과 관리 방안에 관한 연구 2. 지역별 및 시설종류별 현황을 중심으로)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.3
    • /
    • pp.275-285
    • /
    • 2010
  • Present state of nationwide marine facilities reported to 12 regional maritime affairs and port offices of MLTM in Korea for two years 2008 and 2009 was analyzed based on region and type of facilities, and national management plan was proposed in this study. As of the end of 2009, 8 types of marine facilities were reported to Yeosu regional maritime affairs and port office, while only 3 types of facilities were reported to Pohang, Daesan and Jeju regional offices, respectively. Oil and noxious liquid substances storage facilities belonged in the type of facility which was reported to all of 12 regional offices, and ranged from 11 facilities reported to Pyeongtaek regional office to the respective 38 facilities to Yeosu and Masan regional offices. In pollutants storage facilities, 4 facilities were reported to Masan regional office, 2 facilities to Donghae and Mokpo regional offices, respectively, 1 facility to Yeosu, Gunsan and Pyeongtaek regional offices, respectively, and none of facilities to the other regional offices. Ship construction, repair and scrap facilities belonged in the type of facility which was reported to all of 12 regional offices, and 45% of the facilities were concentrated in Southeastern Sea of Korea centering around Busan and Masan. In cargo handling facilities, 3 facilities were reported to Busan and Masan regional offices, respectively, 1 facility to Daesan regional office, and none of facilities to the other regional offices. In wastes storage facilities, 5 facilities were reported to Ulsan regional office, 4 facilities to Gunsan regional office, 2 facilities to Incheon regional office, 1 facility to Yeosu regional office, and none of facilities to the other regional offices. 65% of nationwide water intake and drainage facilities were concentrated in the areas of Pohang and Mokpo, and 78% of nationwide fishing spots at play were concentrated in the area of Masan. In other marine facilities, 4 facilities were reported to Donghae regional office, 3 facilities to Masan regional office, 2 facilities to Yeosu and Pyeongtaek regional offices, respectively, 1 facility to Incheon and Ulsan regional offices, respectively, and none of facilities to the other regional offices. In integrated marine science base facilities, 3 facilities were reported to Jeju regional office, 1 facility to Yeosu, Ulsan and Gunsan regional offices, respectively, and none of facilities to the other regional offices. The management based on the circumstances of regional offices, the management based on the characteristics of the type of facilities, the amendment of the relevant rules and regulations, facility owner's full knowledge and observance of the relevant rules and regulations with regard to the relevant type of facilities, and positive management actions from national point of view were proposed for national management plans of marine facilities.